• Title/Summary/Keyword: 3 표준 정지기

Search Result 39, Processing Time 0.02 seconds

A Study on the Characteristic of Power Consumption and Design of the Electrical Installations for the Inverter Controlled Elevator (인버터제어 승강기의 전력소비 특성과 전원설비 계획에 관한 연구)

  • 이기홍;성세진
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.2
    • /
    • pp.57-63
    • /
    • 2001
  • This paper analysed the characteristic of Power consumption at many type of Inverter controlled Elevator. Especially, this paper proposed the standard value of full load currents. For this propose, it was classified by the passenger capacity and manufacture company. As a result, it is found that (i) the value is between -3[A] and 7[A] in case of elevator. That means the full load currents was smaller than the standard value of conventional operation type (ii) the value is between 0.5[kVA] and 3[kVA] in case of Power transformer. That means the transformer capacity was smaller than the standard value of conventional operation type. it was classified by the passenger capacity at inverter controlled elevator in apartment Also, to guarantee the operation stop of inverter controlled elevator, this paper proposed the redundancy method of electrical installations. the redundancy method is (i) 2 line service system and (ii) 2 distribution line system.

  • PDF

Changes in Growth Characteristics of Waxy Corn 'Ilmichal' due to Low Temperature during the Seedling Stage (일미찰옥수수의 유묘기 저온에 따른 생육특성 변화)

  • Jeon, Seung Ho;Oh, Seung Ka;Kim, Han Yong;Na, Chae-In;Bae, Hui Su;Cho, Young Son
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.65 no.4
    • /
    • pp.426-435
    • /
    • 2020
  • To determine the damages to waxy corn caused by low temperature weather, we investigated the relationship between the temperature and duration of low temperature treatment and the changes in growth characteristics during the recovery period after the treatments in different growth periods. Growth inhibition started in the low temperature group treated at temperatures below 5℃ for three days. The inhibition ratio (IR) was more than 22% or more in all sample groups. As the treatment duration increased and the Temperature decreased, the growth was more greatly inhibited than that in the control. The IR was the highest at 27% or more in the 2nd leaf stage group treated at below 5℃ for 5 days. The IR was in the order of 2nd leaf stage > 1st leaf stage > coleoptile. The IR during recovery was the highest in the 2nd leaf stage group treated at -3℃ degree for 7 days, nd the values were 82% and 98% for NDVI and Fv/Fm, respectively. Especially, all groups treated at -3℃ showed either no changes or decreases in the growth characteristics. As a result, growth inhibition increased as the temperature decreased, and as the duration of the low temperature increased. The degree of damage was in the order of 2nd leaf stage > 1st leaf stage > coleoptile. All early seedlings stopped growing and withered when exposed to temperatures at or below -3℃ for 3 days or more.

Relation of the Fertility and Grain Weight of Wheat and Barley to their Spike Differentiation and Development (대소맥에 있어서 소수 및 소화의 분화, 발육정도가 임성 및 립중에 미치는 영향)

  • 남윤일;하용웅
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.27 no.2
    • /
    • pp.116-122
    • /
    • 1982
  • In three diverse wheat and one barley cultivars were used to examine the relation of the spikelet and floret differentiation to fertility and an winter wheat Norin 61 was used to examine the spikelet size gradients in the mature ear in relation to their grain development. The greatest number of grains and florets per spikelet, and the heaviest grains occurred in the low-mid part of the ear. Within the spikelets, the 2nd grain from the base was heavier than the I st or the 3rd one. In this region, the fertility of the 1 st floret was 97%, the 2nd 93%, the 3rd 88%, and 4th floret was 15%. The fertility of the wheat and barley was closely related to spikelet and floret differentiation. Barley spikelets was fertile as their differentiation stage was X that is 25 days before heading. Wheat florets were fertile as their differentiation stage was X that is 15-20 days before heading. But, they were sterile or reduced in fertility if they were not reached to the stage X.

  • PDF

Development of the Traffic Signal Control Strategy and Signal Controller for Tram (트램 운영을 위한 신호제어 전략 및 신호제어기의 개발)

  • Lee, In-Kyu;Kim, Youngchan;Lee, Joo Il;Oh, Seung Hwoon
    • Journal of Korean Society of Transportation
    • /
    • v.33 no.1
    • /
    • pp.70-80
    • /
    • 2015
  • In recent years, tram has been the focus of a new mode of public transportation that can solve traffic jams and decrease public transit usage and environmental problem. This research is in the works to develop a tram signal controller and signal control strategies, and aim to resolve the problem of what could happen if a tram system was installed in general road. We developed the hierarchical signal control strategies to obtain a minimum tram bandwidth and to minimize vehicle delay, in order to perform a priority control to include passive and active signal priority control strategies. The strategies was produced for S/W and H/W, it is based in standard traffic signal controller. We conducted a micro simulation test to evaluate the hierarchical signal control strategies, which showed that the developed optimization model is effective to prevent a tram's stop in intersection, to reduce a tram's travel time and vehicle's delay.

Isolation and Characterization of Lactic acid bacteria Leuconostoc mesenteroides DB3 from Camellia japonica Flower (백꽃으로부터 분리한 Leuconostoc mesenteroides DB3의 특성)

  • Sam Woong Kim;Da Hye Shin;Sang Wan Gal;Kyu Ho Bang;Da Som Kim;Won-Jae Chi
    • Journal of Life Science
    • /
    • v.33 no.11
    • /
    • pp.915-922
    • /
    • 2023
  • Lactic acid bacteria (LAB) are widespread in a variety of environments including fermented dairy products, gastroinstetinal and urogenital tracts of human and animals, plant, soil and water. Leuconostoc mesenteroides DB3 was detected by the strongest antibacterial activities among 24 Leuconostoc strains isolated from Camellia japonica flowers. Acid tolerance of L. mesenteroides DB3 existed up to pH 2.5, but the resistance did not show at pH 2.0, which relatively excellent acid resistance existed. Bile acid tolerance was very stable within the test range to 1.2%. L. mesenteroides DB3 exhibited the optimal growth at 30℃, and showed a slight slow growth when compared with L. mesenteroides KCTC3505, which reached a stationary phase at 18 hr. The pH was changed along with the growth curve, but was maintained above pH 3.98. L. mesenteroides DB3 had higher initial antibacterial activities when compared to L. mesenteroides KCTC3505, but it showed similar activities with the standard strain after the latter part of the logarithmic growth phase. Although lactic acid production in L. mesenteroides DB3 was induced by lower amount in the initial part to the standard strain, it was exhibited by similar amounts after the late logarithmic growth phase. Muicin adhesion of L. mesenteroides DB-3 maintained superior to L. mesenteroides KCTC3505. Both strains showed excellent emulsification ability for kerosene. In summary, we evaluate that L. mesenteroides DB-3 has a high potential for application as probiotics owing to its excellent antibacterial activity, acid resistance, bile acid resistance, and muicin adhesion.

An Analysis of the Loss of Residual Heat Removal System Event for Pressurized Water Reactor at Reduced Inventory Operation (가압경수로의 저수위 운전시 잔열제거계통 상실사고에 대한 분석)

  • Han, Kee-Soo;Song, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.645-660
    • /
    • 1995
  • The loss of Residual Heat Removal System (RHRS) event during reduced inventory operation for the Korean Standard Nuclear Power Plants (KSNPPS) is simulated by RELAP5/MOD3 and RELAP5/MOD3.1 Tn cases are considered : Base case for an intact Reactor Coolant System (RCS) with no tent and a vent case for an open system. Comparative simulations of base case are peformed by RELAP5/MOD3 and RELAP5/MOD3. 1 computer codes. The results of too simulations are generally in good qualitative and quantitative agreement. However, since the results of RELAP5/MOD3 simulation reveals the deficiency of RELAP5/MOD3 wall heat model, the RELAP5/AOD3.1 computer code is used for the simulation of the vent case. The analysis result of base case show that two steam generators are insufficient to remove decay heat at one day after shutdown, where the RCS is closed. The RCS pressure increased continuously and reached the RCS temporary boundaries design pressure of 0.24 MPa around 4,000 seconds. In the vent case with a flow capacity equivalent to three times the capacity of Pressurizer Safety Valve (PSV), it is shown that the RCS Pressure does not reach 0.24 MPa and core uncovery does not occur until 10,000 seconds. The detailed discussions on the results of this study suggest the feasibility of RELAP5/AOD3.1 as an analysis tool for the simulation of the loss of RHRS event at reduced inventory operation. The results of this study also provide insight for the determination of proper vent capacity.

  • PDF

$\alpha$-$\beta$Current and Power Components Analysis of Instantaneous Power Theory Using MATLAB/SIMULINK (MATLAB/SIMULIN에 의한 순시전력이론의 $\alpha$-$\beta$ 전류 및 전력성분 해석)

  • 정영국;임영철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.88-96
    • /
    • 2000
  • The instantaneous power theory have been considered as efficient theory in recent years, because it is easier to understand numerical representation and more soft to control PWM power converter on $\alpha$-$\beta$ stationary reference frame. From the forgoing theory, with regard to the calculating process of compensating reference current, there are many induced components of current/ power, and these components have consequently influence on physical interpretation of instantaneous power theory. Especially, beginners for studing the instantaneous power theory don't have enough informations for standard waveform of induced $\alpha$-$\beta$ components. Therefore, this paper describes simulation works using MATLAB/SIMULINK for $\alpha$-$\beta$ space trajectories and waveforms of $\alpha$-$\beta$ current and power components, induced from the instantaneous power theory. It is respected that the results in this paper are serviceable as basic information to assist beginner for studing the instantaneous power theory.

  • PDF

An Improvement of Still Image Quality Based on Error Resilient Entropy Coding for Random Error over Wireless Communications (무선 통신상 임의 에러에 대한 에러내성 엔트로피 부호화에 기반한 정지영상의 화질 개선)

  • Kim Jeong-Sig;Lee Keun-Young
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.3 s.309
    • /
    • pp.9-16
    • /
    • 2006
  • Many image and video compression algorithms work by splitting the image into blocks and producing variable-length code bits for each block data. If variable-length code data are transmitted consecutively over error-prone channel without any error protection technique, the receiving decoder cannot decode the stream properly. So the standard image and video compression algorithms insert some redundant information into the stream to provide some protection against channel errors. One of redundancies is resynchronization marker, which enables the decoder to restart the decoding process from a known state in the event of transmission errors, but its usage should be restricted not to consume bandwidth too much. The Error Resilient Entropy Code(EREC) is well blown method which can regain synchronization without any redundant information. It can work with the overall prefix codes, which many image compression methods use. This paper proposes EREREC method to improve FEREC(Fast Error-Resilient Entropy Coding). It first calculates initial searching position according to bit lengths of consecutive blocks. Second, initial offset is decided using statistical distribution of long and short blocks, and initial offset can be adjusted to insure all offset sequence values can be used. The proposed EREREC algorithm can speed up the construction of FEREC slots, and can improve the compressed image quality in the event of transmission errors. The simulation result shows that the quality of transmitted image is enhanced about $0.3{\sim}3.5dB$ compared with the existing FEREC when random channel error happens.

Measles Specific IgG in Adolescents (청소년기의 홍역 특이 IgG)

  • Yoon, Jae Kyun;Shin, Young Kyoo;Lee, Kee Hyoung;Choung, Ji Tae;Tockgo, Young Chang
    • Pediatric Infection and Vaccine
    • /
    • v.4 no.1
    • /
    • pp.133-139
    • /
    • 1997
  • Purpose : To determine the age-specific seropositivity and the level of measles specific IgG in vaccinated adolescents, the measles specific IgG titers were measured from the sera of junior & senior high school students in Seoul, Korea. Methods : From May to July in 1996, 216 sera were collected from junior & senior high school students(male : 110, female : 106) aged 12 to 17 years who were vaccinated and had no history of natural measles. Measles specific IgG titers were measured using ELISA method($SIA^{TM}$ Measles IgG Kit, Sigma Co. St. Louis, Mo). Results : The seropositivity of measles specific IgG in vaccinated adolescents aged 12 to 17 years was 91.2%. There were no significant correlations between age and seropositivity as well as between age and measles specific IgG level. Conclusions : We consider that our data suggest the necessity of revaccination of measles in adolescents. Further considerations should be required to establish an appropriate revaccination method and to evaluate the efficacy of revaccination of previously vaccinated adolescents.

  • PDF

Dynamic Behavior of Reactor Internals under Safe Shutdown Earthquake (안전정기지진하의 원자로내부구조물 거동분석)

  • 김일곤
    • Computational Structural Engineering
    • /
    • v.7 no.3
    • /
    • pp.95-103
    • /
    • 1994
  • The safety related components in the nuclear power plant should be designed to withstand the seismic load. Among these components the integrity of reactor internals under earthquake load is important in stand points of safety and economics, because these are classified to Seismic Class I components. So far the modelling methods of reactor internals have been investigated by many authors. In this paper, the dynamic behaviour of reactor internals of Yong Gwang 1&2 nuclear power plants under SSE(Safe Shutdown Earthquake) load is analyzed by using of the simpled Global Beam Model. For this, as a first step, the characteristic analysis of reactor internal components are performed by using of the finite element code ANSYS. And the Global Beam Model for reactor internals which includes beam elements, nonlinear impact springs which have gaps in upper and lower positions, and hydrodynamical couplings which simulate the fluid-filled cylinders of reactor vessel and core barrel structures is established. And for the exciting external force the response spectrum which is applied to reactor support is converted to the time history input. With this excitation and the model the dynamic behaviour of reactor internals is obtained. As the results, the structural integrity of reactor internal components under seismic excitation is verified and the input for the detailed duel assembly series model could be obtained. And the simplicity and effectiveness of Global Beam Model and the economics of the explicit Runge-Kutta-Gills algorithm in impact problem of high frequency interface components are confirmed.

  • PDF