• Title/Summary/Keyword: 3-Chamber

Search Result 3,208, Processing Time 0.032 seconds

The Differences of Nitrous Oxide (N2O) Emissions as Crop Presence and Location of Gas Sampling Chambers in Upland (밭토양에서 챔버 위치와 작물체 유·무에 따른 아산화질소 배출량 차이 분석)

  • Jeong, Hyun Cheol;Choi, Eun Jung;Lee, Jong Sik;Kim, Gun Yeob;So, Kyu Ho
    • Journal of Climate Change Research
    • /
    • v.7 no.4
    • /
    • pp.427-432
    • /
    • 2016
  • Nitrous oxide is one of the main sources of greenhouse gases and its concentration has increased from 273 ppb in 1,750 to 315 ppb in 2005. Specially, nitrogen fertilizer used in agricultural soils is considered as an important source of atmospheric $N_2O$ emission. This study was conducted to estimate the difference of nitrous oxide emission as chamber position on furrow and ridge and crop existence in gas sampling chamber on upland. Four treatments used in this experiment were (1) no-fertilizer without crop in chamber on ridge, (2) fertilizer application without crop in chamber on ridge, (3) fertilizer application with crop in chamber on ridge, (4) fertilizer application without crop in chamber on ridge and furrow. Nitrous oxide emission at fertilizer application with crop in chamber on ridge were the highest while were the lowest at no-fertilizer without crop in chamber on ridge. There was no significant difference of nitrous oxide emission by chamber position, but total emission by crop existence in chamber was significant difference. Therefore, in order to estimate greenhouse gases emission using chamber method in upland, it should be considered in correlation with crop existence in chamber and characteristic changes like as the soil moisture, microbial flora by crop growth stage.

An Experimental Study for the Improvement of Ventilation Conditions and Effectiveness in the Manufacturing Industry by Increasing the Mixing Factor (K-Factor) (혼합계수(K-Factor) 증가에 따른 사업장의 환기 조건 및 효율 개선에 관한 연구)

  • Lee, Yun-ho;Lee, Seokwon;Lee, Kyoungho;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.343-350
    • /
    • 2019
  • Objectives: This study aims to identify whether ventilation conditions and their effectiveness can be significantly improved in an experimental chamber by increasing the mixing factor (K-Factor). Methods: In a chamber with a volume of $1m^3$, air velocity was measured at six different points with four roof fans in the upper part of the chamber being operated in order. The impact of the ventilation conditions was analyzed when the flow rates were increasing and the first inlet of the chamber was either open or closed. Smoke patterns were also observed at four corner points where ventilation was limited. Kruskal Wallis and Mann-Whitney tests were performed to compare air velocities measured in the chamber. Results: The air velocities measured at only the third point increased significantly from $0.03{\pm}0.03m/s$ (door open) and $0.05{\pm}0.06m/s$ (door closed) with two fans, $0.08{\pm}0.08m/s$ with three fans, and $0.09{\pm}0.09m/s$ with four fans operating (p<0.05). However, air velocities at the four corner points did not significantly increase. Smoke patters also showed that the open inlet of the chamber had no effect on improvement of ventilation conditions and effectiveness. Conclusions: In this study, the air velocities at six points in the chamber did not significantly increase despite the increase in the mixing factor and flow rates of ventilation in the controlled environment. Therefore, the inflow of outdoor air throughout an open inlet and installation of a forced ventilation system can potentially increase the indoor air velocity and improve ventilation condition without an increase in the mixing factor.

Effects of Chamber Pressure on Dielectric Properties of Sputtered MgTiO3 Films for Multilayer Ceramic Capacitors

  • Park, Sang-Shik
    • Korean Journal of Materials Research
    • /
    • v.20 no.7
    • /
    • pp.374-378
    • /
    • 2010
  • $MgTiO_3$ thin films were prepared by r.f. magnetron sputtering in order to prepare miniaturized NPO type MLCCs. $MgTiO_3$ films showed a polycrystalline structure of ilmenite characterized by the appearance of (110) and (202) peaks. The intensity of the peaks decreased with an increase in the chamber pressure due to the decrease of crystallinity which resulted from the decrease of kinetic energy of the sputtered atoms. The films annealed at $600^{\circ}C$ for 60min. showed a fine grained microstructure without micro-cracks. The grain size and roughness of the $MgTiO_3$ films decreased with the increase of chamber pressure. The average surface roughness was 1.425~0.313 nm for $MgTiO_3$ films prepared at 10~70 mTorr. $MgTiO_3$ films showed a dielectric constant of 17~19.7 and a dissipation factor of 2.1~4.9% at 1MHz. The dielectric constant of the films is similar to that of bulk ceramics. The dielectric constant and the dissipation factor decreased with the increase of the chamber pressure due to the decrease of grain size and crystallinity. The leakage current density was $10^{-5}\sim10^{-7}A/cm^2$ at 200kV/cm and this value decreased with the increase of the chamber pressure. The small grain size and smooth surface microstructure of the films deposited at high chamber pressure resulted in a low leakage current density. $MgTiO_3$ films showed a near zero temperature coefficient and satisfied the specifications for NPO type materials. The dielectric properties of the $MgTiO_3$ thin films prepared by sputtering suggest the feasibility of their application for MLCCs.

Experimental Cats Model for Research of the Blood Ocular Barrier

  • Park Byung-Rae
    • Biomedical Science Letters
    • /
    • v.11 no.4
    • /
    • pp.555-559
    • /
    • 2005
  • Evaluate the triolein emulsion could disrupt the barriers and to suggest as an experimental model in blood-ocular barrier studies. Triolein emulsion was infused into the carotid artery in the experimental group ten cats. Normal saline was used in another the control group ten cats. Pre contrast and postcontrast T1-weighted MR images were obtained at 30 minutes and 3 hours after embolization. Signal intensities were evaluated in the anterior, posterior chamber and in the vitreus qualitatively and quantitatively. Postembolization 30 minutes MR images were not different from those of the control group. Postembolization 3 hour MR images demonstrated delayed contrast enhancement in the anterior chamber of the ipsilateral and contralateral eyeballs and in the posterior chamber of the ipsilateral eyeball. Delayed contrast enhancement of the posterior chamber of the ipsilateral eyeball was statistically significant (P<0.05). The present study demonstrated significant contrast enhancement in the posterior chamber with infusion of triolein emulsion and can be a model in blood-aqueous barrier studies.

  • PDF

A Validation Model for the Statistical Power Balance Method Using a Reverberation Chamber

  • Lee, Young Seung;Choi, Sung Woong;Park, Seung Keun
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.3
    • /
    • pp.192-194
    • /
    • 2013
  • This paper proposes a validation model using a reverberation chamber for verification of the effectiveness and accuracy of the statistical power balance (PWB) method. The PWB method treats electromagnetic (EM) field distributions in certain environments as a representative value of an "ensemble" average, so a reverberation chamber is utilized as a testing apparatus to experimentally simulate the sets of measurement field "ensemble" inside a complex environment. Measurements are performed with various test conditions for environmental loss using flat absorbers, and front and side doors of the chamber. Comparison between the PWB analysis and the measurement results shows good agreement, indicating the usefulness of this statistical analysis method for stating the electromagnetic field inside the EM zone as a representative value to general structures.

Study on Combustion Characteristics of Pre-combustion Chamber Type Diesel Engine with Different Throat Shape (예연소실식 디젤엔진의 분구 형상 변화에 따른 연소 특성 연구)

  • Choi, Jonghui;Lee, Seungpil;Park, Sungwook
    • Journal of ILASS-Korea
    • /
    • v.22 no.3
    • /
    • pp.116-121
    • /
    • 2017
  • Pre-combustion chamber type indirect diesel engines have different combustion characteristics compared with those of common rail direct injection engine. The CONVERGE, specific engine CFD program, was used to simulate hollow cone spray model and combustion. The air-fuel mixture flow propagating from pre-combustion chamber to cylinder was concentrated at top half and center of the pre-combustion chamber throat. Stronger mixture flow was formed at smaller and longer throat cases. As a result, thermal efficiency and fuel consumption were improved for modified throat shape and the soot emission was also reduced.

Prediction of transmission loss of parallelepiped plenum chambers with liner (흡음재가 부착된 직방형 소음기의 전달 손실 예측)

  • 김회전;이정권;박철민
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.383-386
    • /
    • 2003
  • This paper deals with transmission loss of 3-dimensional rectangular plenum lined chamber. There are three kinds of rectangular plenum lined chamber: throughflow type, flow-reversal type, and end-in/side-out type. The combination of above three types of rectangular plenum lined chamber is used for the commercial HVAC system and automobile exhaust system. However, the ambiguity and complexity of sound absorbing material property and 3-dimensional property have impeded research. In this paper, the transmission loss of three kinds of rectangular plenum lined chamber is derived and calculated. The effect of increase of sound absorbing material is also considered. Analytical solution is calculated by using the locally-reacting property of sound absorbing material.

  • PDF

Optimization of the Material and Structure of Component Parts for Reducing the Number of Impurity Particles in CVD Process

  • Kim, Won Kyung;Woo, Ram;Roh, Jong Wook
    • Journal of the Korean Ceramic Society
    • /
    • v.56 no.3
    • /
    • pp.277-283
    • /
    • 2019
  • We have examined minimization of the number of impurity particles by replacing the load-lock chamber materials of the chemical vapor deposition equipment through optimization of the pumping method in the deposition chamber. In order to reduce the number of impurity particles in the chamber, the load-lock spacer material was changed from monomer casting nylon to Torlon. Furthermore, we controlled the pumping speed and number of pumping ports, which resulted in a reduction in the impurity particle generation from 2.67% to 0.52%. This study revealed that the selection of the material for the parts of a chemical vapor deposition chamber can minimize particle generation, thereby presenting a method of optimization method of the chemical vapor deposition chamber.

A STUDY ON THE ANAOMY OF THE PULP CHAMBER FLOOR OF THE PERMANENT MAXILLARY FIRST MOLAR (상악(上顎) 제일대구치(第一大臼齒) 치수저(齒髓底)의 해부학적(解剖學的) 고찰(考察))

  • Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.6 no.1
    • /
    • pp.105-107
    • /
    • 1980
  • A total of 125 extracted maxillary first molars were used to study the configuration of the floor of the pulp chamber. The specimens were ground and the pulp chamber was examined with a magnifying glass and explored with sharp explorer. The study showed the shape of the pulp chamber, number of root canals, and type of canal orifice. The results were as follows; 1. In so far as observing the shape of the pulp chamber of the teeth, 50.4% of the teeth were trapezoid, 20.8% were inverted trapezoid, 18.4% were rectangle and 10.4% were triangle shape. 2. 71.2% of the specimens have 3 root canal orifices, and 28.8% have 4 root canal orifices. 3. 71.2% of the specimens have 1 mesiobuccal canal orifice, 23.2% have 2 mesio-buccal canal orifices joined by a groove, and 5.6% have 2 mesio-buccal canal orifices seperated each other.

  • PDF

Experimental Study of Shape Parameter of Land-based OWC Wave Energy Converter (고정식 진동 수주형 파력 발전기(OWC) 형상 파라미터의 실험 연구)

  • Koo, Weon-Cheol;Kwon, Jin-Sung;Kim, Jun-Dong;Kim, Sung-Jae;Kim, Min-Woo;Choi, Mun-Kwan
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.33-38
    • /
    • 2012
  • The aim of this experimental study was to analyze the effect of the shape parameters and chamber pressure of a land-based oscillating water column (OWC) in regular incident waves. The magnitude of the free surface elevations inside the chamber was measured in a two-dimensional wave tank for various chamber skirt drafts and bottom slope angles. The surface elevations were also measured under both open chamber and partially open chamber conditions. From these measurements, the optimum shape of the OWC device could be predicted for the maximum wave energy conversion efficiency. It was found that the resonance frequency of the OWC system associated with incident waves moved toward the long wave region with increments of the draft of the chamber skirt and bottom slope. The behavior of the free surface elevation inside the chamber was also found to be dependent on the chamber pressure.