• Title/Summary/Keyword: 2D Marker

Search Result 506, Processing Time 0.033 seconds

Microscopic Feature, Protein Marker Expression, and Osteoinductivity of Human Demineralized Dentin Matrix

  • Park, Sung-Min;Hwang, Jung-Kook;Kim, Young-Kyun;Um, In-Woong;Lee, Geun-Ho;Kim, Kyung-Wook
    • Journal of Korean Dental Science
    • /
    • v.5 no.2
    • /
    • pp.77-87
    • /
    • 2012
  • Purpose: This study examined the scanning electron microscopic feature, protein marker expression and osteoinductive activity of demineralized dentin matrix (DDM) from human for nude mice. Materials and Methods: Twenty healthy nude mice, weighing about 20 g were used for study. DDM from Human was prepared and implanted into the dorsal portion of nude mouse. Before implantation, DDM was examined by scanning electron microscopy (SEM). Nude mice were sacrificed at 2 weeks, 4 weeks and 8 weeks after DDM grafting and evaluated histologically by H-E, MT staining. And also immunohistochemistry analysis (ostecalcin, osteopontin) was performed. Result: Dentinal tubules and collagen fibers were observed by SEM of dentin surface of DDM. The DDM induced bone and cartilage independently in soft tissues. And, the histological findings showed bone forming cells like osteoblasts, fibroblasts at 2, 4 and 8 weeks. On immunohistochemistry analysis, osteocalcin and osteopontin positive bone forming cells were observed. Conclusion: This results showed that the DDM from human has osteoinductive ability and is a good alternative to autogenous bone graft materials.

Stereo vision mixed reality system using the multi-blob marker (다중 블럽 마커를 이용한 스테레오 비전 혼합현실 시스템의 구현)

  • 양기선;김한성;손광훈
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.1907-1910
    • /
    • 2003
  • This paper describes a method of stereo image composition for mixed reality without camera calibration or complicate tracking algorithm. The proposed system tracks the panel which has blob makers, and composes virtual objects naturally using the method of texture mapping which is often used in geological computer graphics mapping when we do mapping 2D computer graphic data or man-made 2D images. The proposed algorithm makes it possible for us to compose virtual data even in the case that the panel is bent. For composing 3D object, the system uses depth information obtained from stereo image so that we do not need cumbersome procedure of camera calibration.

  • PDF

Antitumor effects of ophiopogonin D on oral squamous cell carcinoma

  • Nguyen Thi Kieu Trang;Vu Phuong Dong;Hoon Yoo
    • International Journal of Oral Biology
    • /
    • v.49 no.2
    • /
    • pp.42-47
    • /
    • 2024
  • Ophiopogonin D (OPD) is a steroidal glycoside derived from Ophiopogon japonicus, a traditional Chinese medicine with diverse biological activities, including antithrombosis, anti-inflammation, and antitussive effects. To investigate the cellular effects and mechanisms of OPD on oral squamous cell carcinoma, cell viability was explored, and the effects of OPD on cell cycle regulators, apoptotic marker proteins, and key proteins involved in metastasis and signaling pathways were examined by MTT assay and Western blotting in YD38 cells. OPD strongly inhibited cell proliferation and induced caspase-dependent apoptosis of YD38 cells by suppressing the cell cycle and activating caspase-3 and poly ADP ribose polymerase. Additionally, OPD suppressed the expression of vital proteins regulating metastasis and proliferation within the integrin/matrix metalloproteinases/FAK and AKT/PI3K/mTor pathways. Thus, OPD can be a potential treatment candidate for gingival cancer.

Effects of intrauterine growth restriction during late pregnancy on the cell growth, proliferation, and differentiation in ovine fetal thymuses

  • Zi, Yang;Ma, Chi;He, Shan;Yang, Huan;Zhang, Min;Gao, Feng;Liu, Yingchun
    • Animal Bioscience
    • /
    • v.35 no.7
    • /
    • pp.989-998
    • /
    • 2022
  • Objective: This study investigated the effects of intrauterine growth restriction (IUGR) during late pregnancy on the cell growth, proliferation, and differentiation in ovine fetal thymuses. Methods: Eighteen time-mated Mongolian ewes with singleton fetuses were allocated to three groups at d 90 of pregnancy: restricted group 1 (RG1, 0.18 MJ ME/body weight [BW]0.75/d, n = 6), restricted group 2 (RG2, 0.33 MJ ME/BW0.75/d, n = 6) and control group (CG, ad libitum, 0.67 MJ ME/BW0.75/d, n = 6). Fetuses were recovered at slaughter on d 140. Results: The G0/G1 phase cell number in fetal thymus of the RG1 group was increased but the proliferation index and the expression of proliferating cell nuclear antigen (PCNA) were reduced compared with the CG group (p<0.05). Fetuses in the RG1 group exhibited decreased growth hormone receptor (GHR), insulin-like growth factor 2 receptor (IGF-2R), and their mRNA expressions (p<0.05). For the RG2 fetuses, there were no differences in the proliferation index and PCNA expression (p>0.05), but growth hormone (GH) and the mRNA expression of GHR were lower than those of the CG group (p<0.05). The thymic mRNA expressions of cyclin-dependent protein kinases (CDKs including CDK1, CDK2, and CDK4), CCNE, E2-factors (E2F1, E2F2, and E2F5) were reduced in the RG1 and RG2 groups (p<0.05), and decreased mRNA expressions of E2F4, CCNA, CCNB, and CCND were occurred in the RG1 fetuses (p<0.05). The decreased E-cadherin (E-cad) as a marker for epithelial-mesenchymal transition (EMT) was found in the RG1 and RG2 groups (p<0.05), but the OB-cadherin which is a marker for activated fibroblasts was increased in fetal thymus of the RG1 group (p<0.05). Conclusion: These results indicate that weakened GH/IGF signaling system repressed the cell cycle progression in G0/G1 phase in IUGR fetal thymus, but the switch from reduced E-cad to increased OB-cadherin suggests that transdifferentiation process of EMT associated with fibrogenesis was strengthened. The impaired cell growth, retarded proliferation and modified differentiation were responsible for impaired maturation of IUGR fetal thymus.

Evaluation of usefulness for Stereotactic Partial Breast Irradiation(S-PBI) by using Surface Fiducial Marker (표면위치표지자를 적용한 정위적 부분유방방사선치료의 유용성 평가)

  • Kim, JongYeol;Jung, DongMin;Kim, SeYoung;Yoo, HyunJong;Choi, JungHoan;Park, HyoKuk;Baek, JongGeol;Lee, SangKyu;Cho, JeongHee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.99-108
    • /
    • 2021
  • Purpose: The goal of this study is to evaluate usefulness of noninvasive method instead of previous inserting Fiducial Marker Method when performing Stereotactic Partial Breast Irradiation in CyberKnife. Material and methods: For consistency of Imaging Center, we evaluated both oblique images at angle 45 and 315 acquired from 2D Simulator and CyberKnife quantitatively through dice similarity coefficient. Also, location reproducibility of Surface Fiducial Marker was analyzed from 2D Simulator, treatment plans and CyberKinfe images by using 8 Fiducial Markers made of gold attached to ATOM Phantom based on our institution's protocols. Results: The results of the estimated consistency were 0.87 and 0.9 at the oblique angle 45 and 315, respectively. For location consistency of Surface Fiducial Markers, values of horizontal vertical direction of left breast were Superior/Inferior 0.3 mm, Left/Right -0.3 mm, Anterior/Posterior 0.4 mm, and the values of rotational direction were Roll 0.3 °, Pitch 0.2 °, Yaw 0.4 °. The values of horizontal vertical direction of right breast were Superior/Inferior -0.1 mm, Left/Right -0.1 mm, Anterior/Posterior -0.1 mm, and the values of rotational direction were Roll 0.2°, Pitch 0.1°, Yaw 0.1°. Conclusions: We expect that the protocols used by Surface Fiducial Markers when performing Stereotactic Partial Breast Irradiation in CyberKnife will provide protection from pain and cut expenses for treatment and reduce treatment errors and make treatment more accurate by suggesting treatment protocols based on high consistency of Imaging Center and reproducibility of Fiducial Markers.

Analysis of Overall Setup Accuracy Using On-Board Imager�� (온-보드 영상장치를 이용한 총체적 셋업의 정확성 분석)

  • Ma, Sun-Young;Lim, Sang-Wook;Kang, Soo-Man;Jeung, Tae-Sig
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.67-71
    • /
    • 2011
  • We evaluated the overall setup accuracy for the On-Board Imager (OBI, Varian Medical Systems Inc., Palo Alto, CA, USA), with attention to the laser, the gantry, and operator performance. We let experienced technicians place the marker block on the couch using a lock bar system, with alignment to the isocenter of the laser, every morning. A pair of radiographic images of the marker block was acquired at $0^{\circ}$ and $270^{\circ}$ angles to the kV arm to correct the position using a 2D/2D matching technique. Once the desired match was achieved, the couch was moved remotely to correct the setup error and the parameters were saved. The average for the vertical and the longitudinal displacements were 0.65 mm and 0.66 mm, and 0.01 mm for the lateral displacement. The average for the vertical and longitudinal displacements were statistically significant at the 0.05 level (p value=0.000 for both), while the p value for the lateral direction was 0.829. These results show that the tendencies to displacement in vertical and longitudinal directions occur through systematic error, while systematic error was not found in the lateral displacement. This daily overall evaluation is practical and easy to find the systematic and random errors in the setup system; however, a daily QA for laser and OBI alignment is still needed to minimize the systematic error in aligning patients.

A Study of the Relationships between the Ratio of $2^{nd}$ to $4^{th}$ Digit Length and Cerebral Laterality (제2수지-제4수지 길이 비율과 대뇌 편측화 관계 연구)

  • Kim, Ah-Young;Kim, Seong-Kyun;Youn, Jin-Young;Jeong, Jae-Seung;Lee, Joo-Ho;Chae, Jeong-Ho;Lee, Yu-Sang
    • Korean Journal of Biological Psychiatry
    • /
    • v.18 no.1
    • /
    • pp.25-35
    • /
    • 2011
  • Objectives : Cerebral laterality is thought to be an important marker for neurodevelopment. Prenatal testosterone could influence both cerebral laterality and 2nd to 4th finger length ratio(2D : 4D). EEG coherence and 2D : 4D were examined to investigate the relationship between prenatal testosterone level and cerebral laterality. Methods : EEG was recorded in 24 healthy subjects in the eyes closed resting state. Differences in 2D : 4D finger ratio were used to discriminate "masculine finger type" and "feminine finger type" groups. The 2D : 4D ratio was lower and greater than one for the "masculine finger type" group and "feminine finger type" group, respectively. We used coherence analysis to estimate the cortical functional connectivity. Results : There were statistically meaningful relationships among cerebral functional connectivity, sex and finger ratio. Man and masculine finger type group showed higher intra-hemispheric coherence than those of woman and feminine finger type group. Woman and feminine finger type group showed higher inter-hemispheric coherence than those of man and masculine finger type group. Conclusions : These results imply that prenatal testosterone might act as important determinants of cerebral laterality. Further examination of the relationship between 2D : 4D and EEG coherence in schizophrenia could give some clues for the neurodevelopmental hypothesis of schizophrenia genesis.

HPLC-tandem Mass Spectrometric Analysis of the Marker Compounds in Forsythiae Fructus and Multivariate Analysis

  • Cho, Hwang-Eui;Ahn, Su-Youn;Son, In-Seop;Hwang, Gyung-Hwa;Kim, Sun-Chun;Woo, Mi-Hee;Lee, Seung-Ho;Son, Jong-Keun;Hong, Jin-Tae;Moon, Dong-Cheul
    • Natural Product Sciences
    • /
    • v.17 no.2
    • /
    • pp.147-159
    • /
    • 2011
  • A high-performance liquid chromatography-electrospray ionization-tandem mass spectrometric method was developed to determine simultaneously eight marker constituents of Forsythiae fructus, and subsequently applied it to classify its two botanical origins. The marker compounds of Forsythia suspensa were phillyrin, pinoresinol, phillygenin, lariciresinol and forsythiaside; those of F.viridissima were arctiin, arctigenin and matairesinol. Separation of the eight analytes was achieved on a phenyl-hexyl column (150${\times}$2.0 mm i.d., 3 ${\mu}M$) using gradient elution with the mobile phase: (A) 10% acetonitrile in 0.5% acetic acid, (B) 40% aqueous acetonitrile. A few fragment ions specific to the types of lignans, among the product ions generated by collisonally induced dissociation (CID) of molecular ion clusters, such as [M-H]$^-$ or [M+OAc]$^-$ were used not only for fingerprinting analysis but for the quantification of each epimer by using multiple-reaction monitoring mode. It was shown good linearity ($r^2{\geq}$ 0.9998) over the wide range of all analytes; intra- and inter-day precisions (RSD, %) were within 9.14% and the accuracy ranged from 84.3 to 115.1%. The analytical results of 40 drug samples, combined with multivariate statistical analyses - principal component analysis (PCA) and hierarchical cluster analysis (HCA) - clearly demonstrated the classification of the test samples according to their botanical origins. This method would provide a practical strategy for assessing the authenticity or quality of the herbal drug.

Diagnostic value of eosinopenia and neutrophil to lymphocyte ratio on early onset neonatal sepsis

  • Wilar, Rocky
    • Clinical and Experimental Pediatrics
    • /
    • v.62 no.6
    • /
    • pp.217-223
    • /
    • 2019
  • Purpose: To determine the diagnostic value of eosinopenia and the neutrophil-to-lymphocyte ratio (NLR) in the diagnosis of early onset neonatal sepsis (EONS). Methods: This cross-sectional study was conducted in the Neonatology Ward of R.D. Kandou General Hospital Manado between July and October 2017. Samples were obtained from all neonates meeting the inclusion criteria for EONS. Data were encoded using logistic regression analysis, the point-biserial correlation coefficient, chi-square test, and receiver operating characteristic curve analysis, with a P value <0.05 considered significant. Results: Of 120 neonates who met the inclusion criteria, 73 (60.8%) were males and 47 (39.2%) were females. Ninety (75%) were included in the sepsis group and 30 (25%) in the nonsepsis group. The mean eosinophil count in EONS and non-EONS groups was $169.8{\pm}197.1cells/mm^3$ and $405.7{\pm}288.9cells/mm^3$, respectively, with statistically significant difference (P<0.001). The diagnostic value of eosinopenia in the EONS group (cutoff point: $140cells/mm^3$) showed 60.0% sensitivity and 90.0% specificity. The mean NLR in EONS and non-EONS groups was $2.82{\pm}2.29$ and $0.82{\pm}0.32$, respectively, with statistically significant difference (P<0.001). The diagnostic value of NLR in the EONS group (cutoff point, 1.24) showed 83.3% sensitivity and 93.3% specificity. Conclusion: Eosinopenia has high specificity as a diagnostic marker for EONS and an increased NLR has high sensitivity and specificity as a diagnostic marker for EONS.

Proteomic identification of the bovine pregnancy associated proteins by peptide mass fingerprinting

  • Kang, Sun-Chul;Kim, Eun-Jung;Pyo, Jae-Hoon;Lim, Jin-Kyu
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.558-561
    • /
    • 2002
  • In this study, a method for the localization of pregnancy-specific proteins from cow urine on 2-D gel have been established. The proteins were digested with trypsin in gel and then analyzed with MALDI- TOF or transferred to a membrane and microsequenced. To examine the pregnancy associated protein spot 2 as a diagnosis marker in bovine urine 2-D western blotting was performed. This antibody was reacted specifically in the protein of pregnant cow’s urine. Consequently spot 2 was identified and found to be good candidates for developing cow pregnancy detection assay kit.

  • PDF