• Title/Summary/Keyword: 2D/3D simultaneous

Search Result 282, Processing Time 0.027 seconds

NONPOTENTIAL PARAMETERS OF SOLAR ACTIVE REGION AR 5747

  • MOON Y.-J.;YUN H. S.;CHOE GWANGSON;PARK Y. D.;MICKEY D. L.
    • Journal of The Korean Astronomical Society
    • /
    • v.33 no.1
    • /
    • pp.47-55
    • /
    • 2000
  • Nonpotential characteristics of magnetic fields in AR 5747 are examined using Mees Solar Observatory magnetograms taken on Oct. 20, 1989 to Oct. 22, 1989. The active region showed such violent flaring activities during the observational span that strong X-ray flares took place including a 2B/X3 flare. The magnetogram data were obtained by the Haleakala Stokes Polarimeter which provides simultaneous Stokes profiles of the Fe I doublet 6301.5 and 6302.5. A nonlinear least square method was adopted to derive the magnetic field vectors from the observed Stokes profiles and a multi-step ambiguity solution method was employed to resolve the $180^{\circ}$ ambiguity. From the ambiguity-resolved vector magnetograms, we have derived a set of physical quantities characterizing the field configuration, which are magnetic flux, vertical current density, magnetic shear angle, angular shear, magnetic free energy density, a measure of magnetic field discontinuity MAD and linear force-free coefficient. Our results show that (1) magnetic nonpotentiality is concentrated near the inversion line in the flaring sites, (2) all the physical parameters decreased with time, which may imply that the active region was in a relaxation stage of its evolution, (3) 2-D MAD has similar patterns with other nonpotential parameters, demonstrating that it can be utilized as an useful parameter of flare producing active region, and (4) the linear force-free coefficient could be a evolutionary indicator with a merit as a global nonpotential parameter.

  • PDF

PIV Measurement of Airflow in a Vertical Channel With Square Heat Source (정방형 발열체를 갖는 수직채널 내부의 공기유동 관한 PIV계측)

  • Bae, S.T.;Kim, D.K.;Kim, S.P.;Cho, D.H.;Lee, Y.H.
    • Solar Energy
    • /
    • v.17 no.3
    • /
    • pp.35-41
    • /
    • 1997
  • An experimental study was carried out in a vertical channel with square heat source by visualization equipment with laser apparatus. The image processing system consists of one commercial image board slit into a personal computer and 2-dimensional sheet light by Argon-Ion Laser with cylindrical lens and flow picture recording system. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system which adopted two-frame grey-level cross correlation algorithm. Heat source was uniform heat flux(5W). The obtained results show various flow patterns such as the kinetic energy distribution and the turbulent kinetic energy distribution.

  • PDF

Simultaneous Determination of Baicalin and Glycyrrhizin in Eul-Ja-Tang by HPLC/DAD

  • Lee, Mi-Kyeong;Lee, Ki-Yong;Kim, Seung-Hyun;Park, Jung-Hyun;Cho, Jung-Hee;Oh, Mi-Hyun;Baek, Ju-Hyun;Kim, Hyo-JIn;Kim, Young-Choong;Sung, Sang-Hyun
    • Natural Product Sciences
    • /
    • v.14 no.3
    • /
    • pp.147-151
    • /
    • 2008
  • A high performance liquid chromatographic (HPLC) method for the simultaneous determination of marker constituents, baicalin and glycyrrhizin was established for the quality control of traditional herbal medicinal preparation, Eul-Ja-Tang (EJT). Separation and quantification were successfully achieved with a Waters XTerra RP18 column ($5{\mu}m$, 4.6 mm I.D. ${\times}$ 150 mm) by gradient elution of a mixture of acetonitrile and water containing 0.03% phosphoric acid (pH 2.03) at a flow rate of 1.0 mL/min. The diode-array UV/VIS detector (DAD) was used for the detection and the wavelength for quantification was set at 250 nm. The presence of baicalin and glycyrrhizin in this decoction was ascertained by retention time, spiking with each authentic standard and UV spectrum. Both baicalin and glycyrrhizin showed good linearity ($r^2$ > 0.999) in a relatively wide concentration ranges. The R.S.D. for intra-day and inter-day precision was less than 5% and the limits of detection (LOD) were about 30 ng. The mean recovery of each compound was 99.5 - 101.2% with R.S.D. values less than 4.0%. This method was successfully applied to the determination of contents of baicalin and glycyrrhizin in three commercial products of EJT, which resulted in the difference in the contents of these compounds. These results suggest that the developed HPLC method is simple, effective and could be readily utilized as a quality control method for commercial EJT products.

Development of Map Building Algorithm for Mobile Robot by Using RFID (모바일 로봇에서 RFID를 이용한 지도작성 알고리즘 개발)

  • Kim, Si-Seup;Seon, Jeong-An;Kee, Chang-Doo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.2
    • /
    • pp.133-138
    • /
    • 2011
  • RFID system can be used to improve object recognition, map building and localization for robot area. A novel method of indoor navigation system for a mobile robot is proposed using RFID technology. The mobile robot With a RFID reader and antenna is able to find what obstacles are located where in circumstance and can build the map similar to indoor circumstance by combining RFID information and distance data obtained from sensors. Using the map obtained, the mobile robot can avoid obstacles and finally reach the desired goal by $A^*$ algorithm. 3D map which has the advantage of robot navigation and manipulation is able to be built using z dimension of products. The proposed robot navigation system is proved to apply for SLAM and path planning in unknown circumstance through numerous experiments.

Simultaneous integrated boost intensity-modulated radiotherapy versus 3-dimensional conformal radiotherapy in preoperative concurrent chemoradiotherapy for locally advanced rectal cancer

  • Bae, Bong Kyung;Kang, Min Kyu;Kim, Jae-Chul;Kim, Mi Young;Choi, Gyu-Seog;Kim, Jong Gwang;Kang, Byung Woog;Kim, Hye Jin;Park, Soo Yeun
    • Radiation Oncology Journal
    • /
    • v.35 no.3
    • /
    • pp.208-216
    • /
    • 2017
  • Purpose: To evaluate the feasibility of simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT) for preoperative concurrent chemoradiotherapy (PCRT) in locally advanced rectal cancer (LARC), by comparing with 3-dimensional conformal radiotherapy (3D-CRT). Materials and Methods: Patients who were treated with PCRT for LARC from 2015 January to 2016 December were retrospectively enrolled. Total doses of 45 Gy to 50.4 Gy with 3D-CRT or SIB-IMRT were administered concomitantly with 5-fluorouracil plus leucovorin or capecitabine. Surgery was performed 8 weeks after PCRT. Between PCRT and surgery, one cycle of additional chemotherapy was administered. Pathologic tumor responses were compared between SIB-IMRT and 3D-CRT groups. Acute gastrointestinal, genitourinary, hematologic, and skin toxicities were compared between the two groups based on the RTOG toxicity criteria. Results: SIB-IMRT was used in 53 patients, and 3D-CRT in 41 patients. After PCRT, no significant differences were noted in tumor responses, pathologic complete response (9% vs. 7%; p = 1.000), pathologic tumor regression Grade 3 or higher (85% vs. 71%; p = 0.096), and R0 resection (87% vs. 85%; p = 0.843). Grade 2 genitourinary toxicities were significantly lesser in the SIB-IMRT group (8% vs. 24%; p = 0.023), but gastrointestinal toxicities were not different across the two groups. Conclusion: SIB-IMRT showed lower GU toxicity and similar tumor responses when compared with 3D-CRT in PCRT for LARC.

Visualization and Localization of Fusion Image Using VRML for Three-dimensional Modeling of Epileptic Seizure Focus (VRML을 이용한 융합 영상에서 간질환자 발작 진원지의 3차원적 가시화와 위치 측정 구현)

  • 이상호;김동현;유선국;정해조;윤미진;손혜경;강원석;이종두;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.34-42
    • /
    • 2003
  • In medical imaging, three-dimensional (3D) display using Virtual Reality Modeling Language (VRML) as a portable file format can give intuitive information more efficiently on the World Wide Web (WWW). The web-based 3D visualization of functional images combined with anatomical images has not studied much in systematic ways. The goal of this study was to achieve a simultaneous observation of 3D anatomic and functional models with planar images on the WWW, providing their locational information in 3D space with a measuring implement using VRML. MRI and ictal-interictal SPECT images were obtained from one epileptic patient. Subtraction ictal SPECT co-registered to MRI (SISCOM) was performed to improve identification of a seizure focus. SISCOM image volumes were held by thresholds above one standard deviation (1-SD) and two standard deviations (2-SD). SISCOM foci and boundaries of gray matter, white matter, and cerebrospinal fluid (CSF) in the MRI volume were segmented and rendered to VRML polygonal surfaces by marching cube algorithm. Line profiles of x and y-axis that represent real lengths on an image were acquired and their maximum lengths were the same as 211.67 mm. The real size vs. the rendered VRML surface size was approximately the ratio of 1 to 605.9. A VRML measuring tool was made and merged with previous VRML surfaces. User interface tools were embedded with Java Script routines to display MRI planar images as cross sections of 3D surface models and to set transparencies of 3D surface models. When transparencies of 3D surface models were properly controlled, a fused display of the brain geometry with 3D distributions of focal activated regions provided intuitively spatial correlations among three 3D surface models. The epileptic seizure focus was in the right temporal lobe of the brain. The real position of the seizure focus could be verified by the VRML measuring tool and the anatomy corresponding to the seizure focus could be confirmed by MRI planar images crossing 3D surface models. The VRML application developed in this study may have several advantages. Firstly, 3D fused display and control of anatomic and functional image were achieved on the m. Secondly, the vector analysis of a 3D surface model was defined by the VRML measuring tool based on the real size. Finally, the anatomy corresponding to the seizure focus was intuitively detected by correlations with MRI images. Our web based visualization of 3-D fusion image and its localization will be a help to online research and education in diagnostic radiology, therapeutic radiology, and surgery applications.

  • PDF

Object Detection of AGV in Manufacturing Plants using Deep Learning (딥러닝 기반 제조 공장 내 AGV 객체 인식에 대한 연구)

  • Lee, Gil-Won;Lee, Hwally;Cheong, Hee-Woon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.1
    • /
    • pp.36-43
    • /
    • 2021
  • In this research, the accuracy of YOLO v3 algorithm in object detection during AGV (Automated Guided Vehicle) operation was investigated. First of all, AGV with 2D LiDAR and stereo camera was prepared. AGV was driven along the route scanned with SLAM (Simultaneous Localization and Mapping) using 2D LiDAR while front objects were detected through stereo camera. In order to evaluate the accuracy of YOLO v3 algorithm, recall, AP (Average Precision), and mAP (mean Average Precision) of the algorithm were measured with a degree of machine learning. Experimental results show that mAP, precision, and recall are improved by 10%, 6.8%, and 16.4%, respectively, when YOLO v3 is fitted with 4000 training dataset and 500 testing dataset which were collected through online search and is trained additionally with 1200 dataset collected from the stereo camera on AGV.

Modeling of sulfate ionic diffusion in porous cement based composites: effect of capillary size change

  • Gospodinov, Peter N.
    • Computers and Concrete
    • /
    • v.4 no.2
    • /
    • pp.157-166
    • /
    • 2007
  • The paper considers a theoretical model to study sulfate ion diffusion in saturated porous media - cement based mineral composites, accounting for simultaneous effects, such as filling micro-capillaries (pores) with ions and chemical products and liquid push out of them. Pore volume change and its effect on the distribution of ion concentration within the specimen are investigated. Relations for the distribution of the capillary relative radius and volume within the composite under consideration are found. The numerical algorithm used is further completed to consider capillary size change and the effects accompanying sulfate ion diffusion. Ion distribution within the cross section and volume of specimens fabricated from mineral composites is numerically studied, accounting for the change of material capillary size and volume. Characteristic cases of 2D and 3D diffusion are analyzed. The results found can be used to both assess the sulfate corrosion in saturated systems and predict changes occurring in the pore structure of the composite as a result of sulfate ion diffusion.

Effectcs of Plant Growth Regulators on Growth and Berberine Production in Cell Suspension Cultures of Thalictrum rugosum (Thalictrum rugosum 세포배양에서 식물생장 조절물질이 세포증식 및 Berberine 생산에 미치는 영향)

  • 김동일
    • Microbiology and Biotechnology Letters
    • /
    • v.18 no.4
    • /
    • pp.327-330
    • /
    • 1990
  • The effects of various plant growth regulators, both auxins and cytokinins, on cell growth and berberine production were investigated in cell suspension cultures of Thafictrum rugosum. Indole-%-acetic acid (IAA) was found to be the best for berberine production among five examined plant growth regulators and the optimum concentration of IAA was 1 $\mu \textrm M$. The enhancement compared to control 2, 4-dichlorophenoxyacetic acid (2, 4-D) was more than 60%. Simultaneous addition of cytokinins such as kinetin and 6-benzylamiroyurine (BA) was inhibitory.

  • PDF

The serum level of 25-hydroxyvitamin D for maximal suppression of parathyroid hormone in children: the relationship between 25-hydroxyvitamin D and parathyroid hormone

  • Kang, Jung In;Lee, Yoon Suk;Han, Ye Jin;Kong, Kyoung Ae;Kim, Hae Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.60 no.2
    • /
    • pp.45-49
    • /
    • 2017
  • Purpose: Serum level of 25-hydroxyvitamin D (25-OHD) is considered as the most appropriate marker of vitamin D status. However, only a few studies have investigated the relationship between 25-OHD and parathyroid hormone (PTH) in children. To this end, this study was aimed at evaluating the lowest 25-OHD level that suppresses the production of parathyroid hormone in children. Methods: A retrospective record review was performed for children aged 0.2 to 18 years (n=193; 106 boys and 87 girls) who underwent simultaneous measurements of serum 25-OHD and PTH levels between January 2010 and June 2014. Results: The inflection point of serum 25-OHD level for maximal suppression of PTH was at 18.0 ng/mL (95% confidence interval, 14.3-21.7 ng/mL). The median PTH level of the children with 25-OHD levels of <18.0 ng/mL was higher than that of children with 25-OHD levels ${\geq}$ 18.0 ng/mL (P<0.0001). The median calcium level of children with 25-OHD levels<18.0 ng/mL was lower than that of children with 25-OHD levels${\geq}18.0ng/mL$ (P=0.0001). The frequency of hyperparathyroidism was higher in the children with 25-OHD levels<18.0 ng/mL than in the children with 25-OHD levels${\geq}18.0ng/mL$ (P<0.0001). Hypocalcemia was more prevalent in the children with 25-OHD levels<18.0 ng/mL than in the children with 25-OHD levels${\geq}18.0ng/mL$ (P<0.0001). Conclusion: These data suggest that a vitamin D level of 18.0 ng/mL could be the criterion for 25-OHD deficiency in children at the inflection point of the maximal suppression of PTH.