• Title/Summary/Keyword: 2nd phase

Search Result 592, Processing Time 0.026 seconds

A Research on the Actual Condition of the Prehospital Emergency Care and Education in 119 Emergency Medical Services (119구급대의 병원 전 응급처치 실태 및 교육 현황 분석)

  • Rho, Sang-Gyun;Lee, Jae-Gook;Kim, Jee-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2117-2124
    • /
    • 2012
  • This is the study of actual condition and improvement on emergency medical treatment by 119 emergency medical service personnel. The subjects in this study were 299 emergency medical service personnel. Data were collected from May 1 to August 31 of 2010, and analyzed by SPSS 12.0 program. The major area of study of them were study of emergency medical services 41.5%, study of nursing 10.0%, fire fighting related studies 15.4%, health related studies 1.0%, and others 32.1%. The certificate of them were 1st class emergency medical technician(EMT) 38.1%, 2nd class EMT 33.8%, nurse 9.4%, first aid education 14.0%, and others 4.7%. Frequency of Prehospital emergency care, oxygen supply(274), splint apply(229), spinal immobilization(229), external bleeding control(223), medication(7), intravenous(4). Professionally trained EMT makes possible to secure high quality emergency medical treatment in the prehospital phase. Therefore, it is essential for the quality improvement of prehospital emergency care that well trained EMT ride on the ambulance together and take the responsibility for the treatment and transferring of emergency patients. In order to improve the proficiency of 119 emergency medical services personnel, it is also necessary to provide continuous job training programs for the prehospital emergency medical treatment.

A Study on the Treatment Performance of Coalescer to Treat Exhaust Gas Cleaning Water (콜레이서를 이용한 배기가스 세정수 처리 성능에 관한 연구)

  • Ha, Shin-Young;Kim, In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.40 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • This study was conducted on a circulation system which can recycle waste water from EGCS(Exhaust Gas Cleaning System) using a wet scrubber that is used to treat air pollutants from ships. Though we developed a water treatment system that could remove effectively particulate matters and dispersed oil included in cleaning water for Ship Exhaust Gas Recycle System(DePM & DeSOx), we found that it is difficult to treat minutely dispersed oil only by means of centrifugal-typed purifier. Therefore, to this system, we applied a coalescer that coalesces emulsified minute oil particles in the 2nd phase of dispersion state after being filtered through the centrifugal-typed purifier. After we treated cleaning water drained out of Ship Exhaust Gas Recycle System(DePM & DeSOx) by using both purifier and coalescer, we found that particulate matters and dispersed oil were removed more than 55% and 99%, respectively, in comparison with those contained in cleaning water influent. Putting the results together, we conclude that the treated cleaning water can be recycled as normal cleaning water if this cleaning water treatment system is employed by the wet cleaning tower system for the reduction of air pollutants from ships.

Study on Methodology for Effect Evaluation of Information Offering to Rail passengers - Focusing on the Gate Metering Case Study considering congested conditions at a platform - (철도 이용객 정보제공 효과평가 방법론 연구 - 승강장의 혼잡상황을 고려한 Gate Metering 사례 연구 중심으로 -)

  • Lee, Seon-Ha;Cheon, Choon-Keun;Jung, Byung-Doo;Yu, Byung-Young;Kim, Eun-Ji
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.14 no.3
    • /
    • pp.50-62
    • /
    • 2015
  • Recently, Subway Line No. 9, described as a 'hell-like' subway for its recorded load factor of max. 240% due to the opening of the 2nd phase extension section, has been causing problems of recurrent congestion in a subway station building. A recurrent congestion in the station building becomes a factor to offend rail users and to reduce the efficiency of railway management. This study aims to establish the methodology for effect evaluation of information provided to rail users, and conducts a gate metering case study considering the congested conditions at a platform among the methodologies for effect evaluation. The metering effect evaluation by load factor was conducted through selecting the micro simulation and pedestrian simulation tool grafting a gate metering. As a result, it was confirmed that, if gate metering is performed, the service level and pedestrian density of a platform by load factor would improve. In other words, if metering is conducted at a platform, it is possible to control the load factor in the waiting space of a platform. Therefore, it was judged through this study that it is possible to set up the index for effect evaluation of information provided to manage congestion of rail users, and establish the methodology for effect evaluation of information provided to rail users through a program.

A three-dimensional kinematic analysis of the field goal kicking motion in American football (미식축구의 필드골(Field Goal) 킥(Kick)에 대한 운동학적 분석)

  • Ahn, Chan-Gyu;Kim, Ky-Hyung;Choi, Seung-Bang
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.1
    • /
    • pp.139-153
    • /
    • 2003
  • The purpose of the study was to present technical guidance about the field goal kicking motion in American football for novices. For this purpose, kinematic analysis on the field goal kicking motion of two skilled players and two unskilled players was carried out. The following conclusions were made: 1. In comparison on the total elapsed time of the kicking, there were no significant differences between two groups. The progressing time from BP event to impact among experts group, however, took 0.141 second less than that of novices group. 2. The experts group showed right hip rotatier horizontally toward the targeted ball fixing left hip as the axis. On the other hand, the novices group didn't use the left hip as the axis in the kicking motion. 3. At the impact of kicking the ball, regarding with the distance of the ball and the supporting leg, the right and left distance of experts was 3.45cm longer than that of novices, the front and the rear distance of experts was 5.14cm shorter than novices. 4. At the impact, experts' initial velocity of the targeted ball was $5.27^m/s$ faster than novices', besides experts' incidence angular displacement was $3.78^{\circ}$ larger than novices'. 5. After BP event, experts showed a stable movement maintaining flexion and extension at left hip joint and knee joint. On the other hand, for novices, the angle of the left lower extremities became larger. 6. Experts showed the efficient flexion and extension of the hip joint and the knee joint during following procedure in the whole event of the kicking motion. At the BP event, the right knee joint angle of novices was $11.46^{\circ}$ larger than that of experts. However, the duration of the impact event and FT event among, novices had less extension of knee joint than experts. 7. At the 2nd phase, for both of the groups, the angular velocity of the knee joint drastically increased as the angular velocity of hip joint decreased. However, only novices showed the largest negative angular velocity at the impact.

The Improvement of maintainability evaluation method at system level using system component information and fuzzy technique (시스템의 구성품 정보와 퍼지 기법을 활용한 시스템 수준 정비도 평가 방법의 개선)

  • Yoo, Yeon-Yong;Lee, Jae-Chon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.100-109
    • /
    • 2019
  • Maintainability indicates the extent to which maintenance can be done easily and quickly. The consideration of maintainability is crucial to reduce the operation and support costs of weapon systems, but if the maintainability is evaluated after the prototype production is done and necessitates design changes, it may increase the cost and delay the schedule. The evaluation should verify whether maintenance work can be performed, and support the designers in developing a design to improve maintainability. In previous studies, the maintainability index was calculated using the graph theory at the early design phase, but evaluation accuracy appeared to be limited. Analyzing the methods of evaluating the maintainability using fuzzy logic and 3D modeling indicate that the design of a system with good maintainability should be done in an integrated manner during the whole system life cycle. This paper proposes a method to evaluate maintainability using SysML-based modeling and simulation technique and fuzzy logic. The physical design structure with maintainability attributes was modeled using SysML 'bdd' diagram, and the maintainability was represented by an AHP matrix for maintainability attributes. We then calculated the maintainability using AHP-based weighting calculation and fuzzy logic through the use of SysML 'par' diagram that incorporated MATLAB. The proposed maintainability model can be managed efficiently and consistently, and the state of system design and maintainability can be analyzed quantitatively, thereby improving design by early identifying the items with low maintainability.

Alternative Immunossays

  • Barnard, G.J.R.;Kim, J.B.;Collins, W.P.
    • Korean Journal of Animal Reproduction
    • /
    • v.9 no.2
    • /
    • pp.133-139
    • /
    • 1985
  • An immunoassay may be defined as an analytical procedure involving the competitive reaction between a limiting concentration of specific antibody and two populations of antigen, one of which is labelled or immobillized. The advent of immunoassay has revolutionised our knowledge of reproductive physiology and the practice of veterinary and clinical medicine. Radioimmunoassay (RIA) was the first of these methods to be developed, which meausred the analyte with good sensitivity, accuracy and precision (1,2). The essential components of RIA are:-(i) a limited concentration of antibodies, (ii) a reference preparation, and (iii) an antigen labelled with a radioisotope (usually tritium or iodine-125). Most procedures invelove isolating the antibody-bound fraction and measuring the amount of labelled antigen. Good facilities are available for scintilltion counting, data reduction nd statistical analysis. RIA is undergoing refinement through:-(i) the introduction of new techniques to separate the antibody-bound and free fractions which minimize the misclassification of labelled antigen into these compartments, and the amount of non-specfic binding. (3), (ii) the development of non-extration for the measurement of haptens (4), (iii) the determination of a, pp.rent free (i.e. non-protein bound) analytes (5), and (iv) the use of monoclonal antibodies(6). In 1968, Miles and Hales introduced in important new type of immunoassay which they termed immunora-diometric assay (IRMA) based on t도 use of isotopically labelled specific antibodies(7) in a move from limited to excess reagent systems. The concept of two-site IRMAs (with a capture antibody on a solid-phase, and a second labelled antibody to a different antigenic determinant of the analyte) has enabled the development of more sensitive and less-time consuming methods for the measurement of protein hormones ovar wide concentration of analyte (8). The increasing use of isotopic methos for diverse a, pp.ications has exposed several problems. For example, the radioactive half-life and radiolysis of the labelled reagent limits assay sensitivity and imposes a time limit on the usefulness of a kit. In addition, the potential health hazards associated with the use and disposal of radioactive cmpounds and the solvents and photofluors necessary for liquid scientillation counting are incompatable with the development of extra-laboratory tests. To date, the most practical alternative labels to radioisotopes, for the measurement of analytes in a concentration > 1 ng/ml, are erythrocytes, polystyrene particiles, gold sols, dyes and enzymes or cofactors with a visual or colorimetric end-point(9). Increased sensitivity to<1 pg/ml may be obtained with fluorescent and chemiluminescent labels, or enzymes with a fluorometric, chemiluminometric or bioluminometric end-point. The sensitivity of any immunoassay or immunometric assay depends on the affinity of the antibody-antigen reaction, the specific activity of the label, the precision with which the reagents are manipulated and the nonspecific background signal (10). The sensitivity of a limited reagent system for the measurement of haptens or proteins is mainly dependent upon the affinity of the antibodies and the smalleest amount of reagent that may be manipulated. Consequently, it is difficult in practice to improve on the sensitivity obtained with iodine-125 as the label. Conversely, with excess reagent systems for the measurement of proteins it is theoretically possible to increase assay sensitivity at least 1000 fold with alternative luminescent labels. To date, a 10-fold improvement has been achieved, and attempts are being made to reduce the influence of other variables on the specific signal from the immunoreaction.

  • PDF

Change of hemostatic markers according to the clinical state in Kawasaki disease (가와사끼병의 임상경과에 따른 지혈성 표지의 변화와 임상적 의의)

  • Kim, Yong Beom;Yoon, You Sook;Lee, Sang Yun;Kil, Hong Ryang
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.12
    • /
    • pp.1247-1251
    • /
    • 2007
  • Purpose : Pathologically, Kawasaki disease (KD) is associated with widespread vascular endothelial damage in the acute phase. The vasculitis induced endothelial injury leads to coagulation abnormalities. Abnormalities of endothelial function, platelet activation, and fibrinolysis are present during acute phase and long after the onset of KD. The aim of study is to evaluate the change of hemostatic markers in the clinical stages of KD and to assess the hemostatic markers to be a useful indicator of the development of coronary artery lesion (CAL). Methods : Seventy four KD patients diagnosed in Chungnam National University Hospital from November 2004 to June 2007. Eleven febrile control and eleven healthy children were selected for healthy control. All blood samples were collected before and after Intravenous gammaglobulin (IVGG), $2^{nd}$ week, and $4^{th}-8^{th}$ week of illness of KD. Results : Initial D-dimer level of Kawasaki disease showed meaningful difference compared to control group (P<0.05). D-dimer and fibrinogen degradation products (FDP) before IVGG increased compared with normal control group and decreased after IVGG administration. It is normalized until 2 weeks later, and continue to decreasing. D-dimer and FDP were significantly different according to the CAL before IVGG. Conclusion : The hemostatic markers may change to the clinical stage of KD, which may suggest the degree of endothelial injury. Increased some hemostatic markers may be the predictors for development of CAL.

The Effect of Marketing Characteristic on Business Performance (창업마케팅특성이 기업성과에 미치는 영향)

  • Jeon, In-oh;An, Un-Seok
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.11 no.3
    • /
    • pp.97-109
    • /
    • 2016
  • In Korea, the survival rate of start-up of 5-year after foundation is as low as 29.6% of the country. This low survival rate is from because of insufficient resources in start-ups compared to those of mid-sized companies. Therefore, the marketing characteristics of entrepreneurship has emerged as a major cause. Therefore, In this study, because learning orientation, marketing experience, competition orientation and etc are differently owned in start-ups, marketing impact to marketing strategy in start-up companies are differently investigated. Therefore, the relationship of learning orientation, marketing experience, competition Orientation with marketing strategies was examined. Based on this, Business performance was examined to suggest contents related to eco-system of start-up companies to representative of start-up companies. For this study, Survey was conducted for 250 start-up entrepreneurs within 3 and half year since foundation from Nov. 20 to Dec. 20, 2015. In result of data-cleaning, 207 meaningful samples were gathered. Based on these, conclusion was obtained. Using SPSS 20.0 statistical program, frequency analysis, reliability analysis, correlation analysis and regression analysis were conducted. the following conclusions were drawn. First, in the impact of marketing environment of Phase 1 start-up companies on marketing strategy, product strategy, distribution strategy and promotion strategy were positively affected by learning orientation, marketing experience and competition orientation. Second, in the effect of 2nd phase marketing strategy to business performance, the financial performance and the non-financial performance. Were positively affected by product strategy, distribution strategy and promotion strategies. Third, The effect of learning orientation, marketing experience and competition orientation to financial performance was positively mediated by product strategy and distribution strategy among 3rd phase meditation strategies. the effect of learning orientation, marketing experience and competition orientation to non-financial performance was positively mediated by products strategy. In comprehensive summary, in order to increase business performance in start-up companies, marketing strategy should be applied in. Especially, the role of learning orientation and marketing experience is vital. In increasement of business performance to characteristics of star up marketing, financial performance can be increased by product strategy and distribution strategy. And, both of financial and non-financial performance can be increased by product strategy. Therefore, in conducting of marketing characteristics of start-up, to increase business performance, the apply of marketing strategy to marketing characteristics of start-up should be required.

  • PDF

Study on the Application for Hydrogen Storage Tank of MmNi4.5Mn0.5Zrx(x=0, 0.025, 0.05, 0.1) Alloys Containing Excess Zr (과잉 Zr을 첨가한 MmNi4.5Mn0.5Zrx(x=0, 0.025, 0.05, 0.1) 합금의 수소용기 적용에 관한 연구)

  • Kang, Kil-Ku;Park, Sung-Gap;Kang, Sei-Sun;Kwon, Ho-Young
    • Korean Journal of Materials Research
    • /
    • v.12 no.8
    • /
    • pp.624-633
    • /
    • 2002
  • In order to improve the hydrogen storage capacity and the activation properties of the hydrogen storage alloys, the rare-earth metal alloy series, MmN $i_{4.5}$M $n_{0.5}$Z $r_{x}$(x=0, 0.025, 0.05, 0.1), are prepared by adding excess Zr in MmN $i_{4.5}$M $n_{0.5}$ alloy. The various parts in hydrogen storage vessel consisted of copper pipes reached the setting temperature within 4~5 minutes after heat addition, which indicated that storage vessel had a good heat conductivity required in application. The performance test on storage vessel filled with rare-earth metal alloys of 1000 gr was also conducted after hydrogen charging for 10 min at $18^{\circ}C$ under 10 atm. It showed that the average capacity of discharged hydrogen volume was found to be for $MmNi_{4.5}$ $Mn_{0.5}$ and $MmNi_{4.5}$ $Mn_{x}$ 0.5/$Zr_{samples}$ indicated that the released amount of hydrogen for this $AB_{5}$ type alloys was more than 92 % of theoretic value, and also it was found that the optimum discharging temperature for obtaining an appropriate pressure of 3 atm was determined to be $V^{\circ}C$ for $MmNi_{4.5}$ $Mn_{0.5}$$Zr_{x}$(x=0, 0.025, 0.05, 0.1) hydrogen storage alloys. The released amount of these hydrogen storage samples was 125 $\ell$ , 122.4 $\ell$ and 108.15 $\ell$/kg for $MmNi_{4.5}$ $Mn_{0.5}$ $Zr_{0.025}$ $MmNi_{4.5}$M $n_{0.5}$Z $r_{0.05}$, and MmN $i_{4.5}$ Mn_0.5$Zr_{0}$, at $70^{\circ}C$ respectively. Amount of the 2nd phases increase with increase on Zr contents in $MmNi_{4.5}$$Mn_{0.5}$ $Zr_{ 0.1}$/ alloy. This phenomenon indicates that$ ZrNi_3$ in $MmNi_{4.5}$ $Mn_{0.5}$ $Zr_{x}$ / phase, which shows the maximum storage capacity and the strong resistance to intrinsic degradation, is considered as a proper alloy for hydrogen storage. As the Zr contents increase, the activation time and the plateau pressure decreases and sloping of the plateau pressure increases.creases.eases.s.

Results of Total Body Irradiation in Allogeneic Bone Marrow Transplantation for Acute Non-Lymphocytic Leukemia (급성 골수성 백혈병에서 동종골수이식을 위한 전신 방사선 조사의 치료 결과)

  • Chung Su Mi;Choi Ihl Bohng;Kim In Ah;Kim Sung Hwan;Kang Ki Mun;Shinn Kyung Sub;Kim Choon Choo;Kim Dong Jip
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.247-253
    • /
    • 1992
  • Between August 1987 and July 1991, 22 patients with acute nonlymphocytic leukemia have received allogeneic bone marrow transplantation (BMT) with non-T-lymphocyte-depleted marrow obtained from matched sibling donors. Of these patients, 12 patients were in first complete remission (CR) and 10 patients in second CR or greater or in relapse. All patients were treated with a preparative regimen consisting of cyclophosphamide (CTX, 60 mg/kg) or combined drugs, and 850 cGy single-dose or $150\~200$ cGy fractionated total body irradiation (TBI) administered twice daily for a total dose of $1200\~1320$ cGy. Survivors have been followed from 8 to 64.5 months (median, 24 months). The overall 2 year survival rate, relapse rate and incidence of radiation pneumonitis and graft versus host disease (GVHD) have been evaluated by age, phase of disease, initial WBC count, modality of TBI or conditioning chemotherapy. Overall 2 year survival was $58{\%}$. The median survival was 31 months and mean survival was 23.2 months. Overall survival have significant impact in patients of age >19 years old (p=0.008), patients in first CR (p=0.09). Two year survival rate is significantly correlated with age ( >19 vs $\leqq$19, $79.4\%$ vs $14.3\%$, p=0.0008), regimen of chemotherapy (CTX vs combined drug, $76.9\%\;vs\;33.3\%$, p=0.04), phase of disease (1st CR vs \geqq2nd$ CR or relapse, $83.3\%\;vs\;30\%$, p=0.01) and method of TBI (fractionated vs single dose, $70.7\%\;vs\;37.5\%$, p=0.05). The influence of French-American-British (FAB) subtypes on relapse rate is not significant, but initial WBC count > 20000/$mm^3$ is associated with increased relapse rate. There is difference in the rate of radiation pneumonitis ($14.3\%\;vs\;25\%$), GVHD ($14.3\%\;vs\;50\%$) and relapse ($21.4\%\;vs\;50\%$) according to fractionated versus single-dose TBI. As mentioned above, fractionated TBI is compatible for the preparative regimen combined with chemotherapy En allogeneic BMT of first CR patients under 41 years of age with suitable donor. Those results from a retrospective, non-randomized study clearly need additional clinical data, ideally from a randomized study.

  • PDF