• Title/Summary/Keyword: 3-D compensator

Search Result 47, Processing Time 0.018 seconds

Practical Virtual Compensator Design with Dynamic Multi-Leaf Collimator(dMLC) from Iso-Dose Distribution

  • Song, Ju-Young;Suh, Tae-Suk;Lee, Hyung-Koo;Choe, Bo-Young;Ahn, Seung-Do;Park, Eun-Kyung;Kim, Jong-Hoon;Lee, Sang-Wook;Yi, Byong-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.129-132
    • /
    • 2002
  • The practical virtual compensator, which uses a dynamic multi-leaf collimator (dMLC) and three-dimensional radiation therapy planning (3D RTP) system, was designed. And the feasibility study of the virtual compensator was done to verify that the virtual compensator acts a role as the replacement of the physical compensator. Design procedure consists of three steps. The first step is to generate the isodose distributions from the 3D RTP system (Render Plan, Elekta). Then isodose line pattern was used as the compensator pattern. Pre-determined compensating ratio was applied to generate the fluence map for the compensator design. The second step is to generate the leaf sequence file with Ma's algorithm in the respect of optimum MU-efficiency. All the procedure was done with home-made software. The last step is the QA procedure which performs the comparison of the dose distributions which are produced from the irradiation with the virtual compensator and from the calculation by 3D RTP. In this study, a phantom was fabricated for the verification of properness of the designed compensator. It is consisted of the styrofoam part which mimics irregular shaped contour or the missing tissues and the mini water phantom. Inhomogeneous dose distribution due to the styrofoam missing tissue could be calculated with the RTP system. The film dosimetry in the phantom with and without the compensator showed significant improvement of the dose distributions. The virtual compensator designed in this study was proved to be a replacement of the physical compensator in the practical point of view.

  • PDF

Improving the Linearity of CMOS LNA Using the Post IM3 Compensator

  • Kim, Jin-Gook;Park, Chang-Joon;Kim, Hui-Jung;Kim, Bum-Man;Kim, Young-Sik
    • Journal of electromagnetic engineering and science
    • /
    • v.7 no.2
    • /
    • pp.91-95
    • /
    • 2007
  • In this paper, a new linearization method has been proposed for a CMOS low noise amplifier(LNA) using the Post IM3 Compensator. The fundamental operating theory of the proposed method is to cancel the IM3 components of the LNA output signal by generating another IM3 components, which are out-phase with respect to that of the LNA, from the Post IM3 Compensator. A single stage common-source LNA has been designed to verify the linearity improvement of the proposed method through $0.13{\mu}m$ RF CMOS process for WiBro system. The designed LNA achieves +7.8 dBm of input-referred 3^{rd}$-order intercept point (IIP3) with 13.2 dB of Power Gain, 1.3 dB of noise figure and 5.7mA @1.5V power consumption. IIP3 is compared with a conventional single stage common-source LNA, and it shows IIP3 is increased by +12.5 dB without degrading other features such as gain and noise figure.

A Study of Three-dimension Tissue Equivalent Compensator for 6MV X-Rays (6MV X-선에 대한 삼차원적 조직보상체의 연구)

  • Kim, Ok-Bae;Choi, Tae-Jin;Suh, Soo-Jhi
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.133-140
    • /
    • 1989
  • Three-dimension paraffin compensator was designed to construct the tissue equivalent compensator for irregular body contours and obiliques beam incidence. The ratio of compensator thickness to tissue deficit was depended on field size, depth and air gap because the scattered dose loss. The ratio of compensator-tissue was optimized 0.79, 0.73, 0.61 and 0.56 in 6MV x-rays as function of field size $4{\times}4$, $10{\times}10$, $20{\times}20$ and $30{\times}30cm^2$ respectively. in our study. Using this tissue equivalent compensator, it can be got 2% difference of dose at same mid-plane in phantom study.

  • PDF

Algorithm for the design of a Virtual Compensator Using the Multileaf Collimator and 3D RTP System (다엽콜리메터와 삼차원 방사선치료계획장치를 이용한 가상 선량보상체 설계 알고리듬)

  • 송주영;이병용;최태진
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.185-191
    • /
    • 2001
  • The virtual compensator which are realized using a multileaf collimator(MLC) and three-dimensional radiation therapy Planning(3D RTP) system was designed. And the feasibility study of the virtual compensator was done to verify that it can do the function of the conventional compensator properly. As a model for the design of compensator, styrofoam phantom and mini water phantom were prepared to simulate the missing tissue area and the calculated dose distribution was produced through the 3D RTP system. The fluence maps which are basic materials for the design of virtual compensator were produced based on the dose distribution and the MLC leaf sequence file was made for the realization of the produced fluence map. Ma's algorithm were applied to design the MLC leaf sequence and all the design tools were programmed with IDL5.4. To verify the feasibility of the designed virtual compensator, the results of irradiation with or without a virtual compensator were analyzed by comparing the irradiated films inserted into the mini water phantom. The higher dose area produced due to the missing tissue was removed and intended regular dose distribution was achieved when the virtual compensator was applied.

  • PDF

Clinical Application of 3-D Compensator in Head and Neck Cancer (두경부암 환자 치료시 3차원 보상체의 임상 적용에 대한 고찰)

  • Hong, Dong-Ki;Lee, Jeong-Woo;Lee, Koo-Hyun;Park, Kwang-Ho;Kim, Jeong-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.9 no.1
    • /
    • pp.64-70
    • /
    • 1997
  • The goal of radiation treatment planning is to deliver the dose to the patient within $5\%$ of that prescribed. We have often encountered the situation that the area which have not only several irregular contours but also tissue heterogeneities should be treated. With conventional devices such as wedges, missing tissue compensator. there are some limitations to achieve the uniform dose distribution in treatment volume. The use of CT simulator, 3-D planning system, computer-controlled milling machine enables it to deliver the dose uniformally. This report includes the whole procedure which have patient data acquisition 3D planning, computer-controlled milling, performance verification of 3D compensator, and TLD evaluation. We applied it for the treatment of head and heck cancer only. In Spite of the irregular contour and different electron density of tessue, we have achieved the uniformity of the dose distribution within ${\pm}3\%$ relatively. Although there are some problems which are not only verification of performance but uncertainties of using the new treatment device, we believe that the improvement of dosimetry will eliminate the uncertainties of that application. so the other lesions besides head and neck can will be ale to use the 3D compensator to achieve the dose uniformity

  • PDF

Design of an Asymmetrical Three-phase Inverter for Load Balancing and Power Factor Correction Based on Power Analysis

  • Mokhtari, M.;Golshannavaz, S.;Nazarpour, D.;Aminifar, F.
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.293-301
    • /
    • 2011
  • This paper presents a novel theoretical method based on power analysis to obtain voltage reference values for an inverter-based compensator. This type of compensator, which is installed in parallel with the load, is usually referred to as the active filter. The proposed method is tailored to design the compensator in such a way that it can simultaneously balance the asymmetric load, as well as correct the power factor of the supply side. For clarity, a static compensator is first considered and a recursive algorithm is utilized to calculate the reactance values. The algorithm is then extended to calculate voltage reference values when the compensator is inverter based. It is evident that the compensator would be asymmetric since the load is unbalanced. The salient feature associated with the proposed method is that the circuit representation of system load is not required and that the load is recognized just by its active and reactive consumptions. Hence, the type and connection of load do not matter. The validity and performance of the new approach are analyzed via a numerical example, and the obtained results are thoroughly discussed.

The Verification of Dosimetric Characteristics of the 3-D Compensator with the Exit Beam Dose Profile (Exit Beam Dose Profile을 이용한 3차원 보상체의 성능확인)

  • 이상훈;이병용;권수일;김종훈;장혜숙
    • Progress in Medical Physics
    • /
    • v.7 no.2
    • /
    • pp.3-17
    • /
    • 1996
  • Dose compensators have been widely used in radiotherapy fields. But, few reliable verification methods have been reported. We have developed the verification method for the evaluation of the effect of dose compensator using exit beam dose profile. The exit beam dose profiles were measured with and without dose compensator. For this purpose X-Omat V films and lead screened cassettes are used and dose distibutions are compared. Phantom data are collected using CT simulator(Picker, AcQ Sim) and compensator information can be obtained from Render Plan 3-D planning System. Aluminum Compensators are generated by computer controlled milling machine. The real dose distribution in the phantom and the exit beam dose profile can be obtained simultaneously with the films in the phantom and the opposite site of the beam. Dose compensations effects for oblique beam, parallel opposing beam and inhomogeneous human phantom can be obtained using above tools. And we could simate those effects with exit beam dose profile using the method that we have developed in this study.

  • PDF

Mismatching Problem between Generic Pole-assignabilities by Static Output Feedback and Dynamic Output Feedback in Linear Systems

  • Kim Su-Wood
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.1
    • /
    • pp.56-69
    • /
    • 2005
  • In this paper, it is clearly shown that the two well-known necessary and sufficient conditions mp n as generic static output feedback pole-assignment and mp + d(m+p) n+d as generic minimum d-th order dynamic output feedback pole-assignment on complex field, unbelievably, do not match up each other in strictly proper linear systems. For the analysis, a diagram analysis is newly created (which is defined by the analysis of 'convoluted rectangular/dot diagrams' constructed via node-branch conversion of the signal flow graphs of output feedback gain loops). Under this diagram analysis, it is proved that the minimum d-th order dynamic output feedback compensator for pole-assignment in m-input, p-output, n-th order systems is quantitatively decomposed into static output feedback compensator and its associated d number of arbitrary 1st order dynamic elements in augmented (m+d)-input, (p+d)-output, (n+d)-th order systems. Total configuration of the mismatched data is presented in a Table.

Double-Sharpened Decimation Filter Employing a Pre-droop Compensator for Multistandard Wireless Applications

  • Jeong, Chan-Yong;Min, Young-Jae;Kim, Soo-Won
    • ETRI Journal
    • /
    • v.33 no.2
    • /
    • pp.169-175
    • /
    • 2011
  • This paper presents a double-sharpened decimation filter based on the application of a Kaiser and Hamming sharpening technique for multistandard wireless systems. The proposed double-sharpened decimation filter uses a pre-droop compensator which improves the passband response of a conventional cascaded integrator-comb filter so that it provides an efficient sharpening performance at half-speed with comparison to conventional sharpened filters. In this paper, the passband droop characteristics with compensation provides -1.6 dB for 1.25 MHz, -1.4 dB for 2.5 MHz, -1.3 dB for 5 MHz, and -1.0 dB for 10 MHz bandwidths, respectively. These results demonstrate that the proposed double-sharpened decimation filter is suitable for multistandard wireless applications.