• Title/Summary/Keyword: 3차원 초음파 검사

Search Result 31, Processing Time 0.023 seconds

Three Dimensional Ultrasonographic Evaluation with Intra-articular Saline Injection in Rotator Cuff Tear (회전근 개 파열의 수술 전 3차원 초음파 검사에서 관절내 생리식염수 주사 후 검사의 정확도)

  • Yum, Jae-Kwang;Shin, Yong-Woon;Park, Shin-Seung
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.62-67
    • /
    • 2009
  • Purpose: The purpose of this study is to find out the accuracy and usability of the three dimensional ultrasonography in measuring the size of the rotator cuff tear, especially before and after the injection of normal saline into the glenohumeral joint. Materials and Methods: 14 patients of rotator cuff tear who were diagnosed and operated from August 2007 to September 2008 were included in this study and authors compared the size of rotator cuff tear measured with three dimensional ultrasonography with the real size measured intraoperatively. In preoperative ultrasonographic evaluation, horizontal and longitudinal length of rotator cuff tear before and after injection of normal saline intraarticularly. During the arthroscopic operation the size of tear was measured by passing a Kirschner wire through a spinal needle and direct measure was performed in open surgery. Results: The average difference was 8 mm in horizontal and 1.9 mm in longitudinal length of tear without saline injection between ultrasonographic and intraoperative measure. The average difference was 4.1 mm in horizontal and 1.6 mm in longitudinal length of tear after the normal saline injection. Conclusion: In three dimensional ultrasonographic evaluation in rotator cuff tear, intraarticular normal saline injection would produce more accurate results.

  • PDF

3D visualization and navigation of the internal organs based on the 3D-Ultrasound Data (초음파 영상기반 파이프형 인체 장기의 3차원 가시화 및 네비게이션)

  • 최유주;홍헬렌;진수경;김명희
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2000.10b
    • /
    • pp.535-537
    • /
    • 2000
  • 인체 장기의 내부 벽면을 관찰하기 위하여 사용된 내시경 검사 기법은 내시경을 삽입하고, 질병 부위를 찾는 과정에서 환자에게 고통을 유발시키고, 정확한 진단을 내리기 위해서는 검사자의 오랜 경험과 숙달을 필요로 한다. 그러므로 각종 의료 영상을 기반으로 한 가상 내시경 시스템에 대한 연구와 개발이 요구된다. 본 논문에서는 초음파 영상을 기반으로 하여 병변 부위의 3차원 영상을 생성하고, 탐색하는 시스템을 제안한다. 우선 획득된 초음파 영상으로부터 장기에 대한 윤곽선 정보를 얻기 위하여, 초음파 영상에 대한 전처리 작업과 분할 작업을 수행하였고, 추출된 윤곽선 정보를 기반으로 3차원 표면 모델을 생성하였다. 3차원 표면 모델은 VRML 2.0 형식의 3차원 객체로 자동 변환되어 일반 VRML Plug-in viewer 및 자바 제어 모듈을 이용하여 3차원 장기 모델에 대한 탐색을 가능하도록 하였다.

  • PDF

Preoperative Three Dimensional Ultrasonographic Evaluation of the Rotator Cuff Tear (회전근 개 파열에 대한 수술 전 3차원 초음파 검사의 유용성)

  • Yum, Jae-Kwang;Sin, Yong-Woon;Han, Jung-Il
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.1
    • /
    • pp.24-28
    • /
    • 2008
  • Purpose: We wanted to determine if preoperative three dimensional (3D) ultrasonographic evaluation for rotator cuff tear is useful to measure the real size of a torn rotator cuff for performing an operation Materials and Methods: This study included 15 cases (7 males and 8 female), and these patients were confirmed to have a full thickness tear of the rotator cuff by 3D ultrasonography and the operative findings, as well as on the magnetic resonance imaging (MRI). The average age of the patients was 55.4yrs. Results: The average difference between the 3D ultrasonographic and operative measurements of the full thickness tear of the rotator cuff was 0.7 mm in the transverse length and 2.0 mm in the longitudinal length. Conclusion: The low error between the 3D ultrasonographic and intraoperative measurements of rotator cuff tear shows the usefulness of preoperative 3D ultrasonographic evaluation for rotator cuff tear.

Three-Dimensional Processing of Ultrasonic Pulse-Echo Signal (초음파 펄스에코 신호의 3차원 처리)

  • Song, Moon-Ho;Song, Sang-Rock;Cho, Jung-Ho;Sung, Je-Joong;Ahn, Hyung-Keun;Jang, Soon-Jae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.5
    • /
    • pp.464-474
    • /
    • 2003
  • Ultrasonic imaging of 3-D structures for nondestructive evaluation must provide readily recognizable images with enough details to clearly show various flaws that may or may not be present. Typical flaws that need to be detected are miniature cracks, for instance, in metal pipes having aged over years of operation in nuclear power plants; and these sub-millimeter cracks or flaws must be depicted in the final 3-D image for a meaningful evaluation. As a step towards improving conspicuity and thus detection of flaws, we propose a pulse-echo ultrasonic imaging technique to generate various 3-D views of the 3-D object under evaluation through strategic scanning and processing of the pulse-echo data. We employ a 2-D Wiener filter that filters the pulse-echo data along the plane orthogonal to the beam propagation so that ultrasonic beams can be sharpened. This three-dimensional processing and display coupled with 3-D manipulation capabilities by which users are able to pan and rotate the 3-D structure improve conspicuity of flaws. Providing such manipulation operations allow a clear depiction of the size and the location of various flaws in 3-D.

3 Dimensional Nondestructive Inspection of Cavities Inner Concrete by Ultrasonic Pulse Velocity Method (초음파속도법에 의한 콘크리트 내부공동의 3차원 비파괴검사)

  • Park, Seok-Kyun;Lee, Won-Hong;Heo, Jae-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.165-168
    • /
    • 2008
  • This study performed the 3-dimensional inspection analysis for cavitation by using the ultrasonic pulse velocity method to detect detailed various cavitations in a concrete test material. The internal-void are made of non-void test material and two types of which a regular square type and a rectangle type that produced through the 3-dimensional cavitation to put into a $500{\ast}500{\ast}500mm$ sized non-reinforced concrete test material. The tomography method for the ultrasonic pulse velocity method was used for the non-destructive test. As a result, this study has found that it is possible to visualize the cavitation as an image, and to analyze the internal-void in detail by the non-destructive method.

  • PDF

A Study on the Development of Ultrasonography Guide using Motion Tracking System (이미지 가이드 시스템 기반 초음파 검사 교육 기법 개발: 예비 연구)

  • Jung Young-Jin;Kim Eun-Hye;Choi Hye-Rin;Lee Chae-Jeong;Kim Seo-Hyeon;Choi Yu-Jin;Hong Dong-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1067-1073
    • /
    • 2023
  • Breast cancer is one of the top three most common cancers in modern women, and the incidence rate is increasing rapidly. Breast cancer has a high family history and a mortality rate of about 15%, making it a high-risk group. Therefore, breast cancer needs constant management after an early examination. Among the various equipment that can diagnose cancer, ultrasound has the advantage of low risk and being able to diagnose in real time. In addition, breast ultrasound will be more useful because Asian women's breasts are denser and less sensitive. However, the results of ultrasound examinations vary greatly depending on the technology of the examiner. To compensate for this, we intend to incorporate motion tracking technology. Motion tracking is a technology that specifies and analyzes a location according to the movement of an object in a three-dimensional space. Therefore, real-time control is possible, and complex and fast movements can be recorded in real time. We would like to present the production of an ultrasound examination guide using these advantages.

Characterization of Elastic Modulus of Kelvin Foam Using Elastic Structural Model and Ultrasound (초음파와 탄성 구조 모델을 이용한 캘빈 폼 재료의 탄성계수 평가)

  • Kim, Woochan Ethan;Kim, Nohyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.474-482
    • /
    • 2016
  • A Kelvin foam plate - widely used in the energy and transport industries as a lightweight structural material - was examined to estimate its Young's modulus using ultrasound. An isotropic tetrakaidecahedron foam structure was designed in SolidWorks and printed using 3D printer with an ABS plastic material. The 3D printed foam structure was used to build a foam plate with a 14 mm thickness ($50mm{\times}100mm$ in size) for the ultrasonic test. The Kelvin foam plate, a significantly porous medium, was completely filled with paraffin wax to enable the ultrasound to penetrate through the porous medium. The acoustic wave velocity of the wax-filled Kelvin foam was measured using the time of flight (TOF) method. Furthermore, the elastic modulus of the Kelvin foam was estimated based on an elastic structural model developed in this study. The Young's modulus of the produced Kelvin foam was observed to be approximately 3.4% of the bulk value of the constituent material (ABS plastic). This finding is consistent with experimental and theoretical results reported by previous studies.

Construction of Static 3D Ultrasonography Image by Radiation Beam Tracking Method from 1D Array Probe (1차원 배열 탐촉자의 방사빔추적기법을 이용한 정적 3차원 초음파진단영상 구성)

  • Kim, Yong Tae;Doh, Il;Ahn, Bongyoung;Kim, Kwang-Youn
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.2
    • /
    • pp.128-133
    • /
    • 2015
  • This paper describes the construction of a static 3D ultrasonography image by tracking the radiation beam position during the handy operation of a 1D array probe to enable point-of-care use. The theoretical model of the transformation from the translational and rotational information of the sensor mounted on the probe to the reference Cartesian coordinate system was given. The signal amplification and serial communication interface module was made using a commercially available sensor. A test phantom was also made using silicone putty in a donut shape. During the movement of the hand-held probe, B-mode movie and sensor signals were recorded. B-mode images were periodically selected from the movie, and the gray levels of the pixels for each image were converted to the gray levels of 3D voxels. 3D and 2D images of arbitrary cross-section of the B-mode type were also constructed from the voxel data, and agreed well with the shape of the test phantom.

Consideration of Sensors for Real-Time Quality Evaluation of Resisitance Spot Welds in Automotive Industry (자동차 저항 점 용접부 실시간 품질 검사 자동화를 위한 센서 검토)

  • Cho, Jung-Ho;Cho, Yong-Joon;Yoo, Sung-Pil;Chang, In-Sung;Do, Sung-Sup
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.50-50
    • /
    • 2010
  • 최근 토요타 자동차의 대량 리콜 사태로 안전과 관련된 자동차 품질에 대한 관심과 중요성이 크게 부각되었다. 본 연구에서는 나날이 높아지고 있는 자동차 품질 기준과 생산 비용 절감, 공정 자동화 요구에 부응하기 위한 차체 저항 점 용접부 품질 검사 자동화 기술 개발을 위해 적용 가능한 센서들을 비교, 검토하였다. 알려진 비파괴 검사 방법은 초음파, 와전류, 방사선 검사법 등 다양한 방법들이 존재하지만, 이 연구에서는 생산 라인 현장 적용이 가능한 소형 센서들을 중심으로 검토 영역을 제한하였다. 검토된 비파괴 검사 방법은 총 5가지 종류로 종래의 수동 초음파 검사법, 집적된 탐촉자를 이용한 3차원 초음파 검사법, NAUT(Non-contact Air-coupled Ultrasonic Test), EMAT(EletroMagnetic Acoustic Test), 그리고 너겟 프로파일러$^{TM}$이다. 이 연구에서는 각 검사법의 원리와 장단점을 설명하고 생산 라인 적용에 필요한 필수 항목들에 대해 고찰하였다.

  • PDF

New Performance Evaluation Method of Focused Ultrasonic Transducers By Using Virtual 3D Graphic (가상 3D 그래픽을 이용한 집속형 초음파 탐촉자 성능평가 방법)

  • Lee, Sun-Heum;Choi, Kwan-Sun;Kim, Dong-Sik
    • The KIPS Transactions:PartB
    • /
    • v.14B no.6
    • /
    • pp.407-412
    • /
    • 2007
  • The performance of ultrasonic testing systems for industrial or medical purpose largely depends on the performance of ultrasonic transducers. Generally, the information about an ultrasonic transducer performance characteristics are expressed by the ultrasonic R/F signal back from a reflector and its frequency characteristics in the data sheet provided by manufacturers. In case of focused ultrasonic transducers, the two pieces of information can, however, hardly assure that the focused ultrasonic transducer would produce well-focused C-scan images. Therefore, we propose the measured size of focal spot and the reconstructed shape of effective focal zone in the focused sound field as novel measures for the performance evaluation of the focused ultrasonic transducers. The process of getting the both measures of the transducers is conducted by the implemented software including sound field scanning and virtual 3D reconstruction functions which requires the echo of a point reflector. The proposed method could, otherwise impossible in the existing method, effectively and simply distinguish superior ones among many transducers made in the same specification and be also used to detect the performance degradation due to the aging of the transducers. Eventually, the quality of performance of the ultrasonic testing systems for industrial or medical purpose is secured.