The Usefulness of 4D Echocardiographic Modality for Assessing RV Affection in Uncontrolled Hypertensive Patients

  • Rehab M. Hamdy;Shaimaa A Habib;Layla A Mohamed;Ola H. Abd Elaziz
    • Journal of Cardiovascular Imaging
    • /
    • v.30 no.4
    • /
    • pp.279-289
    • /
    • 2022
  • BACKGROUND: In many cardiovascular disorders, the contractile performance of the right ventricle (RV) is the primary determinant of prognosis. For evaluating RV volumes and function, 4 dimensional (4D)-echocardiography has become common. This research used 2D and 4D modalities to assess RV contractile performance in hypertensive patients. METHODS: A total of 150 patients with essential hypertension were enrolled in this study, along with 75 age and sex-matched volunteers. Clinical evaluation and echocardiographic examination (including M-mode, tissue Doppler imaging, and 2D speckle tracking) were conducted on all participants. RV volumes, 4D-ejection fraction (EF), 4D-fractional area change (FAC), 4D-tricuspid annular plane systolic excursion (TAPSE), 4D-septal and free wall (FW) strain were all measured using 4D-echocardiography. RESULTS: Hypertensive patients showed 2D-RV systolic and diastolic dysfunction (including TAPSE, 2D-right ventricular global longitudinal strain, RV-myocardial performance index and average E/EaRV) and 4D-RV impairment (including right ventricular EF, FAC, RV strain and TAPSE, right ventricular end-diastolic volume and right ventricular end-systolic volume) compared to the control group. We verified the prevalence of RV systolic dysfunction in hypertension patients using the following parameters: 1) 15% of them had 2D-TAPSE < 17 mm vs. 40% by 4D-TAPSE; 2) 25% of them had 2D-GLS < 19% vs. 42% by 4D-septal strain and 35% by 4D FW strain; 3) 35% of hypertensive patients had 4D-EF < 45%; and finally; 4) 25% of hypertensive patients had 2D-FAC < 35% compared to 45% by 4D-FAC. CONCLUSIONS: The incidence of RV involvement was greater in 4D than in 2D-modality trans-thoracic echocardiography. We speculated that 4D-echocardiography with 4D-strain imaging would be more beneficial for examining RV morphology and function in hypertensive patients than 2D-echocardiography, since 4D-echocardiography could estimate RV volumes and function without making geometric assumptions.

Analysis of Myocardial Function Using Gated Myocardial SPET : Comparison of QGS, 4D-MSPECT Software and Echocardiography (게이트 심근관류 SPECT를 이용한 심기능 분석: 정량분석 소프트웨어 QGS, 4D-MSPECT 및 심초음파법의 비교)

  • Lee, Seok-Mo;Bae, Sang-Kyun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.435-443
    • /
    • 2008
  • Purpose: Gated myocardial perfusion SPECT provides not only myocardial perfusion status but also various functional parameters of left ventricle. We compared left ventricular ejection fraction, end-diastolic volume, LV mass by cardiac SPECT using Quantitative Gated SPECT (QGS), 4D-MSPECT software and standard 2D-echocardiography. Materials and Methods: One hundred fourteen patients (male 51, female 63; 29-85 years old, mean $61.3\;{\pm}\;13.3$ years old) with normal perfusion status on Tc-99m tetrofosmin gated myocardial perfusion SPECT were analyzed retrospectively. Ejection fraction (LVEF), End-diastolic volume (LVED), LV mass (LVM) were calculated using QGS, 4D-MSPECT, and LVEF, LVM using 2D-echocardiography. Statistical analysis including Bland-Altman plot was performed using $MedCalc^{(R)}$ (MedCalc software, Mariakerke, Belgium). Results: The correlation of LVEF between methods was good: 0.95/0.96 (stress/rest) between QGS and 4D-MSPECT, 0.79 between QGS and echocardiography, 0.79 between 4D-MSPECT and echocardiography (p<0.001). Using Bland-Altman plot, the 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -12.7% to 7.3% / from -12.2% to 6.5% (stress/rest). The agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -17.4% to 24.0%, and -14.8% to 27.0% respectively. The correlation of LVM between methods was also good: 0.95 between QGS and 4D-MSPECT, 0.76 between QGS and echocardiography, 0.73 between 4D-MSPECT and echocardiography (p<0.001). The 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -33.8g to 14.1g (stress/rest), The 95% confidence interval of agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -148.7 g to 21.8. g, and -142.8 g to 35.5 g, respectively. Conclusion: There was a good correlation for LVEF, LVEO, LVM among methods (QGS, 4D-MSPECT, echocardiography), but the variance between methods was big. Therefore, the functional parameters by each method cannot be used interchangeably.

Utility of 3D Echocardiography for Device Sizing During Transcatheter ASD Closure: A Comparative Study

  • Avinash Mani;Sivadasanpillai Harikrishnan;Bijulal Sasidharan;Sanjay Ganapathi;Ajit Kumar Valaparambil
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.4
    • /
    • pp.180-187
    • /
    • 2023
  • BACKGROUND: Two-dimensional (2D) transesophageal echocardiography (TEE) is commonly used for assessing patients undergoing transcatheter atrial septal defect (ASD) device closure. 3D TEE, albeit providing high resolution en-face images of ASD, is used in only a fraction of cases. We aimed to perform a comparative analysis between 3D and 2D TEE assessment for ASD device planning. METHODS: This was a prospective, observational study conducted over a period of one year. Patients deemed suitable for device closure underwent 2D and 3D TEE at baseline. Defect characteristics, assessed separately in both modalities, were compared. Using regression analysis, we aimed to derive an equation for predicting device size using 3D TEE parameters. RESULTS: Thirty patients were included in the study, majority being females (83%). The mean age of the study population was 40.5 ± 12.05 years. Chest pain, dyspnea and palpitations were the common presenting complaints. All patients had suitable rims on 2D TEE. A good agreement was noted between 2D and 3D TEE for measured ASD diameters. 3D TEE showed that majority of defects were circular in shape (60%). The final device size used had high degree of correlation with 3D defect area and circumference. An equation was devised to predict device size using 3D defect area and circumference. The mean device size obtained from the equation was similar to the actual device size used in the study population (p = 0.31). CONCLUSIONS: Device sizing based on 3D TEE parameters alone is equally effective for transcatheter ASD closure as compared to 2D TEE.

Echocardiographic evaluation of heart failure in dogs with myxomatous mitral valve disease: a retrospective study

  • Han, Donghyun;Lee, Dong-Guk;Jung, Dong-In
    • Journal of Biomedical and Translational Research
    • /
    • v.19 no.4
    • /
    • pp.79-85
    • /
    • 2018
  • Echocardiography is one of the most useful diagnostic techniques for differentiating heart disease as well as mitral valve lesion. Forty client-owned small breed dogs (weight, 2.3-13.2 kg) aged between 8-17 years with myxomatous mitral valve degeneration (MMVD) were included in the present study. The diagnosis of MMVD in dogs was made based on the clinical signs, chest radiography data, and echocardiographic findings. Echocardiographic examinations were conducted in accordance with recommended standards for dogs. M-mode, Doppler, and 2D echocardiography were performed in left and right lateral recumbency. 2D echocardiography was used to measure LA and Ao diameter from 2D short axis at the level of the aortic valve. In the comparison of conventional echocardiography indices in dogs with different stages of heart failure with MMVD, significant differences were observed in E/A ratio (p=0.005), EDV (p<0.001), EDVI (p<0.001), E-peak velocity (p= 0.001), ESV (p=0.028), ESVI (p=0.004), LA (p<0.001), LA/Ao Ratio (p<0.001), LVIDd (p<0.001), LVIDd/Ao Ratio (p<0.001), LVIDs (p=0.036), LVIDs/Ao Ratio (p=0.002), and MR Velocity (p=0.026). In addition, distinct correlations were found in EDV (r=0.712), LA/Ao ration (r=0.830), LVIDd (r=0.724), and LVIDd/Ao ratio (r=0.759). This study found that known conventional echocardiographic indices, including EDV, LA/Ao ratio, LVIDd dimension, and LVIDd/Ao ratio correlated with the severity of MMVD in point of significant differences and distinct correlations.

Dilated Cardiomyopathy in Dogs (개의 확장성 심근증)

  • 최지혜;안용주;이희천;최호정;장동우;엄기동;이영원;권오경;윤정희
    • Journal of Veterinary Clinics
    • /
    • v.16 no.2
    • /
    • pp.509-513
    • /
    • 1999
  • Dilated cardiomyopathy in two dogs showing dyspnea was diagnosed at veterinary teaching hospital. In radiographs, cardiomegaly, pleural effusion, pulmonary edema, ascites, and hepatomegaly were seen at case 1. ‘Reversed D’ shape due to right heart enlargement was shown at case 2. In echocardiography, dilatation of chambers was predominant in case 1 and 2. Arrythmia was complicated in case 2.

  • PDF

Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports

  • Gustavo Gavazzoni Blume;Luka David Lechinewski;Isabela Pedroza Vieira;Nadine Clausell;Giovana Paludo Bertinato;Paulo Andre Bispo Machado-Junior;Pedro Goulart Berro;Lidia Ana Zytynski Moura;Teresa Tsang
    • Journal of Cardiovascular Imaging
    • /
    • v.30 no.1
    • /
    • pp.25-34
    • /
    • 2022
  • BACKGROUND: The purpose of this study was to assess the utility of a handheld device (HH) used during common daily practice and its agreement with the results of a standard echocardiography study (STD) performed by experienced sonographers and echocardiographer. METHODS: A prospective follow-up was conducted in an adult outpatient echocardiography clinic. Experienced sonographers performed the STD and an experienced echocardiographer performed the HH. STD included 2-dimensional images, Doppler and hemodynamics analysis. Hemodynamic assessment was not performed with the HH device because the HH does not include such technology. The images were interpreted by blinded echocardiographers, and the agreement between the reports was analyzed. RESULTS: A total of 108 patients were included; and the concordance for left ventricle (LV) ejection fraction (EF), wall motion score index, LV and right ventricle (RV) function, RV size, and mitral and aortic stenosis was excellent with κ values greater than 0.80. Wall motion abnormalities had good concordance (κ value 0.78). The agreement for LV hypertrophy, mitral and aortic regurgitation was moderate, and tricuspid and pulmonary regurgitation agreements were low (κ values of 0.26 and 0.25, respectively). CONCLUSIONS: In a daily practice scenario with experienced hands, HH demonstrated good correlation for most echocardiography indications, such as ventricular size and function assessment and stenosis valve lesion analyses.

Surgical Treatment of Complete Atrioventricular Septal Defect with Tetralogy of Fallot - one case - (활로씨 4징증을 동반한 완전방실중격결손의 수술치험;1례 보고)

  • Kim, Keun;Chang, Bong-Hyun;Lee, Jong-Tae;Kim, Kyu-Tae
    • Journal of Chest Surgery
    • /
    • v.25 no.8
    • /
    • pp.832-836
    • /
    • 1992
  • A 25-month-old patient with complete atrioventricular septal defect and Tetralogy of Fallot underwent repair of both anomalies. The diagnosis was established preoperatively by 2D-echocardiography, cardiac catheterization and cardioangiogram, Repair was accomplished using cardiopulmonary bypass and profound hypothermia to 18C, Closing of the atrioventricular septal defect was achieved with the use of two Dacron patchs by an atrial approach alone. Infundibulectomy and outflow tract reconstruction with the transannular pericadial patch containing a monocusp were performed. Upon the postoperative evaluation by 2D-echocardiography, mitral regurgitation was absent, but a tiny dehiscence of ventricular patch and minimal tricuspid regurgitation were noticed.

  • PDF

Characteristics and Clinical Outcomes of Cancer Patients who Developed Constrictive Physiology After Pericardiocentesis

  • Hyukjin Park;Hyun Ju Yoon;Nuri Lee;Jong Yoon Kim;Hyung Yoon Kim;Jae Yeong Cho;Kye Hun Kim;Youngkeun Ahn;Myung Ho Jeong;Jeong Gwan Cho
    • Korean Circulation Journal
    • /
    • v.52 no.1
    • /
    • pp.74-83
    • /
    • 2022
  • Background and objectives: This study aimed to identify the characteristics and clinical outcomes of cancer patients who developed constrictive physiology (CP) after percutaneous pericardiocentesis. Methods: One-hundred thirty-three cancer patients who underwent pericardiocentesis were divided into 2 groups according to follow-up echocardiography (CP vs. non-CP). The clinical history, imaging findings, and laboratory results, and overall survival were compared. Results: CP developed in 49 (36.8%) patients after pericardiocentesis. The CP group had a more frequent history of radiation therapy. Pericardial enhancement and malignant masses abutting the pericardium were more frequently observed in the CP group. Fever and ST segment elevation were more frequent in the CP group, with higher C-reactive protein levels (6.6±4.3mg/dL vs. 3.3±2.5mg/dL, p<0.001). Pericardial fluid leukocytes counts were significantly higher, and positive cytology was more frequent in the CP group. In baseline echocardiography before pericardiocentesis, medial e' velocity was significantly higher in the CP group (8.6±2.1cm/s vs. 6.5±2.3cm/s, p<0.001), and respirophasic ventricular septal shift, prominent expiratory hepatic venous flow reversal, pericardial adhesion, and loculated pericardial fluid were also more frequent. The risk of all-cause death was significantly high in the CP group (hazard ratio, 1.53; 95% confidence interval,1.10-2.13; p=0.005). Conclusions: CP frequently develops after pericardiocentesis, and it is associated with poor survival in cancer patients. Several clinical signs, imaging, and laboratory findings suggestive of pericardial inflammation and/or direct malignant pericardial invasion are frequently observed and could be used as predictors of CP development.

A study on improvement of misdiagnosis rate in aortic regurgitation disease by physically correcting EF in 2D echo cardiography (대동맥판 역류질환 진단시 이면성심초음파 박출계수의 보정을 통한 오진율 개선에 관한 연구)

  • Choi, Kwan-Woo;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2142-2147
    • /
    • 2012
  • This study is aimed at decreasing wrong diagnosis with corrected EF(Ejection Fraction) of 2D echo cardiography by analysing the physical time-resolution difference between Cine MRI and 2D echo cardiography and applying the corrected EF in 2D echocardiography. From February 2010 to December 2011, among the 110 patients who had undergone both 2D echo cardiography and cine MRI only 37 patient were selected suffering aortic valve regurgitation. ED, ES and SV were measured and EF was calculated in each system while normal ranges of Cine MRI and 2D echocardiography were compared to evauate misdiagnosis rate. The correlation of physical time resolution between 2D echocardiography and MRI was evaluated and the differences were corrected with linear regression coefficient which is derived from linear regression analysis. Blandt-Altman plot was used to evaluate the reliability of corrected 2D echo cardiography EF and compare the error among measured values. The values were compared with MRI normal range and misdiagnosis rate was measured again. As a result, misdiagnosis rates of physical time resolution were measured to be 32.4%(12people) before the correction of EF and 18.9%(7people) after the correction. Also, EF confirmed in Blandt-Altman plot were almost the same with MRI EF. In conclusion, when diagnosing aortic regurgitation disease, simply using 2D echocardiography can easily raise the misdiagnosis rates, therefore considering the MRI machine's physical merits, correcting the time resolution difference is important by calculating time resolution wrong diagnosis would decrease and it is considered to be useful in clinical circumstances.