• Title/Summary/Keyword: 2-Ellipse

Search Result 195, Processing Time 0.023 seconds

Seismic Retrofitting of Existing Reinforced Concrete Columns Using Binding Column Method (외부부착형 BCM공법으로 보강된 철근콘크리트 기둥의 내진보강)

  • Hur, Moo-Won;Park, Tae-Won;Lee, Sang-Hyun;Park, Hyun-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.119-126
    • /
    • 2022
  • This study proposed a BCM(Binding Column Method) that can reinforce the insufficient seismic force of piloti buildings that are not designed for seismic resistance. In addition, 4 reinforcement specimens and 1 reference specimen were manufactured for the proposed seismic reinforcement method. The effect of improving seismic performance before and after reinforcement was examined through repeated loading tests. As a result of experiment, seismic reinforcement specimen with BCM system showed hysteretic characteristics of a large ellipse with great energy dissipation ability and increased strength and stiffness, while reference specimen showed rapid reduction in strength and brittle shear failure column. In addition, it can be seen that the reinforcing effect is improved as the gap is narrow, the torque is large, and the thickness of the L-shaped steel sheet is thicker. The SC4 specimen showed the best seismic performance reinforcement effect.

A Study on the Repair Work for Spindle Key with Damaged Part in Planner Miller by Directed Energy Deposition (DED 방식을 적용한 플래너 밀러의 손상된 스핀들 키 보수 작업에 관한 연구)

  • Lee, Jae-Ho;Song, Jin-Young;Jin, Chul-Kyu;Kim, Chai-Hwan
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.4_2
    • /
    • pp.699-706
    • /
    • 2022
  • In this study, Directed energy deposition (DED) among additive manufacturing is applied to repair damaged spindle key parts of planner miller. The material of the spindle key is SCM415, and the P21 Powder is used. In order to find the optimal deposition conditions for DED equipment, a single-line deposition experiment is conducted to analysis five parameters. The laser power affects the width, and the height is a parameter affected by coaxial gas and powder gas. In addition, laser power, powder feed rate, coaxial gas, and powder gas are parameters that affect dilution. Otimal deposition is that 400 W of laser power, 4.0 g/min of powder feed rate, 6.5 L/min of coaxial gas, 3.0 L/min of powder gas and 4.5 L/min of shield gas. By setting the optimum conditions, a uniform deposition cross section in the form of an ellipse can be obtained. Damage recovery process of spindle key consists of 3D shape design of the base and deposition parts, deposition path creation and deposition process, and post-processing. The hardness of deposited area with P21 powder on the SCM415 spindle key is 336 HV for the surface of the deposition, 260 HV for the boundary area, and 165 HV for the base material.

Center point prediction using Gaussian elliptic and size component regression using small solution space for object detection

  • Yuantian Xia;Shuhan Lu;Longhe Wang;Lin Li
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.8
    • /
    • pp.1976-1995
    • /
    • 2023
  • The anchor-free object detector CenterNet regards the object as a center point and predicts it based on the Gaussian circle region. For each object's center point, CenterNet directly regresses the width and height of the objects and finally gets the boundary range of the objects. However, the critical range of the object's center point can not be accurately limited by using the Gaussian circle region to constrain the prediction region, resulting in many low-quality centers' predicted values. In addition, because of the large difference between the width and height of different objects, directly regressing the width and height will make the model difficult to converge and lose the intrinsic relationship between them, thereby reducing the stability and consistency of accuracy. For these problems, we proposed a center point prediction method based on the Gaussian elliptic region and a size component regression method based on the small solution space. First, we constructed a Gaussian ellipse region that can accurately predict the object's center point. Second, we recode the width and height of the objects, which significantly reduces the regression solution space and improves the convergence speed of the model. Finally, we jointly decode the predicted components, enhancing the internal relationship between the size components and improving the accuracy consistency. Experiments show that when using CenterNet as the improved baseline and Hourglass-104 as the backbone, on the MS COCO dataset, our improved model achieved 44.7%, which is 2.6% higher than the baseline.

Prostate Volume Measurement by TRUS Using Heights Obtained by Transaxial and Midsagittal Scanning: Comparison with Specimen Volume Following Radical Prostatectomy

  • Sung Bin Park;Jae Kyun Kim;Sung Hoon Choi;Han Na Noh;Eun Kyung Ji;Kyoung Sik Cho
    • Korean Journal of Radiology
    • /
    • v.1 no.2
    • /
    • pp.110-113
    • /
    • 2000
  • Objective: The purpose of this study was to determine, when measuring prostate volume by TRUS, whether height is more accurately determined by transaxial or midsagittal scanning. Materials and Methods: Sixteen patients who between March 1995 and March 1998 underwent both preoperative TRUS and radical prostatectomy for prostate cancer were included in this study. Using prolate ellipse volume calculation (height × length × width × 𝜋/6), TRUS prostate volume was determined, and was compared with the measured volume of the specimen. Results: Prostate volume measured by TRUS, regardless of whether height was determined transaxially or midsagittally, correlated closely with real specimen volume. When height was measured in one of these planes, a paired t test revealed no significant difference between TRUS prostate volume and real specimen volume (p = .411 and p = .740, respectively), nor were there significant differences between the findings of transaxial and midsagittal scanning (p = .570). A paired sample test, however, indicated that TRUS prostate volumes determined transaxially showed a higher correlation coefficient (0.833) and a lower standard deviation (9.04) than those determined midsagittally (0.714 and 11.48, respectively). Conclusion: Prostate volume measured by TRUS closely correlates with real prostate volume. Furthermore, we suggest that when measuring prostate volume in this way, height is more accurately determined by transaxial than by midsagittal scanning.

  • PDF

Estimation of Effective Range of HFR Data and Analysis of M2 Tidal Current Characteristics in the Jeju Strait (제주해협 HFR 자료의 유효 범위 산정과 M2 조류 특성 분석)

  • Oh, Kyung-Hee;Lee, Seok;Park, Joonseong;Song, Kyu-Min;Jung, Dawoon
    • Ocean and Polar Research
    • /
    • v.42 no.2
    • /
    • pp.115-131
    • /
    • 2020
  • The effective range of surface current data observed by high-frequency radar (HFR) operated in the northern coastal area of Jeju Island by Korea Institute of Ocean Science and Technology was estimated and the distribution and variability of the M2 tidal current of the Jeju Strait was analyzed. To evaluate the HFR data, the M2 tidal current corrected from 25 hours current data observed by the Korea Hydrographic and Oceanographic Agency (KHOA) was compared with the M2 tidal current in the Jeju Strait analyzed from the surface currents of HFR. The reliability of HFR data was confirmed by analyzing the characteristics of the tide components of these two data sets, and the effective range of HFR data was estimated through temporal and spatial analysis. The observation periods of HFR used in the analysis were from 2012 to 2014, and it was confirmed that there is a difference in the effective range of HFR data according to the observation time. During the analysis periods, the difference between the M2 current ellipses from the data of KHOA and the HFR was greater in the eastern than in the western part of the Jeju Strait, and represented a high reliability in the western and central parts of the Jeju Strait. The tidal current of the Jeju Strait analyzed using the HFR data revealed a seasonal variability a relatively weak in summer and a strong in winter, about a 17% fluctuations between the summer and winter based on the length of the semi-major axis of tidal ellipse. Appraisals and results of regarding the characteristics and seasonal variability of the M2 tidal current in the Jeju Strait using HFR data have not been previously reported, so the results of this study are considered meaningful.

Detection of Group of Targets Using High Resolution Satellite SAR and EO Images (고해상도 SAR 영상 및 EO 영상을 이용한 표적군 검출 기법 개발)

  • Kim, So-Yeon;Kim, Sang-Wan
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.2
    • /
    • pp.111-125
    • /
    • 2015
  • In this study, the target detection using both high-resolution satellite SAR and Elecro-Optical (EO) images such as TerraSAR-X and WorldView-2 is performed, considering the characteristics of targets. The targets of our interest are featured by being stationary and appearing as cluster targets. After the target detection of SAR image by using Constant False Alarm Rate (CFAR) algorithm, a series of processes is performed in order to reduce false alarms, including pixel clustering, network clustering and coherence analysis. We extend further our algorithm by adopting the fast and effective ellipse detection in EO image using randomized hough transform, which is significantly reducing the number of false alarms. The performance of proposed algorithm has been tested and analyzed on TerraSAR-X SAR and WordView-2 EO images. As a result, the average false alarm for group of targets is 1.8 groups/$64km^2$ and the false alarms of single target range from 0.03 to 0.3 targets/$km^2$. The results show that groups of targets are successfully identified with very low false alarms.

A STUDY ON THE MICROSTRUCTURE OF IPS EMPRESS CERAMICS ACCORDING TO THE HEAT TREATMENT AND SPRUE TYPE (주입선 및 열처리에 따른 IPS Empress 도재의 미세구조에 관한 연구)

  • Dong, Jin-Keun;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.5
    • /
    • pp.772-785
    • /
    • 1998
  • This study was undertaken to clarify the microstructure of the different IPS Empress ingots by etching and to observe the change of leucite crystal structure according to subsequent heat treatment and the crystal distribution according to sprue types(${\phi}2.8mm$, single sprue; ${\phi}1.8mm$, double sprue) by scanning electron microscopy. IPS Empress T1, O1 ingots used for staining technique, and Dentin(A2) ingots used for layering technique were selected for this study. To observe the microstructures of these ingots before pressing, the specimens were prepared in splinters($3{\times}3{\times}3mm$) taken from the original ingots. And to estimate crystal distribution and microstructural change by sprue type and subsequent heat treatment. the specimens($3{\times}3{\times}3mm$) were heat-pressed through the two types of sprues with different diameters and numbers, and all specimens were fired according to the recommended firing schedule. The observed surface was ground with waterproof papers($#800{\sim}#1800$) on the grind polisher and was cleaned ultrasonically. All specimen were etched with 0.5% hydrofluoric acid. After etching, the surface was treated by ion sputter coating for SEM observation at an accelerating voltage of 20kV. In all specimens, the central area of ground surface was observed because there was less difference in microstructure between the peripheral area and the central area. The results were as follows ; 1. In the microstructure according to the ingot type, there was a wide difference between the staining (T1,O1) and layering(Dentin A2) ingots, but there was not a considerable difference between the T1 ingot and the O1 ingot for staining technique. 2. In all specimens, the crystal dispersion of IPS Empress ceramic using double sprue was significantly more scattered than that of IPS Empress ceramic using single sprue. The degree of scattering was strongest in the Dentin(A2) specimen and weakest in the O1 ingot. 3. In the microstructural change according to the subsequent heat treatment, all of ingots had some microcracks in the inside of the leucite crystal and the glass matrix after pressing. The inner splinters of the leucite crystal became smaller, and more microcracks occurred in the glass matrix due to increasing heat treatment times. 4. The size of leucite crystals varied from $1{\mu}m\;to\;5{\mu}m$. The mean size of mature crystals was about $5{\mu}m$. The form of the crystal was similar to a circle when it was smaller and similar to an ellipse when it was larger.

  • PDF

Comparative Study on the Urohyal of the Subfamily Gobioninae of Korea (한국산(韓國産) 모래무지아과(亞科)(Gobioninae) 어류의 미설골(尾舌骨)에 대한 비교연구)

  • Kim, Ik-Soo;Kang, Eon-Jong
    • Korean Journal of Ichthyology
    • /
    • v.1 no.1_2
    • /
    • pp.24-34
    • /
    • 1989
  • We reexamined the skulls of 14 gobionine genera of Korea to study taxonomic status of Gobioninae. The character transformation series found in the morphology of urohyal was very distinct among other skeletal characters. The gobioninae fishes of Korea were divided into 4 groups based on their morphology of urohyal as follows ; 1. Coreoleuciscus, Gnathopogon group ; The horizontal plate of urohyal has a ellipse shape with posterior edge wedged and the length is longer than that of vertical plate. 2. Hemibarbus, Squalidus group ; The horizontal plate has a elongated rhombeus shape with posterior edge pointed and the length is shorter than that of vertical plate. 3. Sarcocheilichthys, Pseudopungtungia, Pseudorasbora, Pungtungia group ; the horizontal plate has a expanded rhombeus shape, the length is longer than that of vertical plate, the hypohyal attatchment is not bifurcated, and the profile of the horizontal and vertical plate curved ventrally. 4. Ladislavia, Gobiobotia, Abbottina, Hicrophysogobio, Pseudogobio, Saurogobio group ; The horizontal plate has a pin or wedge shape expanded anteriorly, the length is shorter than that of vertical plate, and the hypohyal attatchment is thickened laterally. This results agreed with those by the adductor mandibulae complex, the geniohyoideus of cephalic muscles, and the cephalic-lateral line canals.

  • PDF

Ship′s Distance Measuring System by the GPS Receiver in Anchoring Watch (GPS 선간거리계측 시스템에 의한 묘박상황의 감시)

  • 김광홍;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.4
    • /
    • pp.257-266
    • /
    • 2001
  • It was set up MCS and MS of ship's distance measuring system in land and ship respectively and ship's track including dropped and hove up anchor was tracked by mean of measurement for ship's position, relative bearing and distance from MCS to MS. Results analyzed for possibility of real time anchoring watch and effectiveness of measuring position are as follow; (1) The elapsed time from dropped anchor to hove up anchor is 4 minutes and the elapsed time to start recording ship's track after set up anchoring state is 10 minutes approximately. (2) Shape of hull's swing during anchoring is mostly 8 figue-like or rarely peanut-like shape. (3) Mean anchoring position during whole measuring time was shifted 49m north and 89m eastly. (4) Ship's track were moved counter-clockwise for $8.1^\circ$ range from relative bearing $186.1^\circ$ to $194.2^\circ$ ellipse-like tracks with the major axis 63m and the minor axis 53m. (5) High frequency of ship's position distribution was shown at relative bearing $187^\circ$ and distance 558m while low frequency was shown at relative bearing $194^\circ$ and distance 556m. (6) The designed ship's distance measuring system by PRTK-GPS was fit very well for anchoring watch as secured necessary area demanded for dragging anchor as well as anchoring by means of real time measurement both in distance and bearing.

  • PDF

Pollen morphology of Paeonia lactiflora Pallas and its germination (작약화분(芍藥花粉)의 형태(形態) 및 발아(發芽))

  • Kim, Jae-Chul;Shin, Jong-Hee;Kim, Jung-Hye;Park, So-Deuk
    • Korean Journal of Medicinal Crop Science
    • /
    • v.4 no.3
    • /
    • pp.231-235
    • /
    • 1996
  • The experiment was conducted to determine pollen morphology of Chinese peony and its germination. The results were obtained as following ; Pollen shpae was usually large ellipse and the pol­len germination rate of Eui-seong Peony line was 71% which was lower than that of other Peony lines. In a bud, the pollen began to be observed on $7{\sim}9days$ before flowering and as getting on for flowering time, normal pollen and germination rates were higher. The pollen germination and elongation beganat 30 minutes after incubation on artificial medium and were completed after $2{\sim}3\;hours$. As the storage time went on, the pollen life span was shortened. The germination rate was 51% at 8 days-storage of room temperature. The germination rate was 48% ad 43% at 95 day-storage in $0^{\circ}C$ and $-15^{\circ}C$, respectively.

  • PDF