• Title/Summary/Keyword: 3차원 영상분석

Search Result 1,110, Processing Time 0.029 seconds

The Motion Analysis of the Scaphoid, Capitate and Lunate During Dart-Throwing Motion Using 3D Images (3차원 영상을 이용한 다트 던지기 운동에서의 주상골, 유두골, 월상골의 움직임 분석)

  • Park, Chan-Soo;Kim, Kwang-Gi;Kim, Yu-Shin;Jeong, Chang-Bu;Jang, Ik-Gyu;Lee, Sang-Lim;Oh, Su-Chan;Yu, Do-Hyun;Baek, Goo-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.144-150
    • /
    • 2011
  • The primary purpose of this study was to analyze the motion of the scaphoid, capitate, and lunate during dart-throwing motion by three-dimensional modeling. Five series of CT images of five normal right wrists were acquired from five motion steps from radial extension to ulnar flexion in the dart-throwing motion plane. Segmentation and three-dimensional modeling of bones from CT images was performed using Analyze. Distances among centroids of the scaphoid, capitate and lunate and angles between principal axes of three carpal bones were calculated to analyze the motion by using MATLAB. As the wrist motion changed from radial extension to ulnar flexion, the distance between two adjacent bones decreased. The scaphoid and lunate rotated less than the capitates during dart-throwing motion. This study reports the Three-dimensional in vivo measurement of carpal motion using CT images.

Study of Platform for Real-Time Medical Information Protection and Management (실시간 의료정보 보호 및 관리를 위한 플랫폼에 관한 연구)

  • Jeong, Chang Won;Lee, Sung Gwon;Joo, Su Chong
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.3 no.8
    • /
    • pp.245-250
    • /
    • 2014
  • In recent years, the developments of medical technology and emergency medical services have been changed to home from the hospital. In this regard, the researches for the prevention or early diagnosis have become actively. In particular, bio-signal monitoring is applied to a variety of u-healthcare application services. The proposed system in this paper is to provide a security technology to protect the medical information measured from the various sensors. Especially, bio-signal information is privacy-sensitive personal information that must be protected. We applied a two-dimensional code technology, QR code, for the protection and management. In the client side, it can analyze the QR code and confirm the results on devices. Finally, with this proposed platform, we show the results of application service to verify the creation and distribution of integrated image file between the bio-signal and medical image information.

Applications of Focused Ion Beam for Biomedical Research (의생물 연구 분야에서 집속이온빔장치의 응용)

  • Kim, Ki-Woo;Baek, Saeng-Geul;Park, Byung-Joon;Kim, Hyun-Wook;Rhyu, Im-Joo
    • Applied Microscopy
    • /
    • v.40 no.4
    • /
    • pp.177-183
    • /
    • 2010
  • A focused ion beam (FIB) system produces a beam of positive ions (usually gallium) which are heavier than electrons and can be focused by electrostatic lenses into a spot on the specimen. With its ability milling of the specimen material by 10 to 100 nm with each pass of the beam, FIB is widely adopted in materials science, semiconductor industry, and ceramics research. Recently, FIB has been increasingly employed in the field of biomedical sciences. Here we provide a brief introduction to FIB and its applications for a wide variety of biomedical research. The surface of specimen can be in situ processed and quasi-real time visualized by two beam combination of FIB and field emission scanning electron microscope (FESEM). Due to its milling process, internal structures can be exposed and analyzed: yeast cells, fungus-inoculated wheat leaf, mannitol particles in inhalation aerosols, and oyster shell. Serial blockface tomography with the system kindles 3-dimensional reconstruction researches in the realm of nervous system and life sciences. Two-beam system of FIB/FESEM is a versatile tool to be utilized in the biomedical sciences, especially in 3-dimensional reconstruction studies.

Design Application for Urban Air Mobility(UAM) by STEEP Analysis (STEEP 분석을 통한 도심항공교통(UAM) 디자인 활용방안)

  • Lee, Dong Hun;Park, Hae Rim
    • Journal of Service Research and Studies
    • /
    • v.12 no.4
    • /
    • pp.94-105
    • /
    • 2022
  • Urban Air Transportation (UAM) is a three-dimensional transport within the city using eVTOL as an alternative to the saturation of land transportation due to overcrowding in major cities around the world. Design has played its roles in various fields in the development of transport, but research on the design application of UAM, which will be commercialized soon, is insufficient. Accordingly, there is a growing need for prior research on the forecasting the future environment and the design application through phenomenon analysis. The purpose of this study is to derive mega trends through STEP analysis for UAM and present ways to apply design in the UAM field based on this. The research method was conducted in the following order. First, the theoretical background of UAM was established by analyzing prior art documents on UAM. Second, five trends in the future environment centered on UAM were derived through STEP analysis. Finally, in order to derive a design application, five experts in each design area (product, visual, video, environment, service) discussed the design application focusing on the results of STEP analysis and derived a design application plan for each design area in the UAM field. Through this study, it was found that the most frequent design area in the STEEP analysis is product design and service design, and therefore related design development is important. After analyzing UAM's information provision plan, display method, and usage process suggested in this study, it is expected that it will lead to various prior design studies related to UAM, such as customized service design, to establish an infrastructure environment for commercialization of UAM.

Analysis of Eye-safe LIDAR Signal under Various Measurement Environments and Reflection Conditions (다양한 측정 환경 및 반사 조건에 대한 시각안전 LIDAR 신호 분석)

  • Han, Mun Hyun;Choi, Gyu Dong;Seo, Hong Seok;Mheen, Bong Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.5
    • /
    • pp.204-214
    • /
    • 2018
  • Since LIDAR is advantageous for accurate information acquisition and realization of a high-resolution 3D image based on characteristics that can be precisely measured, it is essential to autonomous navigation systems that require acquisition and judgment of accurate peripheral information without user intervention. Recently, as an autonomous navigation system applying LIDAR has been utilized in human living space, it is necessary to solve the eye-safety problem, and to make reliable judgment through accurate obstacle recognition in various environments. In this paper, we construct a single-shot LIDAR system (SSLs) using a 1550-nm eye-safe light source, and report the analysis method and results of LIDAR signals for various measurement environments, reflective materials, and material angles. We analyze the signals of materials with different reflectance in each measurement environment by using a 5% Al reflector and a building wall located at a distance of 25 m, under indoor, daytime, and nighttime conditions. In addition, signal analysis of the angle change of the material is carried out, considering actual obstacles at various angles. This signal analysis has the merit of possibly confirming the correlation between measurement environment, reflection conditions, and LIDAR signal, by using the SNR to determine the reliability of the received information, and the timing jitter, which is an index of the accuracy of the distance information.

The Study of Water Availability Increments by Estuary Lake in YoungSan River (영산강하구둑에 의한 수리권 가용수량 증가에 관한 고찰 고찰)

  • Park, Hee-Seong;Choi, Hyun-Gun;Kim, Chang-Shik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.2079-2083
    • /
    • 2007
  • 하구둑은 해수의 역류에 의한 염수침입을 방지하고 유역에 필요한 담수를 확보하기위하여 건설되며, 하구둑에 의하여 하천의 하구에 담수호가 생성된다. 하구담수호에 의해 기존에 염해로 취수할 수 없었던 하천구간에서의 취수가 가능하게 되며, 하구담수호를 일정한 수위로 관리함으로써 상당량의 농업용수를 확보할 수 있다. 이와 관련하여 하구담수호에 의하여 확보되는 수자원량에 대해 설계 당시의 분석 자료들이 있기는 하지만, 대부분 연 총량의 형태로 나타나 있으며, 수리권과 관련하여 하구둑에 의하여 추가적으로 확보되는 수리권 가용수량이 얼마인지에 대한 분석은 거의 없다. 그것은 하구둑의 방류량이 댐의 방류량과는 달라서 조석의 영향을 매우 크게 받기 때문에 단순한 물수지 분석으로 이를 모의하기 힘들기 때문이다. 게다가 1일 2회의 조석이 발생하므로 1일단위의 물수지 분석은 어려운 현실이다. 그럼에도 불구하고 하구둑에서 많은 양의 농업용수 취수가 이루어지고 있다. 과연 얼마정도의 양이 수리권으로서의 역할을 할 수 있는지 모르고 임의적인 허가가 계속 부여될 경우, 갈수 시 용수공급의 안정성을 확보할 수 없게 될 것이다. 따라서 안정적인 용수의 공급을 위한 적절한 수리권 가용수량에 대한 추정 필요하다. 이에 본 연구에서는 영산강하구둑의 실시간 운영을 위하여 고 등(2004)이 개발한 "영산강하구 둑 물관리 프로그램"의 기본적인 조위의 예측과 배수갑문의 방류량 산정기법 등과 수자원장기종 합계획(2006) 수립 시에 사용된 장기간의 일자연유량을 이용하여 하구둑의 수리권 가용수량 추정 모형을 개발하고, 이를 영산강 하구둑에 의해 생성된 영산호에 적용함으로써 영산호에 의해 증가되는 수리권 가용수량에 대해 고찰하여 보았다., 그리고 T-P $77.7{\sim}96.6%$(평균 94.3%)로 산정되었다. 이러한 결과는 대청호로 유입하는 유기물과 영양염류 연간 부하량의 80% 이상이 강우-유출과 함께 유입하는 것을 의미하며, 저수지 수질관리를 위해서는 유역차원의 비점오염원 관리가 시급함을 시사한다.하기 위해, 수렴흐름 추적자시험에 의한 종분산지수와 시험대수층의 평균선형유속을 이용하여 종분산계수를 구하였다. 현장에서 수행된 양수시험에 의한 평균선형유속 22.44 m/day와 평균 종분산지수 0.4155 m를 적용하여 산정된 종분산계수는 $9.32\;m^2/day$이었다. 따라서, 시험부지 내 충적층에서 일정한 양수율$(2,500\;m^3/day)$로 지하수를 개발할 시에 양수정 주변지역으로 유입되는 염소이온의 확산면적은 1일 $9.32\;m^2$ 정도일 것으로 나타났다.적인 $OH{\cdot}$ 의 생성은 ascorbate가 조직손상에 관여할 가능성을 시사하였다.었다. 정확한 예측치를 얻기 위하여 불균질 조직이 조사야에 포함되는 경우 보정이 요구되며, 골반의 경우 골 조직의 보정이 중요한 요인임을 알 수 있었다. 이를 위하여 불균질 조직에 대한 정확한 정보가 요구되며, 이는 CT 영상을 이용하는 것이 크게 도움이 되리라 생각된다.전시 슬러지층과 상등액의 온도차를 측정하여 대사열량의 발생량을 측정하고 슬러지의 활성을 측정할 수 있는 방법을 개발하였다.enin과 Rhaponticin의 작용(作用)에 의(依)한 것이며, 이는 한의학(韓醫學) 방제(方劑) 원리(原理)인 군신좌사(君臣佐使) 이론(理論)에서 군약(君藥)이 주증(主症)에 주(

  • PDF

Visual Interpretation about the Underground Information using Borehole Camera (휴대용 시추공 카메라를 이용한 지하정보의 가시화 기법)

  • Matsui Kikuo;Jeong Yun-Young
    • Tunnel and Underground Space
    • /
    • v.15 no.1 s.54
    • /
    • pp.28-38
    • /
    • 2005
  • According to the recent development of measurement system utilizing one or a set of boreholes, visualization of the explored underground became to be a major issue. It induced even the introduction of monitoring apparatuses on the borehole wall with multi-function tool, but the usage of these was often limited by where is unfavorable rock condition and a few of engineers can approach. And so, a portable type of borehole camera with only the essential function has been investigated and a few of commercial models about this is recently being applied into the field condition. This paper was based on the monitoring results obtained using a commercial model by Dr. Nakagawa. Discontinuities in rock mass were the topic for the visualization, and it was studied how can visualize their three dimensional distribution and what a numerical formulation is needed and how to understand the visualization result. The numerical formulation was based on the geometric correlation between the dip direction / dip of discontinuous plane and the trend / plunge of borehole, a set of the equation of a plane was induced. As field application of this into two places, it is found that the above visualization methodology will be especially an useful geotechlical tool for analyzing the local distribution of discontinuities.

A Comparative Study on Mashup Performance of Large Amounts of Spatial Data and Real-time Data using Various Map Platforms (다양한 맵 플랫폼을 이용한 대용량 동적정보와 공간정보의 매쉬업 성능 비교 연구)

  • Kang, Jin-Won;Kim, Min-Soo
    • Journal of Cadastre & Land InformatiX
    • /
    • v.47 no.2
    • /
    • pp.49-60
    • /
    • 2017
  • Recently, the use of mashup that integrates real-time data with spatial data such as tiled map and satellite imagery has been increased significantly. As the use of mashup has been extended to various fields of O2O, LBS, Smart City, and Autonomous Driving, the performance of mashup has become more important. Therefore, this study aims to compare and analyze the performance of various map platforms, when large amounts of real-time data are integrated with spatial data. Specifically, we compare the performance of most popular map platforms available in Korea, such as Google Maps, OpenStreetMap, Daum Map, Naver Map, olleh Map, and VWorld. We also compare the performance using most common web browsers of Chrome, Firefox and Internet Explorer. In the performance analysis, we measured and compared the initialization time of basic map and the mashup time of real-time data for the above map platforms. From analysis results, we could find that Google Maps, OpenStreetMap, VWorld, and olleh Map platforms showed a better performance than the others.

Usefulness of Abdominal Compressor Using Stereotactic Body Radiotherapy with Hepatocellular Carcinoma Patients (토모테라피를 이용한 간암환자의 정위적 방사선치료시 복부압박장치의 유용성 평가)

  • Woo, Joong-Yeol;Kim, Joo-Ho;Kim, Joon-Won;Baek, Jong-Geal;Park, Kwang-Soon;Lee, Jong-Min;Son, Dong-Min;Lee, Sang-Kyoo;Jeon, Byeong-Chul;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.157-165
    • /
    • 2012
  • Purpose: We evaluated usefulness of abdominal compressor for stereotactic body radiotherapy (SBRT) with unresectable hepatocellular carcinoma (HCC) patients and hepato-biliary cancer and metastatic liver cancer patients. Materials and Methods: From November 2011 to March 2012, we selected HCC patients who gained reduction of diaphragm movement >1 cm through abdominal compressor (diaphragm control, elekta, sweden) for HT (Hi-Art Tomotherapy, USA). We got planning computed tomography (CT) images and 4 dimensional (4D) images through 4D CT (somatom sensation, siemens, germany). The gross tumor volume (GTV) included a gross tumor and margins considering tumor movement. The planning target volume (PTV) included a 5 to 7 mm safety margin around GTV. We classified patients into two groups according to distance between tumor and organs at risk (OAR, stomach, duodenum, bowel). Patients with the distance more than 1 cm are classified as the 1st group and they received SBRT of 4 or 5 fractions. Patients with the distance less than 1 cm are classified as the 2nd group and they received tomotherapy of 20 fractions. Megavoltage computed tomography (MVCT) were performed 4 or 10 fractions. When we verify a MVCT fusion considering priority to liver than bone-technique. We sent MVCT images to Mim_vista (Mimsoftware, ver .5.4. USA) and we re-delineated stomach, duodenum and bowel to bowel_organ and delineated liver. First, we analyzed MVCT images to check the setup variation. Second we compared dose difference between tumor and OAR based on adaptive dose through adaptive planning station and Mim_vista. Results: Average setup variation from MVCT was $-0.66{\pm}1.53$ mm (left-right) $0.39{\pm}4.17$ mm (superior-inferior), $0.71{\pm}1.74$ mm (anterior-posterior), $-0.18{\pm}0.30$ degrees (roll). 1st group ($d{\geq}1$) and 2nd group (d<1) were similar to setup variation. 1st group ($d{\geq}1$) of $V_{diff3%}$ (volume of 3% difference of dose) of GTV through adaptive planing station was $0.78{\pm}0.05%$, PTV was $9.97{\pm}3.62%$, $V_{diff5%}$ was GTV 0.0%, PTV was $2.9{\pm}0.95%$, maximum dose difference rate of bowel_organ was $-6.85{\pm}1.11%$. 2nd Group (d<1) GTV of $V_{diff3%}$ was $1.62{\pm}0.55%$, PTV was $8.61{\pm}2.01%$, $V_{diff5%}$ of GTV was 0.0%, PTV was $5.33{\pm}2.32%$, maximum dose difference rate of bowel_organ was $28.33{\pm}24.41%$. Conclusion: Despite we saw diaphragm movement more than 5 mm with flouroscopy after use an abdominal compressor, average setup_variation from MVCT was less than 5 mm. Therefore, we could estimate the range of setup_error within a 5 mm. Target's dose difference rate of 1st group ($d{\geq}1$) and 2nd group (d<1) were similar, while 1st group ($d{\geq}1$) and 2nd group (d<1)'s bowel_organ's maximum dose difference rate's maximum difference was more than 35%, 1st group ($d{\geq}1$)'s bowel_organ's maximum dose difference rate was smaller than 2nd group (d<1). When applicating SBRT to HCC, abdominal compressor is useful to control diaphragm movement in selected patients with more than 1 cm bowel_organ distance.

  • PDF

The Benefit of Individualized Custom Bolus in the Postmastectomy Radiation Therapy : Numerical Analysis with 3-D Treatment Planning (유방전절제술 후 방사선치료를 위한 조직보상체 개발 및 3차원 치료계획을 통한 유용성 분석)

  • Cho Jae Ho;Cho Kwang Hwan;Keum Kichang;Han Yongyih;Kim Yong Bae;Chu Sung Sil;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.82-93
    • /
    • 2003
  • Purpose : To reduce the Irradiation dose to the lungs and heart in the case of chest wail irradiation using an oppositional electron beam, we used an Individualized custom bolus, which was precisely designed to compensate for the differences In chest wall thickness. The benefits were evaluated by comparing the normal tissue complication probablilties (NTCPS) and dose statistics both with and without boluses. Materials and Methods : Boluses were made, and their effects evaluated in ten patients treated using the reverse hockey-stick technique. The electron beam energy was determined so as to administer 80% of the irradiation prescription dose to the deepest lung-chest wall border, which was usually located at the internal mammary lymph node chain. An individualized custom bolus was prepared to compensate for a chest wall thinner than the prescription depth by meticulously measuring the chest wall thickness at 1 emf intervals on the planning CT Images. A second planning CT was obtained overlying the individuailzed custom bolus for each patient's chest wall. 3-D treatment planning was peformed using ADAC-Pinnacle$^{3}$ for all patients with and without bolus. NTCPS based on 'the Lyman-Kutcher' model were analyzed and the mean, maximum, minimum doses, V$_{50}$ and V$_{95}$ for 4he heari and lungs were computed. Results .The average NTCPS in the ipsliateral lung showed a statistically significant reduction (p<0.01), from 80.2${\pm}$3.43% to 47.7${\pm}$4.61%, with the use of the individualized custom boluses. The mean lung irradiation dose to the ipsilateral iung was also significantly reduced by about 430 cGy, Trom 2757 cGy to 2,327 cGy (p<0.01). The V$_{50}$ and V$_{95}$ in the ipsilateral lung markedly decreased from the averages of 54.5 and 17.4% to 45.3 and 11.0%, respectively. The V$_{50}$ and V$_{95}$ In the heart also decreased from the averages of 16.8 and 6.1% to 9.8% and 2.2%, respectively. The NTCP In the contralateral lung and the heart were 0%, even for the cases with no bolus because of the small effective mean radiation volume values of 4.4 and 7.1%, respectively Conclusion : The use of an Individualized custom bolus in the radiotherapy of postrnastectorny chest wall reduced the NTCP of the ipsilateral lung by about 24.5 to 40.5%, which can improve the complication free cure probability of breast cancer patients.