• 제목/요약/키워드: 3-D compensator

검색결과 47건 처리시간 0.025초

Practical Virtual Compensator Design with Dynamic Multi-Leaf Collimator(dMLC) from Iso-Dose Distribution

  • Song, Ju-Young;Suh, Tae-Suk;Lee, Hyung-Koo;Choe, Bo-Young;Ahn, Seung-Do;Park, Eun-Kyung;Kim, Jong-Hoon;Lee, Sang-Wook;Yi, Byong-Yong
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.129-132
    • /
    • 2002
  • The practical virtual compensator, which uses a dynamic multi-leaf collimator (dMLC) and three-dimensional radiation therapy planning (3D RTP) system, was designed. And the feasibility study of the virtual compensator was done to verify that the virtual compensator acts a role as the replacement of the physical compensator. Design procedure consists of three steps. The first step is to generate the isodose distributions from the 3D RTP system (Render Plan, Elekta). Then isodose line pattern was used as the compensator pattern. Pre-determined compensating ratio was applied to generate the fluence map for the compensator design. The second step is to generate the leaf sequence file with Ma's algorithm in the respect of optimum MU-efficiency. All the procedure was done with home-made software. The last step is the QA procedure which performs the comparison of the dose distributions which are produced from the irradiation with the virtual compensator and from the calculation by 3D RTP. In this study, a phantom was fabricated for the verification of properness of the designed compensator. It is consisted of the styrofoam part which mimics irregular shaped contour or the missing tissues and the mini water phantom. Inhomogeneous dose distribution due to the styrofoam missing tissue could be calculated with the RTP system. The film dosimetry in the phantom with and without the compensator showed significant improvement of the dose distributions. The virtual compensator designed in this study was proved to be a replacement of the physical compensator in the practical point of view.

  • PDF

Improving the Linearity of CMOS LNA Using the Post IM3 Compensator

  • Kim, Jin-Gook;Park, Chang-Joon;Kim, Hui-Jung;Kim, Bum-Man;Kim, Young-Sik
    • Journal of electromagnetic engineering and science
    • /
    • 제7권2호
    • /
    • pp.91-95
    • /
    • 2007
  • In this paper, a new linearization method has been proposed for a CMOS low noise amplifier(LNA) using the Post IM3 Compensator. The fundamental operating theory of the proposed method is to cancel the IM3 components of the LNA output signal by generating another IM3 components, which are out-phase with respect to that of the LNA, from the Post IM3 Compensator. A single stage common-source LNA has been designed to verify the linearity improvement of the proposed method through $0.13{\mu}m$ RF CMOS process for WiBro system. The designed LNA achieves +7.8 dBm of input-referred 3^{rd}$-order intercept point (IIP3) with 13.2 dB of Power Gain, 1.3 dB of noise figure and 5.7mA @1.5V power consumption. IIP3 is compared with a conventional single stage common-source LNA, and it shows IIP3 is increased by +12.5 dB without degrading other features such as gain and noise figure.

6MV X-선에 대한 삼차원적 조직보상체의 연구 (A Study of Three-dimension Tissue Equivalent Compensator for 6MV X-Rays)

  • 김옥배;최태진;서수지
    • Radiation Oncology Journal
    • /
    • 제7권1호
    • /
    • pp.133-140
    • /
    • 1989
  • Three-dimension paraffin compensator was designed to construct the tissue equivalent compensator for irregular body contours and obiliques beam incidence. The ratio of compensator thickness to tissue deficit was depended on field size, depth and air gap because the scattered dose loss. The ratio of compensator-tissue was optimized 0.79, 0.73, 0.61 and 0.56 in 6MV x-rays as function of field size $4{\times}4$, $10{\times}10$, $20{\times}20$ and $30{\times}30cm^2$ respectively. in our study. Using this tissue equivalent compensator, it can be got 2% difference of dose at same mid-plane in phantom study.

  • PDF

다엽콜리메터와 삼차원 방사선치료계획장치를 이용한 가상 선량보상체 설계 알고리듬 (Algorithm for the design of a Virtual Compensator Using the Multileaf Collimator and 3D RTP System)

  • 송주영;이병용;최태진
    • 한국의학물리학회지:의학물리
    • /
    • 제12권2호
    • /
    • pp.185-191
    • /
    • 2001
  • 물리적인 형태의 선량 보상체 제작 없이 삼차원 방사선치료계획장치 및 다엽콜리메터를 이용한 방사선의 세기변조를 통해 선량보상 효과를 구현할 수 있는 가상 선량보상체 설계 알고리듬을 고안하고 그 타당성을 분석하였다. 선량보상체 설계를 위한 모델로서 신체표면의 굴곡을 묘사할 수 있는 스티로폼 제작물과 소형 물팬텀을 사용하였으며, 이에 대한 정보를 삼차원 방사선치료계획장치에 입력하고, 주어진 조건하에서의 예상 선량분포를 구하였다 이를 기준으로 가상 선량보상체 구현에 필요한 플루언스 지도를 작성하고, 이를 구현할 수 있는 다엽콜리메터의 구동 프로그램을 설계하였다 다엽콜리메타 구동 알고리듬은 Ma의 이론을 근거로 설계하였으며, 모든 프로그램은 IDL5.4를 사용하여 작성하였다. 설계된 가상 선량보상체의 타당성을 검증하기 위해 선량보상체를 적용하였을 때와 적용하지 않았을 경우 각각에 대해 팬텀에 장착한 필름에 방사선을 조사한 후 그 선량분포를 비교, 분석하였으며 그 결과, 가상 선량보상체를 적용하였을 경우 적용하지 않았을 시 보였던 조직결손에 의한 높은 선량분포 영역이 제거되어 목적하고자 한 균일한 선량분포를 구현할 수 있음을 보였다.

  • PDF

두경부암 환자 치료시 3차원 보상체의 임상 적용에 대한 고찰 (Clinical Application of 3-D Compensator in Head and Neck Cancer)

  • 홍동기;이정우;이두현;박광호;김정만
    • 대한방사선치료학회지
    • /
    • 제9권1호
    • /
    • pp.64-70
    • /
    • 1997
  • The goal of radiation treatment planning is to deliver the dose to the patient within $5\%$ of that prescribed. We have often encountered the situation that the area which have not only several irregular contours but also tissue heterogeneities should be treated. With conventional devices such as wedges, missing tissue compensator. there are some limitations to achieve the uniform dose distribution in treatment volume. The use of CT simulator, 3-D planning system, computer-controlled milling machine enables it to deliver the dose uniformally. This report includes the whole procedure which have patient data acquisition 3D planning, computer-controlled milling, performance verification of 3D compensator, and TLD evaluation. We applied it for the treatment of head and heck cancer only. In Spite of the irregular contour and different electron density of tessue, we have achieved the uniformity of the dose distribution within ${\pm}3\%$ relatively. Although there are some problems which are not only verification of performance but uncertainties of using the new treatment device, we believe that the improvement of dosimetry will eliminate the uncertainties of that application. so the other lesions besides head and neck can will be ale to use the 3D compensator to achieve the dose uniformity

  • PDF

Design of an Asymmetrical Three-phase Inverter for Load Balancing and Power Factor Correction Based on Power Analysis

  • Mokhtari, M.;Golshannavaz, S.;Nazarpour, D.;Aminifar, F.
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권3호
    • /
    • pp.293-301
    • /
    • 2011
  • This paper presents a novel theoretical method based on power analysis to obtain voltage reference values for an inverter-based compensator. This type of compensator, which is installed in parallel with the load, is usually referred to as the active filter. The proposed method is tailored to design the compensator in such a way that it can simultaneously balance the asymmetric load, as well as correct the power factor of the supply side. For clarity, a static compensator is first considered and a recursive algorithm is utilized to calculate the reactance values. The algorithm is then extended to calculate voltage reference values when the compensator is inverter based. It is evident that the compensator would be asymmetric since the load is unbalanced. The salient feature associated with the proposed method is that the circuit representation of system load is not required and that the load is recognized just by its active and reactive consumptions. Hence, the type and connection of load do not matter. The validity and performance of the new approach are analyzed via a numerical example, and the obtained results are thoroughly discussed.

Exit Beam Dose Profile을 이용한 3차원 보상체의 성능확인 (The Verification of Dosimetric Characteristics of the 3-D Compensator with the Exit Beam Dose Profile)

  • 이상훈;이병용;권수일;김종훈;장혜숙
    • 한국의학물리학회지:의학물리
    • /
    • 제7권2호
    • /
    • pp.3-17
    • /
    • 1996
  • 방사선 치료분야에서 선량 보상체가 널리 이용되고 있으나, 그 보상효과에 대한 확실한 검증 방법은 알려진 바가 거의 없다. 본 연구에서는 Missing Tissue 뿐 아니라, Internal Tissue Inhomogeneity 까지 고려한 3차원 보상체를 제작하고, Exit Beam Dose Profile의 측정값과 본 연구에서 고안한 방법으로 기대값을 구해 비교함으로써 보상체의 성능을 평가하고자 하였다. 환자정보는 CT Simulator를 사용하여 얻었고, 보상체 정보는 Render Plan 3-D Planning System을 통해 얻었다. Computer Controlled Milling Machine으로 알루미늄 보상체를 제작해서 보상체가 있는 경우와 없는 경우의 선량 프로파일을 측정하여 비교하였다. 측정은 폴리스티렌 팬톰 사이에 필름을 삽입하여 팬톰 내에서의 실제 선량 분포를 구하고, 필름 카셋트를 이용해서 Exit Beam Dose Profile 을 동시에 얻었다. Oblique Beam, Parallel Opposing Beam, Inhomogeneus Human Phantom에 대해 제작된 보상체가 각각 선량보상 효과가 잘 나타남을 볼 수 있었고, 이 연구에서의 성능확인 방법을 통해 보상체의 성능을 확인할 수 있었다.

  • PDF

Mismatching Problem between Generic Pole-assignabilities by Static Output Feedback and Dynamic Output Feedback in Linear Systems

  • Kim Su-Wood
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권1호
    • /
    • pp.56-69
    • /
    • 2005
  • In this paper, it is clearly shown that the two well-known necessary and sufficient conditions mp n as generic static output feedback pole-assignment and mp + d(m+p) n+d as generic minimum d-th order dynamic output feedback pole-assignment on complex field, unbelievably, do not match up each other in strictly proper linear systems. For the analysis, a diagram analysis is newly created (which is defined by the analysis of 'convoluted rectangular/dot diagrams' constructed via node-branch conversion of the signal flow graphs of output feedback gain loops). Under this diagram analysis, it is proved that the minimum d-th order dynamic output feedback compensator for pole-assignment in m-input, p-output, n-th order systems is quantitatively decomposed into static output feedback compensator and its associated d number of arbitrary 1st order dynamic elements in augmented (m+d)-input, (p+d)-output, (n+d)-th order systems. Total configuration of the mismatched data is presented in a Table.

Double-Sharpened Decimation Filter Employing a Pre-droop Compensator for Multistandard Wireless Applications

  • Jeong, Chan-Yong;Min, Young-Jae;Kim, Soo-Won
    • ETRI Journal
    • /
    • 제33권2호
    • /
    • pp.169-175
    • /
    • 2011
  • This paper presents a double-sharpened decimation filter based on the application of a Kaiser and Hamming sharpening technique for multistandard wireless systems. The proposed double-sharpened decimation filter uses a pre-droop compensator which improves the passband response of a conventional cascaded integrator-comb filter so that it provides an efficient sharpening performance at half-speed with comparison to conventional sharpened filters. In this paper, the passband droop characteristics with compensation provides -1.6 dB for 1.25 MHz, -1.4 dB for 2.5 MHz, -1.3 dB for 5 MHz, and -1.0 dB for 10 MHz bandwidths, respectively. These results demonstrate that the proposed double-sharpened decimation filter is suitable for multistandard wireless applications.