• Title/Summary/Keyword: 3축 가속도 센서

Search Result 207, Processing Time 0.026 seconds

A Test Study on the Static/Dynamic Response of PC Structures According to the Connection Method and Damage Degree of PC Concrete Structures for Rapid Application of PC Concrete Construction Around Railway Stations (철도정거장 주변 PC 콘크리트 급속 시공 적용을 위한 PC 콘크리트 구조물 연결 방법 및 손상 정도에 따른 PC 구조물 정적/동적 응답에 대한 실험적 연구)

  • Park, Chang-Jin;Jeong, Han-Jung;Park, Yong-Gul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.53-60
    • /
    • 2020
  • In this study, smart precast-in-place concrete, such as continuity with Precast any technology that can be the Application of Building Structures and railway stations, civil structures. After the same way in the field installation design based on the criteria railways and derived the right section, through the Static and Dynamic Response Analysis. Dynamic sensor and the triaxial acceleration measured by attaching the sensor acceleration response according to the extent of the damage of Precast Panel Structures and mode of Precast Structures, by comparing the data. Data for the stability and improvement of the uncertainty in along a railroad and Future of Precast Panel Structures of time to replace. This is to use this data as basic data on damage prediction.

Design of a Compact GPS/MEMS IMU Integrated Navigation Receiver Module for High Dynamic Environment (고기동 환경에 적용 가능한 소형 GPS/MEMS IMU 통합항법 수신모듈 설계)

  • Jeong, Koo-yong;Park, Dae-young;Kim, Seong-min;Lee, Jong-hyuk
    • Journal of Advanced Navigation Technology
    • /
    • v.25 no.1
    • /
    • pp.68-77
    • /
    • 2021
  • In this paper, a GPS/MEMS IMU integrated navigation receiver module capable of operating in a high dynamic environment is designed and fabricated, and the results is confirmed. The designed module is composed of RF receiver unit, inertial measurement unit, signal processing unit, correlator, and navigation S/W. The RF receiver performs the functions of low noise amplification, frequency conversion, filtering, and automatic gain control. The inertial measurement unit collects measurement data from a MEMS class IMU applied with a 3-axis gyroscope, accelerometer, and geomagnetic sensor. In addition, it provides an interface to transmit to the navigation S/W. The signal processing unit and the correlator is implemented with FPGA logic to perform filtering and corrrelation value calculation. Navigation S/W is implemented using the internal CPU of the FPGA. The size of the manufactured module is 95.0×85.0×.12.5mm, the weight is 110g, and the navigation accuracy performance within the specification is confirmed in an environment of 1200m/s and acceleration of 10g.

Prediction of Energy Expenditure by Using a Tri-axial Accelerometer (단일 3축 가속도센서를 사용한 보행 시 대사에너지 예측)

  • Lee, Hee-Young;Kim, Seung-Hyeon;Lee, Dong-Yeop;Park, Sun-Woo;Kim, Young-Ho
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.2
    • /
    • pp.253-258
    • /
    • 2011
  • The purpose of this study was to compare metabolic energy expenditure with the computed kinetic energy for different speeds of walking and running over the treadmill and to find the relevance for individual and group equation by performing a statistical analysis, Bland-Altman plot. Seven male subjects participated, and they were required to walk and run on the treadmill with the gas analyzer and triaxial accelerometer. Walking speeds were 3.0, 4.0, 5.0 and 6.0 km/h and running speeds were 7.0, 8.0 and 9.0 km/h respectively. Kinetic energy was calculated by the integration of acceleration data and compared with the metabolic energy measured by a gas analyzer. Correlation coefficients showed relatively good between the measured metabolic energy and the calculated kinetic energy. In addition, a dramatic increase in kinetic energy was also observed at the transition speed of walking and running, and two standard deviations in Bland-Altman plot, derived from the difference between measured and predicted values, were 1.14, 2.53, 2.93, 1.80, 2.80, 0.60 and 2.48 respectively. It was showed that there is no difference for methods of how to predict the kinetic energy expenditure for individual and group even though people had each different physical characteristic.

Prediction of energy expenditure from a tri-axial accelerometer during treadmill walking (트레드밀 보행 시 단일 3축 가속도센서를 사용한 대사에너지 소모량 예측)

  • Lee, H.Y.;Park, S.W.;Kim, S.H.;Lee, D.Y.;Kim, Y.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.79-84
    • /
    • 2011
  • The purpose of this study was to investigate the relevance of the prediction equations derived from the relationship between metabolic energy expenditure and kinetic energy, for different speeds of walking and running over the treadmill. Seven male subjects participated in this study. A tri-axial accelerometer was attached on between the left and right posterior superior iliac spines. Kinetic energy was calculated by the integration of acceleration data and compared with the metabolic energy measured by a gas analyzer. Correlation coefficients were determined to find a relationship between the kinetic energy and the metabolic energy expenditure. Also, the difference between measured and predicted values was used to find the relevance for individual and group equations. Results showed a relatively good correlation between the measured metabolic energy and the calculated kinetic energy. In addition, a dramatic increase in kinetic energy was observed at the transition speed of walking and running (6 km/h). There was no difference in how to predict the kinetic energy expenditure for individual and group even though people have different physical characteristics. This study would be useful to predict metabolic energy expenditures by the regression analysis with acceleration data.

Implementation on SVM based Step Detection Analyzer (SVM 기반의 걸음 검출 분석기의 구현)

  • An, Kyung Ho;Kim, En Tae;Ryu, Uk Jae;Chang, Yun Seok
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.10
    • /
    • pp.1147-1155
    • /
    • 2013
  • In this study, we designed and implemented a step detection analyzer that can compare and analyze the step detection rates and results among the step detection algorithms. The step detection analyzer converts 3-axes accelerometer data into continuous energy stream through SVM operation, shows the horizontal comparison among the step detection results for each step detection algorithms, and can make elemental detection analyses. For these processes, the step detection analyzer presents the continuous energy stream as energy waveform, checks the peak values and time location of the detected steps with step detection algorithms, and gives visual interface to get some possible causes in cases of step detection miss. It can also give the threshold graph for each algorithm to check the threshold value on missed cases directly and can help to get more appropriate threshold values or other adjustable parameters in step detection algorithm. This step detection analyzer can be applied efficiently on performance enhancement of step detection algorithm, on deciding an appropriate algorithm for a specific step counter system in the various step counter filed operations.

A Fundamental Study on Vibration Characteristics of Container Car for Sensitive Cargo Transportation according to ASTM D-4169 (ASTM 규격에 따른 민감화물 수송용 컨테이너 화차의 진동 특성에 관한 기초 연구)

  • Ki, Ho-Cheol;Lee, Seung-Yil;Kim, Chul-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.53-59
    • /
    • 2019
  • To reduce the vibrations and shocks during the cargo transportation of high value-added goods, the vibration history was measured on the truck transportation section (Asan-Uiwang) and the freight train transportation section (Uiwang-Pusan). The internal vibrations of the container were obtained by attaching acceleration sensors in three axis directions (longitudinal, lateral. and vertical directions) on the front and rear bogies. The rail vibration profile (0.29Grms) proposed in ASTM D-4169 was approximately 50% higher than the truck vibration profile (0.54Grms). The overall vibration was 16% and 33 % lower in the longitudinal and transverse directions, respectively, compared to the ASTM truck transport vibration profile. On the other hand, the vertical vibration measurement history partially exceeded the ASTM truck transport vibration profile over the range, 4 - 15Hz, and over 60Hz. The vibration measurement history of the cargo train was similar to that of the road. The longitudinal and lateral vibration history was lower than the ASTM D-4169 rail vibration profile, while the vertical history was over 30Hz.

Development of the Balance Chair for Improving Postural Control Ability & Pelvic Correction (골반교정 및 자세균형능력 증진을 위한 균형의자 개발)

  • Oh, Seung-Yong;Shin, Sun-Hye;Kang, Seung-Rok;Hong, Chul-Un;Kwon, Tae-Kyu
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.3
    • /
    • pp.271-277
    • /
    • 2017
  • The purpose of this study was to develop a balance chair for improving pelvic correction and postural balance through postural balance training using tactile feedback by a vibration motor provided in real time according to the user's attitude. We built a body frame using mono cast(MC) Nylon, Touch thin film transistor(TFT) for user interface, a main control module using Arduino, a 9-axis acceleration sensor for user's posture determination, and a vibration module for tactile feedback. The prototype of the Balance Chair which surrounds the outside was made with cushion for sitting conformability. In order to verify the effectiveness of the postural balance training system using the built prototype, the muscle activity (% MVIC) of the left and right iliocostalis lumborum those are the main muscles of the spinal movement was measured with ten female subjects. And the balance ability before and after training was measured using Spine Balance 3D, a posture balance ability evaluation device. The muscular activities of the left and right iliocostalis lumborum showed the balance activation according to vibration feedback during exercise protocol and postural balance improved after balance exercise training using balance chair. This study could be apply to use the fundamental research for developing the various postural balance product.