• Title/Summary/Keyword: 22kV class

Search Result 93, Processing Time 0.027 seconds

EDGE COVERING COLORING OF NEARLY BIPARTITE GRAPHS

  • Wang Ji-Hui;Zhang Xia;Liu Guizhen
    • Journal of applied mathematics & informatics
    • /
    • v.22 no.1_2
    • /
    • pp.435-440
    • /
    • 2006
  • Let G be a simple graph with vertex set V(G) and edge set E(G). A subset S of E(G) is called an edge cover of G if the subgraph induced by S is a spanning subgraph of G. The maximum number of edge covers which form a partition of E(G) is called edge covering chromatic number of G, denoted by X'c(G). It is known that for any graph G with minimum degree ${\delta},\;{\delta}-1{\le}X'c(G){\le}{\delta}$. If $X'c(G) ={\delta}$, then G is called a graph of CI class, otherwise G is called a graph of CII class. It is easy to prove that the problem of deciding whether a given graph is of CI class or CII class is NP-complete. In this paper, we consider the classification of nearly bipartite graph and give some sufficient conditions for a nearly bipartite graph to be of CI class.

Vascular Plants of Mt. Munsu and Mt. Okseok (문수산.옥석산 일대의 식물상)

  • Kim, Hye-Jin;Yun, Chung-Weon
    • Korean Journal of Environmental Biology
    • /
    • v.27 no.2
    • /
    • pp.164-175
    • /
    • 2009
  • The flora of the vascular plant in Mt. Munsu and Mt. Okseok was listed as 689 taxa; 95 families, 332 genus, 600 species, 93 varieties and 5 forms. Based on the list of rare plants by Korea Forest Service and Korea Forest Research Institute, 16 taxa were recorded. And endangered plant was recorded by 1 taxa, Iris koreana var. albiflora. Based on the list of Korean endemic plant, 44 taxa were recorded. According to the specific plant species by classes, class I has 51 taxa, class II has 33 taxa, class III has 28 taxa, class IV has 12 taxa. In class V, we found Houttuynia cordata, but the species was considered to be worthless because it was planted as an ornamental plant in the area. Naturalized plant species were listed as 27 taxa; 99 families, 22 genus, 26 species, 1 varieties. And naturalization index was 3.9%.

A Multi-Epoch, Simultaneous Water and Methanol Maser Survey Toward Intermediate-Mass Young Stellar Objects

  • Bae, Jae-Han;Kim, Kee-Tae;Youn, So-Young;Kim, Won-Ju;Byun, Do-Young;Kang, Hyun-Woo;Oh, Chung-Sik
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.83.1-83.1
    • /
    • 2011
  • We report multi-epoch, simultaneous 22 GHz water and 44 GHz Class I methanol maser line survey towards 180 intermediate-mass young stellar objects, including 14 Class 0, 19 Class I objects, and 147 Herbig Ae/Be stars. We detected $H_2O$ and $CH_3OH$ maser emission towards 16 (9%) and 10 (6%) sources with one new $H_2O$ and six new $CH_3OH$ maser sources. The detection rates of both masers rapidly decrease as the central (proto)stars evolve, which is contrary to the trends in high-mass star-forming regions. This suggests that the excitations of the two masers are closely related to the evolutionary stage of the central (proto)stars and the circumstellar environments. $H_2O$ maser velocities deviate on average 9 km s-1 from the ambient gas velocities whereas $CH_3OH$ maser velocities well match with. For both maser emissions, large velocity difference (${\mid}v_{H2O}-v_{sys}{\mid}\;>\; 10kms^{-1}\; and\;{\mid}v_{CH3OH}-v_{sys}{\mid}\;>\;1kms^{-1}$) is mostly confined to Class 0 objects. The formation and disappearance of $H_2O$ maser lines are frequent and the integrated intensities of them change up to two orders of magnitude. In contrast, $CH_3OH$ maser lines usually show no significant change in the intensity, shape, and velocity. This consistent with the previous suggestion that $H_2O$ maser emission originates from the base of an outflow while 44 GHz Class I $CH_3OH$ maser emission arises from the interaction region of the outflow with the ambient gas. The isotropic maser luminosities are well correlated with the bolometric luminosities of the central the objects. The fitted relations are $L_{H2O}=1.71{\ast}10^{-9}(L_{bol})^{0.97}$ and $L_{CH3OH}=1.71{\ast}10^{-10}(L_{bol})^{1.22}$.

  • PDF

A Study of DC/AC Characteristics on 22.9 kV distribution class HTS-cable (22.9 kV 배전급 초전도케이블의 DC/AC 특성에 관한 연구)

  • Ma, Y.H.;Ryu, K.;Sohn, S.H.;Lim, J.H.;Hwang, S.D.;Choi, H.O.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.287-287
    • /
    • 2008
  • HTS-케이블은 구리도체 대신 고온초전도도체를 사용하여 저항이 0이 되는 초전도현상을 이용하여 대용량 전력수송이 가능한 전력케이블로서 대도시의 전력부하 집중문제를 해결할 수 있는 환경 친화적 전력케이블이다. 최근 고온초전도선재의 고임계전류밀도화 및 장척화에 힘입어 HTS-케이블의 실용화를 목표로 경제성이 있는 전력케이블을 개발하려는 움직임뿐만 아니라 실증시험 등 활발한 연구가 진행 중이다. 그러나 초전도전력케이블에서 발생되는 교류손실은 케이블의 효율을 저하시킬 뿐만 아니라 냉동기비용 증가로 인한 기존 케이블과의 가격경쟁에서 경제성을 저하시키는 주된 요인으로 작용하기 때문에 이의 상용화에 앞서 교류손실에 대한 정확한 규명이 되어야 하며 또한 실계통 투입 시 중요한 선로임피던스에 대한 정확한 규명도 필요하다. 본 논문에서는 실제 한전 주관으로 고창시험장에 설치된 배전급 22.9 kV, 100 m, 50 MVA급 3 상 HTS-케이블에 대한 통전특성을 규명하기 위하여 먼저 HTS-케이블의 DC 통전특성을 조사하였다. 또한 3상평형운전상태에서 AC 통전특성(인덕턴스 및 교류손실)을 실험적으로 조사하였으며 5m-케이블에서 측정된 결과와 비교 검토하였다.

  • PDF

Reliability Assesment of 22.9kV High Temperature Superconducting Cable System (22.9kV 초전도케이블 시스템의 신뢰성 평가)

  • Sohn, Song-Ho;Lim, Ji-Hyun;Sung, Tae-Hyun;Ryoo, Hee-Suk;Yang, Hyung-Suk;Kim, Dong-Lak;Hwang, Si-Dole
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.248-248
    • /
    • 2007
  • Demands for electricity are growing, whereas the rate of electricity infrastructure's construction declines gradually. To keep the balance of the demand and supply, the share of underground transmission line will be increased from 8.3% to 10.5% in 2020 but it will be accompanied with enormous public expenses. A great concern in high capacity transmission is on the increase so as to maximize the spacial efficiency. High Temperature Superconducting (HTS) cable is in the lime light which has the merits of environment-friendly, low transmission loss and high transmission with low voltage, but the reliability verification as a power system is yet to be solved. KEPCO completed the installation and acceptance of $3{\phi}$, 22.9kV, 1250A class HTS cable system in 2006 and the long term test is in progress. The test results focusing on long term reliability are presented in this paper.

  • PDF

Ga2O3 Epi Growth by HVPE for Application of Power Semiconductors (전력 반도체 응용을 위한 HVPE법에 의한 Ga2O3 에피성장에 관한 연구)

  • Kang, Ey Goo
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.427-431
    • /
    • 2018
  • This research was worked about $Ga_2O_3$ Epi wafer that was one of the mose wide band gap semiconductors to be used power semiconductor industry. This wafer was grown $5.3{\mu}m$ thickness on Sn doped $Ga_2O_3$ Substrate by HVPE(Hydride Vapor Phase Epitaxy). Generally, we can fabricate 600V class power semiconductor devices when the thickness of compoound power semiconductor is $5{\mu}m$. but in case of $Ga_2O_3$ Epi wafer, we can obtain over 1000V class. As a result of J-V measurment of the grown $Ga_2O_3$ Epi wafer, we obtain $2.9-7.7m{\Omega}{\cdot}cm^2$ on resistance. Specially, in case of reverse, we comfirmed a little leakage current when the reverse voltage is over 200V.

Analysis of the Stumpage Valuation for Pinus koraiensis Stands in the Research Forest of Kangwon National University

  • Woo, Hee-Sung;Choi, Sang-Hyun;Ahn, Seung-Il;Woo, Jong-Choon
    • Journal of Forest and Environmental Science
    • /
    • v.28 no.1
    • /
    • pp.24-29
    • /
    • 2012
  • This paper assesses the stmpage value of Korean white pine (Pinus koraiensis) stands in the Research Forest of Kangwon National University. Assessment was done by means of the cost value method (Faustmann formula) for age class I, Glaser method for age class II-V, and inversion market method for age class over VI. Generally the value of stumpage is calculated by the inversion market method in the market. However, immature trees and middle age class trees are not assessed in market, and the Korean forest is not old enough to harvest. So, when forests are damaged by attacks from forest fire, blight and harmful insects, the forest cannot be compensated for the loss from the government or insurance company. For this reason, the value of all-age class trees are calculated by using appropriate methods. As a result, the value of age I class stands (0.3 ha) is calculated as 1,786,305 (won), age II-Vclass stands (22.1 ha) 206,677,975 (won) and age VI class and over stands (24.8 ha) 523,789,603 (won).

A study on the computer diagnosis that apply Neural-Fuzzy algorithm accumulation detection of Partial Discharge signal (부분방전 신호의 누적검출과 뉴럴-퍼지 알고리즘을 이용한 컴퓨터 진단에 관한 연구)

  • Hwang, Kyoung-Jun;Yeoum, Keoung-Tae;Kim, Yong-Kab;Kim, Jin-Su
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1445-1446
    • /
    • 2007
  • In this paper, we have studied for analysis of the partial discharge(PD) signal in power transmission line. The PD signal has estimated as detected signal accumulation of a PRPDA method by using Labview, and analyzed with neural-fuzzy algorithm. With practical PD logic implementation of theoretical detected system and hardware implementation, the device for Hipotronics Company's 22.9kV or 154kV setup have generated and then have applied with 18kV,20kV with 1:1 time probe. It's also used the LDPE 0.27mmt (scratch error 0.05mmt) to sample for making PD. Our new class of PD detected algorithm have also compared with previous PRPDA or Neural Fuzzy algorithm, which has diagnose more conveniently by adding numerical values.

  • PDF

A fault current analysis and parallel FCL scheme on superconducting new power system (초전도(신)전력계통 고장전류 분석 및 병렬한류시스템)

  • Yoon, Jae-Young;Lee, Seung-Ryul;Kim, Jong-Yul
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.49-53
    • /
    • 2006
  • This paper specifies the new power supply paradigm converting 154kV voltage level into 22.9kV class with equivalent capacity using superconducting rower facilities and analyze the fault current characteristics with and without HTS-FCL (High Temperature Superconducting-Fault Current Limiter). Superconducting new power system is the power system to which applies the 22.9kV HTS cable in parallel to HTS transformer and HTS-FCL with low-voltage and mass-capacity characteristics replacing 154kV conventional cable and transformer. The fault current of superconducting new power system will increase greatly because of the mass capacity and low impedance of HTS transformer and cable. This means that the HTS-FCL is necessary to reduce the fault current below the breaking current of circuit breaker. This paper analyze the fault current and suggests the parallel HTS-FCL scheme complementing the inherent problem of HTS-FCL, that is recovery after quenching is impossible within shorter than a few seconds.

A Study on the degradation Analysis Using Neuro-Fuzzy Algorithm (뉴로-퍼지 알고리즘을 이용한 전력 설비의 열화 상태 분석 연구)

  • Hwang, Kyoung-Jun;Lee, Hyun-Ryoun;Choi, Yoo-Seun;Kim, Yong-Kab
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.224-226
    • /
    • 2006
  • In this paper, we have studied for analysis of the partial discharge(PD) signal in power transmission line. The PD signal has estimated as detected signal accumulation of a PRPDA method by using Labview, and analyzed with neuro-fuzzy algorithm. With practical PD logic implementation of theoretical detected system and hardware implementation, the device for Hipotronics Company's 22.9kV or 154kV setup has generated and then has applied with 18kV,20kV with 1:1 time probe. It's also used the LDPE O.27mmt (scratch error O.05mmt) to sample for making PD. Our new class of PD detected algorithm has also compared with previous PRPDA or Fuzzy algorithm, which has diagnose more conveniently by adding numerical values.

  • PDF