• 제목/요약/키워드: 2DOF

검색결과 663건 처리시간 0.03초

유연성 구조를 가지는 2 자유도 매니퓰레이터의 힘과 위치 제어 (Hybrid Position/Force Control of 2 DOF Flexible Manipulator)

  • 박선용;이영석;서보혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.389-391
    • /
    • 1996
  • A Hybrid technique is introduced in this paper for a manipulator with 2 DOF flexible links. The manipulator dynamics plus the actuator dynamics is controlled by taking force feedback for the end-effector of the link 2 while controlling the position of link I to control the position of the end-effector.

  • PDF

콘크리트 취급사업장의 공기 중 석영 분석방법 비교 (Analysis of Quartz Concentrations by FTIR-DOF and FTIR-Transfer method in Concrete Manufacturing Industries)

  • 배혜정;정종현;피영규
    • 한국산업보건학회지
    • /
    • 제23권2호
    • /
    • pp.75-83
    • /
    • 2013
  • Objectives: This study was conducted to estimate quartz concentrations in the airborne respirable dust from concrete manufacturing industries and to compare performance of two analytical methods, direct on filter(DOF) and the transfer methods in the Fourier Transform Infrared Spectroscopy(FTIR). Methods: Total 36 area samples were collected from 8 concrete manufacturing industries. Each respirable dust sample was collected by a 25 mm cassette attached to a 10 mm Dorr-Oliver nylon cyclone. The quartz content was estimated using the intensity of the absorption peak of quartz at $799cm^{-1}$ by FTIR. Results: By the comparison of quartz content in respirable dust between the two methods, the results of using DOF method were higher than that of transfer method. And the result of quartz concentrations in respirable dust estimated by DOF method were mostly higher than those by transfer method. Statistically significant difference of quartz concentrations in respirable dust were not found in shakeout, input, loading and transporting processes by two methods. But quartz concentrations in the molding process had the statistically significant difference between DOF and transfer method. Conclusions: The results of the study is suggested that, it be needed to correct the influence of the interferences in order to establish the DOF method when interfering minerals have an effect on quantitative analysis of quartz in respirable dust by the direct on filter method with FTIR.

목표치 필터형 2자유도 PID 제어기를 이용한 공기식 제어밸브의 제어 특성 연구 (A Study on the Characteristic of Control Valve using 2DOF PID Controller with Target Value Filter)

  • 유경렬;김동화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.809-811
    • /
    • 1999
  • The three-mode PID controller is widely used in plant because control algorithm is simple and tuning method is general. But the conventional PID controller can not have the both purpose of setpoint tracking and disturbance rejection at the same time. In this paper, we studied the application 2DOF PID controller to pneumatic control valve through simulation and experiments. Results are Presented a satisfactory response

  • PDF

위치제어를 위한 신경망 2 자유도 PID 제어기 (Two-Degree-of-Freedom PID controller with Neural network for position control)

  • 이정민;하홍곤
    • 융합신호처리학회 학술대회논문집
    • /
    • 한국신호처리시스템학회 2000년도 추계종합학술대회논문집
    • /
    • pp.193-196
    • /
    • 2000
  • ln this paper, we consider to apply of 2-DOF (Degree of Freedom) PID controller at D.C servo motor system. Many control system use I-PD, PIB control system. but the position control system have difficulty in controling variable load and changing parameter We propose neural network 2-DOF PID control system having feature for removal disturbrances and tracking function in the target value point.

  • PDF

Double DOF control of an electromechanical integrated toroidal drive

  • Xu, Lizhong;Liu, Xin
    • Smart Structures and Systems
    • /
    • 제3권1호
    • /
    • pp.115-131
    • /
    • 2007
  • The electromechanical integrated toroidal drive is a new drive system. For the control of the drive, the torque fluctuation and the steady-state errors should be removed and the fast response to the input change should be achieved. In this paper, the torque fluctuation of the drive system is analyzed and expressed as Fourier series forms. The transfer function of the torque control for the drive system is derived from its electromechanical coupled dynamic equations. A 2-DOF control method is used to control the drive system. Using definite parameter relationship of the 2-DOF control system, the steady errors of the torque control for the drive system is removed. Influences of the drive parameters on the control system are investigated. Using proper drive parameters, the response time of the control system is reduced and the quick torque response of the drive system is realized. Using a compensated input voltage, the torque fluctuation of the drive system is removed as well. The compensated input voltage can be obtained from the torque fluctuation equation and the transfer function. These research results are useful for designing control system of the new drive.

Deformation analysis of a 3-DOF parallel manipulator with one or two additional branches

  • Chen, Xiaolei;Wu, Jun;Yu, Guang;Wang, Liping
    • Advances in robotics research
    • /
    • 제1권2호
    • /
    • pp.141-154
    • /
    • 2014
  • Redundant parallel manipulators have some advantages over the nonredundant parallel manipulators. It is important to determine how many additional branches should be introduced. This paper studies whether one or two additional branches should be added to a 3-DOF parallel manipulator by comparing the flexible deformation of a 3-DOF parallel manipulator with one additional branch and that with two additional branches. The kinematic and dynamic models of the redundant parallel manipulator are derived and the flexible deformation is investigated. The flexible deformation of the manipulators with one additional branch and two branches is simulated and compared. This paper is helpful for designers to design a redundantly actuated parallel manipulator.

6 자유도 다축 시뮬레이션 테이블의 역.순기구학 해석 및 검증 (Inverse and Forward Kinematics Analysis of 6 DOF Multi Axis Simulation Table and Verification)

  • 진재현;전승배
    • 대한기계학회논문집A
    • /
    • 제32권2호
    • /
    • pp.202-208
    • /
    • 2008
  • A 6 DOF Multi axis simulation table (MAST) is used to perform vibration and fatigue tests for parts or assemblies of automobiles, aircraft, or other systems. It consists of a table and 6 linear actuators. For its attitude control, we have to adjust the lengths of 6 actuators properly. The system is essentially a parallel mechanism. Three actuators are connected to the table directly and other three actuators are connected indirectly. Because of these, the MAST shows also a serial mechanism#s property: the inverse kinematics is more complicated than a pure parallel mechanism and each actuator can operate independently. The authors have performed a kinematics analysis of the 6 DOF MAST. We have presented an analytical and a numerical solution for the inverse and forward kinematics, and we have verified the solutions by a 3D CAD software.

Experiment and Torque Modeling of Double-Excited, Two-Degree-of-Freedom Motor based on Magnetic Equivalent Circuit Analysis

  • Kim, Young-Boong;Lee, Jae-Sung;Kwon, Byung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.130-136
    • /
    • 2013
  • This paper presents the magnetic equivalent circuit analysis of a double-excited, two-degree-of-freedom (DOF) motor. The double-excited, 2-DOF motor is a laminated structure, making it easy to manufacture and giving it simple operating principles. We explain the structure of the 2-DOF motor and analyze the static characteristics using a magnetic equivalent circuit (MEC) to reduce analysis time. The feasibility of MEC analysis was confirmed by experimental results of the tilting, panning motion. We also confirmed the occurrence of holding torque in every motion.

Microcontroller based split mass resonant sensor for absolute and differential sensing

  • Uma, G.;Umapathy, M.;Kumar, K. Suneel;Suresh, K.;Josephine, A. Maria
    • Smart Structures and Systems
    • /
    • 제5권3호
    • /
    • pp.279-290
    • /
    • 2009
  • Two degrees of freedom resonant systems are employed to improve the resonant property of resonant sensor, as compared to a single degree of freedom resonant system. This paper presents design, development and testing of two degrees of freedom resonant sensor. To measure absolute mass, cantilever shaped two different masses (smaller/absorber mass and bigger/drive mass) with identical resonant frequency are mechanically linked to form 2 - Degree-of-Freedom (DOF) resonator which exhibits higher amplitude of displacement at the smaller mass. The same concept is extended for measuring differential quantity, by having two bigger mass and one smaller mass. The main features of this work are the 3 - DOF resonator for differential detection and the microcontroller based closed loop electronics for resonant sensor with piezoelectric sensing and excitation. The advantage of using microcontroller is that the method can be easily extended for any range of measurand.

Kinematics and Optimization of 2-DOF Parallel Manipulator with Revolute Actuators and a Passive Leg

  • Nam Yun-Joo;Park Myeong-Kwan
    • Journal of Mechanical Science and Technology
    • /
    • 제20권6호
    • /
    • pp.828-839
    • /
    • 2006
  • In this paper, a 2-DOF planar parallel manipulator with two revolute actuators and one passive constraining leg. The kinematic analysis of the mechanism is analytically performed : the inverse and forward kinematics problems are solved in closed forms, the workspace is derived systematically, and the three kinds of singular configurations are round. The optimal design to determine the geometric parameters and the operating limits of the actuated legs is performed considering the kinematic manipulability and workspace size. These results of the paper show the effectiveness of the presented manipulator.