• 제목/요약/키워드: 3-D contact

검색결과 989건 처리시간 0.027초

Conceptual design and analysis of rotor for a 1-kW-Class HTS rotating machine

  • Kim, J.H.;Hyeon, C.J.;Quach, H.L.;Chae, Y.S.;Moon, J.H.;Boo, C.J.;Kim, H.M.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권4호
    • /
    • pp.45-50
    • /
    • 2017
  • This paper presents a conceptual design and analysis for a 1-kW-class high-temperature superconducting rotating machine (HTSRM) rotor. The designed prototype is a small-scale integration system of a HTSRM and a HTS contactless rotary excitation device (CRED). Technically, CRED and HTSRM are connected in the same shaft, and it effectively charges the HTS coils of the rotor field winding by pumping fluxes via a non-contact method. HTS coils in rotor pole body and toroidal HTS wire in CRED rotor are cooled and operated by liquid nitrogen in cryogen tank located in inner-most of rotor. Therefore, it is crucial to securely maintain the thermal stability of cryogenic environment inside rotor. Especially, we critically consider not only on mechanical characteristics of the rotor but also on cryogenic thermal characteristics. In this paper, we conduct two main tasks covering optimizing a conceptual design and performing operational characteristics. First, rotor parameters are conceptually designed by analytical design codes. These parameters consider to mechanical and thermal performances such as mechanical strength, mechanical rigidity, and thermal heat losses of the rotor. Second, mechanical and thermal characteristics of rotor for 1-kW-class HTSRM are analyzed to verify the feasible operation conditions. Hence, three-dimensional finite element analysis (3D-FEA) method is used to perform these analyses in ANSYS-Workbench platform.

0.4MW 아크 가열 풍동 시험을 통한 삭마 재료의 표면 특성 연구 (A Study on Surface Properties of Ablative Materials from 0.4MW Arc-Heated Wind Tunnel Test)

  • 김남조;오필용;신의섭
    • 한국항공우주학회지
    • /
    • 제43권12호
    • /
    • pp.1048-1053
    • /
    • 2015
  • 고온 환경에 노출되는 열 보호 시스템의 삭마 현상에 의한 표면 침식은 주로 재료의 두께 방향으로 진행된다. 본 논문에서는 0.4MW 아크 가열 풍동을 통한 삭마 실험을 수행하고 삼차원 표면 측정기를 이용하여 삭마 재료의 표면 상태를 측정하였다. 특히, 정밀한 삼차원 이미지 데이터를 획득하여 고온 플라즈마 환경에서 진행된 삭마 재료의 표면 거칠기와 침식량을 산출하였다. 이와 같은 삭마 실험 전후에 발생된 시편의 질량 감소도 함께 측정함으로써 표면 특성의 변화를 정량적으로 비교 및 분석하였다.

WB(Water-Bubble) 기반의 강한 보안성을 갖는 탄력적 네트워크 구간에 관한 연구 (A Study on WB(Water-Bubble) Based Highly Secure Flexible Network Section)

  • 서우석
    • 한국전자통신학회논문지
    • /
    • 제12권5호
    • /
    • pp.737-746
    • /
    • 2017
  • 2017년 통합보안(IS, Integrated Security), 융합 보안(CS, Convergence Security) 등과 같은 새로운 보안시장의 변화 속에서 운영과 관리 차원의 다양한 보안 패러다임이 제시되고 있다. 이러한 솔루션과 기술은 현존하는 네트워크 인프라의 변경과 유동적인 다차원적인 변화를 이끌어 내기보다는 보안성을 높이는 1차원적인 방어에 모든 보안 역량이 집중되어짐으로써 예상치 못한 침해와 장애를 지속적으로 내제하고 있는 네트워크 인프라를 유지해 오고 있다. 따라서 WB(Water-Bubble)이라는 새로운 아이디어를 네트워크 인프라에 접목하고 실험과 구현 기반의 분석을 진행함으로써 유사패턴 공격과 집중화 트래픽 공격을 방어할 수 있는 탄력적 네트워크 구간을 제안하고 개발할 수 있는 기회이기도 한다. 또한 본 논문에서 제안하는 WB 기반의 강한 보안성을 갖는 탄력적 네트워크 구간에 관한 연구기법은 공격의 최종 목적지로 예상되는 네트워크 영역을 울림형태의 탄력적 영역변화를 갖는 네트워크 구간(구역)으로 유동성과 비예측성, 상호 접점비율에 따른 비 영역 확장성 등의 3대 주요 제한 및 보안 기준을 바탕으로 네트워크 구간 보안성 확보를 위한 연구 자료를 제공하고자 한다.

Sol-gel 법을 이용한 내오염 반사방지 코팅막 제조 (Fabrication of Hydrophobic Anti-Reflection Coating Film by Using Sol-gel Method)

  • 김정엽;이지선;황종희;임태영;이미재;현승균;김진호
    • 한국재료학회지
    • /
    • 제24권12호
    • /
    • pp.689-693
    • /
    • 2014
  • Anti-reflection coating films have used to increase the transmittance of displays and enhance the efficiency of solar cells. Hydrophobic anti-reflection coating films were fabricated on a glass substrate by sol-gel method. To fabricate an anti-reflection film with a high transmittance, poly ethylene glycol (PEG) was added to tetraethyl orthosilicate (TEOS) solution. The content of PEG was changed from 1 to 4 wt% in order to control the morphology, thickness, and refractive index of the $SiO_2$ thin films. The reflectance and transmittance of both sides of the coated thin film fabricated with PEG 4 wt% solution were 0.3% and 99.4% at 500 nm wavelength. The refractive index and thickness of the thin film were n = 1.29 and d = 105 nm. Fluoro alkyl silane (FAS) was used for hydrophobic treatment on the surface of the anti-reflection thin film. The contact angle was increased from $13.2^{\circ}$ to $113.7^{\circ}$ after hydrophobic treatment.

Structures and Magnetic Properties of Monomeric Copper(II) Bromide Complexes with a Pyridine-Containing Tridentate Schiff Base

  • Kang, Sung Kwon;Yong, Soon Jung;Song, Young-Kwang;Kim, Young-Inn
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권12호
    • /
    • pp.3615-3620
    • /
    • 2013
  • Two novel copper(II) bromide complexes with pyridine containing Schiff base ligands, $Cu(pmed)Br_2$ and $Cu(pmed)Br_2$ where pmed = N'-((pyridin-2-yl)methylene)ethane-1,2-diamine (pmed) and dpmed = N,N-diethyl-N'-((pyridin-2-yl)methylene)ethane-1,2-diamine (dpmed) were synthesized and characterized using X-ray single crystal structure analysis, optical and magnetic susceptibility measurements. Crystal structural analysis of $Cu(pmed)Br_2$ showed that the copper(II) ion has a distorted square-pyramidal geometry with the trigonality index of ${\tau}=0.35$ and two intermolecular hydrogen bonds, which result in the formation of two dimensional networks in the ab plane. On the other hand, $Cu(pmed)Br_2$ displayed a near square-pyramidal geometry with the value of ${\tau}=0.06$. In both compounds, the NNN Schiff base and one Br atom occupy the basal plane, whereas the fifth apical position is occupied by the other Br atom at a greater Cu-Br apical distance. The reported complexes show $g_{\mid}$ > $g_{\perp}$ > 2.0023 with a $d_{x2-y2}$ ground state and a penta-coordinated square pyramidal geometry. Variable temperature magnetic susceptibility measurements showed that the developed copper(II) complexes follow the Curie-Weiss law, that is there are no magnetic interactions between the copper(II) ions since the Cu--Cu distance is too far for magnetic contact.

초등학생의 실험 기구 조작 능력에 대한 실태 조사 (A Fact-finding Research Exercise into the Handling Abilities of Experimental Apparatus by Elementary School Students)

  • 박재원;윤상미;원정애;백성혜
    • 한국초등과학교육학회지:초등과학교육
    • /
    • 제26권2호
    • /
    • pp.161-170
    • /
    • 2007
  • This study aims at helping us improve the methods used to teach elementary school students how to handle experimental apparatus by examining their manual skills and their understanding of the alcohol lamp, spuit and thermometer. To evaluate their ability to handle each experimental apparatus, a practical skills test and knowledge evaluation sheets were developed. The evaluation was carried out with 270 students from 2 classes each in the 3rd, 4th, 5th and 6th grade of D Elementary School located in Daejeon City. For their handling ability of the alcohol lamp, the results for the practical skills test showed that the students had a very low ability in placing objects in the center of the apparatus for safe use and also in adjusting the height of the trivet to place objects so that they contact the outer flames correctly. For the spuit, the pass rate of the skills test was generally low in regards to how students should grasp a spuit and the timing and method of depressing the rubber part before dipping it into liquid. For the thermometer, on the other hand, the pass rate was relatively high in every respect. The knowledge evaluation results for the use of experimental apparatus showed a very high rate of correct answers for alcohol lamps and thermometers. The test results for spoils also produced a relatively high rate of correct answers, with the exception of the test item regarding the way that students should grasp them.

  • PDF

하중 조건이 지반의 열전도도에 미치는 영향: 입자 스케일에서의 연구 (Loading Effects on Thermal Conductivity of Soils: Particle-Scale Study)

  • 이정훈;주진현;윤태섭;이장근;김영석
    • 한국지반공학회논문집
    • /
    • 제27권9호
    • /
    • pp.77-86
    • /
    • 2011
  • 지반 물질의 열전도도는 경험식이 제안하는 단위 중량, 간극률 등의 영향 인자 이외에도 하중조건에 따라 크게 좌우된다. 본 논문에서는 개별요소법에 의해 생성된 입자상 지반재료의 열 전달 특성을 열 네트워크 모델로 해석하여 하중이 열전도도에 미치는 영향을 평가하였다. 하중의 변화에 의한 개별 입자들간의 접촉수 및 간극률, 간극수의 전도도에 따른 열전도도를 산출하여 영향 요소들간의 관계를 분석하였다. 전도도의 변화 양상은 전단강성도 분석과 유사하게 열전달 방향 및 하중 크기에 따른 멱함수 형태로 회귀분석이 가능하였다. 해석 결과 하중에 따른 입자간 접촉 면적의 증가 및 간극수의 전도도가 전체 입자상 물질의 열 흐름에 큰 영향을 미침을 알 수 있었다. 열전도도의 이방성은 하중 방향에 의해 좌우되며 입자 스케일에서의 매커니즘이 열 흐름을 좌우하는 중요한 인자임을 보였다.

Field Oxide를 이용한 고전압 SiC 쇼트키 diode 제작 (Fabrication of SiC Schottky Diode with Field oxide structure)

  • 송근호;방욱;김상철;서길수;김남균;김은동;박훈수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.350-353
    • /
    • 2002
  • High voltage SiC Schottky barrier diodes with field plate structure have been fabricated and characterized. N-type 4H-SiC wafer with an epilayer of ∼10$\^$15/㎤ doping level was used as a starting material. Various Schottky metals such as Ni, Pt, Ta, Ti were sputtered and thermally-evaporated on the low-doped epilayer. Ohmic contact was formed at the backside of the SiC wafer by annealing at 950$^{\circ}C$ for 90 sec in argon using rapid thermal annealer. Field oxide of 550${\AA}$ in thickness was formed by a wet oxidation process at l150$^{\circ}C$ for 3h and subsequently heat-treated at l150$^{\circ}C$ for 30 min in argon for improving oxide quality. The turn-on voltages of the Ni/4H-SiC Schottky diode was 1.6V which was much higher than those of Pt(1.0V), Ta(0.7V) and Ti(0.7). The voltage drop was measured at the current density of 100A/$\textrm{cm}^2$ showing 2.1V for Ni Schottky diode, 1.45V for Pt 1.35V, for Ta, and 1.25V for Ti, respectively. The maximum reverse breakdown voltage was measured 1100V in the file plated Schottky diodes with 101an thick epilayer.

  • PDF

SQUID를 이용한 심자도 기술의 개발동향 (Review of Magnetocardiography Technology based on SQUIDs)

  • 이용호;권혁찬;김진목;김기웅;유권규;박용기
    • Progress in Superconductivity
    • /
    • 제13권3호
    • /
    • pp.139-145
    • /
    • 2012
  • Electric activity of cardiac muscles generates magnetic fields. Magnetocardiography (or MCG) technology, measuring these magnetic signals, can provide useful information for the diagnosis of heart diseases. It is already about 40 years ago that the first measurement of MCG signals was done by D. Cohen using SQUID (superconducting quantum interference device) sensor inside a magnetically shielded room. In the early period of MCG history, bulky point-contact RF-SQUID was used as the magnetic sensor. Thanks to the development of Nb-based Josephson junction technology in mid 1980s and new design of tightly-coupled DC-SQUID, low-noise SQUID sensors could be developed in late 1980s. In around 1990, several groups developed multi-channel MCG systems and started clinical study. However, it is quite recent years that the true usefulness of MCG was verified in clinical practice, for example, in the diagnosis of coronary artery disease. For the practical MCG system, technical elements of MCG system should be optimized in terms of performance, fabrication cost and operation cost. In this review, development history, technical issue, and future development direction of MCG technology are described.

압저항 센서와 가압조절 로봇을 이용한 부침맥 검출에 관한 임상연구 (Clinical Study on the Floating and Sinking Pulse Detection with Piezoresistive Sensors and Contact Pressure Control Robot)

  • 이시우;이유정;이혜정;강희정;김종열
    • 동의생리병리학회지
    • /
    • 제19권6호
    • /
    • pp.1673-1675
    • /
    • 2005
  • The pulse diagnosis is an important and universal method in Oriental medicine. Nevertheless, because of characteristic that depends on subjective sense of Oriental medicine doctor (OMD), it is not recognized by objective basis. The Korean Institute of Oriental Medicine(KIOM) and Daeyo Medi. Co. Ltd. developed the 3-D Mac using arrey piezoresistive sensors and multi-axial robot. 133 healthy subjects participated in this study, 75 males and 58 females, between 20 and 70 years of age. All subjects were relaxed in a supine position on a comfortable chair for twenty minutes before the measurement was taken. The measured position is the radial artery of subject's left wrist and the position is called Chon, Kwan and Chuck in Oriental medicine. To detect floating and sinking pulse, we established coefficient of floating and sinking(CFS). CFS means relative position of maximum pulse pressure in PH curve. The lower CFS value means that the pulse has floating tendency. There was significant diffence between CFS and diagnosis of floating-sinking pulse by OMD(p=0.020). CFS value of over 40's group was significantly larger than those of 20's and 30's(p=0.000). There was no significant difference between male and female(p=0.061).