• Title/Summary/Keyword: 2-deoxy-D-glucose

Search Result 105, Processing Time 0.022 seconds

An Assessment of the Accuracy of 3 Dimensional Acquisition in F-18 fluorodeoxyglucose Brain PET Imaging (3차원 데이터획득 뇌 FDG-PET의 정확도 평가)

  • Lee, Jeong-Rim;Choi, Yong;Kim, Sang-Eun;Lee, Kyung-Han;Kim, Byung-Tae;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Seong-Wun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.327-336
    • /
    • 1999
  • Purpose: To assess the quantitative accuracy and the clinical utility of 3D volumetric PET imaging with FDG in brain studies, 24 patients with various neurological disorders were studied. Materials and Methods: Each patient was injected with 370 MBq of 2-[$^{18}F$]fluoro-2-deoxy-D-glucose. After a 30 min uptake period, the patients were imaged for 30 min in 2 dimensional acquisition (2D) and subsequently for 10 min in 3 dimensional acquisition imaging (3D) using a GE $Advance^{TM}$ PET system, The scatter corrected 3D (3D SC) and non scatter-corrected 3D images were compared with 2D images by applying ROIs on gray and white matter, lesion and contralateral normal areas. Measured and calculated attenuation correction methods for emission images were compared to get the maximum advantage of high sensitivity of 3D acquisition. Results: When normalized to the contrast of 2D images, the contrasts of gray to white matter were $0.75{\pm}0.13$ (3D) and $0.95{\pm}0.12$ (3D SC). The contrasts of normal area to lesion were $0.83{\pm}0.05$ (3D) and $0.96{\pm}0.05$ (3D SC). Three nuclear medicine physicians judged 3D SC images to be superior to the 2D with regards to resolution and noise. Regional counts of calculated attenuation correction was not significantly different to that of measured attenuation correction. Conclusion: 3D PET images with the scatter correction in FDG brain studies provide quantitatively and qualitatively similar images to 2D and can be utilized in a routine clinical setting to reduce scanning time and patient motion artifacts.

  • PDF

Improved Radiochemical Yields, Reliability and Improvement of Domestic $^{18}F$-FDG Auto Synthesizer (국산 $^{18}F$-FDG Auto Sysnthesizer의 수율 향상과 성능 개선)

  • Park, Jun-Hyung;Im, Ki-Seop;Lee, Hong-Jin;Jeong, Kyung-Il;Lee, Byung-Chul;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.147-151
    • /
    • 2009
  • Purpose: 2-[$^{18}F$]Fluoro-2-deoxy-D-glucose ([$^{18}F$]FDG) particularly plays as a important role in Positron Emission Tomography (PET) imaging in nuclear medicine. Domestic [$^{18}F$]FDG auto synthesizers are installed in Seoul National University Bundang Hospital (SNUBH) at June 2008, these modules were known that it's synthetic yields were guaranteed in average $45{\pm}5%$ so far. To improve yields and convenience of domestic [$^{18}F$]FDG auto synthesizer, numerous trials in reaction time, base concentration, pressure and temperature were performed to increase [$^{18}F$]FDG yields. Materials and Methods: Several synthetic factors (temperature, time and pressure) and shortcoming were corrected based on many evaporation test. Syringe dispensing of tetra-butylammonium bicarbonate (TBAB) was replaced with micro pipette to prepare tetrabutyl ammonium fluoride salt ([$^{18}F$]TBAF). Troublesome refill of liquid nitrogen every 2 hours which was used to protect vacuum system was changed to charcoal cartridge, base guard filter. To monitor the volume of delivered $[^{18}O]OH_2$ from cyclotron by surveillance camera, we set up the volumetric vial on the cover of the module. In addition to, the recovery vial was added in [$^{18}F$]FDG production system to recover [$^{18}F$]FDG loss due to the leak of valve ($V_{13,14}$) in [$^{18}F$]FDG purification process. Results: When we used micro pipette for adding TBAB ($30\;{\mu}L$ in 12% $H_2O$ in acetonitrile), this quantitative dispensation has enabled to improve $5.5{\pm}1.7%$ residual fluorine-18 activity in fluorine separation cartridge compared to syringe adding. Besides, the synthetic yields of [$^{18}F$]FDG has increased $58{\pm}2.6%$ (n=19), $58{\pm}2.9%$ (n=14), $60%{\pm}2.5%$ (n=17) for 3 months. The life cycle of charcoal cartridge and base vacuum was 3 months prior to filling liquid nitrogen every 2 hours and additional side separator can prevent pump corrosion by organic solvent. After setting of volumetric indicator vial, the operator can easily monitor the total volume of irradiated $[^{18}O]OH_2$ from cyclotron. The recovery vial can be used for the stabilizer when an irregular [$^{18}F$]FDG loss was generated by the leak of valves ($V_{13,14}$). Conclusions: We has optimized appropriate synthetic conditions (temperature, time, pressure) in domestic [$^{18}F$]FDG auto synthesizer. In addition to, the remodeling with several accessories improve yields of domestic [$^{18}F$]FDG auto synthesizer with reliable reproducibility.

  • PDF

Enhanced Efficacy of Human Brain-Derived Neural Stem Cells by Transplantation of Cell Aggregates in a Rat Model of Parkinson's Disease

  • Shin, Eun Sil;Hwang, Onyou;Hwang, Yu-Shik;Suh, Jun-Kyo Francis;Chun, Young Il;Jeon, Sang Ryong
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.5
    • /
    • pp.383-389
    • /
    • 2014
  • Objective : Neural tissue transplantation has been a promising strategy for the treatment of Parkinson's disease (PD). However, transplantation has the disadvantages of low-cell survival and/or development of dyskinesia. Transplantation of cell aggregates has the potential to overcome these problems, because the cells can extend their axons into the host brain and establish synaptic connections with host neurons. In this present study, aggregates of human brain-derived neural stem cells (HB-NSC) were transplanted into a PD animal model and compared to previous report on transplantation of single-cell suspensions. Methods : Rats received an injection of 6-OHDA into the right medial forebrain bundle to generate the PD model and followed by injections of PBS only, or HB-NSC aggregates in PBS into the ipsilateral striatum. Behavioral tests, multitracer (2-deoxy-2-[$^{18}F$]-fluoro-D-glucose ([$^{18}F$]-FDG) and [$^{18}F$]-N-(3-fluoropropyl)-2-carbomethoxy-3-(4-iodophenyl)nortropane ([$^{18}F$]-FP-CIT) microPET scans, as well as immunohistochemical (IHC) and immunofluorescent (IF) staining were conducted to evaluate the results. Results : The stepping test showed significant improvement of contralateral forelimb control in the HB-NSC group from 6-10 weeks compared to the control group (p<0.05). [$^{18}F$]-FP-CIT microPET at 10 weeks posttransplantation demonstrated a significant increase in uptake in the HB-NSC group compared to pretransplantation (p<0.05). In IHC and IF staining, tyrosine hydroxylase and human ${\beta}2$ microglobulin (a human cell marker) positive cells were visualized at the transplant site. Conclusion : These results suggest that the HB-NSC aggregates can survive in the striatum and exert therapeutic effects in a PD model by secreting dopamine.

Development and optimization of C-11 gas target system in KOTRON-13 cyclotron (KOTRON-13 사이클로트론의 고효율C-11 가스 표적장치)

  • Lee, Hong-Jin;Lee, Won-Kyeong;Park, Jun-Hyung;Moon, Byung-Seok;Lee, In-Won;Chae, Sung-Ki;Lee, Byung-Chul;Kim, Sang-Eun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.86-89
    • /
    • 2011
  • Purpose: The KOTRON-13 cyclotron was developed in South Korea and was introduced to regional cyclotron centers to produce short-lifetime medical radioisotopes. However, this cyclotron has limited capacity to produce carbon-11 isotope so far. We herein study how to develop and optimize an effective carbon-11 target system in the KOTRON-13 cyclotron by changing cooling system, combing with fluorine-18 target and evaluating beam currents. Materials and Method: To develop the optimal carbon-11 target and an effective cooling system, we designed the carbon-11 target system by Stopping and Range of Ions in Matter (SRIM) simulation program and considered the cavity pressure during irradiation at target grid. In this investigation, we evaluated the yield of carbon-11 production at different beam currents and the stability of the operation of the KOTRON-13 cyclotron. Results: The production of carbon-11 was enhanced from about 1.700 mCi ($50{\mu}A$) to 2,000 mCi ($60{\mu}A$) on the carbon-11 target which developed by seoul national university bundang hospital (SNUBH) and Samyoung Unitech. Additionally, the cooling condition was showed stable to produce carbon-11 under high beam current. Conclude: The carbon-11 target system of the KOTRON-13 cyclotron was successfully developed and improved carbon-11 production. Consequently, the operation of carbon-11 target system was highly effective and stable compare with other commercial cyclotrons. Our results are believed that this optimal carbon-11 target system will be helpful for the routine carbon-11 production in the KOTRON-13 cyclotron.

  • PDF

Prognostic value of nodal SUVmax of 18F-FDG PET/CT in nasopharyngeal carcinoma treated with intensity-modulated radiotherapy

  • Lee, So Jung;Kay, Chul-Seoung;Kim, Yeon-Sil;Son, Seok Hyun;Kim, Myungsoo;Lee, Sea-Won;Kang, Hye Jin
    • Radiation Oncology Journal
    • /
    • v.35 no.4
    • /
    • pp.306-316
    • /
    • 2017
  • Purpose: To investigate the predictive role of maximum standardized uptake value ($SUV_{max}$) of 2-[$^{18}F$]fluoro-2-deoxy-D-glucose($^{18}F-FDG$) positron emission tomography/computed tomography (PET/CT) in nasopharyngeal cancer patients treated with intensity-modulated radiotherapy (IMRT). Materials and Methods: Between October 2006 and April 2016, 53 patients were treated with IMRT in two institutions and their PET/CT at the time of diagnosis was reviewed. The $SUV_{max}$ of their nasopharyngeal lesions and metastatic lymph nodes (LN) was recorded. IMRT was delivered using helical tomotherapy. All patients except for one were treated with concurrent chemoradiation therapy (CCRT). Correlations between $SUV_{max}$ and patients' survival and recurrence were analyzed. Results: At a median follow-up time of 31.5 months (range, 3.4 to 98.7 months), the 3-year overall survival (OS) and disease-free survival (DFS) rates were 83.2% and 77.5%, respectively. In univariate analysis, patients with a higher nodal pre-treatment $SUV_{max}$ (${\geq}13.4$) demonstrated significantly lower 3-year OS (93.1% vs. 55.5%; p = 0.003), DFS (92.7% vs. 38.5%; p < 0.001), locoregional recurrence-free survival (100% vs. 50.5%; p < 0.001), and distant metastasis-free survival (100% vs. 69.2%; p = 0.004), respectively. In multivariate analysis, high pre-treatment nodal $SUV_{max}$ (${\geq}13.4$) was a negative prognostic factor for OS (hazard ratio [HR], 7.799; 95% confidence interval [CI], 1.506-40.397; p = 0.014) and DFS (HR, 9.392; 95% CI, 1.989-44.339; p = 0.005). Conclusions: High pre-treatment nodal $SUV_{max}$ was an independent prognosticator of survival and disease progression in nasopharyngeal carcinoma patients treated with IMRT in our cohort. Therefore, nodal $SUV_{max}$ may provide important information for identifying patients who require more aggressive treatment.

Usefulness of a FDG-PET Scan in Assessing Recurrent Gastric Cancer (재발한 위암의 진단에 사용된 FDG-PET의 유용성)

  • Lee Hyeon Kook;Lee Kyu Eun;Kim Yoon Ho;Jeong Jae Min;Yang Han-Kwang;Chung June Key;Lee Kuhn Uk;Choe Kuk Jin
    • Journal of Gastric Cancer
    • /
    • v.1 no.3
    • /
    • pp.174-179
    • /
    • 2001
  • Purpose: For curative resection of recurrent gastric cancer, it is imperative that there be no unrecognized foci of tumoral disease outside the operation field. PET (positron emission tomography) with FDG (18 fluoro-2 deoxy-D-glucose) is a whole-body imaging technique that exploits the increased rate of glycolysis in tumor cells to detect disease. The authors evaluated the usefulness of FDG-PET in assessing resectability of recurrent gastric cancer. Materials and Methods: Seven patients with recurrent gastric cancer were studied with FDG-PET from December 1998 to October 2000. All FDG-PET images were interpreted in conjunction with conventional diagnostic methods. All imaging results were correlated with the pathological diagnosis and clinical outcome. Results: A final diagnosis of recurrence was obtained at 14 sites in all 7 patients by histology or clinical follow up. Locoregional recurrence, including distant metastasis, developed in 6 of 7 patients and distant recurrence in only one. FDG-PET detected all recurrent sites (5 locoregional and 5 distant) in 5 patients without peritoneal recurrence, but did not detect peritoneal seeding in 2 patients with peritoneal recurrence. The accuracy of FDG-PET in estimating resectability was $71.4\%$ (5/7), and that of CT and PET together was $85.7\%$ (6/7). A curative resection could be performed in three of the recurrent patients (2 locoregional and 1 distant recurrence). Conclusion: Our results suggest that FDG-PET may be useful for detecting locoregional and distant recurrence of gastric cancer and for selecting appropriate treatment. However, considering that FDG-PET was limited in detecting peritoneal seeding and determining the exact anatomical extension of tumor, it should be used in conjunction with other anatomical images.

  • PDF

Quality Control of Residual Solvents in $[^{18}F]$FDG Preparations by Gas Chromatography (기체 크로마토그래피를 이용한 $[^{18}F]$FDG 주사액 중의 잔류 용매의 정도관리)

  • Lee, Hak-Jeong;Jeong, Jae-Min;Lee, Yun-Sang;Kim, Hyung-Woo;Chang, Young-Soo;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.6
    • /
    • pp.566-569
    • /
    • 2007
  • Purpose: Analysis of volatile organic solvents in 2-deoxy-2-$[^{18}F]$ fluoro-D-glucose ($[^{18}F]$FDG) preparations was performed by gas chromatography (GC), in accordance with USP. Materials and Methods: Analyses were carried out on a Hewlett-Packard 6890 gas chromatography equipped with an FID. Results: We determined the amounts of ethanol and acetonitrile on every batch of our routine $[^{18}F]$FDG preparations, ranging between 5000 ppm and 100 ppm. In our routine preparation of $[^{18}F]$FDG, the amount of acetonitrile and ethanol in the final product were well below the maximum allowable limit described in the USP. Conclusion: Our $[^{18}F]$FDG preparations were in accordance with the suggested USP maximum allowable levels of the quality control analysis of volatile organic compounds.

Evaluation of the Response of Radiotherapy to Squamous Cell Carcinoma of the Head and Neck using $^{18}FDG-PET$ (두경부 편평상피세포암종에서 $^{18}FDG-PET$을 이용한 방사선치료 반응평가)

  • Lee Sang-Wook;Ryu Jin-Sook;Yi Byong-Yong;Kim Jong-Hoon;Ahn Seung-Do;Shin Seong-Soo;Kim Sang-Yoon;Nam Soon-Yuhl;Song Si-Yeol;Yoon Sang-Min;Park Jin-Hong;Kim Sung-Bae;Kim Jae-Seung
    • Korean Journal of Head & Neck Oncology
    • /
    • v.19 no.1
    • /
    • pp.58-62
    • /
    • 2003
  • Purpose: To evaluate the efficacy of positron emission tomography with 2-[F-18] fluoro-2-deoxy-D-glucose in discrimination of response in the nasopharyngeal carcinoma patients who treated with radiotherapy. Methods and Materials: Twenty-four patients who underwent FDG-PET scan before and after radiotherapy for no disseminated head and neck carcinoma at the Asan Medical Center between August 2001 and September 2002 were evaluate by prospective analysis. First FDG-PET scan performed before radiotherapy within 1 month, and second FDG-PET scan performed 1 month after radiotherapy. FDG-PET images were analyzed by standard uptake value (SUV). Follow-up period was more than 6 months. Results: The pretreatment SUV was 3.4-14.0 (median: 6.0) and posttreatment SUV was ground level-7.7 (median: 2.0). The overall sensitivity and specicity of FDG-PET to evaluate residual tumors in the nasopharyngeal carcinoma patients were 94% and 94%. Conclusion: FDG-PET is effective in evaluation of radiation response in the nasopharyngeal carcinoma. We think that the timing of one month after finished radiotherapy FDG-PET scan was not too fast to evaluation of radiation response.

Distinguishing between Thymic Epithelial Tumors and Benign Cysts via Computed Tomography

  • Sang Hyup Lee;Soon Ho Yoon;Ju Gang Nam;Hyung Jin Kim;Su Yeon Ahn;Hee Kyung Kim;Hyun Ju Lee;Hwan Hee Lee;Gi Jeong Cheon;Jin Mo Goo
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.671-682
    • /
    • 2019
  • Objective: To investigate whether computed tomography (CT) and fluorine-18-labeled fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) may be applied to distinguish thymic epithelial tumors (TETs) from benign cysts in the anterior mediastinum. Materials and Methods: We included 262 consecutive patients with pathologically proven TETs and benign cysts 5 cm or smaller who underwent preoperative CT scans. In addition to conventional morphological and ancillary CT findings, the relationship between the lesion and the adjacent mediastinal pleura was evaluated qualitatively and quantitatively. Mean lesion attenuation was measured on CT images. The maximum standardized uptake value (SUVmax) was obtained with FDG-PET scans in 40 patients. CT predictors for TETs were identified with multivariate logistic regression analysis. For validation, we assessed the diagnostic accuracy and inter-observer agreement between four radiologists in a size-matched set of 24 cysts and 24 TETs using a receiver operating characteristic curve before and after being informed of the study findings. Results: The multivariate analysis showed that post-contrast attenuation of 60 Hounsfield unit or higher (odds ratio [OR], 12.734; 95% confidence interval [CI], 2.506-64.705; p = 0.002) and the presence of protrusion from the mediastinal pleura (OR, 9.855; 95% CI, 1.749-55.535; p = 0.009) were the strongest CT predictors for TETs. SUVmax was significantly higher in TETs than in cysts (5.3 ± 2.4 vs. 1.1 ± 0.3; p < 0.001). After being informed of the study findings, the readers' area under the curve improved from 0.872-0.955 to 0.949-0.999 (p = 0.066-0.149). Inter-observer kappa values for protrusion were 0.630-0.941. Conclusion: Post-contrast CT attenuation, protrusion from the mediastinal pleura, and SUVmax were useful imaging features for distinguishing TETs from cysts in the anterior mediastinum.

Prognostic Value of Preoperative Positron Emission Tomography-Computed Tomography in Surgically Resected Stage I and II Non-Small Cell Lung Cancer (I, II병기 비소세포폐암의 예후에 대한 수술 전 양전자방출 컴퓨터 단층촬영기의 임상적 의의)

  • Song, Sung-Heon;Sohn, Jang-Won;Kwak, Hyun-Jung;Kim, Sa-Il;Kim, Sang-Heon;Kim, Tae-Hyung;Yoon, Ho-Joo;Shin, Dong-Ho;Choi, Yoon-Young;Park, Sung-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.71 no.6
    • /
    • pp.425-430
    • /
    • 2011
  • Background: High 2-[$^{18}F$] fluoro-2-deoxy-D-glucose (FDG) uptake on positron emission tomography-computed tomography (PET-CT) is a prognostic factor for poor survival in non-small cell lung cancer (NSCLC), especially in Stage I. We determined whether the high FDG uptake value of a primary tumor was associated with recurrence and death in patients with resected Stage I and Stage II NSCLC. Methods: We identified consecutive patients who underwent complete surgical resection for Stage I and II NSCLC between 2006 and 2009, who had preoperative PET-CT, and reviewed clinical records retrospectively. FDG uptake was measured as the maximal standardized uptake value (SUVmax) for body weight. Patients were divided into two groups based on SUVmax: (i) above or (ii) below the cut-off value (SUVmax=5.9) determined by a receiver operating characteristic (ROC) curve. Results: Of 57 patients who were enrolled consecutively, 32 (56%) had Stage I NSCLC and 25 (44%) had Stage II. The 5-year recurrence-free survival (RFS) for patients with high (${\geq}5.9$) and low (<5.9) SUVmax were 31% and 57%, respectively (p=0.014). The 5-year overall survival (OS) rates were 39% and 60%, respectively (p=0.029). In univariate analyses, SUVmax (p=0.014), T staging (p=0.025), and differentiation of tumor tissue (p=0.034) were significantly associated with RFS. But, multivariate analyses did not show that SUVmax was an independently significant factor for RFS (p=0.180). Conclusion: High FDG uptake on PET-CT is not an independent prognostic factor for poor outcomes (disease recurrence in patients with resected Stage I and II NSCLC).