• Title/Summary/Keyword: 220V

Search Result 607, Processing Time 0.028 seconds

A study on the THD reduction of single phase 2 level inverter for grid connection for ship (선박 계통연계형 단상 2레벨 인버터의 THD 저감에 관한 연구)

  • Kim, Jung-Hoon;Kim, Sung-Hwan;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.64-69
    • /
    • 2014
  • There are 440V and 220V electric source in ship. A 440V source is used to drive the power system such as crane and winch on deck and pump in engine room, and a 220V source is used to drive the power source for residential zones, control devices in engine room. In this paper, we made single phase inverter system for grid connection with 220V source for ship, and analyzed THD(Total harmonic distortion) by variation of parameters of L-C low pass filter and deadtime of inverter switching.

A Study on the Insulation Methods of 220V Home Appliances and Wiring Devices (승압에 따르는 220V용 전기기기의 절연방식 결정에 관한 연구)

  • Sung Won Rhee
    • 전기의세계
    • /
    • v.20 no.4
    • /
    • pp.5-11
    • /
    • 1971
  • This is a study on the insulation methods of home appliances and wiring devices proper to the new electric distribution system, primary side is 22.9/13.2KV, 3 phase 4 wire multigrounding system and secondary side is 380/220V, 3 phase 4 wire common neutral system. 1800V is determined as the electrical insulation voltage of the functional insulation because the abnormal voltage rise of the neutral line is 1300V. In the case of the functional insulation faults, the following safety methods will be suggested to protect the accidental faults: (a) class I appliance (accessible metal part is earthed), (b) class II appliance (doublly insulated), (c) class III appliance (operates at low voltage source). The mechanisms of the wiring devices are not improved to guarantee for the harmful electric shock but also the electrical insulation voltage is rised to 2000V.

  • PDF

Development of 220kV 1C*2000SQ Slip-on Type EB-G Ass'y (220kV 1C*2000SQ Slip-on Type EB-G 접속재 개발)

  • Kim, Young-Tek;Kim, Hyun-Ju;Kim, Han-Hwa;Park, Jeong-Ki;Kim, Duk-Hwan;Lee, Kang-Mi
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1612-1613
    • /
    • 2011
  • 초고압 XLPE 케이블용 접속재는 고도의 신뢰성과 안정성이 요구되며, 국내외적으로 제품 경량화, 시공 공정 단순화 등 고객의 다양한 요구가 점차 증가하는 추세이다. 당사는 220kV 1C${\times}$2000SQ XLPE 케이블 접속재인 EB-G(가스중 종단접속함)를 Slip-on Type으로 적용함으로써 고객의 요구에 맞춰 단순한 내부절연구조에서 비롯되는 전기적 특성의 안정성과 신속한 시공성을 확보하게 되었다. 본고에서는 220kV급 접속재인 가스중종단접속함(EB-G)의 설계, 개발시험에 관하여 소개하고자 한다.

  • PDF

An examination on proper voltage operation standard for 154kV power system through demand analysis (수요분석을 통한 154kV 계통전압 유지기준 설정)

  • Lee, Ik-Jong;Lee, Sang-Joong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.428-431
    • /
    • 2009
  • KPX sets up the voltage standards according to the voltage level to supply a good quality of electricity to customers. Supply voltages are divided into 4 levels - 345kV, 154kV, 22.9kV, and distribution voltage consisting of 110, 220 and 380V. In this research, we examine the optimal voltage operating level focused on 154kV system that mostly affects electricity quality, through analysing the system demand.

  • PDF

Phase-Shifted Full-Bridge Converter for Welding Power Supply Capable of Using 220 V, 440 V 3-Phase Grid Voltages (220V, 440V 3상 계통전압 혼용이 가능한 용접 전원장치용 위상천이 풀브리지 컨버터)

  • Yun, Duk-Hyeon;Lee, Woo-Seok;Lee, Jun-Young;Lee, Il-Oun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.5
    • /
    • pp.372-375
    • /
    • 2021
  • A three-leg inverter-type isolated DC-DC Converter that can use 220 and 440 V grid input voltages is introduced. The secondary circuit structure of the proposed topology is center-tap, which is the same as the conventional phase-shifted full-bridge converter. However, the primary circuit structure is composed of a three-leg inverter structure and a transformer, in which two primary windings are connected in series. The proposed circuit structure has a wider input voltage range than the conventional phase-shifted full-bridge converter, and the circulating-current on the primary-side is reduced. In addition, the voltage stress at the secondary rectifier is greatly improved, and high efficiency can be achieved at a high input voltage by removing the snubber circuit added to the conventional converter. Prototype converters with input DC of 311 V, output of 622 V, and 50 V and 6 kW class specifications were designed and manufactured to verify the validity of the proposed topology; the experimental results are presented.

Alternating Current Input LED Lighting Control System using Fuzzy Theory

  • Lee, Jae-Kyung;Yim, Jae-Hong
    • Journal of information and communication convergence engineering
    • /
    • v.19 no.4
    • /
    • pp.214-220
    • /
    • 2021
  • In this study, we constructed several scenarios that are required for LED lighting, and we designed and implemented an LED lighting control system to operate these scenarios to confirm their behavior. An LED lighting control system is a hybrid control board that is designed by combining LED controllers and SMPS, consisting of an AC/DC power supply part that converts AC 220 V into DC 12 V, and a drive and control part that controls the scenario and color of the LED module. Conventional LED light controllers have an input power of DC 12 V, so when using the input AC 220 V, the SMPS must be connected to the LED light controller. To eliminate this inconvenience, a hybrid LED lighting control system was configured to combine LED lighting controllers and SMPS into one control system. Furthermore, we designed a control system to represent the most appropriate color according to the input of the distance and illumination using a fuzzy control system to conduct computer simulations.

Development of Friction Welded Al to Cn Bimetallic Sleeve for 220kV XLPE Cable Termination & Joint (220kV XLPE CABLE 접속함용 Al-Cu 이종접속슬리브 개발)

  • Kim, Hyun-Ju;Park, Jeong-Ki;Park, Sung-Min
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.93-93
    • /
    • 2010
  • We developed friction welded bimetallic sleeve for 220kV aluminum conductor XLPE cable. Not only friction welded bimetallic sleeve for Termination(EB-A, EB-G) but also friction welded sleeve for Joint of Al to Cu conductor was developed regardless of this project. Generally, friction welded sleeve used to connect Al conductor cable to Cu conductor cable and used for improvement of mechanical property of terminal by offer the copper side of friction welded bimetallic sleeve at the Termination. Connection method for Al-Cu conductor has mainly used friction welding at the solid state, because it is difficult to connect by using conventional welding method. this investigation introduces development of friction welded bimetallic sleeve by friction welding and test result of 220kV Al conductor XLPE cable and accessories using friction welded sleeve.

  • PDF