• Title/Summary/Keyword: 2D transfer function

Search Result 199, Processing Time 0.033 seconds

An experimental analysis of vibration-induced noise isolation characteristics of a sonar acoustic sensor (소나 음향센서의 진동유기 소음 차단 특성에 대한 실험적 연구)

  • Kim, Kyungseop;Je, Yub;Kim, Ho-Jun;Cho, Yo-Han;Lee, Jeong-Min;Kim, Donghyeon;Chang, Woosuk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.2
    • /
    • pp.193-199
    • /
    • 2019
  • In this paper, the results of underwater vibration experiment are analyzed to verify platform vibration-induced noise isolation characteristics of a hull-mounted acoustic sensor. The experimental condition causing platform vibration-induced noise is generated using the mock-up hull, where the acoustic sensor is installed, with shaker in an acoustic water tank. The performance indices of ATF (Acceleration Transfer Function), AVS (Acceleration Voltage Sensitivity), and IL (Insertion Loss) for the acoustic sensor are calculated from the output of the standard accelerometers, which are installed on the mock-up hull and the acoustic sensor, and the output signal of the acoustic sensor. The frequency-dependent noise isolation characteristics of the acoustic sensor are analyzed based on the calculated performance indices and an effectiveness of the experiment is examined.

Adenoviral-Mediated Ref-1 Overexpression Potentiates NO Production in Bradykinin-Stimulated Endothelial Cells (Bradykinin으로 자극한 혈관내피세포에서 Ref-1의 세포내 과발현에 의한 NO 생성 증진 효과에 대한 연구)

  • Song, Ju-Dong;Kim, Kang-Mi;Lee, Sang-Kwon;Kim, Jong-Min;Park, Young-Chul
    • Journal of Life Science
    • /
    • v.17 no.7 s.87
    • /
    • pp.905-909
    • /
    • 2007
  • The dual-function protein redox factor-1 (Ref-1) is essential for base excision repair of oxidatively damaged DNA and also governs the activation of many redox-sensitive transcription factors. We examined the role of Ref-1 in regulation of nitric oxide (NO) synthesis employing adenoviral-mediatedoverexpression of Ref-1 in bradykinin-stimulated endothelial cells. Intracellular NO was detected with the NO-sensitive fluorophore DAF-2. Overexpression of Ref-1 potentiates bradykinin-stimulated NO production in endothelial cells. And, cells ifected with AdRef-1 showed higher fluorescence intensity compared with uninfected or AdD1312-infected cells. In parallel with this, over expression of Ref-1 also stimulated endothelial NO synthase (eNOS) enzyme activity, compared with unifected or AdD1312-infected cells, in bradykinin-stimulated cells as well as in unstimulated cells. These results suggest that Ref-1 implicates in endothelium-dependent vasorelaxation resulting from NO production in vascular system.

Forward-Looking Ultrasound Imaging Transducer : I. Analysis and Design (전향 초음파 영상 트랜스듀서 : I. 해석 및 설계)

  • Lee, Chan-Kil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2E
    • /
    • pp.73-86
    • /
    • 1995
  • The transducer section of the forward-looking ultrasound imaging catheter (FLUIC) consists of a circular piezoelectric element as a vibrator and a conical acoustic mirror as a perfect reflector. A small diameter piezoelectric transducer element is mounted on the side of a catheter's rotating shaft. The unique design of FLUIC provides the capability to form a two-dimensional image of a cross-section of vessel in front of the catheter, which is lacking in the present generation of intravascular ultrasound (IVUS) transducers, as well as a conventional side view image. The mirror configuration for the transducer section of the FLUIC is designed using an approximated ray tracing techniques. The diffraction transfer function approach [1] developed for the field prediction from primary sources is generalized and extended to predict the secondary diffraction characterstics from an acoustic mirror. The extended model is verified by simulation and experiment through a simple plane reflector and employed to analyzed the field characteristics of a FLUIC.

  • PDF

Implementation of a portable pulse oximeter for SpO2 using Compact Flash Interface (컴팩트 플래쉬 방식의 휴대용 산소포화도 측정 시스템 구현)

  • Lee, Han;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.678-681
    • /
    • 2003
  • In this paper, we aims to develop a microcontroll er-based portable pulse oximeter using Compact Flash Interface. First, portable pulse oxineter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of SpO$_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patients condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO$_2$ modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact flash interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF

Performance Evaluation of a Selenium(a-Se) Based Prototype Digital Radiation Detector (비정질 셀레늄 기반 디지털 방사선 검출기의 성능 평가)

  • Park, Ji-Koon;Kang, Sang-Sik;Cho, Sung-Ho;Shin, Jung-Wook;Kim, So-Yeong;Son, Dae-Woong;Nam, Sang-Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.300-305
    • /
    • 2007
  • In this study, we have studied the fabrication and the performance evaluation of digital radiation detector of the based on selenium (a-Se) prototype which is widely researched about recently. The detector was fabricated using amorphous selenium in the specification of active area size $7{\times}8.5"$, pixel pitch $139{\mu}m$, and 12 bit ADC. In order for the performance evaluation of the fabricated detector, we used radiation quality RQA 5 that is suggested by the International Electrotechnical Commission (IEC), and evaluated modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Concerning MTF measurement, we used slit camera (Nuclear Associates, Model : 07-624-2222), and evaluated in the slit method. Also so as to compare the performance evaluation on the detector fabricated in this study, we used Hologic Direct-Ray (DR-1000) and GE Revolution XQ/I system, and evaluated and compared in the same method MTF, NPS, and DQE which are image quality factors. And as a result, the MTF of each detector In Nyquist frequency were evaluated to be 58% (at 3.5 lp/mm) in the case of DR-1000 and 65% (at 2.5 lp/mm) in the case of XQ/I, and that for the detector fabricated in this study was evaluated to be 36% (at 3.51 lp/mm). Also in the case of DQE(0), the detector fabricated in this study, DR-1000 of Hologic company, and XQ/I system of GE company respectively were evaluated as 36%, 32%, and 50%.

Strain Selection of Psychrotrophic Leuconostoc mesentroides Producing a Highly Active Dextransucrase from Kimchi (김치로부터 고활성 dextransucrase를 생성하는 저온성 Leuconostoc mesenteroides 균주선발)

  • Eom, Hyun-Ju;Seo, Dong-Mi;Yoon, Hyang-Sik;Lee, Hee-Bong;Han, Nam-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.6
    • /
    • pp.1085-1090
    • /
    • 2002
  • Leuconostoc mesenteroides, the major bacterium in the initial phase of lactate-fermentation in kimchi, produces lactic acid, acetic acid, mannitol, and $CO_2$. It also secrets dextransucrase, which catalyzes the transfer reaction of glucose from sucrose to maltose, synthesizing mainly panose ($6^_2-{\alpha}-D-glucopyranosylmaltose)$, a probiotic oligosaccharide. To use the strain as a starer culture to produce high amount of panose during kimchi fermentation, we screened psychrotrophic strains showing fast growth rate at low temperature among the isolates of Leuconostoc sp. and selected two strains showing high dextransucrase activity. The strains were identified as Leuconostoc mesenteroides, which can be used as function added-starters for lactate-fermented foods.

On Method for LBS Multi-media Services using GML 3.0 (GML 3.0을 이용한 LBS 멀티미디어 서비스에 관한 연구)

  • Jung, Kee-Joong;Lee, Jun-Woo;Kim, Nam-Gyun;Hong, Seong-Hak;Choi, Beyung-Nam
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.169-181
    • /
    • 2004
  • SK Telecom has already constructed GIMS system as the base common framework of LBS/GIS service system based on OGC(OpenGIS Consortium)'s international standard for the first mobile vector map service in 2002, But as service content appears more complex, renovation has been needed to satisfy multi-purpose, multi-function and maximum efficiency as requirements have been increased. This research is for preparation ion of GML3-based platform to upgrade service from GML2 based GIMS system. And with this, it will be possible for variety of application services to provide location and geographic data easily and freely. In GML 3.0, it has been selected animation, event handling, resource for style mapping, topology specification for 3D and telematics services for mobile LBS multimedia service. And the schema and transfer protocol has been developed and organized to optimize data transfer to MS(Mobile Stat ion) Upgrade to GML 3.0-based GIMS system has provided innovative framework in the view of not only construction but also service which has been implemented and applied to previous research and system. Also GIMS channel interface has been implemented to simplify access to GIMS system, and service component of GIMS internals, WFS and WMS, has gotten enhanded and expanded function.

  • PDF

A Study on the Implementation of the Multi-Process Structured ISDN Terminal Adaptor for Sending the Ultra Sound Medical Images (다중처리 구조를 갖는 초음파 의료영상 전송용 ISDN(Integrated Services Digital Network) TA(Terminal Adaptor) 구현에 관한 연구)

  • 남상규;이영후
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.3
    • /
    • pp.317-324
    • /
    • 1994
  • This paper proposed a new method in the implementation of ISDN (integrated services digital network) LAPD (link access procedure on the D-channel) and LAPB (link access procedure on the B-channel) protocols. The proposed method in this paper implement ISDW LAPD protocol through multi-tasking operating system and adopt a kernel part that is changed operating system to target board. The features of implemented system are (1) the para.llel processing of the events generated at each layer, as follows (2) the supporting necessary timers for the implementation of ISDW LAPD protocol from the kernel part by using software, (3) the recommanded SAP (Service Access Point) from CCITT was composed by using port function in the operating system. With the proposed method, the protocols of ISDH layerl, layer2 and layer3 (call control) were implemented by using the kernel part and related tests were carried out by connecting the ISDH terminal simulator to ISDN S-interface system using the ISDN LAPD protocol The results showed that ISDW S-interface terminals could be discriminated by TEI (Terminal Equipment Identifier) assignment in layer 2 (LAPD) and the message transmission of layer 3 was verified by establishing the multi-frame transmission and then through the path established by the LAPD protocol, a user data was tranfered and received on B-channel with LAPB protocol Thererfore, as new efficient ISDN S-interface environment was implemented in the thesis, it was verified that the implemented system can be utilized by connecting ISDW in the future to transfer a medical image data.

  • PDF

Design and Implementation of Telematics Contents Gateway Based on Interoperability (상호운영성 기반의 텔레매틱스 컨텐츠 게이트웨이 설계 및 구현)

  • Kim, Do-Hyun;Min, Kyoung-Wook;Jang, Byung-Tae;Li, Ki-Joune
    • The KIPS Transactions:PartD
    • /
    • v.14D no.2
    • /
    • pp.249-264
    • /
    • 2007
  • As the need for telematics contents services due to the frequent traveling of people is increasing, it is necessary to provide various telematics contents by connecting and integrating current telematics contents which are collected and provided by each individual data provider. However, it is difficult to integrate or exchange the current telematics contents, because the data providers use different telematics contents models. Therefore, we propose a 'telematics contents gateway(TCG); system, which enables to integrate different telematics contents, so that the contents can be interoperable. The TCG can be a solution for several problems in the current telematics contents providing system. First of all, it has been impossible to search the contents without any information about data providers, because of the absence of metadata in the current systems. For this problem, TCG supports a search function based on a web-service technology. Second, TCG provides a common road network model for interoperability, and the model can be a solution to integrate different road network models into the common model. Moreover, integration algorithm for enhancing the correctness of integration will be proposed. In addition, it is designed by multi threads and multi queue structure. The TCG developed with C# on a windows system has been running and we verified that there was no information loss in the integration process. In addition, the speed of content integration and transfer satisfied the requirement of telematics services providers.

Evaluation of Image Qualities for a Digital X-ray Imaging System Based on Gd$_2$O$_2$S(Tb) Scintillator and Photosensor Array by Using a Monte Carlo Imaging Simulation Code (몬테카를로 영상모의실험 코드를 이용한 Gd$_2$O$_2$S(Tb) 섬광체 및 광센서 어레이 기반 디지털 X-선 영상시스템의 화질평가)

  • Jung, Man-Hee;Jung, In-Bum;Park, Ju-Hee;Oh, Ji-Eun;Cho, Hyo-Sung;Han, Bong-Soo;Kim, Sin;Lee, Bong-Soo;Kim, Ho-Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.253-259
    • /
    • 2004
  • in this study, we developed a Monte Carlo imaging simulation code written by the visual C$\^$++/ programing language for design optimization of a digital X-ray imaging system. As a digital X-ray imaging system, we considered a Gd$_2$O$_2$S(Tb) scintillator and a photosensor array, and included a 2D parallel grid to simulate general test renditions. The interactions between X-ray beams and the system structure, the behavior of lights generated in the scintillator, and their collection in the photosensor array were simulated by using the Monte Carlo method. The scintillator thickness and the photosensor array pitch were assumed to 66$\mu\textrm{m}$ and 48$\mu\textrm{m}$, respertively, and the pixel format was set to 256 x 256. Using the code, we obtained X-ray images under various simulation conditions, and evaluated their image qualities through the calculations of SNR (signal-to-noise ratio), MTF (modulation transfer function), NPS (noise power spectrum), DQE (detective quantum efficiency). The image simulation code developed in this study can be applied effectively for a variety of digital X-ray imaging systems for their design optimization on various design parameters.