• Title/Summary/Keyword: 2D 영상

Search Result 3,281, Processing Time 0.039 seconds

Interactive 3D Stereoscopic Image Editing System using Image-based modeling (영상 기반 모델링 기법을 이용한 대화식 3차원 입체 영상 저작 시스템)

  • Yun, Chang-Ok;Yun, Tae-Soo;Lee, Dong-Hoon
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.10 no.2
    • /
    • pp.53-66
    • /
    • 2006
  • Recent technique has shown high interest in 3D stereoscopic image, one out of high immersion appearance techniques. Unlike general 2D image, 3D stereoscopic image is generated by 3D geometric information. Therefore, the lack of 3D geometric information sometimes imposes restrictions or makes editing more tedious. We propose a new unsupervised technique aimed to generate stereoscopic image which is estimated by depth-map information using image-based modeling from a single input image. The proposed system is implemented as the Adobe Photoshop(R) plug-in for considering generality and expandability, and also supports a preview function of interactive 3D stereoscopic image to determine stereoscopic view of high quality.

  • PDF

A Study on the space analysis algorithm for 3D TV image conversion (TV영상의 3차원 변환을 위한 공간분석 알고리즘에 관한 연구)

  • 신강호;김계국
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.4
    • /
    • pp.121-126
    • /
    • 2002
  • The stereoscopic image is that we can see it closer than a real thing compared to 2D image, and it has influence on human's vision information because it is more natural method to feel connections between the spaces of the image and himself. There are several method convert from 2d image to 3d image. But, in this paper, we are propose the image separate algorithm of continuous input system through a spatial analysis, not be done with 2D still image. Additionally, we will adapt to the moving vector which has been used in MPEG. In this experiment, we obtained the effect of 3D image.

  • PDF

Viewers' Psychophysiological and Self-report Responses to 3D Stereoscopic Display (3D 영상의 입체성이 콘텐츠 특성에 따라 이용자의 심리적 반응에 미치는 효과 - 콘텐츠의 유인가와 각성도를 중심으로 -)

  • Lim, So-Hei;Chung, Ji-In
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.6
    • /
    • pp.211-222
    • /
    • 2012
  • There has been growing academic interest in revealing the effect of 3D stereoscopic displays, mostly based on the assumption that 3D would enhance the media user's psychological experiences. A 2(Display: 2D, 3D) x 2(Arousal: High, Low) x2(Valence: Positive, Negative) within-between subject experimental design, including both psychophysiological and self-report measurements, was employed to investigate if valence and arousal of the media content interact with the 3D stereo display. The results confirmed that 3D stereo significantly enhances the viewer's skin conductance level, while no meaningful difference for HR was found across the experimental conditions. The viewer's recall memory did not differ depending on the display type either. However, the viewer experienced a greater level of presence and liking of the content when the negative content was displayed in 3D stereo in comparison with the positive content. The practical implications of the results are further discussed.

2D/3D Video Conversion Method using Differential Depth Information by Grouped Object (그룹화된 객체별 깊이정보를 차등 적용한 2D/3D 동영상 변환 기법)

  • Han, Sung-Ho;Hong, Yeong-Pyo;Lee, Jong-Yong;Lee, Sang-Hun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12b
    • /
    • pp.445-448
    • /
    • 2011
  • 본 논문은 그룹화된 객체별 깊이정보를 차등 적용한 2D/3D 동영상 변환 기법에 관한 연구이다. 기존의 연구에서는 프레임의 움직임 정보와 기하학적 깊이 단서를 이용해 깊이정보를 추출하여 2D/3D 동영상 변환을 한다. 그러나 영상의 움직임 정보를 획득할 수 없는 영역의 경우 정확한 깊이정보를 얻을 수 없어 해당 영역의 3D 효과를 얻을 수 없는 문제점이 있다. 제안하는 기법에서는 객체 및 배경을 추출하고 움직임 정보와 기하학적 단서를 이용한 깊이정보를 그룹화된 객체별 차등 적용하여 움직임 정보가 없는 영역에서도 3D 효과를 얻을 수 있는 방법을 제안한다. 최종적으로 원본 영상과 생성된 깊이맵을 DIBR(Depth Image Based Rendering) 과정을 통해 3D 동영상을 생성한 결과 움직임 정보가 없는 영역에서도 3D 효과를 얻을 수 있었다.

  • PDF

A Method of Stereoscopic 3D Image Quality Assessment (스테레오스코픽 3D영상 화질 평가 방법)

  • Park, Young-Soo;Hur, Nam-Ho;Pyo, Kyung-Soo;Song, Chung-Kun
    • Journal of Broadcast Engineering
    • /
    • v.16 no.2
    • /
    • pp.319-330
    • /
    • 2011
  • For objective assessment of stereoscopic 3D image quality, we measure quality of left and right image with 2D image quality measurement method. However, this method is inconvenient because that we have to measure quality of left and right image individually. Therefore we propose a method of stereoscopic 3D image quality assessment using one overlaid image with left and right image. Using this method, One can measure quality of stereoscopic 3D image more easily and quickly.

2D/3D conversion method using depth map based on haze and relative height cue (실안개와 상대적 높이 단서 기반의 깊이 지도를 이용한 2D/3D 변환 기법)

  • Han, Sung-Ho;Kim, Yo-Sup;Lee, Jong-Yong;Lee, Sang-Hun
    • Journal of Digital Convergence
    • /
    • v.10 no.9
    • /
    • pp.351-356
    • /
    • 2012
  • This paper presents the 2D/3D conversion technique using depth map which is generated based on the haze and relative height cue. In cases that only the conventional haze information is used, errors in image without haze could be generated. To reduce this kind of errors, a new approach is proposed combining the haze information with depth map which is constructed based on the relative height cue. Also the gray scale image from Mean Shift Segmentation is combined with depth map of haze information to sharpen the object's contour lines, upgrading the quality of 3D image. Left and right view images are generated by DIBR(Depth Image Based Rendering) using input image and final depth map. The left and right images are used to generate red-cyan 3D image and the result is verified by measuring PSNR between the depth maps.

MMT based V3C data packetizing method (MMT 기반 V3C 데이터 패킷화 방안)

  • Moon, Hyeongjun;Kim, Yeonwoong;Park, Seonghwan;Nam, Kwijung;Kim, Kyuhyeon
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2022.06a
    • /
    • pp.836-838
    • /
    • 2022
  • 3D Point Cloud는 3D 콘텐츠를 더욱 실감 나게 표현하기 위한 데이터 포맷이다. Point Cloud 데이터는 3차원 공간상에 존재하는 데이터로 기존의 2D 영상에 비해 거대한 용량을 가지고 있다. 최근 대용량 Point Cloud의 3D 데이터를 압축하기 위해 V-PCC(Video-based Point Cloud Compression)와 같은 다양한 방법이 제시되고 있다. 따라서 Point Cloud 데이터의 원활한 전송 및 저장을 위해서는 V-PCC와 같은 압축 기술이 요구된다. V-PCC는 Point Cloud의 데이터들을 Patch로써 뜯어내고 2D에 Projection 시켜 3D의 영상을 2D 형식으로 변환하고 2D로 변환된 Point Cloud 영상을 기존의 2D 압축 코덱을 활용하여 압축하는 기술이다. 이 V-PCC로 변환된 2D 영상은 기존 2D 영상을 전송하는 방식을 활용하여 네트워크 기반 전송이 가능하다. 본 논문에서는 V-PCC 방식으로 압축한 V3C 데이터를 방송망으로 전송 및 소비하기 위해 MPEG Media Transport(MMT) Packet을 만드는 패킷화 방안을 제안한다. 또한 Server와 Client에서 주고받은 V3C(Visual Volumetric Video Coding) 데이터의 비트스트림을 비교하여 검증한다.

  • PDF

VRML을 이용하는 3 차원 융합 영상의 가시화와 위치 측정 구현 : 간질 환자의 적용 예

  • 이상호;유선국;정해조;강원석;성민모;이재훈;김새롬;김희중
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.50-50
    • /
    • 2003
  • World Wide Web (WWW)에서 Virtual Reality Modeling Language (VRML)를 이용하는 3 차원 (3D) 디스플레이는 사용자에게 직관적인 정보를 더 효과적으로 제공해 준다. 웹을 기반으로 하는 해부학적 영상과 융합되는 기능적 영상의 3D 가시화는 아직까지 체계적인 방식으로 연구가 활발히 진행되지 않았다. 이 연구의 목적은 2D 영상들과 함께 웹에서 VRML을 이용하여 구현되는 3D 해부학적 표면 영상들과 기능적 표면 영상들을 동시적으로 관찰할 수 있게 하고 VRML을 통해 만들어진 거리 측정 도구를 가지고 관심영역의 공간적인 위치 정보를 제공하는 것이다. 본 연구에서는 한 명의 간질 환자로부터 Magnetic Resonance (MR) 축면 영상과 발작기 및 발작간기 Single Photon Emission Computed Tomo graphy (SPECT) 축면 영상들을 각각 획득하였다. 발작 진원지의 확인을 향상시키기 위해서 subtraction ictal SPECT co registered to MRI (SISCOM) 을 수행하였다. SISCOM 결과로 나타난 각 2D 영상들은 모든 voxel 들의 평균 값 위로 1 표준편차와 2 표준편차에 해당하는 문턱 이상의 영상 값을 갖도록 하였다. SISCOM으로 나타나는 간질 발작 진원지들과 MRI 영상에서 회색질, 백색질 및 뇌척수액의 경계들을 각각 분할하고 marching cube 알고리즘에 의해 VRML 표면 영상들로 나타내었다. 축면 영상에서 실제 거리를 나타내는 x, y 축의 길이를 측정하고 z 축선의 길이를 계산하였다. VRML을 이용한 거리 측정 도구를 만들어 이전의 VRML 표면 영상들과 융합하였다. MRI 영상을 이용하여 3D 표면 영상들의 단면을 나타내고 3D 표면 영상들의 투명도를 설정하기 위해 Java Script 루틴을 사용자 인터페이스 도구로서 삽입하였다. 웹 페이지에서 구현되는 3D 표면 영상들의 투명도와 관찰 위치를 조절함에 따라 모델들 사이의 공간적인 정보를 직관적으로 알 수 있었다. 간질 발작 진원지에 대응하는 해부학적 구조를 3D 표면 영상들을 가로지르는 MRI 평면 영상들을 통해서 확인하였다. 결론적으로 본 연구에서 제시하는 웹에 근거한 3D 융합 영상의 가시화와 위치 측정은 진단 및 치료 방사선학과 외과학 등의 분야에서 온라인 방식의 연구와 교육에 있어 많은 도움을 줄 것이다.

  • PDF

the 3D Contents DID Image System which Holograms(Clock) (3D 홀로그램을 사용한 (시계)콘텐츠 DID 영상시스템)

  • Yang, Sung-Young;Park, Dea-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.139-142
    • /
    • 2012
  • It reflects the value of 2D contents goods. It uses, 3D when holograms DID charm of the goods, the buying power and necessary etc. DID image system are the stamp. 3D holograms and DID image systems, the screen, it plans CMS from the research which it sees and it embodies 3D hologram contents DID image systems. Also charm, also the buying power and analysis, the comparative stamp do satisfaction etc. in about 2D contents and 3D contents and 3D holograms DID.

  • PDF

Analysis of Uncertainties due to Digitally Reconstructed Radiographic (DRR) Image Quality in 2D-2D Matching between DRRs and kV X-ray Images from the On-Board Imager (OBI) (디지털 재구성 방사선영상과 온보드 영상장치를 이용한 2D-2D 정합 시 디지털 재구성 방사선영상의 질이 정합 정확도에 미치는 영향 분석)

  • Cheong Kwang-Ho;Cho Byung-Chul;Kaug Sei-Kwon;Kim Kyoung-Joo;Bae Hoon-Sik;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.67-76
    • /
    • 2006
  • We evaluated the accuracy of a patient setup error correction due to reference image quality for a 2D-2D matching process. Digitally reconstructed radiographs (DRRs) generated by use of the Pinnacle3 and the Eclipse for various regions of a humanoid phantom and a patient for different CT slice thickness were employed as a reference images and kV X-ray Images from the On-Board Imager were registered to the reference DRRs. In comparison of the DRRs and profiles, DRR image quality was getting worse with an increase of CT image slice thickness. However there were only slight differences of setup errors evaluation between matching results for good and poor reference DRRs. Although DRR image quality did not strongly affect to the 2D-2D matching accuracy, there are still potential errors for matching procedure, therefore we recommend that DRR images are needed to be generated with less than 3mm slice thickness for 2D-2D matching.

  • PDF