• Title/Summary/Keyword: 2002

Search Result 71,038, Processing Time 0.088 seconds

Effect of xylazine hydrochloride on histamine release (Xylazine이 histamine 유리에 미치는 영향)

  • 김영환;박준형
    • Korean Journal of Veterinary Service
    • /
    • v.25 no.1
    • /
    • pp.53-73
    • /
    • 2002
  • It has been reported that degranulation of mast cells in rats, rabbits and dog was observed after dosing xylazine hydrochloride(Xh) which has been widely used as sedative, analgesic and muscular relaxant. Therefore, this experiment was conducted to examine the relations between Xh and histamine release and to identify the action of ${\alpha}$-adrenoceptors which exists on the suface of mast cells. 1. The content of histamine within serum was measured with HPLC by performing the O-phthalaldehyde(OPA) fluorescent derivation. The pretreatment method had a little modification from the conventional method. The pretreament was carried out in the following method. 0.2$m\ell$ of serum and 1$m\ell$ of butanol were added to mixed together and then the liquid was centrifugally separated at 4$^{\circ}C$ and 2,000 rpm for 3 minutes. 0.4$m\ell$ of 0.1N HCl and 1.6$m\ell$ of heptane were added to 0.8$m\ell$ of supernatant taken from the liquid, and they were mixed together. This mixture was also centrifugally separated at 4$^{\circ}C$ and 2,000 rpm for 5 minutes. The supernatant was thrown away and the OPA fluorescent derivation was carried out with 0.2$m\ell$ of the lower liquid then, 5 minutes after mixing 400${\mu}\ell$ of 0.1N HCl, 120${\mu}\ell$ of 1N NaOH and 40${\mu}\ell$ of 0.1% OPA in the 0.2$m\ell$ of the lower liquid,120${\mu}\ell$ of 3.57N H$_3$PO$_4$ was added to the mixed liquid, and the liquid, was mixed again and syringe-filtered. Then, the measurement was done with HPLC in the 30 : 70(ν/ν) ratio of 0.004M KH$_2$PO$_4$: CH$_3$CN, flow rate of 1.0$m\ell$/min., and a wavelength of λex= 350nm and λem=444nm at the column temperature of 27$^{\circ}C$, using the fluorescence detector. 2. The content of histamine in each laboratory animal appeared to be higher in such an order as rabbit, rat, guinea pig, dog, Korean indigenous goat, swine, Korean indigenous cattle, Holstein, and mouse, of which the individual mean values${\pm}$standard deviation were 2.0668 ${\pm}$ 0.6049. 0.4999 ${\pm}$ 0.2278, 0.4241 ${\pm}$ 0.1974, 0.1054 ${\pm}$ 0.0556, 0.1028 ${\pm}$ 0.0276, 0.0972 ${\pm}$ 0.0513, 0.0872 ${\pm}$ 0.0373, 0.0717 ${\pm}$ 0.0379, and 0.0706 ${\pm}$ 0.0366, respectively. 3. The content of histamine was measured at the moments of 15-, 30-, 60-, 120-minutes after inoamuscular injection of 20mg/100kg Xh into two to 4 years old Holstein weighing 600∼700kg. The result showed that there was a significant increase at the times of 30- and 90-minutes after injection(p<0.05). 4. Intramuscular injection of 3mg/10kg Xh was given to crossbred pug dogs weighing 2.5∼4.3kg. The content of histamine was measured at the times of 30-, 60-, 90- and 120-minutes after injection. The result revealed that there was a significant increase at the times of 60-and 90-minutes after injection(p<0.05). 5. Intramuscular injection of 10mg/$m\ell$∼25mg/$m\ell$ Xh in concentration of 0.1$m\ell$ was applied to Korean indigenous goat over 5 months old. Then, the content of histamine was measured at the times of 15-, 30-, 60- and 90-minutes after injection. A significant increase was shown at the times of 30- and 60-minutes after injection(p<0.05). 6. The content of histamine was measured at the moments of 30- and 60-minutes after intramuscular injection of 0.1-0.2$m\ell$ Xh (20mg/$m\ell$) into male rabbits weighting 2.5-4kg. A significant increase was found at the moment of 60 minutes after injection(p<0.001). 7. After administering Xh to the mast cell taken from the abdominal cavity of mouse, the content of histamine was measured. The result showed that the higher the concentration, the more significantly the content of histamine was increased(p<0.05). 8. Compound 48/80 was administered in concentration of 5$\mu\textrm{g}$/$m\ell$ and 10$\mu\textrm{g}$/$m\ell$ to the mast cell picked from the abdominal cavity of mouse. The result showed that there was a significant increase in the content of histamine in case of the concentration of 10$\mu\textrm{g}$/$m\ell$(p<0.05). It was found to be about 10,000 to 500,000 times stronger than the Xh. 9. After premedication of 1mg/kg of yohimbine hydrochloride as ${\alpha}$$_2$-adrenergic antagonist to rabbits, the Xh was administered to them. The result was that the value of histamine within serum was decreased significantly(p<0.001). 10. After premeditation of 1mg/kg of prazosin hydrochloride as ${\alpha}$$_1$-adrenergic antagonist to rabbits, the Xh was administered to them. It was found that the value of histamine within serum was decreased significantly(p<0.005). 11, Prazosin hydrochloride and yohimbine hydrochloride as ${\alpha}$$_1$-adrenergic antagonist, respectively, and ${\alpha}$$_2$-adrenergic antagonist were administerd. In this case, the value of histamine within serum was decreased significantly(p<0.0001). As the results, when the Xh is administered to various kinds of animals, the amount of histamine release within serum is increased. In view of the results so far achieved, it is concluded that Xh acted on both a$_1$-adrenoreceptor and ${\alpha}$$_2$-adrenoreceptor induces the degranulation of mast cell.

Service Quality, Customer Satisfaction and Customer Loyalty of Mobile Communication Industry in China (중국이동통신산업중적복무질량(中国移动通信产业中的服务质量), 고객만의도화고객충성도(顾客满意度和顾客忠诚度))

  • Zhang, Ruijin;Li, Xiangyang;Zhang, Yunchang
    • Journal of Global Scholars of Marketing Science
    • /
    • v.20 no.3
    • /
    • pp.269-277
    • /
    • 2010
  • Previous studies have shown that the most important factor affecting customer loyalty in the service industry is service quality. However, on the subject of whether service quality has a direct or indirect effect on customer loyalty, scholars' views apparently vary. Some studies suggest that service quality has a direct and fundamental influence on customer loyalty (Bai and Liu, 2002). However, others have shown that service quality not only directly affects customer loyalty, it also has an indirect impact on customer loyalty by influencing customer satisfaction and perceived value (Cronin, Brady, and Hult, 2000). Currently, there are few domestic articles that specifically address the relationship between service quality and customer loyalty in the mobile communication industry. Moreover, research has studied customer loyalty as a whole variable, rather than breaking it down further into multiple dimensions. Based on this analysis, this paper summarizes previous study results, establishes an effect mechanism model among service quality, customer satisfaction, and customer loyalty in the mobile communication industry, and presents a statistical test on model assumptions by using customer investigation data from Heilongjiang Mobile Company. It provides theoretical guidance for mobile service management based on the discussion of the hypothesis test results. For data collection, the sample comprised mobile users in Harbin city, and the survey was taken by random sampling. Out of a total of 300 questionnaires, 276 (92.9%) were recovered. After excluding invalid questionnaires, 249 remained, for an effective rate of 82.6 percent for the study. Cronbach's ${\alpha}$ coefficient was adapted to assess the scale reliability, and validity testing was conducted on the questionnaire from three aspects: content validity, construct validity. and convergent validity. The study tested for goodness of fit mainly from the absolute and relative fit indexes. From the hypothesis testing results, overall, four assumptions have not been supported. The ultimate affective relationship of service quality, customer satisfaction, and customer loyalty is demonstrated in Figure 2. On the whole, the service quality of the communication industry not only has a direct positive significant effect on customer loyalty, it also has an indirect positive significant effect on customer loyalty through service quality; the affective mechanism and extent of customer loyalty are different, and are influenced by each dimension of service quality. This study used the questionnaires of existing literature from home and abroad and tested them in empirical research, with all questions adapted to seven-point Likert scales. With the SERVQUAL scale of Parasuraman, Zeithaml, and Berry (1988), or PZB, as a reference point, service quality was divided into five dimensions-tangibility, reliability, responsiveness, assurance, and empathy-and the questions were simplified down to nineteen. The measurement of customer satisfaction was based mainly on Fornell (1992) and Wang and Han (2003), ending up with four questions. Based on the study’s three indicators of price tolerance, first choice, and complaint reaction were used to measure attitudinal loyalty, while repurchase intention, recommendation, and reputation measured behavioral loyalty. The collection and collation of literature data produced a model of the relationship among service quality, customer satisfaction, and customer loyalty in mobile communications, and China Mobile in the city of Harbin in Heilongjiang province was used for conducting an empirical test of the model and obtaining some useful conclusions. First, service quality in mobile communication is formed by the five factors mentioned earlier: tangibility, reliability, responsiveness, assurance, and empathy. On the basis of PZB SERVQUAL, the study designed a measurement scale of service quality for the mobile communications industry, and obtained these five factors through exploratory factor analysis. The factors fit basically with the five elements, indicating the concept of five elements of service quality for the mobile communications industry. Second, service quality in mobile communications has both direct and indirect positive effects on attitudinal loyalty, with the indirect effect being produced through the intermediary variable, customer satisfaction. There are also both direct and indirect positive effects on behavioral loyalty, with the indirect effect produced through two intermediary variables: customer satisfaction and attitudinal loyalty. This shows that better service quality and higher customer satisfaction will activate the attitudinal to service providers more active and show loyalty to service providers much easier. In addition, the effect mechanism of all dimensions of service quality on all dimensions of customer loyalty is different. Third, customer satisfaction plays a significant intermediary role among service quality and attitudinal and behavioral loyalty, indicating that improving service quality can boost customer satisfaction and make it easier for satisfied customers to become loyal customers. Moreover, attitudinal loyalty plays a significant intermediary role between service quality and behavioral loyalty, indicating that only attitudinally and behaviorally loyal customers are truly loyal customers. The research conclusions have some indications for Chinese telecom operators and others to upgrade their service quality. Two limitations to the study are also mentioned. First, all data were collected in the Heilongjiang area, so there might be a common method bias that skews the results. Second, the discussion addresses the relationship between service quality and customer loyalty, setting customer satisfaction as mediator, but does not consider other factors, like customer value and consumer features, This research will be continued in the future.

A Study of the Health Service Computerization State and the Occupational Nurses's Satisfaction Level on Computerization (산업간호현장의 보건업무 전산화시스템 활용현황과 산업간호사의 전산화 직무만족도 연구)

  • Jung, Hee Young;Park, Hyoung-Sook
    • Korean Journal of Occupational Health Nursing
    • /
    • v.13 no.1
    • /
    • pp.5-18
    • /
    • 2004
  • This study aims to investigate the use state of the health service computerization system in the occupational nursing field and the occupational nursers' satisfaction level, and provide basic data to promote the development of the health service computerization system for the nursing field. For this study, a questionnaire was provided to 118 occupational nurses who belong to Busan and Gyeongnam branches of KAOHN(Korean Association of Occupational Health Nurses) for 2 months (from Dec. 1, 2002 to Jan. 31, 2003). A tool of Choi Yong-Heui(2000) was used to investigate the satisfaction level of using the health service computerization system. The collected materials were analyzed in real number and percentage, average and standard deviation, t-test and ANOVA by using the SPSS WIN 10.0 program. This study is summarized as follows: 1. The average age was $31.99{\pm}5.58$ old in this study. The married were 54.2%. Participants who graduated from a junior college was 76.9%. The average service period was $4.48{\pm}4.68$ years. In service types, 79.7% of participants served in a health care center. The average service period was $3.22{\pm}2.89$ years. The service place which had 1000 workers or more was 35.6%. 2. Only 20.3% of participants in this study had a computer use education. 3. The field who participants used mostly was communication/internet, $3.29{\pm}.85$ hours in average. 4. 97.1% of occupational fields had computers and peripheral devices: 71.4% in pentium computer, 42.8% in the hard disk capacity of 20-29GB, 60.0% in 15 inch monitors, 86.2% in printers, 18.1% in digital cameras, 12.4% in LAN, and 9.5% in scanners. 80.1% of the occupational fields which were objects of study could use communication. 5. The occupational fields which did not introduced the health service computerization system were 62.8%. The main cause was attributable to entrepreneurs' insufficient recognition 66.6%. 51.5% of the entrepreneurs did not have an introduction plan. 37.2% of participating companies had the health service computerization system. 56.4% of them introduced it since the year 2000. 81.6% of the introduction motivation aimed to the efficiency of health service. The most issue upon introduction was insufficient understanding of a person in charge - 25.6%. The in-house development of the system covered 56.4%. 61.5% of the participants accepted their demands from the first stage of development. The direct effect of computerization showed the increase of 25.9% in the quickness and continuity of service treatment, and 25.9% in the serviceability of statistical treatment. 6. 22.0% of the participants had a computerization system use education. 69.2% of them had a in-house education. An educational method by nurses who used the computerization system was 76.9%. 92.3% of the education was helpful for practical duties. 7. An analysis of the computer use by health service fields showed that the medicine management in a health management field was 15.9%. the work environment measuring management in a work environment filed was 32.9%. the employment. general and special examination management in a heal th management field was 61.1 %. the various reports management in an administrative field was 64%. the health education data preparation management in an educational field was 58.0%. and the medicine and expendables management in an equipment management field was 51.6%. An analysis of the computerization system use showed that the various statistical data manage in a health management field was 13.0%. the work environment measuring management in a health management field was 34.8%. the personal disease management in a health management field was 51.9%. the heal education data preparation management in an educational field was 54.5%. and the equipment management of health care centers in an equipment management field was 52.6%. 8. 31.6% of the participants wanted that health service computerization system would include the generals of health services. 42.4% of the participants thought that first of all. the aggressive interest and investment of employers were required to build the health service computerization system. 9. The participants' satisfaction level on the computerization system use was $3.51{\pm}.57$ points. An analysis by each factor showed $3.62{\pm}.68$ points in a service change factor. $3.15{\pm}.63$ points in a computer program use factor, and $3.45{\pm}.71$ points in a continuous computerization use factor. 10. An analysis of the computerization system use by general characteristics of participants showed that the married (p = .022) had the satisfaction level higher than the unmarried. 11. The satisfaction level of the computerization system use by participants' computer use ability tended to be higher in proportion to the increase of computer use abilities in spreadsheet (F=2.606. p=.048). presentation (F=3.62. p=.012) and communication/internet(F=2.885. p=.0321. Based on the study results mentioned above. I will suggest as follows : The nationwide enlargement and repetition study is required for occupational nurses who serve in occupational nursing fields. The computerization system in a health service field is inferior comparing with other fields. The computerization system standard by business types and characteristics should be prepared through employers's aggressive participation and national support. Therefore various statistical data which occurs in occupational fields will be managed systematically and efficiently. A regular and systematic computer education plan for occupational nurses in charge of health services in the filed is urgently required to efficiently manage and improve the health of on-site workers.

  • PDF

Relationships between inbreeding coefficient and economic traits in inbred line of Duroc pigs (두록 계통조성 집단의 근교수준이 경제형질에 미치는 영향)

  • song, Na-Rae;Kim, Yong-Min;Kim, Doo-Wan;Sa, Soo-Jin;Kim, Ki-Hyun;Kim, Young-Hwa;Cho, Kyu-Ho;Do, Chang-hee;Hong, Joon-Ki
    • Korean Journal of Agricultural Science
    • /
    • v.42 no.2
    • /
    • pp.141-149
    • /
    • 2015
  • The data of Duroc swine species that were born from 2000 to 2014 excluding missing ones collected by Korea National Institute of Animal Science were used in the present study. After removing missing data we used 9756 of productions data and 1728 of reproductive reference of breeding research to study the level of inbreeding and to investigate the impact on the reproductive traits, production traits. The correlation of reproductive traits and inbreeding coefficient are -0.07, -0.08 for total number pigs born, number of pigs born alive respectively and birth weight per litter is -0.10, number of pigs born alive per litter to 21days is -0.06 and body weight per litter to 21days is -0.09. The correlation coefficients of the inbreeding coefficients of reproductive traits are shown within 10% with negative correlation (P < 0.05). Days of 90kg and Backfat in the correlation coefficient and inbreeding coefficient production traits were not observed significant correlations, Average daily gain was investigated by the positive correlation of 0.05. According to the above results, the inbreeding level gave a negative effect on the improvement of the breed traits, investigating a relatively high compared to a negative effect on other traits. But overall correlation degree is less than 10% was observed. This inbreeding coefficient has not been clearly observed due to degeneration of the average inbreeding coefficients of these generations was maintained within 10% of the population. The scale of the experimental group was about 150 degree pig husbandry is very small compared to the advanced countries. However, the level of inbreeding in the population group with the appropriate mating combinations is maintained below 10% of population is thought to be small and can minimize the effects of inbreeding degeneration. further testing utilizing this selection is constantly considered to be necessary.

Effect of Cassia tora L. Powder Added-Diets on the Accumulation of Cadmium in Rat (결명자 첨가식이가 흰쥐의 체내 카드뮴 축적에 미치는 영향)

  • 김성조;백승화;허종욱;김운성;이주돈;강경원;박성혜;한종현;정성윤
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.12 no.6
    • /
    • pp.554-565
    • /
    • 2002
  • The purpose of this study is to investigate the effect of raw Cassia tora L. powder added-diets on reducing cadmium accumulation in rats. The experimental animals were Sprague-Dawley family(♂, 4 weeks) which was classified into normal group CN, compared group CS, Cd-added group Cl and groups C2, C3, C4 in which 0.5, 1.0 and 1.5% of the Cassia tora L. powder are added, respectively. The growth rate and food efficiency ratio, and the amounts of accumulated cadmium in rats for S weeks were measured and analyzed. The results are as follows; 1. The rates of weight gain decreased in the order of C3>C2>C4>Cn>Cs>Cl groups, and Cl group to which only cadmium water had been fed was the lowest among them. The correlation between groups Cl and C3 was significantly different at the 1% level. 2. Food efficiency ratio(FER) decreased in the order of C3>C2>Cs>Cn>C4>Cl, and the FERs of C3, C2, CS, CN and C4 are greater than that of Cl by 22.87, 19.59, 18.54, 14.20 and 13.17%, respectively. 3. As for the Cassia tora L. powder-added groups, the amounts of cadmium accumulated in organs and tissues, that is, the brain, heart, spleen, liver, lungs, testicles. kidney, femoral muscle and leg bones were 0.45 $\pm$ 0.04 to 0.83$\pm$0.04, 1.68$\pm$0.02 to 2.16$\pm$0.02, 3.26$\pm$0.05 to 4.62$\pm$0.27, 37.52$\pm$0.09 to 47.71$\pm$0.73, 1.07$\pm$0.10 to 1.66$\pm$0.04, 1.04$\pm$0.06 to 1.24$\pm$0.08, 36.79$\pm$0.20 to 39.61 $\pm$0.53, 0.87$\pm$0.02 to 1.00$\pm$0.02 and 0.65$\pm$0.17 to 1.27 $\pm$ 0.06 $\mu\textrm{g}$/g, respectively. 4. The accumulated Cd content for C4 was the lowest among Cassia tora L. powder-added groups. When the results for C4 are compared with those for Cl, it is observed that each cadmium content accumulated in the brain, heart spleen, liver, lungs, testicles, kidney. femoral muscle and leg bones is dropped by 49.03, 22.56, 36.02, 35.75, 41.75, 36.20, 37.00, 22.77 and 56.67 %, respectively. On the other hand. the accumulated Cd content increased in the order of brain

  • PDF

Evaluation of Parameters of Gas Exchange During Partial Liquid Ventilation in Normal Rabbit Lung (토끼의 정상 폐 모델에서 부분액체환기 시 가스교환에 영향을 주는 인자들에 대한 연구)

  • An, Chang-Hyeok;Koh, Young-Min;Park, Chong-Wung;Suh, Gee-Young;Koh, Won-Jung;Lim, Sung-Yong;Kim, Cheol-Hong;Ahn, Young-Mee;Chung, Man-Pyo;Kim, Ho-Joong;Kwon, O-Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.1
    • /
    • pp.14-23
    • /
    • 2002
  • Background: The opitmal ventilator setting during partial liquid ventilation(PLV) is controversial. This study investigated the effects of various gas exchange parameters during PLV in normal rabbit lungs in order to aid in the development of an optimal ventilator setting during PLV. Methods: Seven New-Zealand white rabbits were ventilated in pressure-controlled mode with the following settings; tidal volume($V_T$) 8 mL/kg, positive end-expiratory pressure(PEEP) 4 $cmH_2O$, inspiratory-to-expiratory ratio(I:E ratio) 1:2, fraction of inspired oxygen($F_TO_2$) 1.0. The respiration rate(RR) was adjusted to keep $PaCO_2$ between 35~45 mmHg. The ventilator settings were changed every 30 min in the following sequence : (1) Baseline, as the basal ventilator setting, (2) Inverse ratio, I:E ratio 2:1, (3) high PEEP, adjust PEEP to achieve the same mean inspiratory pressure (MIP) as in the inverse ratio, (4) High $V_T$, $V_T$ 15 mL/kg, (5) high RR, the same minute ventilation (MV) as in the High $V_T$. Subsequently, the same protocol was repeated after instilling 18 mL/kg of perfluorodecalin for PLV. The parameters of gas exchange, lung mechanics, and hemodynamics were examined. Results: (1) The gas ventilation(GV) group showed no significant changes in the $PaO_2$ at all phases. The $PaCO_2$ was lower and the pH was higher at the high $V_T$ and high RR phases(p<0.05). No significant changes in the lung mechanics and hemodynamics parameters were observed. (2) The baseline $PaO_2$ for the PLV was $312{\pm}$ mmHg. This was significantly lower when decreased compared to the baseline $PaO_2$ for GV which was $504{\pm}81$ mmHg(p=0.001). During PLV, the $PaO_2$, was significantly higher at the high PEEP($452{\pm}38$ mmHg) and high $V_T$ ($461{\pm}53$ mmHg) phases compared with the baseline phase. However, it did not change significantly during the inverse I:E ratio or the high RR phases. (3) The $PaCO_2$ was significantly lower at high $V_T$ and RR phases for both the GV and PLV. During the PLV, $PaCO_2$ were significantly higher compared to the GV (p<0.05). (4) There were no important or significant changes in of baseline and high RR phases lung mechanics and hemodynamics parameters during the PLV. Conclusion: During PLV in the normal lung, adequate $V_T$ and PEEP are important for optimal oxygenation.

Clinical Impact of Bronchial Reactivity and Its Relationship with Changes of Pulmonary Function After Asthmatic Attack Induced by Methacholine (기관지 반응성의 임상적 의의 및 메타콜린으로 유도된 천식 발작시 폐기능 변화와의 관계)

  • Ryu, Yon-Ju;Choi, Young-Ju;Kwak, Jae-Jin;Lee, Ji-A;Nam, Seung-Hyun;Park, Chang-Han;Chaon, Saon-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.1
    • /
    • pp.24-36
    • /
    • 2002
  • Background: Bronchial reactivity is known to be a component of airway hyperresponsiveness, a cardinal feature of asthma, with bronchial sensitivity, and is increments in response to induced doses of bronchoconstrictors as manifested by the steepest slope of the dose-response curve. However, there is some controversy regarding methods of measuring bronchial reactivity and clinical impact of such measurements. The purpose of this study was to evaluate the clinical significance and assess the clinical use by analyzing the relationship of the bronchial sensitivity, the clinical severity and the changes in pulmonary function with bronchial reactivity. Method: A total of 116 subjects underwent a methacholine bronchial provocation test. They were divided into 3 groups : mild intermittent, mild persistent, moderate and cough asthma. Severe patients were excluded. Methacholine PC20 was determined from the log dose-response curve and PC40 was determined by one more dose inhalation after PC20. The steepest slope of log dose-response curve, connecting PC20 with PC40, was used to calculate the bronchial reactivity. Body plethysmography and a single breath for the DLCO were done in 43 subjects before and after methacholine test. Results: The average bronchial reactivity was 38.0 in the mild intermittent group, 49.8 in the mild persistent group, 61.0 in the moderate group, and 41.1 in the cough asthma group. There was a weak negative correlation between PC20 and bronchial reactivity. A heightened bronchial reactivity tends to produce an increased clinical severity in patients with a similar bronchial sensitivity and basal spirometric pulmonary function. There were significant correlations between the bronchial reactivity and the initial pulmonary function before the methacholine test in the order of sGaw, Raw, $FEV_1$/FVC, MMFR. There were no correlations between the bronchial sensitivity and the % change in the pulmonary function parameters after the methacholine test. However, there were significant correlations between the bronchial reactivity and the PEF, $FEV_1$, DLCO. Conclusion: There was weak significant negative correlation between the bronchial reactivity and the bronchial sensitivity, and the bronchial reactivity closely reflected the severity of the asthma. Accordingly, measuring both the bronchial sensitivity and the bronchial reactivity can be of assistance in assessing of the ongoing disease severity and in monitoring the effect of therapy.

DC Resistivity method to image the underground structure beneath river or lake bottom (하저 지반특성 규명을 위한 전기비저항 탐사)

  • Kim Jung-Ho;Yi Myeong-Jong;Song Yoonho;Cho Seong-Jun;Lee Seong-Kon;Son Jeongsul
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.139-162
    • /
    • 2002
  • Since weak zones or geological lineaments are likely to be eroded, weak zones may develop beneath rivers, and a careful evaluation of ground condition is important to construct structures passing through a river. Dc resistivity surveys, however, have seldomly applied to the investigation of water-covered area, possibly because of difficulties in data aquisition and interpretation. The data aquisition having high quality may be the most important factor, and is more difficult than that in land survey, due to the water layer overlying the underground structure to be imaged. Through the numerical modeling and the analysis of case histories, we studied the method of resistivity survey at the water-covered area, starting from the characteristics of measured data, via data acquisition method, to the interpretation method. We unfolded our discussion according to the installed locations of electrodes, ie., floating them on the water surface, and installing at the water bottom, since the methods of data acquisition and interpretation vary depending on the electrode location. Through this study, we could confirm that the dc resistivity method can provide the fairly reasonable subsurface images. It was also shown that installing electrodes at the water bottom can give the subsurface image with much higher resolution than floating them on the water surface. Since the data acquired at the water-covered area have much lower sensitivity to the underground structure than those at the land, and can be contaminated by the higher noise, such as streaming potential, it would be very important to select the acquisition method and electrode array being able to provide the higher signal-to-noise ratio data as well as the high resolving power. The method installing electrodes at the water bottom is suitable to the detailed survey because of much higher resolving power, whereas the method floating them, especially streamer dc resistivity survey, is to the reconnaissance survey owing of very high speed of field work.

  • PDF

Lipid Contents Characteristics of Gene Accumulate in Rice (벼 유전자 집적에 따른 지질함량 특성)

  • 윤경민;홍순관
    • Korean Journal of Plant Resources
    • /
    • v.15 no.3
    • /
    • pp.177-187
    • /
    • 2002
  • In our experiment, selected mutants were used which showed not only the phenotype of a specific unpolished rice but also phenotypes of EM 40, LO 1050, and TAL 214. Reciprocal crosses between the mutants were conducted to select strains which would have more quantity of lipids than before. The constitution of fatty acid was also tested to figure out nutritional aspects of the mutants. In the crossing between EM 40 mutants and mutants (LO 1050) having a thick aleurone layer, the expression of EM 40 mutants has no relation with the thickness of the aleurone layer. And the lipid content of new F$_2$ strains through the crossing is 4.15 %. The lipid content is larger than those of the parents including Kinmaze and in other crossings of this experiment. This is attributed to the fact that the new F$_2$ strains are the products of the crossing between genes responsible for the size of buds, where lipid is accumulated, and genes accountable for the thickness of the aleurone layer. In the crossing between EM 40 mutants and TAL 214 mutants, lipid content of the new F$_2$ strains is 3.8 %, higher than 2.92 % of TAL 214 mutants. But the degree of lipid increase is smaller than in two other crossings. This is probably because genes expressing the phenotypes of TAL 214 affect the size of EM 40, which gets smaller. The aleurone layer of the new F$_2$ strains is 12 $\mu\textrm{m}$ thicker than the layer of TAL 214 mutants, but 6 $\mu\textrm{m}$ thinner than that of parents (LO 1050) having a thick aleurone layer. This seems to be affected by the size of a microscope. The phenotype of the new F$_2$ strains appears to be similar to that of TAL 214. The lipid content of the new F$_2$ strains is 3.85 %, larger than 2.92 % of TAL 214 and 3.01 % of LO 1050. The increase may be due to the aleurone layer of LO 1050. And the size of the bud of the unpolished rice, though it is not big enough like that of LO 1050, seems to be affected by the accumulation of genes in the thick aleurone layer. The accumulation may contribute to the increase in the content of lipid. When it comes to the constitution of fatty acid, there is little difference between parents like Kinmaze and the new F$_2$ strains. But oleic acid increases while linoleic acid decreases. And the decrease in the linolenic acid seems to contribute to the increase in lipid content. This fact also raises the possibility that genes accountable for specific phenotypes could change the quality of rice if the genes are accumulated. Now, experiments on strains which have large lipid content in EM 40 type 1(ge-1, 3.68 %), EM type 2(ge-2, 2.91 %), thick aleurone layer(4.63 %), and starch layer(3.44 %) are under way to figure out the effects of gene accumulation. These experiments are likely to present the ways for increasing the lipid content.

Difference of Short Term Survival in Patients with ARDS According to Responsiveness to Alveolar Recruitment (급성호흡곤란증후군 환자에서 폐포모집술의 반응에 따른 초기 예후의 차이)

  • Kim, Ho Cheol;Cho, Dae Hyun;Kang, Gyoung Woo;Park, Dong Jun;Lee, Jong Deok;Hwang, Young Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.3
    • /
    • pp.280-288
    • /
    • 2004
  • Background : Lung protective strategies, using low tidal volume in ARDS, improve survival rate in ARDS. However, low tidal volume ventilation may promote alveolar de-recruitment. Therefore, alveolar recruitment is necessary to maintain arterial oxygenation and to prevent repetitive opening and closure of collapsed alveoli in lung protective strategies. There has been a recent report describing improvement in arterial oxygenation with use of recruitment maneuver. However, impact of recruitment on outcome of ARDS is unknown. We evaluated whether short-term survival difference existed in patients with ARDS, who were performed alveolar recruitment maneuver(ARM) and prone position, according to response of alveolar recruitment or not. Methods : All patients who were diagnosed with ADRS and received mechanical ventilation were included. ARM were sustained inflation($35-45cmH_2O$ CPAP for 30-40 sec.) or increasing level of PEEP. If these methods were ineffective, alveolar recruitment with prone position was done for at least 10 hours. $P_aO_2/FiO_2$(P/F) ratio was determined before and at 0.5 and 2 hours after ARM. We defined a responder if the P/F ratio was increased over 50% of baseline value. We compared 10-days and 30-days survival rate between responders and non-responders. Results : 20 patients(M:F=12:8, $63{\pm}14age$) were included. Among them, 12 patients were responders and 8 patients were non-responders. In responders, P/F ratio was increased from $92{\pm}25mmHg$ to $244{\pm}85mmHg$. In non-responders, P/F ratio increased from $138{\pm}37mmHg$ to $163{\pm}60mmHg$. Among non-responders, P/F ratio was improved over 50% in 2 patients after prone position. Overall, 14 patients were responders after ARM and prone position. The 10-days and 30-days survival rate in responders was significantly higher than in non-responders(86%, 57% in responders and 33%, 0% in non-responders)(p<0.05). There was no significant difference between responders and non-responders in age($71{\pm}11$, $60{\pm}14$), lung injury score($2.8{\pm}0.2$, $2.9{\pm}0.45$), simplified acute physiology score(SAPS) II ($35{\pm}4.6$, $34{\pm}5.7$), positive end-positive pressure level($15.6{\pm}1.9cmH_2O$, $14.5{\pm}2.1cmH_2O$). Conclusion : ARM may improve arterial oxygenation in some patients with ARDS. These responders in patients with ARDS showed significant higher 10-days and 30-days survival rate than non-responders patients with alveolar recruitment.