• Title/Summary/Keyword: 3-D Contact

Search Result 990, Processing Time 0.037 seconds

Degradation of electrical characteristics in Bio-FET devices by O2 plasma surface treatment and improving by heat treatment (O2 플라즈마 표면처리에 의한 Bio-FET 소자의 특성 열화 및 후속 열처리에 의한 특성 개선)

  • Oh, Se-Man;Jung, Myung-Ho;Cho, Won-Ju
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.199-203
    • /
    • 2008
  • The effects of surface treatment by $O_2$ plasma on the Bio-FETs were investigated by using the pseudo-MOSFETs on the SOI substrates. After a surface treatment by $O_2$ plasma with different RF powers, the current-voltage and field effect mobility of pseudo-MOSFETs were measured by applying back gate bias. The subthreshold characteristics of pseudo-MOSFETs were significantly degraded with increase of RF power. Additionally, a forming gas anneal process in 2 % diluted $H_2/N_2$ ambient was developed to recover the plasma process induced surface damages. A considerable improvement of the subthreshold characteristics was achieved by the forming gas anneal. Therefore, it is concluded that the pseudo-MOSFETs are a powerful tool for monitoring the surface treatment of Bio-FETs and the forming gas anneal process is effective for improving the electrical characteristics of Bio-FETs.

Electroglottographic Measurements of Glottal Function in Voice according to Gender and Age

  • Ko, Do-Heung
    • Phonetics and Speech Sciences
    • /
    • v.3 no.1
    • /
    • pp.97-102
    • /
    • 2011
  • Electroglottography (EGG) is a common method for providing non-invasive measurements of glottal activity. EGG has been used in vocal pathology as a clinical or research tool to measure vocal fold contact. This paper presents the results of pitch, jitter, and closed quotient (CQ) measurements in electroglottographic signals of young (mean = 22.7 years) and elderly (mean = 74.3 years) male and female subjects. The sustained corner vowels /i/, /a/, and /u/ were measured at around 70 dB SPL since the most notable among EGG variables is the phonation intensity, which showed positive correlation with closed phase. The aim of this paper was to measure EGG data according to age and gender. In CQ, there was a significant difference between young and elderly female subjects while there was no significant difference between young and elderly male subjects. The mean value for young males was higher than that for elderly males while the mean value for young females was lower than that for elderly females. Thus, it can be said that in mean values, increased CQ was related to decreased age for females, while CQ decreased for males as the speaker's age decreased. Although the laryngeal degeneration due to increased age seems to occur to a lesser extent in females, the significant increase of CQ in elderly female voices could not be explained in terms of age-related physiological changes. In standard deviation of pitch and jitter, the mean values for young and elderly males were higher than that for young and elderly females. That is, male subjects showed higher in mean values of voice variables than female subjects. This result could be considered as a sign of vocal instability in males. It was suggested that these results may provide powerful insights into the control and regulation of normal phonation and into the detection and characterization of pathology.

  • PDF

A vision-based system for dynamic displacement measurement of long-span bridges: algorithm and verification

  • Ye, X.W.;Ni, Y.Q.;Wai, T.T.;Wong, K.Y.;Zhang, X.M.;Xu, F.
    • Smart Structures and Systems
    • /
    • v.12 no.3_4
    • /
    • pp.363-379
    • /
    • 2013
  • Dynamic displacement of structures is an important index for in-service structural condition and behavior assessment, but accurate measurement of structural displacement for large-scale civil structures such as long-span bridges still remains as a challenging task. In this paper, a vision-based dynamic displacement measurement system with the use of digital image processing technology is developed, which is featured by its distinctive characteristics in non-contact, long-distance, and high-precision structural displacement measurement. The hardware of this system is mainly composed of a high-resolution industrial CCD (charge-coupled-device) digital camera and an extended-range zoom lens. Through continuously tracing and identifying a target on the structure, the structural displacement is derived through cross-correlation analysis between the predefined pattern and the captured digital images with the aid of a pattern matching algorithm. To validate the developed system, MTS tests of sinusoidal motions under different vibration frequencies and amplitudes and shaking table tests with different excitations (the El-Centro earthquake wave and a sinusoidal motion) are carried out. Additionally, in-situ verification experiments are performed to measure the mid-span vertical displacement of the suspension Tsing Ma Bridge in the operational condition and the cable-stayed Stonecutters Bridge during loading tests. The obtained results show that the developed system exhibits an excellent capability in real-time measurement of structural displacement and can serve as a good complement to the traditional sensors.

Rotordynamic Model Development with Consideration of Rotor Core Laminations for 2.2 kW-Class Squirrel-Cage Type Induction Motors and Influence Investigation of Bearing Clearance (2.2 kW급 유도전동기의 회전자 적층구조를 고려한 회전체 동역학 해석모델 개발 및 베어링 간극의 영향 분석)

  • Park, Jisu;Sim, Kyuho;Lee, Sung-Ho
    • Tribology and Lubricants
    • /
    • v.35 no.3
    • /
    • pp.158-168
    • /
    • 2019
  • This paper presents the investigation of two types of rotordynamic modeling issues for 2.2 kW-class, rated speed of 1,800 rpm, squirrel-cage type induction motors. These issues include the lamination structure of rotor cores, and the radial clearance of ball bearings that support the shaft of the motor. Firstly, we focus on identifying the effects of rotor core lamination on the rotordynamic analysis via a 2D prediction model. The influence of lamination is considered as the change in the elastic modulus of the rotor core, which is determined by a modification factor ranging from 0 to 1.0. The analysis results show that the unbalanced response of the rotor-bearing system significantly varies depending on the value of the modification factor. Through modal testing of the system, the modification factor of 0.079 is proven to be appropriate to consider the effects of lamination. Next, we investigate the influence of ball bearing clearance on the rotordynamic analysis by establishing a bearing analysis model based on Hertz's contact theory. The analysis results indicate that negative clearance greatly changes the bearing static behavior. Rotordynamic analysis using predicted bearing stiffness with various clearances from -0.005 mm to 0.010 mm reveals that variations in clearance result in a slight difference in the displacement of the system up to 18.18. Thus, considering lamination in rotordynamic analysis is necessary as it can cause serious analysis errors in unbalanced response. However, considering the effect of the bearing clearance is optional because of its relatively weak impact.

Influence of implant-abutment connection structure on peri-implant bone level in a second molar: A 1-year randomized controlled trial

  • Kim, Jin-Cheol;Lee, Jungwon;Kim, Sungtae;Koo, Ki-Tae;Kim, Hae-Young;Yeo, In-Sung Luke
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.3
    • /
    • pp.147-154
    • /
    • 2019
  • PURPOSE. This study aimed to evaluate the effect of two different implant-abutment connection structures with identical implant design on peri-implant bone level. MATERIALS AND METHODS. This clinical study was a patient-blind randomized controlled trial following the CONSORT 2010 checklists. This trial was conducted in 24 patients recruited between March 2013 and July 2015. Implants with internal friction connection were compared to those with external hex connection. One implant for each patient was installed, replacing the second molar. Implant-supported crowns were delivered at four months after implant insertion. Standardized periapical radiographs were taken at prosthesis delivery (baseline), and one year after delivery. On the radiographs, distance from implant shoulder to first bone-to-implant contact (DIB) and peri-implant area were measured, which were the primary and secondary outcome, respectively. RESULTS. Eleven external and eleven internal implants were analyzed. Mean changes of DIB from baseline to 1-year postloading were 0.59 (0.95) mm for the external and 0.01 (0.68) mm for the internal connection. Although no significant differences were found between the two groups, medium effect size was found in DIB between the connections (Cohen's d = 0.67). CONCLUSION. Considering the effect size in DIB, this study suggested the possibility of the internal friction connection structure for more effective preservation of marginal bone.

A Study on Expression for Indoor Design base of Interactive using Digital Art (디지털 아트를 활용한 인터랙티브 기반의 실내공간디자인 표현 연구)

  • Kim, JaeHeon;Park, Byeong-Ju;Choi, Yeong-Geun;Park, Su-Jin;Kim, Cheeyong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.635-638
    • /
    • 2009
  • The latest, Digital art is attempt new field's Art, that is utilize variously digital media image, sound, simulation, 3D holography. A large number of Digital Art is contact with the audiance in pavilion(limit place and limit period). However, It will be possible, If Digital Art can use place digital form media even there are indoor, outdoor, anywhere. This paper analyze reciprocal action for utilize Digital Art in indoor space design, and this paper study expression about indoor design base of interactive.

  • PDF

A Study on Inductive Power Line Communication with Metal Block Channel (금속블록 채널이 있는 유도형 전력선통신에 관한 연구)

  • Sohn, Kyung-Rak;Kim, Hyun-Sik
    • Journal of IKEEE
    • /
    • v.25 no.1
    • /
    • pp.95-100
    • /
    • 2021
  • If we know the location of the hull block and the welding feeder in the shipyard, we can easily obtain the location information of the worker. That data is very useful for implementing a workplace safety monitoring system. However, it is difficult to apply a fixed communication network to the workplace due to the specificity of the hull structure and welding process. In this study, inductive power line communication, which can replace dedicated communication line, was reviewed. A ferrite core was used as an inductive coupler to be installed on the power cable of the welding machine, and a nano-crystalline core was applied as a coupler to be fastened to the support rod of the metal block. In order to visualize the operating principle of the proposed couplers, 3D modeling and finite element analysis were performed with the COMSOL AC/DC module. In the communication performance test using an aluminum profile, when the communication channel was formed by the contact of the welding electrode, the bandwidth was kept above 6 Mbps.

A Study on the Establishment of Management Methods about Occupational Dermatoses (직업성 피부질환에 대한 현황 파악 및 관리 대책 수립을 위한 연구)

  • Lim, Hyun-Sul;Cheong, Hae-Kwan;Choi, Byung-Soon;Kim, Ji-Yong;Sung, Yeol-Oh;Kim, Yang-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.3 s.54
    • /
    • pp.617-637
    • /
    • 1996
  • Occupational dermatosis is one of the most prevalent occupational disorders. However, the extent of the occupational dermatoses including incidences and prevalencies of each disease entity, and etiologic materials are not yet welt stated in Korea. Authors reviewed the literatures on the statistic data and reports on the occupational dermatoses, and surveyed on the occupational dermatoses in two factories, and surveyed the physicians responsible to the occupational dermatoses with formed questionnaire. The results are as follows; 1. Among medical journals published since 1964, there were 31 articles on the occupational dermatoses. Of 31 articles, 18 were case reports and all others were review articles. Of 18 case reports, 9 were epidemiologic survey. The Workers' Periodic Health Examinations revealed that prevalence of the occupational dermatoses was highest(4.36 per 10,000 workers) in 1974, but number of the cases reported were decreased sharply since 1978 with some tendency to increase since 1981. There were 2,240 reported cases of occupational dermatoses between 1966 and 1992, which is 1.90% of all the reported occupational diseases. Skin infection and injuries due to chemicals were most frequent and there were 6 cases of skin cancer. 2. In an epidemiological survey on the dermatoses among 995 workers in a metal product manufacturing factory and 225 workers in a coal chemical factory, there were 794 with dermatomycosis, 296 workers with acne, 130 workers with scar, 123 workers with deformity of toe nails. Scars, photosensitivity dermatitis, deformity of finger and toe nails, and acne were more prevalent in the metal product manufacturing factory(p<0.05). In the metal prouct manufacturing factory, workers treating organic solvents and oils had more dermatoses than those without treating the materials(p<0.05). On the skin patch performed on 16 workers in the metal product manufacturing factory, there were 8 cases of irritation dermatitis and 5 cases of contact dermatitis. Prevalence of contact dermatitis in the metal product manufacturing factory was 1.3%. 3. On the questionnaire survey, 34 dermatologists, 29 doctors of preventive medicine, and 22 family physician replied. The proportion of occupational etiology among all dermatoses assumed by the physicians were below 9%, and the most important occupational dermatosis in Korea was contact dermatitis. Main etiologic materials related to the occupational dermatosis were organic solvent, acid and alkali, and metals. The reason for the scarcity of report of occupational dermatoses were difficulty in diagnosis and physician's ignorance of the occupational etiology. They replied that to prevent the occupational dermatoses in the workplace, the use of protective devices was most important, and development of diagnostic criteria on the occupational dermatoses is urgent. Above results shows us that there is many workers with occupational dermatoses, but they are mostly unreported. Measures to prevent and manage the occupational dermatoses are not satisfactory at present. Hence, authors suggest measures for the precise diagnosis, report and prevention of the occupational dermatoses. a. Dermatologist, preventive physician, and industrial hygienist should work as a team to examine the high risk group and establish the preventive measures. b. Disease entities, diagnostic criteria of occupational dermatoses should be listed, criteria for the compensation and job fitting at recruitment should be established, and manual for the proper treatment and effective prevention of each occupational dermatosis should be developed. c. Patch test antigens against each occupational category should be developed and it should be available to any physicians responsible. d. To facilitate the diagnosis of occupational dermatoses by the doctors responsible for the Workersr Periodic Health Examination, development of standardized questionnaire, education on the techniques of the patch test, and cooperation with the dermatologist in diagnosis of occupational dermatoses is essential.

  • PDF

Research on the Working Environment and Personal Protective Equipment of Korean Native Cattle Raising Farmers (한우 사육자 작업환경 및 작업복과 보호구 착용 실태 분석)

  • Kim, Insoo;Lee, Kyung-Suk;Chae, Hye-Seon;Kim, Kyungsu;Choi, Dong-Phil;Kim, Hyo-Cher
    • The Korean Journal of Community Living Science
    • /
    • v.27 no.4
    • /
    • pp.891-906
    • /
    • 2016
  • This study examined the working site environment of Korean native cattle raising farmers and their actual condition of wearing personal protective equipment as part of preventing disasters during agricultural work. To this end, 160 Korean cattle raising farmers were surveyed and a site visit was performed on 10 farms. According to an examination of the cattle breeding environment, the major harmful factors were in the following order: fine dust (12.8%), organic feed dust (10.3%), contact with cattle (9.7%), manure (8.2%), germs and viruses (8.1%), harmful gases (7.4), contact with obstacles (6.7), and temperature (6.6%). The current status of the rate of wearing protection was in the order of gloves (20.9%), working hats (19.7%), boots (19.6%), masks (10.9%), protective clothing (8.9%), and specialized working clothing (6.6%). Nevertheless, most Korean cattle raising farmers recognized the risks when they did not wear protective equipment and the need for wearing protectors, but they mostly did not wear personal protective equipment due to a lack of knowledge on the selection of appropriate personal protective equipment and the discomfort they experience when they put on protectors. Even when they put on protective equipment, 38% was inappropriate for the farming work environment. Given the research results, improvements on and the development of specialized working clothing and personal protective equipment to protect farmers from harmful and dangerous materials from the cattle nurturing environment is necessary. Overall, based on the study data, objectified data collection, a determination of the necessary performance elements of personal protective equipment, and R&D will be needed through an on-site current status investigation.

Finite Element Stress Analysis of Implant Prosthesis according to Position and Direction of Load (하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소법적 응력분석)

  • Bae, Sook-Jin;Chung, Chae-Heon;Jeong, Seung-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.4
    • /
    • pp.257-268
    • /
    • 2003
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis according to position and direction of load, under vertical and inclined loading using FEA analysis. The finite element model was designed according to standard fixture (4.1mm restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric usp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant in both vertical and oblique loading but stresses in the cancellous bone were low in both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. 4. The relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 5. The magnitude of the stress in the supporting bone, fixture and abutment screw was greater with the outward oblique loading than with the inward oblique loading and was the greatest under loading at the centric cusp in a $30^{\circ}$ outward oblique direction. Conclusively, this study provides evidence that bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. But it seems to be more important that how long is the distance from center of rotation of the implant itself to the resultant line of force from occlusal contact(leverage). The goal of improving implants should be to avoid bending of the implant.