• Title/Summary/Keyword: 2nd generation

Search Result 346, Processing Time 0.029 seconds

Analysis of Beam Quality of the Unsymmetric Nd : YAG Laser with Unstable Resonator (비대칭 구조로 이루어진 불안정 공진기형 Nd : YAG 레이저의 빔질 분석)

  • Kim, Hyun-Su
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.5
    • /
    • pp.456-461
    • /
    • 2005
  • We numerically investigate the characteristic of single Nd:YAG rod laser with the convex-plane resonator configuration in order to get the best condition for high efficient intra-cavity second harmonic generation(SHG). The beam quality is analyzed with ABCD matrixes including the thermal lensing characteristic of Nd:YAG rod. The analysis is focused on stability, M2, beam waist and mode-volume of laser beam inside the resonator. The best conditions for SHG is obtained when a laser rod is set near the curved laser mirror.

HTS Nested magnet wound with 12 mm GdBCO tape and 4.4 mm YBCO tape

  • Kang, Myunghun;Ku, Myunghwan;Cha, Gueesoo;Lim, Hyoungwoo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.2
    • /
    • pp.50-53
    • /
    • 2015
  • The properties of High Temperature Superconducting (HTS) tapes are progressing, as HTS tapes evolve from 1st generation to 2nd generation. This paper presents design and construction of a 2nd generation HTS magnet consisting of two nested GdBCO and YBCO pancake coils. Two HTS tapes of different widths were used to wind the HTS nested magnet. Considering that a higher magnetic field is applied to the inner magnet than to the outer magnet, 12 mm GdBCO tape was used for winding the inner magnet, which consisted of four single pancake windings. Eight double pancake windings wound with 4.4 mm YBCO tapes were used for the outer magnet. The test results show that the central magnetic field of the HTS nested magnet was 920 mT. The measured critical currents of the inner and outer magnet at 77K were 80.8 A and 32.6 A, respectively.

Analysis of Harmonic Wave Generation in Nonlinear Oblique Crack Surface (비선형 경사 균열면에서의 고조파 발생 특성 해석)

  • Kim, Noh-Yu;Yang, Seung-Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.376-387
    • /
    • 2012
  • Based on the nonlinear spring model coupled with perturbation method, 2nd harmonic waves generated by oblique incident ultrasound on nonlinear crack interface were calculated and investigated. Reflected and transmitted waves from the interface were determined and analyzed at various angle of incidence for the cracks with different interfacial stiffness in order to estimate the 2nd harmonic generation of incident ultrasound. It was shown in computer simulation that the 2nd harmonic components changed much with the increase of incidence angle in both reflected and transmitted wave, but became very small when the incident angle approached toward 90 degree. It can be concluded that the 2nd harmonic component of reflected wave has a meaningful amplitude as much as the transmitted 2nd harmonic wave from partly closed crack.

Study on the Generation of Chemically Active Species Using Gas-liquid Mixing Plasma Discharging System (기-액 혼합 플라즈마 방전 시스템에서 화학적 활성종의 생성)

  • Kim, DongSeog;Park, YoungSeek
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.4
    • /
    • pp.394-402
    • /
    • 2014
  • High-voltage dielectric discharges are an emerging technique in environmental pollutant degradation, which are characterized by the production of hydroxyl radicals as the primary degradation species. The initiation and propagation of the electrical discharges depends on several physical, chemical, and electrical parameters such as 1st and 2nd voltage of power, gas supply, conductivity and pH. These parameters also influence the physical and chemical characteristics of the discharges, including the production of reactive species such as OH, $H_2O_2$ and $O_3$. The experimental results showed that the optimum 1st voltage and oxygen flow rate for RNO (N-Dimethyl-4-nitrosoaniline, indicator of the generation of OH radical) degradation were 160 V (2nd voltage of is 15 kV) and 4 L/min, respectively. As the 2nd voltage (4 kV to 15 kV) was increase, RNO degradation was increased and, generated $H_2O_2$ and $O_3$ concentration were increased. The conductivity of the solution was not influencing the RNO degradation, $H_2O_2$ and $O_3$ generation. The pH effect on RNO degradation was not high. However, the lower pH and the conductivity, the higher $H_2O_2$ and $O_3$ generation were observed.

Myocardial Coverage and Radiation Dose in Dynamic Myocardial Perfusion Imaging Using Third-Generation Dual-Source CT

  • Masafumi Takafuji;Kakuya Kitagawa;Masaki Ishida;Yoshitaka Goto;Satoshi Nakamura;Naoki Nagasawa;Hajime Sakuma
    • Korean Journal of Radiology
    • /
    • v.21 no.1
    • /
    • pp.58-67
    • /
    • 2020
  • Objective: Third-generation dual-source computed tomography (3rd-DSCT) allows dynamic myocardial CT perfusion imaging (dynamic CTP) with a 10.5-cm z-axis coverage. Although the increased radiation exposure associated with the 50% wider scan range compared to second-generation DSCT (2nd-DSCT) may be suppressed by using a tube voltage of 70 kV, it remains unclear whether image quality and the ability to quantify myocardial blood flow (MBF) can be maintained under these conditions. This study aimed to compare the image quality, estimated MBF, and radiation dose of dynamic CTP between 2ndDSCT and 3rd-DSCT and to evaluate whether a 10.5-cm coverage is suitable for dynamic CTP. Materials and Methods: We retrospectively analyzed 107 patients who underwent dynamic CTP using 2nd-DSCT at 80 kV (n = 54) or 3rd-DSCT at 70 kV (n = 53). Image quality, estimated MBF, radiation dose, and coverage of left ventricular (LV) myocardium were compared. Results: No significant differences were observed between 3rd-DSCT and 2nd-DSCT in contrast-to-noise ratio (37.4 ± 11.4 vs. 35.5 ± 11.2, p = 0.396). Effective radiation dose was lower with 3rd-DSCT (3.97 ± 0.92 mSv with a conversion factor of 0.017 mSv/mGy∙cm) compared to 2nd-DSCT (5.49 ± 1.36 mSv, p < 0.001). Incomplete coverage was more frequent with 2nd-DSCT than with 3rd-DSCT (1.9% [1/53] vs. 56% [30/54], p < 0.001). In propensity score-matched cohorts, MBF was comparable between 3rd-DSCT and 2nd-DSCT in non-ischemic (146.2 ± 26.5 vs. 157.5 ± 34.9 mL/min/100 g, p = 0.137) as well as ischemic myocardium (92.7 ± 21.1 vs. 90.9 ± 29.7 mL/min/100 g, p = 0.876). Conclusion: The radiation increase inherent to the widened z-axis coverage in 3rd-DSCT can be balanced by using a tube voltage of 70 kV without compromising image quality or MBF quantification. In dynamic CTP, a z-axis coverage of 10.5 cm is sufficient to achieve complete coverage of the LV myocardium in most patients.

Second Harmonic Generation on the Surface of Porous Silicon Superlattice (초격자 다공질규소 표면에서 제 2고조파 발생)

  • Cho, Chang-Ho;Park, Jong-Dae
    • The Journal of Natural Sciences
    • /
    • v.12 no.1
    • /
    • pp.31-39
    • /
    • 2002
  • Second harmonic generation was measured in porous silicon superlattices surface which were made by changing and anodization current density and the anodization time periodically in the process of obtaining porous silicon. The technique of second harmonic generation is used as a probe to the surface of porous silicon superlattice by using Nd:YAG laser. We have investigated the surface structure and nonlinear-optics properties of porous silicon superlattice.

  • PDF

Cure Behavior and Tensile Properties of Ethylidene Norbornene/endo-Dicyclopentadiene Blends (Ethylidene Norbornene/endo-Dicyclopentadiene 블렌드의 경화 거동 및 인장 특성)

  • Jung, Jong Ki;Choi, Jung Hwa;Yang, Guang;Park, Jongmoon;Kim, Donghak;Kim, Seonggil;Lee, Jong Keun;Oh, Myung-Hoon;Kim, Bongsuk;Bang, Daesuk
    • Polymer(Korea)
    • /
    • v.39 no.3
    • /
    • pp.506-513
    • /
    • 2015
  • Ethylidene norbornene (ENB) and its blends with endo-dicyclopentadiene (endo-DCPD) were prepared and reacted via the ring-opening metathesis polymerization (ROMP) reaction with the $1^{st}$ and $2^{nd}$ generation Grubbs' catalysts. Dynamic exothermic behaviors during ROMP and tensile properties after ROMP were evaluated using a differential scanning calorimeter (DSC) and a universal testing machine (UTM) for the samples, respectively. It revealed that the ROMP rate was accelerated with the less contents of endo-DCPD and under the $2^{nd}$ generation catalyst. Also, the addition of endo-DCPD and the $1^{st}$ generation catalyst resulted in higher tensile modulus and strength but lower toughness. Gel fraction measurement and fracture surface observation were made to understand the tensile properties.

Growth of the Box Tree Pyralid, Glyphodes perspectalis Reared on an Artificial Diet Through Four Generations (인공사료로 키운 회양목명나방의 세대별 발육 특성)

  • Park, Il-Kwon
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.2
    • /
    • pp.305-308
    • /
    • 2012
  • The box tree pyralid, Glyphodes perspectalis, was reared on an artificial diet based on dried powder of box tree leaves, Buxus microphylla var. koreana, and INSECTA F-II (Nihon Nosan Co., Ltd) at a ratio of 3:7 (w:w) and analyzed in their developmental characteristics from $1^{st}$ to $4^{th}$ generation. The developmental period of larva reared on artificial diet was longer than that of larva reared on host plant. Significant difference in larval period was also observed between $1^{st}$ and other generation groups. Pupation rate was the highest in $4^{th}$ generation followed by $3^{rd}$, $2^{nd}$, $1^{st}$ and host plant group. Significant difference in pupal period was noted between $1^{st}$ and 3rd generation group. Emergence rate was the highest in $4^{th}$ generation group followed by $3^{rd}$, host plant, $1^{st}$ and $2^{nd}$ generation group. There is a significant difference in male and female size between $1^{st}$ and $4^{th}$ generation group. Our result indicated that stable rearing of box tree pyralid through the year is possible by artificial diet, and the best adaptation to artificial diet was achieved at $4^{th}$ generation.

Predicting the Occurrence of Generation for Riptortus pedestris (Fabricius) Using Their Body Color (톱다리개미허리노린재의 체색변이를 이용한 발생세대 예측)

  • Lee, Hyoseok;Jung, Jong-Kook;Im, Jae Seong;Park, Marana;Lee, Seunghyun;Lee, Joon-Ho
    • Korean journal of applied entomology
    • /
    • v.54 no.4
    • /
    • pp.431-435
    • /
    • 2015
  • Riptortus pedestris (Fabricius) is one of the important insect pests of leguminous crops, which occurs in most areas of South Korea. It is hard to distinguish each generation in crop fields since not only the longevity of adult R. pedestris is long but also the developmental period is short. Especially, the 2nd generation adults cause enormous damage to soybean while the occurrence time is synchronized with the podding stage of soybean. Controlling the 1st generation of R. pedestris helps to decrease the damage by decreasing the 2nd generation density. This study was conducted to distinguish between the 1st generation and the overwintering generation by using differences in body coloration which is dependent on the day-length during the nymph stage. In addition, the difference was verified by the population dynamics model of R. pedestris. The occurrence time of 1st generation adults could be considered when the summer form is 20% or more. These results will be used for beneficial management decisions to reduce the 2nd generation population.

A Study on the Low Waist Slacks Pattern for the Schoolgirl of a Tween Generation (트윈세대 여학생을 위한 로우 웨이스트 슬랙스 패턴 연구)

  • Shin, Ki-Young;Suh, Mi-A
    • The Research Journal of the Costume Culture
    • /
    • v.18 no.6
    • /
    • pp.1165-1178
    • /
    • 2010
  • This study is aimed at developing low waist slacks pattern with high satisfaction measurements and beauty for the tween generation girls. For this study, the research method was as follows. By extracting and analyzing industrial and educational slacks pattern, beautiful and motion-suitable slacks pattern will be created. This study presents the ideal slacks pattern that has great fit to tween generation girls by comparing and analyzing the previous 2 slacks pattern studies and the real clothing test. The constructed pattern in the 1st step was modified and adjusted from the best industrial patterns' the location of waist line, waist line gradient, rear waist bottom crotch, hip bottom crotch, dart length, the ease of hip girth, the fitness of rear bottom crotch line which were not well-estimated. The 2nd step was appearance and movement test based on the 1st study. In The 3rd step, the 2nd step was chosen as the final slacks study pattern for its superior appearance & movement satisfaction comparing with other patterns.