• 제목/요약/키워드: 3 dimensional camera

검색결과 526건 처리시간 0.024초

낙하 착지 시 FRT가 하지의 관절의 시상각과 강직도에 미치는 효과 (The Effects of Fibular Repositioning Taping on Joint Angle and Joint Stiffness of the Lower Extremity in Sagittal Plane during a Drop Landing)

  • Jun, Hyung-pil
    • 한국운동역학회지
    • /
    • 제31권4호
    • /
    • pp.276-282
    • /
    • 2021
  • Objective: To investigate effects of Fibular Repositioning Taping (FRT) on lower extremity joint stiffness and angle during drop-landing. Method: Twenty-eight participants (14 healthy, 14 with chronic ankle instability [CAI]) performed drop-landings from a 60 cm box; three were performed prior to tape application and three were performed post-FRT. Three-dimensional kinematic and kinetic data were collected using an infrared optical camera system (Vicon Motion Systems Ltd. Oxford, UK) and force-plate (AMTI, Watertown, MA). Joint stiffness and sagittal angle of the ankle, knee, and hip were analyzed. Results: The hip [Healthy: p<.05; M ± SD: 29.43 ± 11.27 (pre), 33.04 ± 12.03 (post); CAI: p<.05; M ± SD: 31.45 ± 9.70 (pre), 32.29 ± 9.85 (post)] and knee [Healthy: p<.05; M ± SD: 53.44 ± 8.09 (pre), 55.13 ± 8.36 (post); CAI: p<.05; M ± SD: 53.12 ± 8.35 (pre), 55.55 ± 9.81 (post)] joints demonstrated significant increases in sagittal angle after FRT. A significant decrease in joint angle was found at the ankle [Healthy: p<.05; M ± SD: 56.10 ± 3.71 (pre), 54.09 ± 4.31 (post); CAI: p<.05; M ± SD: 52.80 ± 6.04 (pre), 49.86 ± 10.08 (post)]. A significant decrease in hip [Healthy: p<.05; M ± SD: 1549.16 ± 517.53 (pre), 1272.48 ± 646.73 (post); CAI: p<.05; M ± SD: 1300.42 ± 595.55 (pre), 1158.27 ± 550.58 (post)] and knee [Healthy: p<.05; M ± SD: 270.12 ± 54.07 (pre), 239.13 ± 64.70 (post); CAI: p<.05; M ± SD: 241.58 ± 93.48 (pre), 214.63 ± 101.00 (post)] joint stiffness was found post-FRT application, while no difference was found at the ankle [Healthy: p>.05; M ± SD: 57.29 ± 17.04 (pre), 59.37 ± 18.30 (post); CAI: p>.05; M ± SD: 69.15 ± 17.63 (pre), 77.24 ± 35.05 (post)]. Conclusion FRT application decreased joint angle at the ankle without altering ankle joint stiffness. In contrast, decreased joint stiffness and increased joint angle was found at the hip and knee following FRT. Thus, participants utilize an altered shock absorption mechanism during drop-landings following FRT. When compared to previous research, the joint kinematics and stiffness of the lower extremity appear to be different following FRT versus traditional ankle taping.

방사광 전파위상대조 동결미세단층촬영법을 활용한 3차원 조직학 (3D Histology Using the Synchrotron Radiation Propagation Phase Contrast Cryo-microCT)

  • 김주헌;한성미;송현욱;서윤경;문용석;김홍태
    • 해부∙생물인류학
    • /
    • 제31권4호
    • /
    • pp.133-142
    • /
    • 2018
  • 조직표본의 실제적인 3차원 구조에 대한 정보를 3차원 조직학이라고 하였다. 무른 성분들이 섞여 있고, 물을 포함 하고 있는 조직 내부의 미세구조의 3차원적 분석을 위해 방사광의 X선을 광원으로 하는 위상대조 미세단층 촬영이 활용되고 있다. 하지만, X선 위상대조영상 분석에서 물을 포함하고 있는 조직에서는 위상대조가 제대로 구현되지 않다는 것을 알게 되었다. 이러한 현상을 해결하기 위해 다양한 방법들을 적용하였으며, 표본을 얼렸을 때 위상대조가 강화된다는 사실을 확인하였다. 방사광 전파위상대조 동결미세단층촬영은 포항가속기연구소 X선 영상빔라인에서 수행하였다. 표본을 동결상태로 유지하면서 $0.18^{\circ}$ 간격으로 $180^{\circ}$ 회전하였으며, 표본을 통과한 X선에 의해 섬광기에 맺힌 영상을 광학렌즈로 확대하여 CCD카메라로 모았다. 각 표본 전체 투사영상을 OCTOPUS 소프트웨어로 재구성하여 2차원 단면영상으로 만들고, Amira 소프트웨어를 이용하여 3차원 영상으로 재구성하였으며, 단면영상에서 각 구조에 대한 구역화와 랜더링 작업을 수행하였다. 물에 의한 위상대조 방해 영향을 줄이기 위해 표본을 얼렸을 때 위상대조는 강화되었으나 동결팽창에 의한 조직변형이 관찰되었다. 표본을 막힌 공간에 넣고 주위를 포매제로 채워 급속냉동 동안 표본이 압박되도록 하였을 때 위상대조의 강화와 동결팽창에 의한 조직변형을 줄일 수 있었다. 결론적으로, 생체조직 내부 미세구조의 비파괴, 고해상도 3차원 영상분석에 있어 조직표본을 동결포매제로 포매 후 급속냉동하고, 방사광에서 방출되는 X선을 광원으로 하는 전파위상대조 동결미세단층촬영법은 효과적인 방법이 될 수 있을 것으로 기대한다.

유도 맞잡기 타입에 따른 허벅다리걸기의 Kinematic 분석[I] (A Kinematic Analysis of Uchi-mata(inner thigh reaping throw) by Kumi-kata types in Judo)

  • 김의환;조동희;권문석
    • 한국운동역학회지
    • /
    • 제12권1호
    • /
    • pp.63-87
    • /
    • 2002
  • The purpose of this study was to analyze the kinematic variables when Uchi-mata(inner thigh reaping throw) performing by Kumi-kata(engagement position, basic hold) types A, B(A: grasping part-behind neck lapel, B: chest lapel) in Judo with three dimensional analysis technique DLT method by videography. The subjects were four male judokas who have been training in Yong-In University(YIU), on Korean Representative level and Uchi-mata is their tokui-nage(favorite technique), the throwing form was filmed on two S-VHS 16mm video camera( 30frame/sec. Panasonic). Kinematic variables were temporal, posture, and COG. The data collection was performing by Uchi-mata. Six good trials were collected for each condition (type A, B) among over 10 trials. The mean values and the standard deviation for each variable were obtained and used as basic factors for examining characteristics of Uchi-mata by Kumi-kata types. The results of this analysis were as follows : 1) Temporal variables The total time elapsed(TE) by Uchi-mata of types A, B were 1.45, 1.56 sec. respectively. Types A shorter than B. 2) Posture variables In performing of Uchi-mata, the range of flexion in type A, left elbow was $45^{\circ}$ and B was $89^{\circ}$ from Event 2(E2) to Event 6(E6). Type A and B were quite different in right elbow angle in Event1(E1). Left shoulder angle of type A was extended and type B was flexed in E4. Both types right shoulder angles were showed similar pattern. Also both hip angles(right/left) were showed similar pattern. When type A performed Uchi-mata the knee-angle of supporting foot showed $142^{\circ}$in the 1st stage of kake phase[KP], and extended to $147^{\circ}$in the 2nd stage of KP. And the foot-ankle angle of supporting foot showed $83^{\circ}$in the 1st stage of KP, and extended to $86^{\circ}$in the 2nd stage of KP. moreover, The knee angle of attacking foot showed $126^{\circ}$in the 1st stage of KP, and extended to $132^{\circ}$in the 2nd stage of KP, and the foot-ankle angle of attacking foot showed $106^{\circ}$in the 1st stage of KP, and extended to $121^{\circ}$in the 2nd stage of KP. When type B performed Uchi-mata the knee-angle of supporting foot showed $144^{\circ}$in the 1st stage of KP, and extended to $154^{\circ}$in the 2nd stage of KP. And the foot-ankle angle of supporting foot showed $83^{\circ}$in the 1st stage of KP, and extended to $92^{\circ}$in the 2nd stage of KP. moreover, The knee angle of attacking foot showed $132^{\circ}$in the 1st stage of KP, and extended to $140^{\circ}$in the 2nd stage of KP, and the foot-ankle angle of attacking foot showed $103^{\circ}$in the 1st stage of KP, and extended to $115^{\circ}$in the 2nd stage of KP. During Uchi-mata performing, type A showed pulling pattern and type B showed lift-pulling pattern. As Kumi-kata types, it were different to upper body(elbow, shoulder angle), but mostly similar to lower body(hip, knee, ankle angle) on both types. 3) C. O. G. variables When the subjects performed Uchi-mata, COG of type A, B up and down in vertical aspect was 71cm, 73.8cm in height from the foot in the 2nd stage of KP. As Kumi-kata types, it were different on medial-lateral direction aspect but weren't different in Kuzushi phase on vertical direction aspect.

하악 편측 유리단 가철성 국소의치의 설계에 따른 광탄성 응력 분석 (Photoelastic stress analysis of the mandibular unilateral free-end removable partial dentures according to the design)

  • 박철우;계기성
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.206-214
    • /
    • 2009
  • 연구목적: 하악 우측 제1, 2 대구치가 결손된 Kennedy 분류 II급 증례에서 임상적으로 적용할 수 있는 편측 유리단 가철성 국소의치의 종류에 따른 응력 분포 양상을 비교하는 것이다. 연구 재료 및 방법: Kennedy 분류 II급 증례의 광탄성 모형에서 클라스프를 이용한 국소의치, 코너스 치관을 이용한 국소의치, 완압형 어태치먼트를 이용한 국소의치, 탄성 레진을 이용한 국소의치를 편측성으로 제작하였다. 응력 동결로에서 응력 주기에 맞춰 각 국소의치의 제1 대구치 중심와에 6 kg의 수직하중을 가하면서 응력을 동결하였다. 광탄성 모형을 절단하여 만든 시편을 광탄성 실험 장치로 광탄성 등색선의 흑백 무늬를 관찰하고 디지털 카메라로 촬영하였다. 촬영된 사진에서 8개의 측정점을 정하여 육안으로 무늬차수를 계측하고 비교하였다. 결과: 각 절단 시편의 최대 무늬차수와 하중점 직하방의 잔존 치조제에 발생한 무늬차수는 탄성 레진을 이용한 국소의치, 클라스프를 이용한 국소의치, 완압형 어태치먼트를 이용한 국소의치, 코너스 치관을 이용한 국소의치 순으로 높게 관찰되었다. 제2 소구치 치근단에 발생한 무늬차수는 클라스프를 이용한 국소의치, 탄성 레진을 이용한 국소의치, 코너스 치관을 이용한 국소의치, 완압형 어태치먼트를 이용한 국소의치 순으로 높게 관찰되었다. 결론: 코너스 치관을 이용한 국소의치가 수직하중시 지대치 주위 치조골과 잔존 치조제에 대하여 응력을 가장 균형있게 분산시켰고, 탄성 레진을 이용한 국소의치는 지대치보다 잔존 치조제의 상태가 더 양호한 경우에 적용 가능할 것이다.

유적탐색을 위한 드론과 항공사진의 활용방안 연구 (A study on the utilization of drones and aerial photographs for searching ruins with a focus on topographic analysis)

  • 허의행;이왈영
    • 헤리티지:역사와 과학
    • /
    • 제51권2호
    • /
    • pp.22-37
    • /
    • 2018
  • 현재 국내 및 국외를 아울러 무인항공기(Unmanned Aerial Vehicle, UAV)의 관심이 상당히 높아졌다. UAV에는 영상을 촬영하는 카메라가 탑재되어 있어 고고학 조사가 불가능한 지역의 접근에 유리하다. 더구나 항공사진 촬영을 통해 지형을 모델링하여 3차원 공간영상정보를 취득할 수 있어, 조사 대상지역의 지형에 대한 해석을 구체화할 수 있다. 이와 함께 과거 항공사진과의 비교 검토를 통해 지형의 변화모습을 파악한다면 유적의 존재 여부의 파악에도 많은 도움이 될 것이다. 이러한 유적 탐색을 위한 지형모델링은 크게 두 부분으로 나누어 접근할 수 있다. 우선 드론을 이용한 현재 지형의 항공사진을 취득한 후 이를 영상정합하고 후처리 과정을 진행하여 완성하는 방법과 과거 항공사진을 이용한 영상접합과 지형모델링을 완성하는 방법 등이다. 이 과정을 거쳐 완성한 모델링 지형은 여러 분석결과를 도출할 수 있는데, 현재의 지형모델링에서는 DSM과 DTM, 고도분석 등의 지형분석을 실시하여 형질변경 및 미지형의 모습을 대략적으로 파악할 수 있고, 과거 항공사진의 지형모델링에서는 원지형과 저습지 내 매몰미지형의 모습 등을 파악할 수 있다. 이를 실제 조사된 내용과 비교하고 각각의 지형모델링 자료를 중첩하여 살펴보게 되면 구릉지형에서는 형질변경의 모습을, 저습지형에서는 매몰된 미지형의 모습을 볼 수 있어 유적의 존부를 파악하는데 매우 유용하게 사용될 수 있다. 이처럼 항공사진을 이용한 모델링 자료는 고고학현장에서 조사가 불가한 사유지나 광범위한 지역의 지형에 유적의 존재여부를 파악하는데 유용하며, 추후 유적의 보존처리와 관련한 논의에도 적극 이용될 수 있다. 나아가 과거와 현재의 지형자료의 비교를 통해 지적도나 토지활용도 등의 주제도로 제공이 가능하는 등, 다양한 방식으로의 활용 가능성을 생각할 수 있다. 그러나 무엇보다도 고고학 자료의 존재유무 파악을 위한 유적 탐색의 새로운 조사방법론으로 기능할 수 있다.

전동화일로 형성된 근관에서 비표준화 Gutta-percha Cone의 적합성 (APICAL FITNESS OF NON-STANDARDIZED GUTTA-PERCHA CONES IN SIMULATED ROOT CANALS PREPARED WITH ROTARY ROOT CANAL INSTRUMENTS)

  • 권오상;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.390-398
    • /
    • 2000
  • 근관형성을 위해 표준화된 근관형성기구에 비해 taper가 큰 기구들이 사용되고 있으며 이를 이용하여 형성된 근관은 taper가 큰 근관의 모양을 갖는다. 근관충전방법에 있어 근관의 크기에 적합한 1차적 gutta-percha cone을 선택할 필요가 있다. 본 연구에서는 .04 및 .06 taper의 전동화일로 형성된 근관에 열연화충전법을 위해 가장 적합한 1차 cone을 선택하기 위한 지침 마련의 목적으로, 근단공의 크기와 근관의 taper에 따른 gutta-percha cone의 근단부 근관 내 적 합도를 평가하였다. ProFile$^{(R)}$ .04 taper와 .06 taper를 이용하여 Crown down 방법으로 60개의 모형근관을 형성하였다. 표준화 gutta-percha cone, Dia-Pro ISO-.04$^{TM}$ 및 .06 gutta-percha cone, MF, F, FM 및 M 크기의 비표준화 gutta-percha cone의 근관 내 적합도는 치근단 5mm의 근관면적에 대한 gutta-percha cone의 점유 면적비(%)로 하였다. .04 taper, 25번 크기의 근관에서는 F, MF 크기의 비표준화 cone이 표준화 cone과 Dia-Pro 180-.04$^{TM}$ 보다 우수한 근관적합도를 나타내었고(p<0.05), 30번 크기의 근관에서는 F, Dia-Pro ISO-.04$^{TM}$, FM 크기의 gutta-percha cone 모두 표준화 cone보다 우수한 근관적합도를 나타내었으나(p<0.05), 35번 크기의 근관에서는 모든 gutta-percha cone 사이에 유의한 차이를 나타내지 않았다(p>0.05) .06 taper, 25번 크기의 근관에서는 사용된 비표준화 cone 모두가 표준화 cone, Dia-Pro ISO-.06$^{TM}$ 보다 나은 근관적합도를 나타내었고(P<0.05), 30번 크기의 근관에서는 표준화 cone을 제외한 나머지 gutta-percha cone에서 유의한 차이를 발견할 수 없었다. 35번 크기의 근관에는 M 크기의 비표준화 cone이 가장 우수한 근관적합도를 보이고 있는 것으로 나타났으며, FM과 Dia-Pro ISO-.06$^{TM}$ 사이에서는 유의한 차이가 나타나지 않았다(p>0.05).

  • PDF