• Title/Summary/Keyword: 2D scanner

Search Result 403, Processing Time 0.024 seconds

Low-Complexity Handheld 3-D Scanner Using a Laser Pointer (단일 레이저 포인터를 이용한 저복잡도 휴대형 3D 스캐너)

  • Lee, Kyungme;Lee, Yeonkyung;Park, Doyoung;Yoo, Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.458-464
    • /
    • 2015
  • This paper proposes a portable 3-D scanning technique using a laser pointer. 3-D scanning is a process that acquires surface information from an 3-D object. There have been many studies on 3-D scanning. The methods of 3-D scanning are summarized into some methods based on multiple cameras, line lasers, and light pattern recognition. However, those methods has major disadvantages of their high cost and big size for portable appliances such as smartphones and digital cameras. In this paper, a 3-D scanning system using a low-cost and small-sized laser pointer are introduced to solve the problems. To do so, we propose a 3-D localization technique for a laser point. The proposed method consists of two main parts; one is a fast recognition of input images to obtain 2-D information of a point laser and the other is calibration based on the least-squares technique to calculate the 3-D information overall. To verified our method, we carry out experiments. It is proved that the proposed method provides 3-D surface information although the system is constructed by extremely low-cost parts such a chip laser pointer, compared to existing methods. Also, the method can be implemented in small-size; thus, it is enough to use in mobile devices such as smartphones.

Comparative Analysis of Body Measurement and Fit Evaluation between 2D Direct Body Measuring and 3D Body Scan Measuring (직접측정과 3차원 측정에 따른 인체치수 및 의복 착장 비교분석)

  • Istook, Cynthia L.;Lim, Ho-Sun;Chun, Jong-Suk
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.6
    • /
    • pp.1347-1358
    • /
    • 2011
  • This study purposed to analyze differences in body measurement between the 2D direct body measuring method and the 3D body scan measuring method and to perform the appearance evaluation and cross-sectional evaluation of the fit of pants to which body measurements obtained by each measuring method were applied. Body measuring was conducted in 10 women in their 20s-30s using 2D direct body measuring and 3D automatic measuring with Hamamatsu body scanner. Among the 10 women, 3 participated in experimental garment wearing. Experimental pants were made using their 2D direct body measurements and 3D automatic measurements, and wearing tests were performed through expert evaluation and cross-sectional evaluation. The results of the experiment were as follows. According to the results of comparative analysis on differences between 2D direct body measurements and 3D scan measurements, 3D automatic measurements were significantly larger in bust circumference, ankle circumference, armscye circumference, shoulder length, scye depth, and arm length. As circumferences measured with the 3D body scanner were somewhat larger than directly measured ones, it is suggested to adjust ease when using existing pattern making methods. We prepared experimental garments by the same pattern making method through applying body measurements obtained with the two measuring methods, and assessed the fit of the garment comparatively through expert evaluation and 3D scan cross-sectional evaluation. According to the results, 2D-pants using 2D direct body measurements was slightly tighter than 3D-pants using 3D measurements in waist circumference, hip circumference, and abdominal circumference. In the results of comparing appearance in terms of the fit of the experimental garment in each subject, significant difference was observed in most of the compared items. This result suggests that 3D automatic body measuring data may show different accuracy according to body shape and therefore it is necessary to examine difference between 2D direct body measurements and 3D automatic measurements according to body shape.

Mechanical Alignment of Hull Mounted Phased Array Radar on the Separated Mast (분리된 마스트에 설치되는 선체고정 위상 배열 레이더의 기계적 정렬)

  • Seo, Hyeong-Pil;Kim, Dae-Han;Kim, Joon-Woo;Lee, Kyung-Jin;Cho, Kyu-Lyong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.465-473
    • /
    • 2019
  • This paper is meaningful as the first case where a 4 - sided hull-fixed phased array radar was installed on a mast separated from Korea and the alignment was verified. The mechanical alignment method was studied for accurately mounting two separate masts for naval ships and the 3D scanner for alignment. Hull-fixed phased array radar uses very high frequency, so the short wavelength can cause a phase difference of the device due to the small positional error. Since the array antenna is fixed with the hull, it has higher accuracy control than the rotary radar for 4 array surfaces. The study describes a method of checking the flatness of two radar masts manufactured at a factory, a method of aligning masts in a shipyard, and a method of aligning four array pad mounting surfaces. As a tool for this, a 3D laser scanner and a software-based method for comparing survey results with 3D CAD are used. This paper is meaningful as the first example of installing a four-sided hull-fixed phased array radar on a separate mast from a Korean naval ship and deriving a mechanical alignment method.

A Study on the Dressed Shapes of the Blouse with Short Sleeves and Sleeveless according to Arm Movement Using 3-D Scanner (팔 동작에 따른 소매유무별 블라우스 착의형상의 3차원적 파악)

  • Lee, Myung-Hee;Matsuyama, Yoko
    • Fashion & Textile Research Journal
    • /
    • v.8 no.2
    • /
    • pp.209-213
    • /
    • 2006
  • The 3-D information is useful as basic data which has been utilized in the development of simulating technology as fit-simulation. The experiment is designed to take some useful data on the variant shapes which contribute in simulating the adaptability of the clothes. The general figure of the clothes are made after the figure of the basic standing posture of the human body. The shape of the clothes fits with kinetic characteristic of the human body as the form of the clothes gets twisted, the ease of the clothes changes, and the clothes itself expands. We studied the dressed shapes of blouse according to two types of the arm movement(basic posture and reach forward) and three types of clothes(foundation, blouse with short sleeves and sleeveless) in the sit-down-posture. We accomplished some experimental data on three-dimensional measurement of the dressing shapes using TDS-3100 3-D scanner made in Japan PULSTECH. It is considered that the variant of shapes and distribution of gaps in the dressed shapes of blouse are determined by the adaptability of clothes made in arm movement.

A NOVEL 3D SCAN METHOD TO QUANTIFY TEETH WEAR (3-Dimensional scan을 이용한 치아 마모량 측정 방법에 관한 연구)

  • Kim Seung-June;Choi Dae-Gyun;Kwon Kung-Rock;Lee Seok-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Statement of problem : Tooth wear is physiological phenomenon. Ninety-seven percent of normal people have tooth wear and about 7% has pathologic teeth wear. If we know the amount of tooth surface loss caused by pathologic tooth wear, we may restore it ideally Purpose : Recently measurement of tooth wear by using 3D scan has been increasing. Therefore, we need to know how accurate 3D scan is. Past accuracy test on 3D scan was about linear change, but as we know that tooth wear is volume change. Thus, the purpose of this study is to know how accurate 3D scan is. Material and Methods : For accuracy test of 3D scanner volume values measured by 3D scanner and micro-balance were compared. For test I, preliminary, 3 ball samples and 3 circular cones were made with pattern resin. For test II, 10 teeth shape rubber samples were used. Results and Conclusion : 1. The result of the accuracy test on 3D scan with 3 ball samples and 3 circular cones made of pattern resin has no significant difference(p<0.05). 2. The result of the accuracy test on 3D scan with 10 samples of tooth shape rubber has no significant difference (p<0.05). As a result, we may concluded the analysis of quantifying tooth wear used by 3D scan is useful in the clinic.

Tracking of Person Walking Pattern and Trajectory Following with 2D Laser Scanner (레이저 스케너 센서기반 보행패턴 인식 및 경로추적)

  • Jin, Taeseok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.903-909
    • /
    • 2018
  • We propose laser scanner sensor system based walking pattern and tracking method of multiple human. This system uses laser scanners sensors and is applicable to wide and crowded area such as hospital and medical care center. The primary objective of this research is to promote the development of robust, repeatable and transferable software for security system that can automatically detect, track and follow people in public area. We developed the method of human identification for this system. Our method is following: 1. Best-walking pattern data are obtained by the help of human position and direction data obtained by laser scanners. 2. Human identification is conducted by calculating the correlation between the step length of walking human. It becomes possible to conduct human identification even in crowded scenes by estimating the movements of waling human' feet are periodic. In the experiment in the station, some effectiveness of this method became clear.

2D Grid Map Compensation using an ICP Algorithm (ICP 알고리즘을 이용한 2차원 격자지도 보정)

  • Lee, Dong-Ju;Hwang, Yu-Seop;Yun, Yeol-Min;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.11
    • /
    • pp.1170-1174
    • /
    • 2014
  • This paper suggests using the ICP (Iterative Closet Point) algorithm to compensate a two-dimensional map. ICP algorithm is a typical algorithm method using matching distance data. When building a two-dimensional map, using data through the value of a laser scanner, it occurred warping and distortion of a two-dimensional map because of the difference of distance from the value of the sensor. It uses the ICP algorithm in order to reduce any error of line. It validated the proposed method through experiment involving matching a two-dimensional map based reference data and measured the two-dimensional map.

The design of XYZ 3-axis stage for AFM system (AFM 시스템을 위한 XYZ 3축 스테이지의 설계)

  • 김동민;김기현;심종엽;권대갑;엄천일
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.36-36
    • /
    • 2002
  • To Establish of standard technique of length measurent in 2D plane, we develope AFM system. The XY scanner scans the sample only in XY plane, while the Z scanner scans the specimen only in Z-direction. Cantilever tip is controlled to has constant height relative to speciman surface by feedback of PSPD signal. To acquire high accuracy, Z-axis measuring sensor will be added.(COXI or others). In this paper we design XYZ stage suitable for this AEM system. For XY stage, single module parallel-kinnematic flexure stage is used which has high orthogonality and minimum out-of-plane motion. To obtain best performance optimal design is performed. For XY stage, to be robust about parasitic motion optimal design of maximizing Z and tilt stiffness is performed under the constraint of motion range and stage size. And for Z stage, optimal design of maximizing 1st resonant frequency is performed. Because if resonant frequency is get higher, scan speed is improved. So it makes reduce the error by sensor drift. Resultly XYZ stage each have 1st natural frequency of 115㎐, 201㎐, 2.66㎑ and range 109㎛, 110㎛, 12㎛.

  • PDF

The Change of Facial Contouring after Facial Massage (안면 수기 마사지 후 안모의 변화)

  • Im, Eun-Jin;We, Soo-Young;Jung, Da-Woon;Kim, Seong-Taek
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.1
    • /
    • pp.103-108
    • /
    • 2012
  • This study was carried out to qualitatively examine the effect of hand massage on facial contour treatment. In the research, the hand massage was carried out to do facial treatments 2 times a week, total 20 times for 10 weeks on women in their 20s~40s. 3D Laser Scanner was used to analyze. The change of facial volume decreased by $731mm^3$ (p>.05), the thickness of cheekbone area decreased by 0.40mm(p<.05) and the thickness of mastication area decreased by 0.44mm after hand massage(p<.05) By above-mentioned findings, hand massage is likely to be an effective treatment for the reduction of facial volume, the thickness of cheekbone area and mastication area to be basic data of establishing facial line treatment methods.