• Title/Summary/Keyword: 27.12 MHz

Search Result 61, Processing Time 0.021 seconds

A Study on Fabrication and Performance Evaluation of a Driving Amplifier Stage for UHF Transmitter in Digital TV Repeater (DTV 중계기에서의 UHF 전송장치용 구동증폭단의 구현 및 성능평가에 관한 연구)

  • Lee, Young-Sub;Jeon, Joong-Sung
    • Journal of Navigation and Port Research
    • /
    • v.27 no.5
    • /
    • pp.505-511
    • /
    • 2003
  • In this paper, a driving amplifier stage with 1 Watt output has been designed and fabricated, which is operating at UHF band( 470 ∼ 806 MHz) for digital TV repeater. In the driving amplifier stage, preamplifier and 1 Watt unit amplifier are integrated by one electric substrate which is 2.53 in dielectric constant and 0.8 mm thickness. When the driving amplifier stage is flown by bias voltage of 28 V DC and current of 900 mA. it has the gain of more than 53.5 dB. the gain flatness of $\pm$0.5 dB and return loss of less than -15 dB in 470 ∼ 806 MHz. Also, when two signals at 2 MHz frequency interval are input port into the driving amplifier stage with 1 Watt output, it resulted in excellent characteristics to designed specification with showing intermodulation distortion characteristics of more than 48 dBc.

Design of a 12Bit Digital to Analog converter Using Current Scaler and Divider (전류 축척기와 분배기를 사용한 12Bit D/A 변환기 설계)

  • Yune Gun Shik;Park Cheong Yong;Ha Sung Min;Yoo Kwang Sub
    • Proceedings of the IEEK Conference
    • /
    • 2004.06b
    • /
    • pp.569-572
    • /
    • 2004
  • This paper presents a 12-Bit 250MHz CMOS current-mode Digital to Analog Converter(DAC) with current scalers and dividers. It consist of 4 MSB current scaler, 4 MLSB current divider, and 4 LSB current divider. The simulation results show a conversion rate of 250MHz, DNL/INL of ${\pm}5LSB/{\pm}7LSB$, die area of $0.55mm^2$ and Power dissipation of 27mW at 3.3V

  • PDF

Dual-Band Array Antenna Using Modified Sierpinski Fractal Structure (변형된 Sierpinski 프랙탈 구조를 갖는 이중 대역 배열 안테나)

  • Oh, Kyung-hyun;Kim, Byoung-chul;Cheong, Chi-hyun;Kim, Kun-woo;Lee, Duk-young;Choo, Ho-sung;Park, Ik-mo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.9
    • /
    • pp.921-932
    • /
    • 2010
  • This paper presents a dual-band array antenna based on a modified Sierpinski fractal structure. Array structure is mirror symmetric, and forms broadside radiation pattern for dual frequency band if the ports are fed with $180^{\circ}C$ phase difference between upper and lower $2{\times}1$ array. To use in-phase corporate feeding circuit, the phase inversion structure is designed by changing the position of patch and ground for upper and lower array. The dimensions of the array antenna is $28{\times}30{\times}5\;cm^3$ and the bandwidth of 855~1,380 MHz(47 %), 1,770~2,330 MHz(27 %) were achieved for -10 dB return loss. The measured gain is 9.06~12.44 dBi for the first band and 11.76~14.84 dBi for the second band. The half power beam width is $57^{\circ}$ for x-z plane and $46^{\circ}$ for y-z plane at 1,100 MHz and $43^{\circ}$ and $28^{\circ}$ at 2,050 MHz, respectively.

Effects of 27.12 MHz Radio Frequency on the Rapid and Uniform Tempering of Cylindrical Frozen Pork Loin (Longissimus thoracis et lumborum)

  • Choi, Eun Ji;Park, Hae Woong;Yang, Hui Seon;Kim, Jin Se;Chun, Ho Hyun
    • Food Science of Animal Resources
    • /
    • v.37 no.4
    • /
    • pp.518-528
    • /
    • 2017
  • Quality characteristics of frozen cylindrical pork loin were evaluated following different tempering methods: 27.12 MHz curved-electrode radio frequency (RF) at 1000 and 1500 W, and forced-air convection (FC) or water immersion (WI) at $4^{\circ}C$ and $20^{\circ}C$. The developed RF tempering system with the newly designed curved-electrode achieved relatively uniform tempering compared to a parallel-plate RF system. FC tempering at $4^{\circ}C$ was the most time-consuming process, whereas 1500 W RF was the shortest. Pork sample drip loss, water holding capacity, color, and microbiological quality declined after WI tempering at $20^{\circ}C$. Conversely, RF tempering yielded minimal sample changes in drip loss, microstructure, color, and total aerobic bacteria counts, along with relatively uniform internal sample temperature distributions compared to those of the other tempering treatments. These results indicate that curved-electrode RF tempering could be used to provide rapid defrosting with minimal quality deterioration of cylindrical frozen meat block products.

CCP and ICP Combination Impedance Matching Device for Uniformity Improvement of Semiconductor Plasma Etching System (반도체 플라즈마 식각 시스템의 균일도 향상을 위한 CCP와 ICP 결합 임피던스정합 장치)

  • Jung, Doo-Yong;Nam, Chang-Woo;Lee, Jong-Ho;Choi, Dae-Kyu;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.274-281
    • /
    • 2010
  • This paper proposes a DFPS (Dual Frequency Power Source) impedance matching device for uniformity improvement of a semiconductor plasma etching system. The DFPS consists of two parts for safe plasma processing on large-area substrates. The first part is an ICP (Inductively Coupled Plasma) for high integration by using ferrite core. The second part is a CCP (Capacitive Coupled Plasma) to control uniformity of whole cells. Proposed DFPS can achieve high productivity improvement required for semiconductor equipment industry. The proposed plasma system is analyzed, simulated and experimentally verified with a matching equipment at 27.12MHz and 400kHz.

Antenna-Diplexer Module for Cellular/SDMB Band Using LTCC Technology (LTCC 공법을 사용한 Cellular/SDMB 안테나-다이플렉서 모듈)

  • Ha, Jeung-Uk;Chang, Ki-Hun;Yoon, Young-Joong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.7
    • /
    • pp.774-783
    • /
    • 2007
  • This paper presents an integrated packaging antenna-diplexer module for wireless communication systems in the Cellular and SDMB band. The design and the realization of the proposed one are experimentally analyzed and discussed. It consists of a dual-resonance antenna and a diplexer with a multi-layer LTCC(${\varepsilon}_r=7.8,\;tan\;{\delta}=0.0043$) technology with integration capability and low loss. The dual-resonance antenna of the proposed module has the meander line structure for size reduction and has the shorting structure of an inverted F antenna to achieve good impedance matching. The diplexer of the proposed module was designed with the combination of low pass filter(LPF) and high pass filter(HPF). Decreasing the mutual interference between them provides a high isolation characteristic. The proposed antenna-diplexer module with dimensions of $27.5{\times}12.0{\times}2.2mm$ operates within a range from 813 MHz to 902 MHz for the cellular band and from 2,586 MHz to 2,655 MHz for the SDMB band. And the measured gain of the fabricated module is -1.96 dBi for Cellular band and -5.43 dBi for SDMB band. The parameters for the antenna-diplexer module are investigated and the several performances are discussed.

Reduction of Radiated Emission of an Infrared Camera Using a Spread Spectrum Clock Generator (확산 스펙트럼 생성기를 이용한 적외선 카메라의 방사노이즈 저감에 관한 연구)

  • Choi, Bongjun;Lee, Yongchun;Yoon, Juhyun;Kim, Eunjun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.12
    • /
    • pp.1097-1104
    • /
    • 2016
  • The infrared camera is difficult to satisfy the RE-102 specification of Mil-Std-461. Especially, in the case of UAV electronics, shielded cable is not used, so it is difficult to meet the electromagnetic compatibility standard. In the RE-102 test of the IR camera for UAV, radiated noise exceeding 30 dBuV/m was observed in the range of 50 MHz to 200 MHz. As a result of pcb em scan, peak noise which caused by the harmonic frequency of the digital control signal clock was observed. Radiated noise was reduced by up to 22.9 dBuV/m by applying the spread spectrum clock generator(SSCG) with 3 % down spreading method to the camera control clock.

Fully Differential 5-GHz LC-Tank VCOs with Improved Phase Noise and Wide Tuning Range

  • Lee, Ja-Yol;Park, Chan-Woo;Lee, Sang-Heung;Kang, Jin-Young;Oh, Seung-Hyeub
    • ETRI Journal
    • /
    • v.27 no.5
    • /
    • pp.473-483
    • /
    • 2005
  • In this paper, we propose two LC voltage-controlled oscillators (VCOs) that improve both phase noise and tuning range. With both 1/f induced low-frequency noise and low-frequency thermal noise around DC or around harmonics suppressed significantly by the employment of a current-current negative feedback (CCNF) loop, the phase noise in the CCNF LC VCO has been improved by about 10 dB at 6 MHz offset compared to the conventional LC VCO. The phase noise of the CCNF VCO was measured as -112 dBc/Hz at 6 MHz offset from 5.5 GHz carrier frequency. Also, we present a bandwidth-enhanced LC VCO whose tuning range has been increased about 250 % by connecting the varactor to the bases of the cross-coupled pair. The phase noise of the bandwidth-enhanced LC-tank VCO has been improved by about 6 dB at 6 MHz offset compared to the conventional LC VCO. The phase noise reduction has been achieved because the DC-decoupling capacitor Cc prevents the output common-mode level from modulating the varactor bias point, and the signal power increases in the LC-tank resonator. The bandwidth-enhanced LC VCO represents a 12 % bandwidth and phase noise of -108 dBc/Hz at 6 MHz offset.

  • PDF

Analysis of Inductively Coupled Plasma using Electrostatic Probe and Fluid Simulation (정전 탐침법과 유체 시뮬레이션을 이용한 유도결합 Ar 플라즈마의 특성 연구)

  • Cha, Ju-Hong;Lee, Ho-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1211-1217
    • /
    • 2016
  • Discharge characteristics of inductively coupled plasma were investigated by using electrostatic probe and fluid simulation. The Inductively Coupled Plasma source driven by 13.56 Mhz was prepared. The signal attenuation ratios of the electrostatic probe at first and second harmonic frequency was tuned in 13.56Mhz and 27.12Mhz respectively. Electron temperature, electron density, plasma potential, electron energy distribution function and electron energy probability function were investigated by using the electrostatic probe. Experiment results were compared with the fluid simulation results. Ar plasma fluid simulations including Navier-Stokes equations were calculated under the same experiment conditions, and the dependencies of plasma parameters on process parameters were well agreed with simulation results. Because of the reason that the more collision happens in high pressure condition, plasma potential and electron temperature got lower as the pressure was higher and the input power was higher, but Electron density was higher under the same condition. Due to the same reason, the electron energy distribution was widening as the pressure was lower. And the electron density was higher, as close to the gas inlet place. It was found that gas flow field significantly affect to spatial distribution of electron density and temperature.

Ultrasonographic Appearance of Liver and Duodenum in Relation to Growth in Native Korean Cattle (한우에서 성장에 따른 간장 및 십이지장의 초음파상)

  • 김명철;변홍섭;신상태;황광남;박명호;이경광;한용만;박경수
    • Journal of Veterinary Clinics
    • /
    • v.14 no.1
    • /
    • pp.11-18
    • /
    • 1997
  • This study was performed to make fundamental data of ultrasonographic diagnosis for liver and duodenum disease in native Korean cattle. Ultrasonographic appearance of liver, caudal vena cava, portal vein, gall bladdr and duodenum according to the growth were determined from 6 to 13 months by monthly examinations in 9 native Korean cattle. The caudal vena cava was determined at 11th intercostal space by use of ultrasonography. The portal vein and gallbladder were determined at 10th intercostal space by use oof ultrasonography. The liver were determined at 12, 11 and 10 th intercostal space by use of ultrasonography. The liver, caudal vena cava, portal cein, gallbladder and duodenum were examinde in standing position. Ultrasonograms were obtainde with 3.5 or 5.0-MHz convex and 5.0-MHz sector transducer. The diameter of vena cava at the 6, 7, 8, 9, 10, 11, 12 and 13 months old age were 18.4, 20.6, 22.4, 25.1, 26.9, 27.3, 28.5 and 29.4 mm, respectively. The diameter of portal vein at the 6, 7, 8, 9, 10, 11, 12 and 13 months old age were 19.5, 20.6, 22.3, 24.5, 26.9, 28.1, 30.7 and 31.5 mm, respectively. The diameter of gall bladder at the 6, 7, 8, 9, 10, 11, 12 and 13 months old age were 63.2, 72.2, 75.1, 78.6, 80.5, 82.3, 84.4 and 91.1 mm, respectively. Cranial part of duodenum was identified near gall bladder by moving of hyperechoic ingesta. Descending duodenum paralleled with vertebrae is seen in the right upper flank and was adjacent to the abdominal wall, and was enveloped in the hyperechoic greater omentum, differentiating it from the jejunum and ileum. The diameter of cranial duodenum at the 6, 7, 8, 9, 10, 11, 12 and 13 months old age were 23.3, 27.9, 29.9, 32.2, 34.4, 34.5, 35.1 and 36.5 mm, respectively. The diameter of descending duodenum revealed smaller diameter than that of cranial duodenum. Calculi in gallbladder were observed by ultrasonography.

  • PDF