• Title/Summary/Keyword: 2-D measurement

Search Result 3,175, Processing Time 0.03 seconds

The Measurement and Analysis of LiF:Mg, Cu, Na, Si TL Material by Thermoluminescence Spectrum (LiF:Mg, Cu, Na, Si TL 물질의 열자극발광스펙트럼 측정 및 분석)

  • Lee, J.I.;Moon, J.H.;Kim, D.H.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.149-153
    • /
    • 2001
  • Three-dimensional thermoluminescence(TL) spectra of LiF: Mg, Cu, Na, Si TL material based on temperature, wavelength and intensity were measured and analyzed. The glow curves were obtained by integration of luminescence intensity for wavelength at each temperature, and various trapping parameters related to the trap formation were determined by analyzing these curves. Computerized glow curve deconvolution(CGCD) method which based on general order kinetics(GOK) model were used for the glow curve analysis. The glow curves of LiF:Mg, Cu, Na, Si TL material were deconvoluted to six isolated glow curves which have peak temperature at 333 K, 374 K, 426 K, 466 K, 483 K and 516 K, respectively. The 466 K main glow peak had an activation energy of 2.06 eV and a kinetic order of 1.05. This TL material was also found to have three recombination centers, 1.80 eV, 2.88 eV and 3.27 eV by TL spectra analysis based on Franck-Condon model. It showed that 2.88 eV is the dominant center, followed by 3.27 eV level, and 1.80 eV center is ascertained as emission center of this material even though its very weak emission intensity.

  • PDF

Development of Heat Dissipation Measuring System for 1.2-kW BLDC Motor (1.2kW 급 BLDC 모터의 열 발산 측정 시스템 개발)

  • Lee, Injun;Ye, Jungwoo;Lee, Daehun;Hwang, Pyung;Shim, Jaesool
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.11
    • /
    • pp.1423-1428
    • /
    • 2013
  • In this study, a heat dissipation measurement system is developed to analyze a 1.2-kW BLDC motor. It is important to check the temperature of the motor because an increase in temperature causes problems in the motor insulations, which in turn influences the motor life. A generator for a vehicle is installed to set up a load. We changed the load from 165 to 495 W. While the rpm varies from 2000 to 4000 under various load conditions, the changes in temperature were measured for the operating period by using a thermocouple. The results of experiments conducted under natural convection conditions suggest that the temperature was not stationary with the rpm, load, and coil of the motor and it kept increasing over $120^{\circ}C$. However, under forced convection conditions, the temperature stationarily reached $84^{\circ}C$ after 4000 s. The difference between the maximum and the minimum temperatures was $10-26^{\circ}C$ with an increase in the rpm and load. The orders of high temperature were as follows: motor coil (Ch#1), side of motor surface (Ch#5), inside of motor cap (Ch#2), upper side of motor surface (Ch#4), and inner wall of the motor (Ch#3).

Quality Evaluation and Residual Pesticides of Lettuce during Growth after Transplanting (정식(定植) 후 양상추의 품질평가 및 잔류농약 분석)

  • Youn, Aye-Ree;Kim, Byeong-Sam;Kim, Sang-Hee;Kwon, Ki-Hyun;Cha, Hwan-Soo
    • Food Science and Preservation
    • /
    • v.14 no.2
    • /
    • pp.124-130
    • /
    • 2007
  • Lettuce (Lactuca Sativa L.) is the most popular salad vegetable crop The purpose of this study was to analyze the quality of lettuce, and residual pesticides in this vegetable, during growth after transplanting. The eatable weight was 40% of the total weight at the commencement of transplanting, but had doubted at harvest after transplanting. As lettuce grew after transplanting, the pH, the sugar level, and the moisture content increased slightly, and the color tended towards yellow rather than greenThe SPDA chlorophyll measurement was 16.84 at 42 day post-ransplantation, and increased to 26.44 at 67 day after transplanting. The contents of vitamin C were 2.5mg/100g wet weight at 60 d after transplantation, but decreased to 2.2mg/100g wet weight 67 day post-transplantation. Mineral (Ca, Fe, K, Mg, and Na) levels rose after transplantation, and attained their highest levels 60 day post-transplantation. The lettuce crop was analyzed for residues of each of 48 pesticides nt 54 after transplantation, and the only such chemical detected was chlorthalonil(0.03 0.25mg/kg wet weight).

The Interdigitated-Type Capacitive Humidity Sensor Using the Thermoset Polyimide (열경화성 폴리이미드를 이용한 빗살전극형 정전용량형 습도센서)

  • Hong, Soung-Wook;Kim, Young-Min;Yoon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.604-609
    • /
    • 2019
  • In this study, we fabricated a capacitive humidity sensor with interdigitated (IDT) electrodes using a thermosetting polyimide as a humidifying material. First, the number of electrodes, thickness, and spacing of the polyimide film were optimized, and a mask was designed and fabricated. The sensor was fabricated on a silicon substrate using semiconductor processing equipment. The area of the sensor was $1.56{\times}1.66mm^2$, and the width of the electrode and the gap between the electrodes were each $3{\mu}m$. The number of electrodes was 166, and the length of an electrode was 1.294 mm for the sensitivity of the sensor. The sensor was then packaged on a PCB for measurement. The sensor was inserted into a chamber environment with a temperature of $25^{\circ}C$ and connected to an LCR meter to measure the change in capacitance at relative humidity (RH) of 20% to 90%, 1 V, and 20 kHz. The results showed a sensitivity of 26fF/%RH, linearity of < ${\pm}2%RH$, and hysteresis of < ${\pm}2.5%RH$.

Comparison on accuracy of porcelain color reproducibility using two colorimeters (2종의 측색기에 의한 도재 색조 재현의 정확성 비교)

  • Lee, Tai-Il;Ahn, Jin-Soo;Kim, Young-Soo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.348-355
    • /
    • 2009
  • Statement of problem: Although the use of colorimeter to improve the accuracy of tooth color measurement has increased, it is real situation that there is almost no comparative study about the accuracy among various colorimeters. Purpose: The purpose of this study is to compare the accuracy of porcelain color reproducibility using ShadeEye-Ncc dental chroma meter (Shofu Inc., Kyoto, Japan) and Shadepilot$^{TM}$ system (Degudent Inc., Hanau, Germany). Material and methods: Color of 2M2 and 3M2 shade tap of Vitapan 3D Master shade guide were measured using the above two colorimeters. Porcelain specimens were fabricated through this data. The porcelain systems used were Vintage Halo Porcelain system with ShadeEye-Ncc dental chroma meter, and VitaOmega900 Porcelain system with Shadepilot$^{TM}$ system. Colors of shade tap models and porcelain specimen were measured with spectrophotometer, and calculated delta E based on the results. Results: The following results were obtained. 1. Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility compared to ShadeEye-Ncc dental chroma meter (P <.05). 2. The result showed the difference of porcelain color reproducibility according to shade of Shade tap which is model. More suitable porcelain color reproducibility was shown at 3M2 shade tap than at 2M2 shade tap (P <.05). 3. The average of ${\Delta}E*$ of porcelain specimens which was made by the two colorimeters was 4.44-6.14, so the difference of shade was shown through the naked eye. Conclusion: Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility. When using ShadeEye-Ncc dental chromameter, it will be necessary to improve accuracy through coloring various parts of the whole tooth.

Detection of IgG and IgM antibodies with ELISA technique in human trichomoniasis (질트리코모나스 환자에서 효소표식 면역검사법을 이용한 혈청 내 항-질트리코모나스 IgG 및 IgM 항체가의 측정)

  • 이미리;신명헌
    • Parasites, Hosts and Diseases
    • /
    • v.28 no.1
    • /
    • pp.25-30
    • /
    • 1990
  • The direct wet mount examination of vaginal. secretion, widely applied for the diagnosis of Trichcmonas vaginalis infection in woman patients, is rapi4 and economical, however, the sensitivity of this technique is not so high. In this study enzyme-linked immunosorbent assay (ELISA) was employed for the detection of serum anti-T. vaginalis IgG and IsM antibodies from 30 vaginal trichomoniasis patients and 30 non-infected healthy persons. The results were as follows: 1. Serum ELISA-IgG value was $0.37{\pm}0.134(Mean{\pm}S.D.)$ in vaginal trichomoniasis patients and $0.21{\pm}0.054$ in healthy controls(P<0.005), and the sensitivity and specificity of ELISA for serum IgG antibody were 70.0% and 96.7%, respectively. 2. Serum ELISA-IgM value was $0.33{\pm}0.177 (Mean{\pm}S.D.)$ in vaginal trichomonlasls patients and $0.11{\pm}0.051$ in healthy controls (p<0.005), and the sensitivity and specificity of ELISA for serum IsM antibody were 70.0% and 96.7%, respectively. 3, The ELISA-IgG values showed a significant correlation with ELISA-IgM values(r=0.77, p<0.005) , With above results, it is assumed that ELISA is a reliable method for the diagnosis of T vaginalis infection and simultaneous measurement of serum IgG and IgM with this technique is recommended.

  • PDF

Wideband CMOS Voltage-Controlled Oscillator(VCO) for Multi-mode Vehicular Terminal (융복합 차량 수신기를 위한 광대역 전압제어 발진기)

  • Choi, Hyun-Seok;Diep, Bui Quag;Kang, So-Young;Jang, Joo-Young;Bang, Jai-Hoon;Oh, Inn-Yul;Park, Chul-Soon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.6
    • /
    • pp.63-69
    • /
    • 2008
  • Reconfigurable RF one-chip solutions have been researched with the objective of designing for smaller-sized and more economical RF transceiver and it can be applied to a vehicular wireless terminal. The proposed voltage-controlled oscillator satisfies the targeted frequency range ($4.2{\sim}5.4\;GHz$) and the frequency planning which correspond to the standards such as CDMA(IS-95), PCS, GSM850, EGSM, WCDMA, WLAN, Bluetooth, WiBro, S-DMB, DSRC, GPS, and DVB-H/DMB-H/L(L Band). In order to improve phase noise performance, PMOS is adopted in the cross-coupled pair, the tail current source and MOS varactor in this VCO and differential-typed switching is proposed in capacitor array. Based on the measurement results, a total power dissipation is $5.3{\sim}6.0\;mW$ at 1.8 V power supply voltage. The oscillator is tuned from 4.05 to 5.62 GHz; The tuning range is 33%. The phase noise is -117.16 dBc/Hz at 1 MHz offset frequency and the FOM (Figure Of Merit) is $-180.84{\sim}-180.5$.

  • PDF

A Study on the Effect of Erycibae Caulis and Corydalis Tuber Pharmacopuncture on a Mouse Model with Collagen Induced Rheumatoid Arthritis (정공등현호색(丁公藤玄胡索) 약침(藥鍼)이 류마티스 관절염 생쥐 모델에 미치는 영향)

  • Kim, Hyun Ji;Jeon, Ju Hyun;Kim, Young Il
    • Journal of Acupuncture Research
    • /
    • v.33 no.2
    • /
    • pp.21-34
    • /
    • 2016
  • Objectives : The aim of the present study is to examine the effect and mechanism of Erycibae Caulis and Corydalis Tuber Pharmacopuncture (ECP) on a mouse model with collagen induced rheumatoid arthritis (CIA). Methods : We evaluated the Aspartate aminotransferase (AST), Alanine aminotransferase (ALT), Creatinine, and the Blood urea nitrogen (BUN) of serum to examine the safety of this study. In vivo, we compared the results of the non-treated group, the normal saline pharmacopuncture treated control group, the indomethacin treated group and the ECP group. We evaluated rheumatoid arthritis manifestation and the Rheumatoid Arthritis Index (AI). Also, immune cells in blood affected by ECP were evaluated by calculating the level of white blood cells (WBC), neutrophil, lympocytes and monocytes. Next, the level of Immunoglobulin M (IgM), Immunoglobulin G (IgG), Interleukin (IL)-$1{\beta}$, IL-6, IL-17, Tumor Necrosis Factor (TNF)-${\alpha}$ and Granulocyte-macrophage Stimulating Factor (GM-CSF)in serum were measured. We examined the imaging of cartilage degeneration using micro CT-arthrography of the hind paw. Additionally, we examined the effects of reducing bone volume (BV) ratio and bone surface/bone volume (BS/BV) ratio with 3D Micro-CT. Finally, we did a histopathologic examination analysis. Results : The absence of liver and kidney toxicity was evident. In vivo, edema of the joints of the ECP group decreased greatly in macroscopic observation. AI measurement of the ECP group also decreased significantly compared to the control group. The level of WBC, neutrophil, lympocytes, and monocytes in the blood decreased but there was no statistical significance of this data. IgM of the ECP group decreased significantly compared to the control group. IL-$1{\beta}$, IL-6, TNF-${\alpha}$, and GM-CSF production of the ECP group decreased significantly compared to the control group. As a result of examining joint condition with 3D micro CT, deformation and destruction of the joint was shown to have decreased. Bone density of ECP group increased at a statistically significant level compared to the control group. Degree of joint inflammation of ECP group decreased significantly compared to the control group. After H&E and M-T staining, infiltration of immune cells, subsidence of the cartilage, damage to the synovial cells and joint erosion decreased. Conclusion : This study showed that ECP hindered the process of rheumatoid arthritis and protected joints and cartilage.

A Study on Liver Cirrhosis Patients행 Sick Role Behavior (간경변증환자의 환자역할행위에 관한 연구)

  • 김옥수
    • Journal of Korean Academy of Nursing
    • /
    • v.15 no.1
    • /
    • pp.30-43
    • /
    • 1985
  • Liver cirrhosis is the common cause of death in Korea today. But, if liver cirrhosis Patients were treated in the early stage of the disease Process, they can have a chance to carry their daily lives with prescribed medical and nursing regimens. Each patient has different health beliefs that there is a different Sick Role Behavior in the process of treatment. In order to increase and control the desired patient's Sick Role Behavior, it is important for nurses to understand the health beliefs influencing Sick Role Behavior. The purpose of this study was to determine factors influencing Sick Role Behavior and provide objective and scientific data to health education, treatment and nursing care. The subjects for this study were 80 Liver Cirrhosis patients selected from in and out patients of the medical department of four University Hospitals in Seoul, Won Joo and Mok Po city. Data was collected from Sep. 18, to Oct. 15, 1984. The measurement tool was the questionaire that developed by the investigator from the literature review based on Health Belief Model. The data Collection was done by interview. Analysis of data was done by use Mean, S.D., ANOVA, Pearson Correlation Coefficient and Stepwise Multiple Regression. The result of study were as follows: 1. The significant influencing variables on the Liver Cirrhosis Patient's Sick Role Behavior in general characteristics were Sex, Marital Status, Educational levels, Family's income and Duration after diagnosis. 2. Between the Sick Role Behavior and Health Belief Model, a) The first hypothesis that the stronger degree of Health Motivation, the higher degree of Liver Cirrhosis Patient's Sick Hole Behavior was supported (r=0.7892, p=0.0000). b) The second hypothesis that the higher degree of perceived susceptibility, the higher degree of Liver Cirrhosis Patients' Sick Role Behavior was supported (r=0.6383, p=0.0000) c) The third hypothesis that the higher degree of perceived severity, the higher degree of Liver Cirrhosis Patients' Sick Role Behavior was supported (r=0.5869, p=0.0000). d) The fourth hypothesis that the higher degree of perceived benefit, the higher degree of Liver Cirrhosis patient's Sick Role Behavior was supported (r=0.7535, p=0.0000). e) The fifth hypothesis that the lower degree of perceived barrier, the higher degree of Liver Cirrhosis Patient's Sick Role Behavior was supported(r=-9.7709, p=0.0000) f) The sixth hypothesis that the higher degree of knowledge in Disease, the higher degree of Liver Cirrhosis patients'lck Role Behavior was supported (r=0.7538, p=0.0000), g) In the correlation among variables, it was found positive correlation except that perceived barrier was negatively correlated. In the Stepwise Multiple Regression and Independent Variables, the factor“Health Motivation”could account for Sick Role Behavior in 62.28% of the Sample (F=128. 786, p<0.01). When the factor“perceived barrier”is added to this, it account for 70.38% of Sick Role Behavior (F=93.479, p <0.01) and the factor“knowledge in disease”is also included, it account for 74.78% of Sick Role Behavior (F=75.131, p <0.01). Finally, when the factor“perceived susceptibility”is included, it account for 75.03% of Sick Role Behavior (F=56.329, p <0.01).

  • PDF

A Planar Spiral Antenna of Multi-Tabs for Wireless Power Transmission of Inductive Coupling (전자기 유도 방식 무선 전력 전송을 위한 다중 탭을 갖는 평판형 스파이럴 안테나)

  • Kim, Jin-Wook;Son, Hyeon-Chang;Jeong, Seung-Ho;Kim, Seung-Gyun;Kim, Kwan-Ho;Park, Young-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.8
    • /
    • pp.753-760
    • /
    • 2009
  • In this paper, a novel planar spiral antenna of multi-tabs is proposed for wireless power transmission system based on low frequency magnetic inductive coupling. The proposed antenna has higher transmission efficiency than conventional antennas such a rectangular spiral antenna and a spiral antenna. Also, it has a useful property of uniform power transmission in the region of the antenna aperture. For verification, a transmitting antenna and a receiving one for a wireless power transmission system using magnetic inductive coupling of 132 kHz low frequency are designed and tested. The transmitting antenna has three-tabs spiral of unequal-space for higher uniform magnetic coupling in the antenna aperture. For reducing the receiving antenna size, two receiving antennas of unequal space two-tabs on one-side and series double sides as well are designed, respectively. From measurement, transmission efficiency of the proposed antennas is improved up to $3{\sim}10$ dB compared to conventional antennas.