• Title/Summary/Keyword: 3 차원 스캐너

Search Result 306, Processing Time 0.027 seconds

A Study On the Accuracy Analysis of 3-Dimensional Position using Digital Image (수치 영상을 활용한 3차원 위치 정확도 해석)

  • Yeu, Bock-Mo;Sohn, Duk-Jae;Yom, Jae-Hong;Baek, Sang-Ho
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.3 no.2 s.6
    • /
    • pp.159-172
    • /
    • 1995
  • This study aims to apply digital photogrammetric methods on the close range photogrammetry. To get a three dimensional position with digital photogrammetric method, scanning, image matching, and bundle adjustment are performed. Comparing the three dimensional position computed by digital photogrammetric methods with ground survey values, the errors can be detected. Analyzing the errors, it is possible to present a new digital photogrammetric method for the close range photogrammetry. Image matching method used in this study is area-based pixel unit and subpixel unit method. As a result of the study, three dimensional position error is 3.32mm and the error in the single coordinate axis direction is 0.76mm in pixel unit and in subpixel unit, respective error is 3.98mm and 0.73mm.

  • PDF

3D Face Recognition using Local Depth Information

  • 이영학;심재창;이태홍
    • Journal of KIISE:Software and Applications
    • /
    • v.29 no.11
    • /
    • pp.818-825
    • /
    • 2002
  • Depth information is one of the most important factor for the recognition of a digital face image. Range images are very useful, when comparing one face with other faces, because of implicating depth information. As the processing for the whole fare produces a lot of calculations and data, face images ran be represented in terms of a vector of feature descriptors for a local area. In this paper, depth areas of a 3 dimensional(3D) face image were extracted by the contour line from some depth value. These were resampled and stored in consecutive location in feature vector using multiple feature method. A comparison between two faces was made based on their distance in the feature space, using Euclidian distance. This paper reduced the number of index data in the database and used fewer feature vectors than other methods. Proposed algorithm can be highly recognized for using local depth information and less feature vectors or the face.

Analysis of the Accuracy of the UAV Photogrammetric Method using Digital Camera (디지털 카메라를 이용한 무인항공 사진측량의 정확도 분석)

  • Jung, Sung-Heuk;Lim, Hyeong-Min;Lee, Jae-Kee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.6
    • /
    • pp.741-747
    • /
    • 2009
  • For construction of 3D virtual city models, airborne digital cameras, laser scanners, multi-oblique photograph systems and other devices are currently being used. With such advanced techniques, precise 3D spatial information can be collected and high quality 3D city models can be built in a considerably large area. The 3D spatial information to be built has to provide the latest information that quickly reflects the causes of any change due to urban development. In this study, a UAV photogrammetric method using low cost UAV and digital camera was proposed to acquire and update 3D spatial information effectively on small areas where information continuously change. In the proposed UAV photogrammetric method, the elements of interior orientation were acquired through camera calibration and the vertical and oblique photographs were taken at 9 points and the 3D drawing of ground control points and buildings was performed using 20 images among the pictured images. This study also analyzed the accuracy of the proposed method comparing with ground survey data and digital map in order to examine whether the method can be used in on-demand 3D spatial information update on relatively small areas.

Multi-core-based Parallel Query of 3D Point Cloud Indexed in Octree (옥트리로 색인한 3차원 포인트 클라우드의 다중코어 기반 병렬 탐색)

  • Han, Soohee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.4
    • /
    • pp.301-310
    • /
    • 2013
  • The aim of the present study is to enhance query speed of large 3D point cloud indexed in octree by parallel query using multi-cores. Especially, it is focused on developing methods of accessing multiple leaf nodes in octree concurrently to query points residing within a radius from a given coordinates. To the end, two parallel query methods are suggested using different strategies to distribute query overheads to each core: one using automatic division of 'for routines' in codes controlled by OpenMP and the other considering spatial division. Approximately 18 million 3D points gathered by a terrestrial laser scanner are indexed in octree and tested in a system with a 8-core CPU to evaluate the performances of a non-parallel and the two parallel methods. In results, the performances of the two parallel methods exceeded non-parallel one by several times and the two parallel rivals showed competing aspects confronting various query radii. Parallel query is expected to be accelerated by anticipated improvements of distribution strategies of query overhead to each core.

Inspection of Composite Working Implement of Tractor using 3D Scanning and Reverse Design (3차원스캐닝과 역설계를 이용한 트랙터 복합작업기 치수 검사)

  • Lee, Choong-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.3
    • /
    • pp.45-53
    • /
    • 2017
  • Disc harrow-type composite working implements of tractors are able to work almost 15km/hr. Soil reversing and plowing of agricultural fields are thereby faster than the existing rotavator speed of 2.5 km/h. In Korea, its supply process is being delayed because of the traditional tillage method of rotavator plowing operations. To develop products suitable for the domestic environment, an analysis and inspection was performed on the products of advanced specifications. 3D modeling was performed on main parts and frames using 3D scanner.

A Study on the Automatic Registration of Multiple Range Images Obtained by the 3D Scanner around the Object (물체 주위를 돌아가며 3차원 스캐너로 획득된 다면 이미지의 자동접합에 관한 연구)

  • 홍훈기;조경호
    • Korean Journal of Computational Design and Engineering
    • /
    • v.5 no.3
    • /
    • pp.285-292
    • /
    • 2000
  • A new method for the 3D automatic registration of the multiple range images has been developed for the 3D scanners(non-contact coordinates measurement systems). In the existing methods, the user usually has to input more than 3 pairs of corresponding points for the iterative registration process. The major difficulty of the existing systems lies in that the input corresponding points must be selected very carefully because the optimal searching process and the registration results mostly depend upon the accuracy of the selected points. In the proposed method, this kind of difficulty is greatly mitigated even though it needs only 2 pairs of the corresponding input points. Several registration examples on the 3D measured data have been presented and discussed with the introduction to the proposed algorithm.

  • PDF

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

Effect of abutment superimposition process of dental model scanner on final virtual model (치과용 모형 스캐너의 지대치 중첩 과정이 최종 가상 모형에 미치는 영향)

  • Yu, Beom-Young;Son, Keunbada;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.203-210
    • /
    • 2019
  • Purpose: The purpose of this study was to verify the effect of the abutment superimposition process on the final virtual model in the scanning process of single and 3-units bridge model using a dental model scanner. Materials and methods: A gypsum model for single and 3-unit bridges was manufactured for evaluating. And working casts with removable dies were made using Pindex system. A dental model scanner (3Shape E1 scanner) was used to obtain CAD reference model (CRM) and CAD test model (CTM). The CRM was scanned without removing after dividing the abutments in the working cast. Then, CTM was scanned with separated from the divided abutments and superimposed on the CRM (n=20). Finally, three-dimensional analysis software (Geomagic control X) was used to analyze the root mean square (RMS) and Mann-Whitney U test was used for statistical analysis (${\alpha}=.05$). Results: The RMS mean abutment for single full crown preparation was $10.93{\mu}m$ and the RMS average abutment for 3 unit bridge preparation was $6.9{\mu}m$. The RMS mean of the two groups showed statistically significant differences (P<.001). In addition, errors of positive and negative of two groups averaged $9.83{\mu}m$, $-6.79{\mu}m$ and 3-units bridge abutment $6.22{\mu}m$, $-3.3{\mu}m$, respectively. The mean values of the errors of positive and negative of two groups were all statistically significantly lower in 3-unit bridge abutments (P<.001). Conclusion: Although the number of abutments increased during the scan process of the working cast with removable dies, the error due to the superimposition of abutments did not increase. There was also a significantly higher error in single abutments, but within the range of clinically acceptable scan accuracy.

A 3D Foot Scanner Using Mirrors and Single Camera (거울 및 단일 카메라를 이용한 3차원 발 스캐너)

  • Chung, Seong-Youb;Park, Sang-Kun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.1
    • /
    • pp.11-20
    • /
    • 2011
  • A structured beam laser is often used to scan object and make 3D model. Multiple cameras are inevitable to see occluded areas, which is the main reason of the high price of the scanner. In this paper, a low cost 3D foot scanner is developed using one camera and two mirrors. The camera and two mirrors are located below and above the foot, respectively. Occluded area, which is the top of the foot, is reflected by the mirrors. Then the camera measures 3D point data of the bottom and top of the foot at the same time. Then, the whole foot model is reconstructed after symmetrical transformation of the data reflected by mirrors. The reliability of the scan data depends on the accuracy of the parameters between the camera and the laser. A calibration method is also proposed and verified by experiments. The results of the experiments show that the worst errors of the system are 2 mm along x, y, and z directions.

A Study on Airborne LiDAR System Calibration and Accuracy Evaluation (항공LiDAR 시스템 검정 및 정확도 평가 연구)

  • Choi, Yun-Soo;Kong, In-Ku;Lee, Kang-Won
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.23 no.4
    • /
    • pp.359-366
    • /
    • 2005
  • Airborne LiDAR integrated with on-board GPS/INS and scanning technology is a state-of the-art system for direct 3D geo-spatial data acquisition. In this study, LiDAR data were calibrated using ground points in calibration site for the higher system accuracy. The accuracy results are ${\pm}15{\sim}30\;cm$ in horizontal and ${\pm}15\;cm$ in vertical. The results show that LiDAR system has capability for precise DEM and contour generation, 3D urban modeling and engineering design.