• Title/Summary/Keyword: 2D ISI

Search Result 61, Processing Time 0.024 seconds

A Realization of the Synchronization Module between the Up-Link and the Down-Link for the WiBro System (WiBro 시스템에서 상향링크와 하향링크 간 시간 동기 장치 구현)

  • Park Hyong-Rock;Kim Jae-Hyung;Hong Een-Kee
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.4 no.1
    • /
    • pp.7-13
    • /
    • 2005
  • In this paper, we propose the time synchronization module on fiber optic repeater to use optic line delay for obtaining time synchronization between up-link and down-link, in the 2.3 GHz WiBro network using TDD/OFDM (Time Division Duplex/Orthogonal Frequency Division Multiplexing) Generally, when we use fiber optic repeater to remove the shade area, it occurs transmission delay which is caused by optic transmission between RAS (Radio Access Station) and fiber optic repeater and inner delay of fiber optic repeater. Because the WiBro system is adopting a TOO method and there exists the difference of switching time which is caused by these delay between up-link and down-link, it occurs ISI (Inter Symbol Interference), ICI (Inter Carrier Interference). These interference results in the reduction of the coverage. And the inconsistency between Up-Link and Down-Link switching time maybe gives rise to the interruption of communication. In order to prevent these cases, we propose synchronization module using analog optic line delay as the one of synchronizing up-link and down-link. And we propose the consideration factor for the designing time synchronization module and the feature of optic line of analog method. The measurement result of optic line time synchronization module of structure proposed is as follows, the delay error of $0.5{\mu}g$ and the insertion loss value below maximum 4.5dB in range of $0{\sim}40{\mu}s$. These results fully meet the specification of WiBro System.

  • PDF

A Case Report of a Patient with Insomnia Related To Fibromyalgia Treated with Korean Medicine, including Bunshimgi-eum (분심기음을 포함한 한방치료로 호전된 섬유근육통 환자의 불면 치험 1례)

  • Joo-hee Oh;Seung-hee Lee;Hyun-jin Lee;Dong-jin Jang;Yoon-jung Lee;Jeong-hee Noh;Ju-yeon Shin;Mu-jin Park;Woo-sub Song
    • The Journal of Internal Korean Medicine
    • /
    • v.45 no.2
    • /
    • pp.131-139
    • /
    • 2024
  • In this case report, we describe the effects of Korean Medicine therapies, including Bunshimgi-eum, on a patient hospitalized with insomnia due to fibromyalgia in a Korean Medicine Hospital. We treated the patient with Bunshimgi-eum for 21 of 27 hospital days. Post-treatment, we used the Insomnia Severity Index (ISI) to measure the severity of insomnia. To determine the severity of multiple pain, including neck, low back, Lt. shoulder, Lt. elbow, Rt. knee, and hand, we used the Numerical Rating Scale (NRS). For evaluation of generic health status, we used the European Quality of Life-5 Dimensions (EQ-5D) scale. After the treatment, the patient's clinical symptoms improved, according to the ISI, NRS, and EQ-5D. The results of this case study suggest that Korean Medicine therapies, including Bunshimgi-eum, may have positive effects as a treatment for insomnia related to fibromyalgia.

Measurement of Peak-to-Average Power Ratio for HRIT

  • Park Durk-Jong;Yang Hyung-Mo;Ahn Sang-Il
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.498-500
    • /
    • 2004
  • QPSK (Quaternary Phase Shift Keying) will be adopted as the modulation of HRIT (High Rate Information Transmission) which is transmitted to COMS (Communication, Ocean and Meteorological Satellite) through HPA (High Power Amplifier) in ground segment. Due to the nonlinearity of HPA, IMD (Inter-Modulation Distortion) of multi-carrier signals and PAPR (Peak-to-Average Power Ratio) of modulated HRIT must be considered to estimate the output power of HPA. In this paper, we measured the PAPR to various the roll-off factor of RRC (Root Raised Cosine filter) which is filtering the modulated HRIT signal for reducing ISI (Inter-Symbol Interference) and bandwidth. It was found that the minimum PAPR is 2.78dB at 0.5 of roll-off factor for scrambled data. It's 2.78dB of P APR will be in output power selecting in COMS earth station.

  • PDF

Correlation between Instrument on Pattern Identification for Depression and Psychological Tests by Statistical Analysis (통계적 분석을 통한 우울증 변증도구와 심리검사의 상관성 연구)

  • Kim, Hwan;Lee, Hun-Soo;Lee, Eun Jung;Park, Joon-Ho;Kang, Wee-Chang;Jung, In Chul
    • Journal of Oriental Neuropsychiatry
    • /
    • v.27 no.3
    • /
    • pp.131-146
    • /
    • 2016
  • Objectives: This study was performed to determine the correlation between Instrument on Pattern Identification for Depression and Psychological tests by Pearson Correlation Coefficient and Regression analysis.Methods: Two assessors carried out the evaluation using the instrument on pattern identification for depression. They also performed the following psychological tests: Beck Depression Inventory (BDI), State-Trait Anxiety Inventory (STAI), State-Trait Anger Expression Inventory (STAXI), the Temperament and Character Inventory (TCI), Insomnia Severity Index (ISI_Total), Self-disclosure Inventory, subjective well-being Inventory, Health perception Inventory, and Personality Assessment Inventory (PAI). A total of 167 participants who got HAM-D score over 12 were targeted for the evaluation. Our research team carried out Pearson correlation coefficient analyses and regression analysis between pattern identification for depression and Psychological tests. We listed the results by descending order and interpreted the results.Results: Pearson correlation analysis revealed the following results: 1) Stagnation of Liver Gi was associated with BDI (0.60) and STAI (0.55); 2) Dual Deficiency of the Heart and Spleen was associated with BDI (0.60), ISI_Total (0.52), and STAI (0.42); 3) Relieving stagnation of Phlegm-Gi was associated with BDI (0.65), STAI (0.54), and Subjective well-being inventory (−0.52); 4) Gi-deficiency Mingled with sputum was associated with BDI (0.50), ISI_Total (0.40), and STAI (0.395); 5) Stagnant Gi transforming into fire was associated with BDI (0.56), STAI_TR (0.51), and Health perception Inventory (−0.458); 6) Yin-Deficiency with Effulgent Fire was associated with BDI (0.55), ISI_total (0.54), and STAI (0.41).Conclusions: Through correlation analysis between Instrument on Pattern Identification for Depression and Psychological tests, we could suggest a System for Oriental Medical Diagnosis for Depression.

Application of an Iterative 2D Equalizer to Holographic Data Storage Systems (반복 2차 등화기의 홀로그래픽 데이터 저장 장치 적용)

  • Kim, Sun-Ho;Im, Sung-Bin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.7
    • /
    • pp.1-5
    • /
    • 2012
  • At the present time when the limits of the magnetic storage systems appear, the holographic data storage (HDS) devices with high data transfer rate and high recording density are emerging as attractive candidates for next-generation optical storage devices. In this paper, to effectively improve the detection performance that is degraded by the two-dimensional inter-symbol interference under the HDS channel environment and the pixel misalignment, an iterative two-dimensional equalization scheme is proposed based on the contraction mapping theorem. In order to evaluate the performance of the proposed scheme, for various holographic channel environments we measure the BER performance using computer simulation and compare the proposed one with the conventional threshold detection scheme, which verifies the superiority of the proposed scheme.

A 2.0-GS/s 5-b Current Mode ADC-Based Receiver with Embedded Channel Equalizer (채널 등화기를 내장한 2.0GS/s 5비트 전류 모드 ADC 기반 수신기)

  • Moon, Jong-Ho;Jung, Woo-Chul;Kim, Jin-Tae;Kwon, Kee-Won;Jun, Young-Hyun;Chun, Jung-Hoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.12
    • /
    • pp.184-193
    • /
    • 2012
  • In this paper, a 5-bit 2-GS/s 2-way time interleaved pipeline ADC for high-speed serial link receiver is demonstrated. Implemented as a current-mode amplifier, the stage ADC simultaneously processes the tracking and residue amplification to achieve higher sampling rate. In addition, each stage incorporates a built-in 1-tap FIR equalizer, reducing inter-symbol-interference (ISI)without an extra digital post-processing. The ADC is designed in a 110nm CMOS technology. It comsumes 91mW from a 1.2-V supply. The area excluding the memory block is $0.58{\times}0.42mm^2$. Simulation results show that when equalizer is enabled, the ADC achieves SNDR of 25.2dB and ENOB of 3.9bits at 2.0GS/s sample rate for a Nyquist input signal. When the equalizer is disengaged, SNDR is 26.0dB for 20MHz-1.0GHz input signal, and the ENOB of 4.0bits.

An Iterative Two-Dimensional Equalizer for Bit Patterned Media Storage Systems Based on Contraction Mapping (비트 패턴 미디어 저장장치를 위한 축약사상 기반의 반복적 2차원 등화기)

  • Moon, Woosik;Im, Sungbin;Park, Sehwang
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.3-8
    • /
    • 2013
  • Bit patterned media (BPM) storage is one of the promising technologies to overcome the limitations of the conventional magnetic recording. However, there are some problems in a high areal density BPM storage, inter-track interference, inter-symbol interference and noise which are severely degrading performance of the system with reducing the bit error rate. In this paper, we present a simple iterative two-dimensional equalizer based on the contraction mapping theorem to mitigate these adverse effects. Furthermore, we examine that the channel characteristics of the proposed two-dimensional equalizer satisfies the convergence conditions. In the simulation we demonstrate the bit separation characteristics of the one-dimensional equalizer and the two-dimensional equalizer and evaluate the BER performance of the proposed equalizer comparing with the conventional equalizers. According to the results of experiments, the proposed equalizer is an promising equalizer with maintaining proper complexity for a high areal density BPM storage.

Design and Performance Evaluation of Equalizer for the S-DMT Cable Modem (S-DMT 케이블 모뎀의 등화기 설계 및 성능평가)

  • Cho, Byung-Hak
    • Journal of Digital Contents Society
    • /
    • v.7 no.2
    • /
    • pp.109-115
    • /
    • 2006
  • In this paper, we design and performance evaluate the equalizer for S-DMT table modem, which supports more channels and better quality symmetric mutimedia services over HFC network. We verified that both of the designed equalizers show good convergence characteristics and that the performance of the time domain equalizer is 1 dB better than that of the frequency domain equalizer overall range of Eb/No.

  • PDF

Performance of 4-level Modulation Code for Holographic Data Storage (홀로그래픽 데이터 저장장치를 위한 4-레벨 변조 부호의 성능 비교)

  • Park, Keunhwan;Lee, Jaejin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.9
    • /
    • pp.1672-1677
    • /
    • 2015
  • The multi-level holographic storage system can store more than one bit per pixel. In this paper, we introduce a 6-pixel 4-level modulation code and compare with 4-level 6/9 modulation code and 2/3 modulation code. The proposed 6-pixel modulation code has the minimum Euclidean distance 3. The 6-pixel modulation code is approximately 1dB better than the other modulation codes.

Two-Dimensional 8/9 Error Correcting Modulation Code

  • Lee, Kyoungoh;Kim, Byungsun;Lee, Jaejin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.5
    • /
    • pp.215-219
    • /
    • 2014
  • In holographic data storage (HDS), a high transmission rate is accomplished through the use of a charge coupled device array for reading two-dimensional (2D) pixel image data. Although HDS has many advantages in terms of storage capacity and data transmission rates, it also features problems, such as 2D intersymbol interference (ISI) by neighboring pixels and interpage interference (IPI) by multiple images stored in the same holographic volume. Modulation codes can be used to remove these problems. We introduce a 2D 8/9 error-correcting modulation code. The proposed modulation code exploits the trellis-coded modulation scheme, and the code rate is larger (about 0.889) than that of the conventional 6/8 balanced modulation code (an increase of approximately 13.9%). The performance of the bit error rate (BER) with the proposed scheme was improved compared with that of the 6/8 balanced modulation code and the simple 8/9 code without the trellis scheme.