• 제목/요약/키워드: 2D direct body measurement

검색결과 17건 처리시간 0.022초

체표면분할법에 의한 성인 남성용 피티드 토르소형 원형 설계 (Development of Male Fitted Torso Type Basic Patterns According to the Body Surface Segment Method)

  • 서추연
    • 한국의류학회지
    • /
    • 제33권7호
    • /
    • pp.1109-1120
    • /
    • 2009
  • This study develops a fitted torso type basic pattern for men by utilizing 3D body scan data. Recent fashion trends are reflected in the development of the pattern. The subjects were 15 men in their 20's, who wear size 95 (M size). Body scan data was obtained through a 3D whole body scanner (WB4, Cyberware, USA), and a body surface development figure for developing male fitted torso type basic pattern was attained through the use of Rapid Form 2006 as well as Auto CAD 2006 programs. The results are as follows: A body surface development figure through body surface segment method showed high exactitude in an error range of 100$\pm$1%. In addition, it occurred in an error range of 100:1:3% because of the hard scanning conditions in the incline of the shoulder and armpit areas. However, the body surface development figure as well as the direct measurement results can be used as basic data for the given patternmaking since the error range falls into 100$\pm$3%. Dart amounts obtained from the average cross section were center back 2.2cm (24.3%), back armpit point 3.8cm (41.8%), front armpit point 3.0cm (33.9%). As shown the jacket pattern, the biggest dart amount was portioned out at the back armpit point. The drafting equations for the development pattern acquired are as follows; Full width=C/2+5cm, back length=height/4-1cm, armhole depth=(C/10+12cm)+3cm, back width=2C/10+2cm, front width=2C/10. The development pattern was a fitted torso basic pattern that was composed of 3 pieces, so it would be very useful in developing shirt or jacket patterns. According to the results of the evaluation of the developed pattern appearance, it obtained higher scores of over 3.5 points in almost items, meaning that the developed pattern is appropriate for a male fitted torso type basic pattern. It suggests a possibility of patternmaking from a body surface development figure in 2-D to prototype.

Customized 3D Printed Bolus for Breast Reconstruction for Modified Radical Mastectomy (MRM)

  • Ha, Jin-Suk;Jung, Jae Hong;Kim, Min-Joo;Jeon, Mi Jin;Jang, Won Suk;Cho, Yoon Jin;Lee, Ik Jae;Kim, Jun Won;Suh, Tae Suk
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.196-202
    • /
    • 2016
  • We aim to develop the breast bolus by using a 3D printer to minimize the air-gap, and compare it to commercial bolus used for patients undergoing reconstruction in breast cancer. The bolus-shaped region of interests (ROIs) were contoured at the surface of the intensity-modulated radiation therapy (IMRT) thorax phantom with 5 mm thickness, after which the digital imaging and communications in mdicine (DICOM)-RT structure file was acquired. The intensity-modulated radiation therapy (Tomo-IMRT) and direct mode (Tomo-Direct) using the Tomotherapy were established. The 13 point doses were measured by optically stimulated luminescence (OSLD) dosimetry. The measurement data was analyzed to quantitatively evaluate the applicability of 3D bolus. The percentage change of mean measured dose between the commercial bolus and 3D-bolus was 2.3% and 0.7% for the Tomo-direct and Tomo-IMRT, respectively. For air-gap, range of the commercial bolus was from 0.8 cm to 1.5 cm at the periphery of the right breast. In contrast, the 3D-bolus have occurred the air-gap (i.e., 0 cm). The 3D-bolus for radiation therapy reduces the air-gap on irregular body surface that believed to help in accurate and precise radiation therapy due to better property of adhesion.

Evaluations and Comparisons of Body Surface Doses during Breast Cancer Treatment by Tomotherapy and LINAC Radiotherapy Devices

  • Lee, Hyun-Jik;Bae, Sun-Hyun;Cho, Kwang Hwan;Jeong, Jae-Hong;Kwon, Su-Il;Lee, Kil-Dong
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.218-225
    • /
    • 2017
  • Effects on skin caused by the dose from linear accelerator (LINAC) opposing portal irradiation and TomoDirect 3-D modeling treatment according to the radiation devices and treatment methods were measured, and a comparative analysis was performed. Two groups of 10 patients each were created and measurements were carried out using an optically stimulated luminescence dosimeter. These patients were already receiving radiation treatment in the hospital. Using the SPSS statistical program, the minimum and maximum average standard deviations of the measured skin dose data were obtained. Two types of treatment method were selected as independent variables; the measured points and total average were the dependent variables. An independent sample T-test was used, and it was checked whether there was a significance probability between the two groups. The average of the measured results for the LINAC opposing portal radiation was 117.7 cGy and PDD 65.39% for the inner breast, 144.7 cGy and PDD 80.39% for the outer breast, 143.2 cGy and PDD 79.56% for the upper breast, 151.4 cGy and PDD 84.11% for the lower breast, 149.6 cGy and PDD 83.11% for the axilla, and 141.32 cGy and PDD 78.51% for the total average. In contrast, for TomoDirect 3-D conformal radiotherapy, the corresponding measurement values were 137.6 cGy and PDD 76.44%, 152.3 cGy and PDD 84.61%, 148.6 cGy and PDD 82.56%, 159.7 cGy and PDD 88.72%, and 148.6 cGy PDD 82.56%, respectively, and the total average was 149.36 cGy and PDD 82.98%. To determine if the difference between the total averages was statistically significant, the independent sample T-test of the SPSS statistical program was used, which indicated that the P-value was P=0.024, which was 0.05 lower than the significance level. Thus, it can be understood that the null hypothesis can be dismissed, and that there was a difference in the averages. In conclusion, even though the treatment dose was similar, there could be a difference in the dose entering the body surface from the radiation treatment plan; however, depending on the properties of the treatment devices, there is a difference in the dose affecting the body surface. Thus, the absorbed dose entering the body surface can be high. During breast cancer radiotherapy, radiation dermatitis occurs in almost all patients. Most patients have a difficult time while undergoing treatment, and therefore, when choosing a radiotherapy treatment method, minimizing radiation dermatitis is an important consideration.

Measurement of Age-Related Changes in Bone Matrix Using 2H2O Labeling

  • Lee, Jeong-Ae;Kim, Yoo-Kyeong
    • Preventive Nutrition and Food Science
    • /
    • 제10권1호
    • /
    • pp.40-45
    • /
    • 2005
  • Age-related changes in bone metabolism are well established by biochemical markers of bone matrix in serum and urine, but analysis of the residual bone matrix, which is still turning over, has not been investigated. In the present study, we measured in vivo rates of bone protein synthesis using a precursor-product method based on the exchange of ²H from ²H₂O into amino acids. Four percent ²H₂O was administered to mice in drinking water after intraperitonial (i.p) bolus injection of 99.9% ²H₂O. Mice were divided into the two groups: growing young mice were administered 4% ²H₂O for 12 weeks after an i.p bolus injection at 5 week of age, whereas weight stable adult mice started drinking 4% ²H₂O 8 weeks later than the growing group and continued 4% ²H₂O drinking for 8 weeks. Mass isotopomer abundance in alanine from bone protein was analyzed by gas chromatography/mass spectrometry. Body ²H₂O enrichments were in the range of 1.88-2.41% over the labeling period. The fractional synthesis rates (ks) of bone protein were 2.000±0.071%/d for growing mice and 0.243±0.014%/d for adult mice. These results demonstrate that the bone protein synthesis rate decreases with age and present direct evidence of age-related changes in bone protein synthesis.

냉간단조용 금형의 변형모드에 따른 탄성변형량의 측정 및 유한요소 해석 (Measurement and FEM Analysis of Elastic Deformation According to the Forging Stages in Cold Forging Die)

  • 이대근;이영선;이정환
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.112-116
    • /
    • 2002
  • In cold forging, the elastic behavior of the die has a direct influence on the accuracy of the forging part. And the die dimension is continuously changed during the loading, unloading, and ejecting stage. In this paper, we evaluated the elastic deflections of cold forging die during loading, unloading, and ejecting stage. Uni-axial strain gauges are used to measure elastic strain of die during each forging stage. Strain gauges are attached on the surface of die. A commercial F.E.M code, DEFORM-2D$\^$TM/ is used to predict elastic strain of die. Two method of F.E.M. analysis are used to compare with measured and calculated elastic strain. One is to regard the die as rigid body over forging cycle. And then, the die sass is analyzed by loading the die with pressure from the forging part. The other is to regard the die as elastic body from forging cycle. The elastic strain of die is calculated and the die is elastically deformed at each strop. The calculated results under the elastic die assumption are well agreed with experimental data using strain gauges.

  • PDF

만성폐질환 환자의 호흡곤란 설명모형 (An Explanatory Model of Dyspnea in Patients with Chronic Lung Disease)

  • 방소연
    • 기본간호학회지
    • /
    • 제17권1호
    • /
    • pp.45-54
    • /
    • 2010
  • Purpose: The purpose of this study was to develop and test an explanatory model of dyspnea in patients with chronic lung disease (CLD). Methods: Participants were 181 patients with CLD, recruited from the outpatient pulmonary clinic of one university hospital in Korea. Data were collected using questionnaires, as well as measurement of 6-minute walking distance (6MWD), oxygen saturation ($SpO_2$), FEV1% predicted, and Body Mass Index (BMI). Results: The results indicated a good fit between the proposed dyspnea model and the collected data [$x^2$=91.27, p= .13, $x^2$/d.f.=1.17, Normal Fit Index= .934]. Oxygenation ($SpO_2$, = -.530), self-efficacy (= -.429), anxiety (= .253), depression (= .224), exercise endurance (6MWD, = -.211), and pulmonary function (FEV1% predicted, = -.178) had a direct effect on dyspnea (all p< .05) and these variables explained 74% of variance in dyspnea. BMI, smoking history, and social support had an indirect effect on dyspnea. Conclusion: The findings of this study suggest that comprehensive nursing interventions should focus on recovery of respiratory health and improvement of emotions, exercise ability, and nutritional status. From this perspective, pulmonary rehabilitation would be an effective strategy for managing dyspnea in patients with CLD.

시공단계의 진동레벨 단위적용에 관한 사례 연구 (A Case Study on the Application of Vibration Level Units in the Construction Phase)

  • 최형빈;김동연
    • 화약ㆍ발파
    • /
    • 제30권2호
    • /
    • pp.86-97
    • /
    • 2012
  • 건설현장의 노천발파로 발생되는 지반진동은 인체의 간접피해 및 구조물의 물적 피해를 동반하며, 인체는 진동레벨, 구조물은 진동속도 단위로 평가한다. 본 연구는 실시단계 진동기준 중 진동속도 외 누락된 진동레벨 단위를 추가, 진동속도 및 진동레벨을 동시 측정한 적용사례로서 추후 민원이 예상되는 현장관리에 도움이 될 것으로 여겨진다. 발파진동 및 진동레벨 추정식 도출을 위한 표본수는 총 232개가 사용되었으며, 진동속도 0.3 cm/s와 진동레벨 75 dB(V) 기준의 지발당장약량을 비교한 결과, 후자가 20.0~40.9% 여유가 있음을 입증하여 진동레벨 단위척도 추가는 전혀 문제되지 않음을 언급하였다. 소음 진동 관리법이 우선된다면 노천발파 시공비용은 훨씬 저감될 것으로 생각된다. 본 연구에서 사용된 계측기기는 국내에서 처음으로 진동속도 및 진동레벨을 동시 측정할 수 있는 특성을 지닌 SV-1모델을 사용하였다.