• Title/Summary/Keyword: 27.12 MHz

Search Result 61, Processing Time 0.028 seconds

A Dual-Channel CMOS Transimpedance Amplifier Array with Automatic Gain Control for Unmanned Vehicle LADARs (무인차량 라이다용 CMOS 듀얼채널 자동 이득조절 트랜스임피던스 증폭기 어레이)

  • Hong, Chaerin;Park, Sung Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.831-835
    • /
    • 2016
  • In this paper, a dual-channel feed-forward transimpedance(TIA) array is realized in a standard $0.18-{\mu}m$ CMOS technology which exploits automatic gain control function to provide 40-dB input dynamic range for either detecting targets nearby or sensing imminent danger situations. Compared to the previously reported conventional feed-forward TIA, the proposed automatic-gain-control feed-forward TIA(AFF-TIA) extends the input dynamic range 25 dB wider by employing a 4-level automatic gain control circuit. Measured results demonstrate the linearly varying transimpedance gain of 47 to $72dB{\Omega}$, input dynamic range of 1:100, the bandwidth of $${\geq_-}670MHz$$, the equivalent input referred noise current spectral density of 6.9 pA/${\surd}$HZ, the maximum sensitivity of -26.8 dBm for $10^{-12}BER$, and the power consumption of 27.6 mW from a single 1.8-V supply. The dual-channel chip occupies the area of $1.0{\times}0.73mm^2$ including I/O pads.

Ultrasonographic Appearance of Kindney and Urinary Bladder in Relation to Growth in Native Korean Cattle (한우에서 성장에 따른 신장 및 방광의 초음파상)

  • 김명철;변홍섭;신상태;황광남;박명호;한용만;이경광
    • Journal of Veterinary Clinics
    • /
    • v.14 no.1
    • /
    • pp.19-23
    • /
    • 1997
  • Ultrasonographic diagnosis of kidney and urinary bladder disease was performed in native Korea cattle. Ultrasonogaphic appearence of kidney and urinaryy baldder according to the growth were determined from 6 to 13 months by monthly examinations in 9 native Korean cattle. The kidney and urinary bladder were examined in standing position. The position, dimension, and structure of both kidneys were determined at 12 intercostal space and paralumbar fossa by use of ultrasonography. Ultrasonograms were obtained with 3.5 or 5.0-MHz sector transducer. The width and depth of the kidney, and the diameter of renal parenchyma and renal sinus were observed. Both kidneys were observedfrom the body surface until 8 months old age, but over the 9 months old age, only right kidney was easily accessible. The width of right kidney at the 6, 7, 8, 9, 10, 11, 12 and 13 months old age were 5.7, 6.3, 6.9, 7.6, 8.4, 9.3, 9.8 and 10.7 cm, respectively. The depth 5.8, 6.1 and 6.6 cm, respectively. The size of left kidney was similar to right kidney until 8 months old age. After the 9 months old age, only right kidney was easily accessible. The circumference of urinary bladder at the 6, 7, 8, 9, 10, 11, 12 and 13 months old age were 19.1, 21.7, 22.5, 23.0, 24.2, 25.3, 27.8 and 29.1 cm, respectively. Calculi in urinary bladder were observed by ultrasonography.

  • PDF

Realization of a 7.7~8.5GHz 10 W Solid-State Power Amplifier (7.7~8.5 GHz 10 W 반도체 전력 증폭기의 구현에 관한 연구)

  • 박효달;김용구
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.12
    • /
    • pp.2489-2497
    • /
    • 1994
  • This paper presents the development of a 10 W solid-state hybrid power amplifier(SSPA). operating over $7.7\sim8.5GHz$. The fabrication and measurement of this amplifier are performed with 3 sections, such as the front one for high gain, the middle one for driving, and high power one, to minimize the risk of failure and to increase the easiness of development. and then the final amplifier is realized by connecting 3 sections above mentioned, DC bias circuit, and temperature compensation circuit on one housing. Total small signal gain obtained is about $45\pm1dB$, the input and output return losses are 25 and 27 dB respectively. The output power measured at 1 dB gain compression point for 3 frequencies at 7.7, 8.1, and 8.5 GHz are $39.8\sim40.4dBm$, which is about 10 W. and the 3rd-order harmonic powers of 2 tones test are 13.34 dBc at output power 37.5 dBm. These obtained results satisfies the initially required specification. and the realized SSPA can be installed as a subsystem of the microwave transponder for telecommunication.

  • PDF

60 GHz CMOS SoC for Millimeter Wave WPAN Applications (차세대 밀리미터파 대역 WPAN용 60 GHz CMOS SoC)

  • Lee, Jae-Jin;Jung, Dong-Yun;Oh, Inn-Yeal;Park, Chul-Soon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.6
    • /
    • pp.670-680
    • /
    • 2010
  • A low power single-chip CMOS receiver for 60 GHz mobile application are proposed in this paper. The single-chip receiver consists of a 4-stage current re-use LNA with under 4 dB NF, Cgs compensating resistive mixer with -9.4 dB conversion gain, Ka-band low phase noise VCO with -113 dBc/Hz phase noise at 1 MHz offset from 26.89 GHz, high-suppression frequency doubler with -0.45 dB conversion gain, and 2-stage current re-use drive amplifier. The size of the fabricated receiver using a standard 0.13 ${\mu}m$ CMOS technology is 2.67 mm$\times$0.75 mm including probing pads. An RF bandwidth is 6.2 GHz, from 55 to 61.2 GHz and an LO tuning range is 7.14 GHz, from 48.45 GHz to 55.59 GHz. The If bandwidth is 5.25 GHz(4.75~10 GHz) The conversion gain and input P1 dB are -9.5 dB and -12.5 dBm, respectively, at RF frequency of 59 GHz. The proposed single-chip receiver describes very good noise performances and linearity with very low DC power consumption of only 21.9 mW.

Ultrasound Guided Shoulder Joint Injection through Rotator Cuff Interval (초음파를 활용한 회전근개 간격으로 접근한 견관절 주사법)

  • Lim, Jong Bum;Kim, Young Ki;Kim, Sung Woo;Sung, Kyu Wan;Jung, Il;Lee, Chung
    • The Korean Journal of Pain
    • /
    • v.21 no.1
    • /
    • pp.57-61
    • /
    • 2008
  • Background: Shoulder joint injection is currently performed under fluoroscopic or computed tomography scan guidance. We performed this study to determine if an ultrasound guided shoulder joint injection through rotator cuff interval would have clinical usefulness. Methods: A total of 17 volunteers [12 women, 5 men; mean age 28 yr (23-32 yr)] received shoulder joint injection under multilinear ultrasound (5-10 MHz). Volunteers were positioned supinely on a table with their arm in a neutral position. The anterior shoulder region of the patient was sterilized using povidone iodine. A 24 gauge needle was introduced and directly visualized in real time as it passed obliquely from the skin surface to the inferior space of the biceps tendon. If there was little or no resistance to the injection, a contrast media (omnipaque) was injected and checked fluoroscopically. Results: Ultrasound guided shoulder joint injection through rotator cuff interval was successful in all cases. The average time taken for the procedure was $27.5{\pm}16.5sec$. The vertical distance from skin to the inferior space of the biceps tendon was $1.6{\pm}0.4cm$ and the distance of needle from the skin to the inferior space of biceps tendon was $2.8{\pm}0.6cm$. The procedure was well tolerated by all volunteers. Conclusions: Ultrasound guided shoulder joint injection through rotator cuff interval is an effective, rapid, and easy-to-perform injection technique. Ultrasound guided injection enables exact needle placement and avoids the use of both ionizing radiation and iodinated contrast material.

Quantitative Analysis of Quality Control of Natural Medicine by $^1H-NMR$ Spectrometry-Quantitative Analysis of Hesperidin from Citrus unshiu ($^1H-NMR$을 이용한 한약재의 품질 평가 방법 확립;진피의 Hesperidin 정량분석)

  • Ahn, Eun-Mi;Baek, Mi-Young
    • The Korea Journal of Herbology
    • /
    • v.23 no.3
    • /
    • pp.27-32
    • /
    • 2008
  • Objectives : In this paper, we describe that $^1H-NMR$ spectroscopy may be superior to the conventional HPLC for the quantitative analysis of hesperidin from Citrus unshiu. Methods : $^1H-NMR$ spectra (400 MHz) were recorded in $DMSO-d_6$ using a Varian UNITY Inova AS 400 FT NMR spectrometer. One hundred milligram of powdered Citrus unshiu was weighed out and mixed with 1 ml of $DMSO-d_6$ with sonication for 30 min (room temperature). The extracts were filtrated through a 0.45 ${\mu}m$ PVDF filter and 0.5 ml of filtrated extract used for quantitative $^1H-NMR$ measurement (added 1 mg of dimethyl terephthalate as internal standard). The quantity of hesperidin was calculated by the ratio of the intensity of the compound to the known amount of internal standard. For HPLC analysis, the half gram of plant material was extracted with 60 ml of MeOH for 2 hours. The extracts were made 100 ml volume and analyzed by a Waters HPLC system using a YMC ODS column. The total flow rate was 1.0 ml/min with a sample volume 10 ${\mu}l$ and UV detection at 280nm. Results : The contents of hesperidin in Citrus unshiu was determined $5.33{\pm}0.06$% in the quantitative $^1H-NMR$ method and $5.15{\pm}0.12%$ in HPLC method. Using the quantitative $^1H-NMR$ the contents of hesperidin can be determined in much shorter time than the conventional HPLC measurements. Conclusions : From those results, the advantages of quantitative $^1H-NMR$ analysis are that can be analyzed to identify and quantify, and no reference compounds required for calibration curve. Besides, it allows rapid and simple quantification for hesperidin with an analysis time for only 10 min without any pre-purification steps.

  • PDF

Therapeutic Effect of Combined Radiotherapy and Hyperthermia in Primary Hepatocellular Carcinoma (원발성 간암의 방사선치료및 온열요법의 병용치료 효과)

  • Kang Ki Mun;Choi Ihl Bohng;Kay Chul Seung;Choi Byung Ok;Chung Su Mi;Kim In Ah;Han Sung Tae;Sun Hee Sik;Chung Kyu Won;Shinn Keyong Sub
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.191-199
    • /
    • 1994
  • Purpose : This study was undertaken to show the clinical results of combined radiotherapy and hyperthermia in primary hepatoma Materials and Methods : Between December 1989 and March 1993, 50 patients with hepatomas were treated by combined radiotherapy and hyperthermia. Among them, we analyzed retrospectively 33 patients who received the complete course of treatment. The ages of the patients ranged from 36 to 75(mean age: 55.5 years). Twenty-six patients ($78.8\%$) were men, and 7 ($21.2\%$ were women. According to Child's classification, nine patients ($27.3{\%}$) were A group, 9 ($27.3\%$) were B group, 15 ($45.4\%$) were C group. Radiation therapy was done by a 6 MV and 15 MV linear accelerator. Patients were treated with daily fractions of 150-180 cCy to doses of 2550 cGy -4950 cGy (median : 3000 cGy). Local hyperthermia was done by 8 MHZ RF capacitive heating device (Cancermia. Green Cross Co., Korea), 50-60 min/session, 1-2 sessions/wk, and 8.5 sessions (median number)/patient. We analyzed the prognostic factors including age, sex, tumor type, Child's classification, $\alpha$-fetoprotein, liver cirrhosis, ascites, portal vein invasion, esophageal varix, number of hyperthermia, chemotherapy, total bilirubin level, Karnofsky perfomance status. Results : The overall 1-year survival was $24.2\%$, with a mean survival of 10months. Of 33 patients, tumor regression (PR+MR) was seen in $30.4\%$, no response was seen in $52.2\%,\;17.4\%$ patient was progressed. In patients who had tumor regression, the overall 1-year survival was $42.1\%$ with a mean survival of 14 months. Factors influencing the survival were sex (p=0.05), tumor type (p=0.0248), Child's classification (p=0.0001), liver cirrhosis (p=0.0108), ascites (p=0.0009), and Karnofsky perfomance status (p=0.0028). Complications developed in 28 patients, including 18 hot pain,5 fat necrosis, 3 transient fever, 2 nausea and vomiting. Conclusion : In this study, the results suggests that combined radiotherauy and hyperthermia may improve the survival rate of hepatoma.

  • PDF

Annealing Effect and Tunability of BaZr0.08Ti0.92O3 Polycrystal Grown in N2 Gas Atmosphere by Floating Zone Technique (Floating Zone Technique법으로 질소분위기 하에서 성장한 BaZr0.08Ti0.92O3 다결정의 Tunability 및 열처리 효과)

  • Hwang, Ho-Byong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.11
    • /
    • pp.1178-1185
    • /
    • 2004
  • In the atmosphere of $N_2$ gas, BaZ $r_{0.08}$ $Ti_{0.92}$ $O_3$ polycrystal was grown by floating zone technique using BaZ $r_{0.08}$ $Ti_{0.92}$ $O_3$ ceramics as a feed and SrTi $O_3$(1l0) single cystal as a seed. The dielectric constant and loss at 10 kHz, 100 kHz, and 1 MHz for the as-grown sample were measured as a function of temperature in the temperature range between -10$0^{\circ}C$ and 150 $^{\circ}C$ to find a dielectric peak with frequency dispersion at Curie point. The hysteresis loop showed that the grown sample had very small polarization which was 0-0.01 $\mu$C/$\textrm{cm}^2$ for the applied dc-electric fields from -7 kV/cm to +7 kV/cm. However, the normal hysteresis loop was appeared after oxygen annealing. The electric-field dependence of the dielectric constant for both the as-grown and the post-annealed samples was studied by measuring the dielectric constants as a function of the biased-electric fields and their tunability was figured out from it at room temperature(27 $^{\circ}C$) and cryotemperature( -73$^{\circ}C$). Tunability for the as-grown sample was 51 % and the figure of merit 20.4 at 10kHz with the biased electric-field of 12 kV/cm. The tunability for the grown sample may be increased up to 80 % if the electric field of 25 kV/cm is applied. Tunability for the post-annealed sample was 41 % and the figure of merit 10.3 at 10 kHz with the biased electric-field of 12 kV /cm. Post-annealing improved the crystallinity of the as-grown sample but decreased its tunability.ability.

Evaluation of Sodium Intake and Relationship between Sodium Intake and the Bone Mineral Density of Female University Students (중부 지역 여대생에서 음식섭취빈도조사지를 이용한 나트륨 섭취량 평가 및 나트륨 섭취와 골밀도와의 관련성 조사)

  • Bae, Yun-Jung;Yeon, Jee-Young
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.21 no.5
    • /
    • pp.625-636
    • /
    • 2011
  • The purpose of this study was to evaluate the relationship between bone health and sodium intake in female university students using a dish frequency questionnaire (DFQ 125), anthropometric checkups, food records for 3 days, and ultrasound measurement of calcaneus bone mineral density. Subjects were divided into two groups: normal (n=196) and osteopenia (n=52). There were no significant differences in age or height between the two groups. The average weight, body mass index, and body fat in the normal group were significantly higher than in the osteopenia group. The sodium intake of DFQ was positively correlated with the sodium intake of 3 days of dietary records (p=0.0003). There were no significant differences in the sodium intake between the two groups from DFQ. The dishes were ranked by sodium intake: kimchies were 17.68%, noodles and mandu were 16.36%, stews were 13.69%, main dishes such as meat, egg, and beans were 11.47%, and fish and shellfish were 11.07%. The frequency of eating noodles and mandu (p=0.0116), stews (p=0.0008), kimchies (p=0.0482), fish and shellfish (p=0.0362), vegetables (p=0.0064) and seasoning (p=0.0347) were negatively associated with bone mineral density. Bone health was not significantly different with increasing quartiles of sodium intake. As excessive sodium intakes may indirectly affect bone mineral density, these results suggest that to prevent osteoporosis, university students needed to be more educated about diets containing less sodium through nutrition education programs.

Ultrasound Imaging of Normal Cardiac Structures with Convex Scanner in Puppies (강아지에서 컨벡스스캐너를 이용한 정상적인 심장구조물의 초음파상)

  • Jeong Soon-wuk;Park Hee-myung;Han Sook-hee;Yoon Jung-hee;Han Hong-ryul
    • Journal of Veterinary Clinics
    • /
    • v.11 no.2
    • /
    • pp.529-537
    • /
    • 1994
  • Sector scanner which has a conical end is used to image through the intercostal space because heart is protected by the ribs. Cardiac data published all around the world were also obtained by sector scanner. Although scanners being used in every small animal practice and animal hospital at college in Korea include convex ape and linear type, linear type is not appropriate f3r cardiac scan because of a wide contact surface. The purpose of this study is to establish ultrasonographic images of normal cardiac structures by measuring shape, size of reflectable cardiac structure according to restraint position in scanning normal heart of the puppies with 6.5 MHz convex scanner(SonoAce 4500, Medison, Korea) used in our veterinary teaching hospital, Seoul national university. Seventeen male and female puppies considered having healthy hear by X-ray and clinical examination are used feom April to July 1994. Scanning point selection of probe head and the distinction of imaged cardiac structures were accomplished by necropsy and cardiac scanning performed through thoracotomy under general anesthesia. At 10 o'clock position of transducer(at an angle of 30$^{\circ}$ between imaginary line from elbow joint to 3rd sternum and probe head, 60$^{\circ}$ from body surface, 4th intercostal space of right thorax) with the marker of scanner toward the head of dogs right atrium, left atrium and left ventricle were observed in 2, 3, 4, 5 intercostal space(2cm from the sternum) of experimental dog positioned ventrodorsally under general anesthesia. Under these conditions, the numerical values of imaged diastolic hear are as follows : the distance from skin to apex(mean$\pm$S.D) 47.53$\pm$6.94mm, thickness of left ventricular wall 6.00$\pm$1.60mm, length of left ventricle 16.27$\pm$5.31mm, width of left ventricle 15,33$\pm$4.25mm, length of left atrium 12.33$\pm$3.82mm, width of left atrium 11. 33$\pm$3.94mm, length of right atrium 1.00$\pm$2.41mm, width of right atrium 11.21$\pm$2.76mm and the area of left ventricle 270.92$\pm$109.81mm$^2$, area of left atrium 98.00$\pm$41.08mm$^2$, area of right atrium 62.75$\pm$21.04mm$^2$.

  • PDF