• 제목/요약/키워드: 2-probe method

검색결과 757건 처리시간 0.026초

Effects of Position of Auxiliary Probe on Ground Resistance Measurement Using Fall-of-Potential Method

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon
    • International Journal of Safety
    • /
    • 제7권2호
    • /
    • pp.1-6
    • /
    • 2008
  • In this paper, the effects of the position and the angle of the potential probes on the measurements of the ground resistance using the fall-of-potential method are described and the testing techniques for minimizing the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and angle of auxiliary probes. In order to analyze the relative error in the measured value of the ground resistance due to the position of the potential probe, the ground resistance was measured for the case in which the distance of the current probe was fixed at 50[m] and the distance of the potential probe was located from 10[m] to 50[m]. Also, the potential probe was located in turn at $30[^{\circ}]$, $45[^{\circ}]$, $60[^{\circ}]$, $90[^{\circ}]$, and $180[^{\circ}]$. As a consequence, relative error decreased with increasing distance of the potential probe and decreasing angle between the current probe and potential probe. The results could help to determine the position of the potential probe during the ground resistance measurement.

영역분할과 2차원 커브피팅 함수들을 이용하는 직선형 5공 압력프로브의 성능 평가 (The Performance Assessment of a Straight-Type Five-Hole Pressure Probe Using a Zone Partition and Two-Dimensional Curve-Fitting Functions)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제18권1호
    • /
    • pp.22-31
    • /
    • 2014
  • This paper introduced the new calibration algorithm of a straight-type five-hole pressure probe necessary for calculating three-dimensional flow velocity components. The new velocity data reduction method using both a commercial two-dimensional curve-fitting program and the zone partition method of a calibration map was firstly introduced in this study. This new calibration method can be applied up to the wide flow angle of ${\pm}80^{\circ}$ despite of using a five-hole pressure probe because this data reduction method showed a comparatively good performance in calculating yaw and pitch angles from the calibration map.

Development of a Handheld Sheet Resistance Meter with the Dual-configuration Four-point Probe Method

  • Kang, Jeon-Hong;Lee, Sang-Hwa;Yu, Kwang-Min
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1314-1319
    • /
    • 2017
  • A handheld sheet resistance meter that can easily and quickly measure the sheet resistance of indium tin oxide films was developed. The dual-configuration four-point probe method was adopted for this instrument, which measured sheet resistance in the range from $0.26{\Omega}/sq$. to $2.6k{\Omega}/sq$. with 0.3 % ~ 0.5 % uncertainty. The screen of the instrument displayed the sheet resistance when the probe was in contact with the sample surface and the value continued to be displayed during the probe contact. Even after separating the probe from the surface, the value was still displayed on the screen and could be read easily. A feature of the instrument was the use of the dual-configuration technique to reduce edge effects markedly compared with the single-configuration technique and its ease of operation without applying correction factors for sample size and thickness.

The Capacity of Applying Electrical Resistance Probe in Natural Corrosion Tests of Vietnam

  • Pham, Thy San;Le, Thi Hong Lien;Le, Quoc Hung
    • Corrosion Science and Technology
    • /
    • 제2권2호
    • /
    • pp.98-101
    • /
    • 2003
  • The Electrical Resistance Probe of carbon steel and weight loss coupons were exposed in atmosphere and in the lake water of Hanoi. The comparison of data received by two methods after one year exposure was presented. The correspondence of the data of these methods on the exposure time in both environments showed a capacity of using Electrical Resistance Probe in Vietnamese natural corrosion testing of Carbon steel.

접촉감지프로브를 이용한 자유곡면의 삼차원형상 자동측정 (Automatic Measurement of 3-Dimensional Profile of Free-Formed Surfaces by Using Touch-Trigger Probes)

  • 송창규
    • 대한기계학회논문집
    • /
    • 제17권2호
    • /
    • pp.407-415
    • /
    • 1993
  • This report presents an automatic measurement method of 3-dimensional profiles of free-formed surfaces, by using a touch a touch-trigger contact probe along with a conventional coordinate measuring machine. The method proceeds in three steps; The surface profile under consideration is traced by the probe in an automatic manner, and then its measured data is compensated by considering the actual probe radius. Finally the compensated data is rearranged in the form suitable for the further processings of CAD/CAM applications. Some experimental results are discussed to verify the validity of the method suggested in this study.

초음파회절방법(超音波回折方法)을 이용한 귀렬(龜裂)의 높이 측정(測定) (Measurement of the Crack Height using the Two-Probe Ultrasonic Diffraction Method.)

  • 이재옥;이승규;김영길
    • 비파괴검사학회지
    • /
    • 제7권2호
    • /
    • pp.35-41
    • /
    • 1988
  • The optimum test conditions of measuring the crack height were determined for the two-probe ultrasonic diffraction method. The applicability and the accuracy of the two-probe ultrasonic diffraction method on the inclined artificial cracks and the fatigue cracks were evaluated. It us possible to measure the height of the normal and inclined artificial cracks with the maximum error of ${\pm}\;0.5mm$ with the two-probe ultrasonic diffraction method. It was found, however, that the accuracy of this method in meaasuring the height of the fatigue crack depends on the degree of closure of the crack tip. It was desirable to choose a refraction angle as small as possible, but the angle should not be so small that the distortion of the lateral waveform became appreciable.

  • PDF

Drug-Biomacromolecule Interaction XII: Comparative binding study of sulfaethidole to bovine serum albumin by equilibrium dialysis, fluorescence probe technique, uv difference spectrophotometry and circular dichroism

  • Kim, Chong-Kook;Chun, Yang-Sook;Lah, Woon-Lyong
    • Archives of Pharmacal Research
    • /
    • 제12권3호
    • /
    • pp.160-165
    • /
    • 1989
  • Binding of sulfaethidole to bovine serum albumin was studied by equilibrium dialysis, fluorescence probe technique, uv difference spectrophotometry and circular dichroism. Equilibrium dialysis method enabled us to estimate the total number of drug binding sites of albumin molecule. For sulfaethidole, albumin had 6 primary and 40 secondary binding sites. The primary and secondary binding constants were 0.9 * 10/sup 5/ M/sup -1/ and 0.2 * 10/sup 6/ M/sup -1/, respectivitely. 1-Anilino-8-naphthalenesulfonate (ANS) and 2-(4-hydroxylbenzeneazo)- benzoic acid (HBAB) were used as the fluorescence probe and the uv spectrophotometric probe, respectively. In fluorescence probe technique, results indicated that the number of higher affinity drug binding site of albumin was 1 and the number of lower affinity drug binding sites of albumin was 3, and the primary and secondary drug binding constants for bovine serum albumin were 2.15 * 10/sup 5/M/sup -1/ and 1.04 * 10/sup 5/ M/sup -1/, respectively. In uv difference spectrophotometry, binding sites were 3 and binding constant was 1.88 * 10/sup 5/M/sup -1/. The above spectrophotometry, binding sites were 3 and binding constant was 1.88 * 10/sup 5/M/sup -1/. The above results suggest that several different methods should be used in ompensation for insufficient information about drug binding to albumin molecule given by only one method.

  • PDF

Real-time PCR을 이용한 돼지써코바이러스 감염증 진단법 연구 (Rapid detection and quantification of porcine circovirus type 2 (PCV 2) DNA in Real-time PCR)

  • 김은경;황보원;이종민;손병국;박호정;김도경
    • 한국동물위생학회지
    • /
    • 제32권4호
    • /
    • pp.299-306
    • /
    • 2009
  • Assay for the detection and quantification of porcine circovirus type 2 (PCV 2) with the real-time PCR were developed. TaqMan probe real-time using a set of primer/probe was developed for detection of PCV 2. In this study we applied real-time PCR assay to 320 samples, collected from pig farms. In 151 of 320 samples, PCV 2 DNA was detected by conventional PCR assay. All samples positive for PCV 2 DNA in conventional PCR assay were also positive in Real-time PCR assay, but 69 of 169 samples that tested negative for PCV 2 DNA in conventional assay were tested positive in TaqMan probe real-time PCR assay. The test of TaqMan probe real-time PCR resulted in detection and quantification limits of 101 copies per sample. TaqMan probe real-time PCR assay increased the number of samples in which PCV 2 was detected by 21%. TaqMan probe real-time PCR assay is very efficient method in contrast to the conventinal PCR, becoming increasingly important method for gene analysis.

이중탐침법을 이용한 수평형 지중열교환기 뒤채움재의 열확산계수 측정 (Thermal Diffusivity Measurement of Backfilling Materials for Horizontal Ground Heat Exchanger Using Dual-Probe Method)

  • 손병후;최항석
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권2호
    • /
    • pp.51-59
    • /
    • 2011
  • Storage and transfer heat in soils are governed by the soil thermal properties and these properties are therefore needed in many engineering applications, including horizontal ground heat exchanger for ground-coupled heat pumps. This paper presents the measured results of the thermal diffusivity of soils(silica, quartzite, limestone, sandstone, and masonry soils) used for the trench backfilling materials of the horizontal ground heat exchanger. To assess this thermal property, we (i) measure the soil thermal conductivities and volumetric heat capacities using dual-probe method and (ii) compare the estimates from the de Vries method of summing the heat capacities of the soil constituents. The results show that the thermal diffusivity tends to increase as dry soil begins to wet, but it approaches a constant value or even decreases as the soil continues to wet. Measurements made by using the dual-probe method agreed well with independent estimates obtained using the single-probe method.

Pi29-L DNA 프로브를 이용한 Prevotella intermedia ATCC 25611의 동정 (Identification of Prevotella intermedia ATCC 25611 Using Pi29-L DNA Probe.)

  • 국중기;백동헌
    • 한국미생물·생명공학회지
    • /
    • 제31권2호
    • /
    • pp.205-209
    • /
    • 2003
  • Recently, we introduced a new method for rapid screening of bacterial species- or subspecies-specific DNA probes, named “inverted dot blot hybridization screening method”. We then applied this method to develop species- or strain- specific DNA probes for Prevotella intermedia and Prevotella nigrescens. In those studies, among 96 candidate DNA probes which were screened by the new method, 5 probes were confirmed as being putatively strain-specific : 3 probes for P. nigrescens 9336 (ATCC 33563), one for each p. intermedia ATCC 25611 and one for P. nigrescens G8-9K-3 (ATCC 49046). In the present study, we evaluated by Southern blot analysis a DNA probe Pi29-L, one of the 96 candidate probes described above, whether it is specific for the strain ATCC 25611 off. intermedia. Our data show that the probe Pi29-L is potentially P. intermedia ATCC 25611-specific, which can be useful for the detection and identification of the strain, particularly in maintenance of the strain.