• Title/Summary/Keyword: 2-D measurement

Search Result 3,175, Processing Time 0.03 seconds

Evaluation of Attenuation Rate Error on Skin Dosimeter using Monte Carlo Simulation in Photon and Electron Beam Therapy (광자선 및 전자선 치료에서 피부선량계의 측정과 시뮬레이션을 이용한 감약률 오차 평가)

  • Han, Moo-Jae;Yang, Seung-Woo;Heo, Seung-Uk;Bae, Sang-Il;Moon, Young-Min;Park, Sung-Kwang;Kim, Jin-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.841-848
    • /
    • 2020
  • In the field of radiation therapy using photon beams and electron beams, since each patient has a different sensitivity to radiation, skin side effects may occur even at the same dose. Therefore, if there is a risk of excessive dose to the skin, a dosimeter is attached to verify whether the correct dose is being investigated. However, since the skin dosimeter checks the attachment site visually by measuring a point dose, it is difficult to confirm an accurate dose distribution. As a result, the measurement and simulation errors of the material HgI2 in the 6 MV photon beam were 3.73% and 5.24%, respectively, at the minimum thickness of 25 ㎛, and the material PbI2 was 4.73% and 5.65%, respectively. On the other hand, as a result of the 6 MeV electron beam, the measurement and simulation errors of the material HgI2 were 1.35% and 1.12%, respectively, at a minimum thickness of 25 ㎛, and the material PbI2 showed relatively low attenuation error, 1.67% and 1.20%, respectively. Therefore, it was evaluated that the thickness of the photon beam within 25 ㎛ and the electron beam within 100 ㎛ is suitable to have a reduction rate error within 5%. This study presents a new research direction for a flexible dosimeter attached to the human body that is required in clinical practice and the construction conditions of a future skin dosimeter.

Studies on Food Preservation by Controlling Water Activity 1. Measurement of Sorption Isotherm of Dried Filefish Muscle by Equilibration in Dynamic Stream of Conditioned Air (식품보장과 수분활성에 관한 연구 1. 조절기류에 의한 건조말쥐치육의 등온흡습곡선의 측정)

  • HAN Bong-Ho;CHOI Soo-Il
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.14 no.4
    • /
    • pp.189-193
    • /
    • 1981
  • An apparatus for continuous measurements of sorption isotherm of dried food was manufactured to shorten the time required for equilibration. The apparatus was so designed that the temperature, air velocity and relative humidity in the experimental chamber could be controlled. The use of dynamic stream of conditioned air with a velocity of 0.2m/sec, instead of static atmosphere, allowed a faster equilibration of dried filefish muscle at $25^{\circ}C$. The mean time necessary for the equilibration of dried filefish muscle at the water activity of a given state to a higher water activity was about 45 hours. The monolayer moisture content of dried filefish muscle calculated from BET-equation was 0.092 kg water /kg dry matter at $25^{\circ}C$.

  • PDF

Biomass Production of One-year-old Hybrid Poplars and Its Estimation (식재 당년생 신품종 포플러류의 Biomass 생산량 및 생산량 추정)

  • Koo, Yeong-Bon;Shim, Sang-Yung;Noh, Eui-Rae
    • Journal of Korea Foresty Energy
    • /
    • v.7 no.1
    • /
    • pp.22-27
    • /
    • 1987
  • Above ground biomass production of one-year-old hybrid poplars was investigated to select the best clones which are suitable for short rotation forestry. The results were as follows: 1. Average dry weight of Populus alba X P. glandulosa Fl clones was 2.86 for stem,0.41 for branches 0.70 for leaves and 3.97 t/ha for total. and the ratios of green weight to dry weight were 0.47 for stem,0.36 for branches,0.31 for leaves and 0.42 for total. Dry weight of Populus nigra X P. maximowiczii Fl clones was 1.48 for stem, 0.54 for branches.0.71 for loaves and 2.73t/ha for total, and the ratios of green weight to dry weight were 0.42 for stem. 0.37 for branches, 0.28 for leaves and 0.36 for total. 2. Biomass production (green and dry weight)of Populus alba X P. glandulosa F1 clones can be predicted by diameter measurement only, but biomass production of Populus nigra X P. maximowiczii F1 clones can not be predicted by any of investigated characteristics. 3. Dry weight distribution of pepulus alba X P. glandulosa Fl clones were 73$\%$ for stem, 10$\%$ for branches and 17$\%$ for leaves, and dry weight distribution of P. Populus nigra X P. maximowiczii F1 clones were 54$\%$ for stem, 20$\%$ for branches and 26$\%$ for leaves.

  • PDF

Relationships among Brand Equity Components: An Exploratory Study of the Moderating Role of Product Type (품패자산조성부분간적상호관계(品牌资产组成部分间的相互关系): 관우산품충류조절작용적탐색연구(关于产品种类调节作用的探索研究))

  • Moon, Byeong-Joon;Park, Won-Kyu;Choi, Sang-Chul
    • Journal of Global Scholars of Marketing Science
    • /
    • v.20 no.1
    • /
    • pp.98-109
    • /
    • 2010
  • Research on the construction, measurement, and management of brand equity has been extensive since David A. Aaker(1991) and Kevin Lane Keller(1993) first advanced the concept. Recently, much attention has been devoted to the components of brand equity: brand awareness, perceived quality, brand image, and brand loyalty. This study explores the relationships among these components, focusing particularly on the moderating role of product type (utilitarian vs. hedonic) in their causal relationships. A model to study the relationship among components of brand equity, particularly the moderating role of product type, is featured in Figure 1. The hypotheses of the study are proposed as follows: that consumers' brand awareness has a positive influence on brand loyalty and brand image; that consumers' perceived quality has a positive influence on brand loyalty and brand image; that consumers' brand image influences brand loyalty positively; and that relationships among components of brand equity will be moderated by product type. That is, in the case of utilitarian products, the impact of perceived quality on brand loyalty will be relatively stronger, whereas with hedonic products the impact of brand image on brand loyalty will be relatively stronger. To determine the products for the study, a pre-test of 58 college students in the Seoul metropolitan area was conducted based on the product type scale. As a result, computers were selected as the utilitarian product and blue jeans became the hedonic product. For each product type, two brands were selected: Samsung and HP for computers, and Levis and Nix for blue jeans. In the main study, 237 college students in the metropolitan area were surveyed to measure their brand awareness, perceived quality, brand image, and brand loyalty toward the selected two brands of each product type. The subjects were divided into two groups: one group (121 subjects) for computers, the other (116 subjects) for blue jeans. The survey questionnaires for the study included four parts: five questions on brand awareness and four questions each on perceived quality, brand image, and brand loyalty. All questions were to be answered using 7-point Likert scales. The data collected by the survey were processed to assess reliability and validity, and the causal relationships were analyzed to verify the hypotheses using the AMOS 7 program, a tool for analyzing structural equation modeling. A confirmatory factor analysis assessed the appropriateness of the measurement model, and the fit indices denoted that the model was satisfactory. The relationships among the components of brand equity were also analyzed using AMOS 7. The fit indices of the structural model denoted that it was also satisfactory. The paths in the structural model as will be seen in Figure 2 show that perceived quality affects brand image positively, but that brand awareness does not affect brand image. Moreover, it shows that brand awareness, perceived quality, and brand image are positively related with brand loyalty, and that this relationship is moderated by product type. In the case of utilitarian products, perceived quality has relatively more influence on brand loyalty. Conversely, in the case of hedonic products, brand image has relatively more influence on brand loyalty. The results of this empirical study contribute toward the advancement of our understanding of the relationships among the components of brand equity and expand the theoretical underpinnings for brand equity measurement. It also helps further our understanding of the effect of product type on customer-based brand equity. In a marketing management practice perspective, these results may provide managerial implications for building and maintaining brand equity effectively.

An Assessment of Post-Injection Transmission Measurement for Attenuation Correction With Rotating Pin Sources in Positron Emission Tomography (양전자방출단층촬영(PET)에서 회전 핀선원과 투과 및 방출 동시 영상 방법을 이용한 감쇠보정 방법 특성에 관한 고찰)

  • Lee, J.R.;Choi, Y.;Lee, K.H.;Kim, S.E.;Chi, D.Y.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.533-540
    • /
    • 1995
  • Attenuation correction is important in producing quantitative positron emission tomography (PET) images. Conventionally, photon attenuation effects are corrected using transmission measurements performed before tracer administration. The pre-injection transmission measurement approach may require a time delay between transmission and emission scans for the tracer studies requiring a long uptake period, about 45 minutes for F-18 deoxyglucose study. The time delay will limit patient throughput and increase the likelihood of patient motion. A technique lot performing simultaneous transmission and emission scans (T+E method) after the tracer injection has been validated. The T+E method substracts the emission counts contaminating the transmission measurements to produce accurate attenuation correction coefficients. This method has been evaluated in experiments using a cylindrical phantom filled with background water (5750 cc) containing $0.4{\mu}Ci/cc$ of F-18 fluoride ion and one insert cylinder (276 cc) containing $4.3{\mu}Ci/cc$. GE $Advance^{TM}$ PET scanner and Ge-68 rotating pin sources for transmission scanning were used for this investigation. Post-injection transmission scan and emission scan were peformed alternatively over time. The error in emission images corrected using post-infection transmission scan to emission images corrected transmission scan was 2.6% at the concentration of $1.0{\mu}Ci/cc$. No obvious differences in image quality and noise were apparent between the two images. The attenuation correction can be accomplished with post-injection transmission measurement using rotating pin sources and this method can significantly shorten the time between transmission and omission scans and thereby reduce the likelihood of patient motion and increase scanning throughput in PET.

  • PDF

Measurement of Backscattering Coefficients of Rice Canopy Using a Ground Polarimetric Scatterometer System (지상관측 레이다 산란계를 이용한 벼 군락의 후방산란계수 측정)

  • Hong, Jin-Young;Kim, Yi-Hyun;Oh, Yi-Sok;Hong, Suk-Young
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.2
    • /
    • pp.145-152
    • /
    • 2007
  • The polarimetric backscattering coefficients of a wet-land rice field which is an experimental plot belong to National Institute of Agricultural Science and Technology in Suwon are measured using ground-based polarimetric scatterometers at 1.8 and 5.3 GHz throughout a growth year from transplanting period to harvest period (May to October in 2006). The polarimetric scatterometers consist of a vector network analyzer with time-gating function and polarimetric antenna set, and are well calibrated to get VV-, HV-, VH-, HH-polarized backscattering coefficients from the measurements, based on single target calibration technique using a trihedral corner reflector. The polarimetric backscattering coefficients are measured at $30^{\circ},\;40^{\circ},\;50^{\circ}\;and\;60^{\circ}$ with 30 independent samples for each incidence angle at each frequency. In the measurement periods the ground truth data including fresh and dry biomass, plant height, stem density, leaf area, specific leaf area, and moisture contents are also collected for each measurement. The temporal variations of the measured backscattering coefficients as well as the measured plant height, LAI (leaf area index) and biomass are analyzed. Then, the measured polarimetric backscattering coefficients are compared with the rice growth parameters. The measured plant height increases monotonically while the measured LAI increases only till the ripening period and decreases after the ripening period. The measured backscattering coefficientsare fitted with polynomial expressions as functions of growth age, plant LAI and plant height for each polarization, frequency, and incidence angle. As the incidence angle is bigger, correlations of L band signature to the rice growth was higher than that of C band signatures. It is found that the HH-polarized backscattering coefficients are more sensitive than the VV-polarized backscattering coefficients to growth age and other input parameters. It is necessary to divide the data according to the growth period which shows the qualitative changes of growth such as panicale initiation, flowering or heading to derive functions to estimate rice growth.

Reverse engineering technique on the evaluation of impression accuracy in angulated implants (경사진 임플란트에서 임플란트 인상의 정확도 평가를 위한 역공학 기법)

  • Jung, Hong-Taek;Lee, Ki-Sun;Song, So-Yeon;Park, Jin-Hong;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.261-270
    • /
    • 2021
  • Purpose. The aim of this study was (1) to compare the reverse engineering technique with other existing measurement methods and (2) to analyze the effect of implant angulations and impression coping types on implant impression accuracy with reverse engineering technique. Materials and methods. Three different master models were fabricated and the distance between the two implant center points in parallel master model was measured with different three methods; digital caliper measurement (Group DC), optical measuring (Group OM), and reverse engineering technique (Group RE). The 90 experimental models were fabricated with three types of impression copings for the three different implant angulation and the angular and distance error rate were calculated. One-way ANOVA was used for comparison among the evaluation methods (P < .05). The error rates of experimental groups were analyzed by two-way ANOVA (P < .05). Results. While there was significant difference between Group DC and RE (P < .05), Group OM had no significant difference compared with other groups (P > .05). The standard deviations in reverse engineering were much lower than those of digital caliper and optical measurement. Hybrid groups had no significant difference from the pick-up groups in distance error rates (P > .05). Conclusion. The reverse engineering technique demonstrated its potential as an evaluation technique of 3D accuracy of impression techniques.

Characterization of the a-Se Film for Phosphor based X-ray light Modulator (형광체 기반 X선 광 변조기를 위한 비정질 셀레늄 필름 특성)

  • Kang, Sang-Sik;Park, Ji-Koon;Cho, Sung-Ho;Cha, Byung-Youl;Shin, Jung-Wook;Lee, Kun-Hwan;Mun, Chi-Woong;Nam, Sang-Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.306-309
    • /
    • 2007
  • PXLM(Phosphor based x-ray light modulator) has a combined structure by phosphor, photoconductor, and liquid crystal and it can realize x-ray image of high resolution in clinical diagnosis area. In this study, we fabricated a photoconductor and investigated electrical and optical properties to confirm application possibility of radiator detector of PXLM structure. As photoconductor, amorphous selenium(a-Se), which is used most in DR(Digital radiography) of direct conversion method, was used and for formation of thin film, it was formed as $20{\mu}m-thick$ by using thermal vacuum evaporation system. For a produced a-Se film, through XRD(X-ray diffraction) and SEM(Scanning electron microscope), we investigated that amorphous structure was uniformly established and through optical measurement, for visible light of 40 $0\sim630nm$, it had absorption efficiency of 95 % and more. After fabricated a-Se film on the top of ITP substrate, hybrid structure was manufactured through forming $Gd_2O_3:Eu$ phosphor of $270{\mu}m-thick$ on the bottom of the substrate. As the result to confirm electrical property of the manufactured hybrid structure, in the case of appling $10V/{\mu}m$, leakage current of $2.5nA/cm^2$ and x-ray sensitivity of $7.31nC/cm^2/mR$ were investigated. Finally, we manufactured PXLM structure combined with hybrid structure and liquid crystal cell of TN(Twisted nematic) mode and then, investigated T-V(Transmission vs. voltage) curve of external light source for induced x-ray energy. PXLM structure showed a similar optical response with T-V curve that common TN mode liquid crystal cell showed according to electric field increase and in appling $50\sim100V$, it showed linear transmission efficiency of $12\sim18%$. This result suggested an application possibility of PXLM structure as radiation detector.

Required Mowing Power and Bale Density of Miscanthus × Giganteus for Field Biomass Harvesting using Different Methods

  • Jun, Hyeon-Jong;Choi, Il-Su;Kang, Tae-Gyoung;Choi, Yong;Choi, Duck-Kyu;Lee, Choung-Keun
    • Journal of Biosystems Engineering
    • /
    • v.39 no.4
    • /
    • pp.253-260
    • /
    • 2014
  • Purpose: This study investigated the harvesting properties of the giant miscanthus (Miscanthus ${\times}$ giganteus) to measure the required mowing power for different stem conditioning methods in order to shorten the drying time after mowing and the bale density so that the crop can be used as biomass in the winter season. Methods: The required mowing power and bale density were measured using a power measurement device, three different mower-conditioners, and a mid-sized round baler under different working speeds and conditioning methods. Results: For the various mower-conditioners, the average stem length from mowing was 0.86-0.91 m, and the available working speed was 1.6 m/s. The steel roller-type mower-conditioner showed better stem conditioning but could not mow over a working speed of 1.6 m/s. The required average power of the mower-conditioners varied from 23.8 kW for the steel roller-type rotary disk mower-conditioner with a working width of 2.4 m to 37.2 kW for the flail-type rotary disk mower-conditioner with a working width of 3.2 m at a working speed of 1.6 m/s. The bale densities were $155.8-172.2kg/m^3$. The highest bale density was measured for stems with no conditioning and a moisture content of 11.3% (d.b.) mowed by the rotary disk mower. The bale density was affected by the mowing method because of the low moisture content of the miscanthus stems. Conclusions: In terms of the working performance and conditioning statue, the steel roller-type mower-conditioner is a better choice at a working width of 2.4 m, while the flail finger-type mower-conditioner is better at a working width of 3.2 m. The type of mower-conditioner used for giant miscanthus harvesting should be determined by considering the harvest area, workable period, and working performance of a mower-conditioner and baler during the winter.

Physical Properties of High-Solid Coatings with Acrylic Resins Containing Acetoacetoxy Group and Allophanate-Trimer (Acetoacetoxy기 함유 아크릴수지와 Allophanate-Trimer에 의한 하이솔리드 도료의 도막물성)

  • Jo Hye-Jin;Shim Il-Woo;Park Hong-Soo;Kim Seung-Jin;Kim Seong-Kil
    • Polymer(Korea)
    • /
    • v.30 no.3
    • /
    • pp.230-237
    • /
    • 2006
  • Copolymers(HSA-98-20, HSA-98-0, HSA-98+20) which we acrylic resin containing 80% solid content were synthesized by the reaction of monomers, including methyl methacrylate, n-butyl acrylate, and 2-hydroxyethyl acrylate with a functional monomer, acetoacetoxyethyl methacrylate (AAEM), which nay give improvements in cross-linking density and physical properties of films. The physical properties of prepared acrylic resins, containing AAEM, are as follows viscosities, $1420\sim5760cps$ ; number average molecular weight, $2080\sim2300g/mol$; polydispersity index, $2.07\sim2.19$ ; and conversions, $88\sim93%$. In the next step, high-solid coatings (HSA-98-20C, HSA-98-0C, HSA-98+20C) were prepared by the curing reaction between acrylic resins containing 80% solid content and isocyanate at room temperature. Various properties were examined on the film coated with the prepared high-solid coatings. The introduction of AAEM to the coatings enhanced the abrasion resistance and solvent resistance, which indicated the possible use of high- solid coatings for top-coating materials of automobile. Since the curing by viscoelastic measurement occurred in sequence of HSA-98+20C > HSA-98-0C > HSA-98-20C, it was concluded that the curing rates became faster with incresing $T_g$ values.