• Title/Summary/Keyword: 2-DVR

Search Result 87, Processing Time 0.023 seconds

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

Implementation and Performance Analysis of a Multichannel Visual Monitoring System based on DirectX (DirectX 기반 다채널 영상 감시 시스템 구현 및 성능 분석)

  • Chung Sun-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.1
    • /
    • pp.217-227
    • /
    • 2005
  • In this paper, we present the result of an efficient implementation of DirectX-based multichannel visual monitoring system and the performance analysis of it. Our proposed system mainly consists of three subsystems: display, storage, and retrieval/playback. The display subsystem is designed to utilize efficiently H/W acceleration, overlay and flip of DirectX for faster real-time display, display synchronization among channels, and improvement of tearing artifact. For the performance improvement of storage speed, the storage subsystem is designed and implemented in DirectShow Filter-based multithreading architecture so that it can store multichannel video streams efficiently in each channel with minimizing data bottleneck among channels. In the retrieval and playback subsystem, efficient index file architecture and video data storage architecture, efficient playback architecture which can make playback be processed parallel among channels are designed and implemented for faster retrieval and playback,. Through experiments, our proposed system is shown to be maximally 2 times as fast in storaging speed and maximally 3.5 times as fast in retrieval and playback speed as the previous system.

  • PDF

Analysis characteristics of officers' watch-keeping for efficient navigation bridge layout of a fisheries training vessel (효율적인 어업실습선의 선교 layout을 위한 당직항해사의 업무특성 분석)

  • KIM, Min-Son;HWANG, Bo-Kyu
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.52 no.1
    • /
    • pp.56-64
    • /
    • 2016
  • This study analyzed characteristics of officers' watch-keeping during fishing operation at the fisheries training ship KAYA (GT: 1,737 tons, Pukyong National University). It observed fishing works of three officers in wheel house of KAYA. The observations were carried out at the fishing ground 45 miles away from east of Jeju from 7 to 8 January 2010. The works and movements of the officers were recorded with three common video cameras and a 4-channel MPEG-4 Triplex DVR. Recorded data of the working circulation was analyzed by using the post-processing method. As a result of the traffic lines, the average (${\pm}S.D$) of working hour (min) and moving frequency (times), distance (m) and speed (m/min) during setting the net was 11.8 (0.9), 43.7 (8.1), 133.9 (35.8) and 10.5 (0.6), respectively. During trawling the net, it was 100, 241 (39.8), 615.7 (194.6) and 5.2 (1.6), respectively. During hauling the net, it was 17.6 (1.4), 41.0 (7.2), 196.9 (37.6) and 10.7 (0.8), respectively. In addition, it has a different tendency of the instrument usage frequency by the fishing works. During setting, the usage priority was CCTV, ECDIS, RPM and pitch controller, net monitor, GPS plotter, chart room, X-band radar, fish finder and public addressor. During trawling, it was CCTV, ECDIS, fish finder, X-band radar, net monitor, chart room, GPS plotter, RPM and pitch controller, auto pilot and steering, interphone, wind speed and direction indicator, No.1. VHF, navigation light control panel and public addressor. During hauling, it was CCTV, RPM and pitch controller, GPS plotter, public addressor, chart room, net monitor, X-band radar, auto pilot and steering and fish finder.

Determination of Practical Dosing of Warfarin in Korean Outpatients with Mechanical Heart Valves (인공심장판막 치환환자의 Warfarin 용량결정)

  • Lee Ju Yeun;Jeong Young Mi;Lee Myung Koo;Kim Ki-bong;Ahn Hyuk;Lee Byung Koo
    • Journal of Chest Surgery
    • /
    • v.38 no.11 s.256
    • /
    • pp.761-772
    • /
    • 2005
  • Background: Following the implantation of heart valve prostheses, it is important to maintain therapeutic INR to reduce the risk of thromboembolism. The objective of this study was to suggest a practical dosing guideline for Korean outpatients with prosthetic heart valves managed by a pharmacist-run anticoagulation service (ACS). Material and Method: A retrospective chart review was completed for all patients enrolled in the ACS at Seoul National University Hospital from March, 1997 to September, 2000. Patients who were at least 6 months post-valve replacement and had nontherapeutic INR value (less than 2.0 or greater than 3.0) were included. The data on 688 patients (1,782 visits) requiring dosing adjustment without any known drug or food interaction with warfarin were analyzed. The amount of adjusted dose and INR changes based on the INR at the time of the event were calculated. Aortic valve replacements (AVR) patients and mitral or double valve replacement (MVR/DVR) patients were evaluated separately. Result: Two methods for the warfarin dosage adjustment were suggested: Guideline I (mg-based total weekly dose (TWD) adjustment), Guideline II (percentage-based TWD adjustment). The effectiveness of Guideline 1 was superior to Guideline II overall in patients with both AVR and MVR/DVR. Conclusion: The guideline suggested in this study could be useful when the dosage adjustment of wafarin is necessary in outpatients with mechanical heart valves.

Affordable method of video recording for ecologists and citizen-science participants

  • Yang, Eunjeong;Lee, Keesan;Ha, Jung-moon;Kim, Woojoo;Song, Ho-Kyung;Hwang, Injae;Lee, Sang-im;Jablonski, Piotr G.
    • Journal of Ecology and Environment
    • /
    • v.42 no.2
    • /
    • pp.85-89
    • /
    • 2018
  • Observations and video documentation of interactions between animals living in dens, cavities, and other enclosed spaces are difficult, but they play an important role in field biology, ecology, and conservation. For example, bird parents visiting nests and feeding their nestlings may provide crucial information for testing of ecological hypotheses and may easily attract attention of participants of citizen-science ecological and conservation projects. Because of the nest concealment of cavity-nesting birds, their behaviors in the nest can only be studied by using video surveillance. Professional wildlife surveillance systems are extremely expensive. Here, we describe an inexpensive video setup that can be constructed with relatively little effort and is more affordable than any previously described system. We anticipate that the relatively low cost of about 250 USD for a battery-operated system is an important feature for citizen-science type of projects and for applications in heavily populated areas where the potential for theft and vandalism may be high. Based on our experiences, we provide methodological advice on practical aspects of using this system in the field for ecological research on birds. We highlight the low cost, easiness of construction, and potential availability to a large number of observers taking part in wildlife monitoring projects, and we offer technical help to participants of such research projects.

Clinical Analysis of Cardiac Valve Surgery (심장판막증의 외과적 치료)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.18 no.3
    • /
    • pp.446-455
    • /
    • 1985
  • A total and consecutive 156 patients have undergone cardiac valve surgery including 13 closed mitral commissurotomy, 13 open mitral commissurotomy, one mitral annuloplasty, 75 mitral valve replacement, one aortic annuloplasty, 24 aortic valve replacement, 3 tricuspid valve replacement, 25 double valve replacement and one triple valve replacement. 155 prosthetic valves were replaced in a period between September 1976 and August 1985. There were 68 males and 88 females with age range from 8 to 69 yrs [mean 36.5 yr]. Out of replaced valves, 61 was tissue valve including 54 Carpentier-Edwards, and 4 was mechanical valves including 74 St. Jude Medical, and the position replaced was 101 valves for mitral, 46 for aortic and 8 for tricuspid. Single valve replacement in 102 cases, double valve replacement in 25 cases [17 for AVR+MVR, and 8 for MVR+TVR], and only one case was noted in the triple valve replacement. Early mortality within 30 days after operation was noted in 11 cases [7%]; 7 after MVR, 2 after DVR, and each one after open mitral commissurotomy and mitral annuloplasty. Cause of death was valve thrombus, cerebral air embolism, low output syndrome, uncontrollable arrhythmia, parapneumonic sepsis, acute cardiac tamponade and left atrial rupture. 7 late deaths were noted during the follow-up period from 1 to 104 months [average 48 month]; three due to valve and left atrial thrombus formation, two due to CVA from overdose of warfarin, and each one due to congestive heart failure and chronic constrictive pericarditis, Anticoagulants after prosthetic valve replacement were maintained with warfarin, dipyridamole and aspirin to the level of around 50% of normal prothrombin time in 79 cases, and Ticlopidine with aspirin in 47 cases to compare the result of each group. There were 11 major thromboembolic episodes including 3 deaths in the warfarin group. Two cases of CVA due to overdose of warfarin was noted in the warfarin group. In the ticlopidine group, there was only one left atrial thrombus confirmed at the time of autopsy. Among the survived 138 cases, nearly all cases[136 cases] were included in NYHA functional class I and II during the follow-up period. In conclusion, surgical treatment of the cardiac valve disease in 156 clinical cases revealed excellent result with acceptable operative risk and late mortality. Prevention of thrombus formation with anti-platelet aggregator Ticlopidine has better result than warfarin group presently with no specific side effect such as bleeding or gastrointestinal trouble.

  • PDF

Estimation of Full Bloom Stage of Apple (Malus domestica Borkh. c. Fugi) in Chungju Area (충주지역에서의 사과 후지 품종의 만개기 추정)

  • 이양수;이정택;심교문;황규홍
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.4 no.2
    • /
    • pp.114-118
    • /
    • 2002
  • This study was conducted to estimate the full bloom stage of the Fugi apple at e in different elevations at Chungju area. The lapse rate of air temperature related to the elevation in Chungiu area was calculated and applicated to estimate the full bloom stage of the Fugi apple cultivar at different elevations. The data far nine levels of elevations at 150, 250, 359, 555, 710 m with the direction of S-W in the Mt. Gyemyong and at 165, 255, 415, 545 m with the direction of N-W in the Mt. Nam were analyzed. The lapse rate range were 0.89$^{\circ}C$ per 100 m elevation in the Mt. Gyemyong and 0.74$^{\circ}C$ in the Mt. Nam respectively. The difference of full bloom stage different elevations was 4 to 5 days per 100 m and its range was from April 29th at 100 m to May 10th at 400 m.

A New Optical Media API for Real-Time Recording (실시간 기록을 위한 광매체 API)

  • Lee, Min-Suk;Song, Jin-Seok;Yun, Chan-Hee
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.13 no.2
    • /
    • pp.75-85
    • /
    • 2007
  • There are many embedded systems which store and play multimedia streams on optical media such as recordable cd and dvd. Some of those are PVRs, DVRs, and camcorders. In this paper we describe the design and implementation of a new, well structured, fully documented, operating system independent and open source optical media API which can be used in various applications and embedded systems. We also design an ISO-9660 compliant optical media layout, an API set and the scenario for real-time recording. To prove the usability, we develop a text application to replace well-known CD-burning software, cdrecord, and a graphic burning application. All the implementations are firstly done on Linux PC environment, and then ported to a commercial embedded system which uses pSOS as an operating system.

Long-Term Clinical Results with the St. Jude Medical Cardiac Valve Prosthesis (St. Jude Medical판막치 환술의 장기 임상성적)

  • 김윤규;류지윤
    • Journal of Chest Surgery
    • /
    • v.29 no.9
    • /
    • pp.964-970
    • /
    • 1996
  • One hundred eight patients (Feb.'86, through Jan.'96) underwent 53 mitral(MVR), 20 aortic(AVR), )5 double(DVR) valve replacement with SJM prosthesis. There were 55 males and 53 females whose mean age was 36.3 $\pm$ 10.4 years. We used 143 valves in mitral(88), aortic(54), and tricuspid(1) sites. The size and number of valves were 31 mm(32). 33inm(23), 29mm(20), 27mm(10), 25mm(2), and 35mm(1) in mitral site; 2)mm(21), 21mm(1 S), 19mm(7), 25mm(5), 27mm(2), and 33mm(1) in aortic site; and Blmm(1) in tricuspid site. Preoperative NYHA functional classes were II(14), III(73) and IV(21), and which were improved into I(89) and II(16) postoperatively. Early postoperative complications occurred in 15 cases(13.9%) in which LOS was the most common one(5 cases; 4.6%). fatly hospital death occurred in 3 cases(2.8%) due to LOS(1) and sudden cardiac arrest(2) he cummulative total follow-up period was 437.6 pl-yr with a mean of 4.1$\pm$2.9 years. There were 5 events of valve related'complications (2 TE, 1 paravalvular leak, 1 TE+paravalvular leak, 1 PVE) with the occurrence rate as 1.14%/pt-yr. Reoperation was performed in 2 cases and there were 2 cases of valve related death due to one PVE and one paravalvlllar leak. The complication free rate was 91.4$\pm$ ).4% at 10 years. Actuarial survival rate was 93.6 $\pm$ 3.1 % at 10 years.

  • PDF

Fish length dependence of target strength for black rockfish, goldeye rockfish at 70kHz and 120kHz (70kHz 및 120kHz에 있어서 조피볼락, 불볼락에 대한 반사강도의 체장 의존성)

  • Mun, Jae-Ho;Lee, Dae-Jae;Shin, Hyeong-Il;Lee, Yoo-Won
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.42 no.1
    • /
    • pp.30-37
    • /
    • 2006
  • Black rockfish and goldeye rockfish are commercially important fish species due to the increasing demand in Korea. When estimating the abundance of stocks for these species acoustically, it is of crucial importance to know the target strength(TS) to length dependence. In relation to these needs, TS measurement was conducted on black rockfish and goldeye rockfish in an acrylic salt water tank using 70kHz and 120kHz split beam echo sounders. The TS for these two species under the controlled condition was simultaneously measured with the swimming movement by DVR system and analyzed as a function of fish length(L). The results obtained are summarized as follows: The best fit regression of TS on fish length of black rockfish was TS=19.38 Log(L, cm)-70.46 ($r^2=0.71$) at 70kHz and TS=22.39 Log(L, cm)-70.40 ($r^2=0.64$) at 120kHz and in the standard form TS=20 Log(L, cm)-71.29 ($r^2 = 0.70$) at 70kHz and TS=20 Log(L, cm)-66.88 ($r^2=0.57$) at 120kHz. The best fit regression of TS on fish length of goldeye rockfish was TS=17.10 Log(L, cm)-68.28 ($r^2=0.37$) at 70kHz and TS=24.39 Log(L, cm)-73.74 ($r^2=0.59$) at 120kHz and in the standard form TS=20 Log(L, cm)-72.03 ($r^2=0.32$) at 70kHz and TS=20 Log(L, cm)-67.68 ($r^2=0.64$) at 120kHz. An empirical model for fish TS(dB) averaged over the dorsal aspect of 115 fishes of black rockfish and goldeye rockfish and which spans the fish length(L, m) to wavelength($\lambda$, m) ratio between 8 and 30 was derived : TS=34.12 Log(L)-14.12 Log($\lambda$)-23.83, ($r^2=0.90$).