• Title/Summary/Keyword: 2-D measurement

Search Result 3,175, Processing Time 0.04 seconds

Water Repellent Finishes of Polyester Fiber Using Glow Discharge (글로우방전을 이용한 폴리에스테르섬유의 발수가공)

  • Mo, Sang Young;Kim, Gi Lyong;Kim, Tae Nyun;Chun, Tae Il
    • Textile Coloration and Finishing
    • /
    • v.5 no.4
    • /
    • pp.29-41
    • /
    • 1993
  • In order to surface Hydrophobilization of Poly(ethylene terephthalate) (PET) fiber samples were treated in the atmosphere of CF$_{4}$ or $C_{2}$F$_{6}$glow discharge. The sample used in this study was PET film which is 75$\mu$m thick made by Teijin, O-Type(Japan). The cleaned samples were placed in plasma reactor made of pyrex glass cylinder, and plasma processing was carried out by glow discharge of CF$_{4}$ or $C_{2}$F$_{6}$ gas, being continuously fed by gas flow and continuously pumped out by a vacuum system. Electric power source for generate plasma state was sustained alternating current(60Hz) and voltage was sustained 600 volt. The duration of plasma treatment varied from 15 to 120 seconds except special case, the monomer gase pressure varied from 0.02 to 0.3 Torr and power range was 10 to 90 watts. The hydrophobic features of changed PET surface were evaluated by contact angle measurement and surface chemical characteristics were analyzed by ESCA. Results can be summerized as follows. 1. The most favorable setting position of substrate was the center area between the two electrodes. 2. $C_{2}$F$_{6}$ discharge current was lower than that of CF$_{4}$ when same voltage was sustained. Treated efficiency between CF$_{4}$ and $C_{2}$F$_{6}$ did not revealed significant differences under same electric power(wattage). 3. When monomer pressure is very low below 0.02 torr, as though substrate is exposed to CF$_{4}$ or $C_{2}$F$_{6}$ plasma, it tend to be hydrophilic through a little of fluorine bond and a great deal of oxidizing reaction. 4. There brought good hydrophobilization when monomer pressure was more 0.1 torr and duration of glow discharge treatment was over 45 seconds. When monomer pressure was too high, discharge current became low. Although prolong the duration, there was no more high hydrophobilization. 5. According to ESCA analysis, there were a little CF bond and a prevailing CF$_{2}$ bond in CF$_{4}$-treated substrate. There were CF$_{3}$, a little CF and a prevailing CF$_{2}$ bond in $C_{2}$F$_{6}$-treated substrate.d substrate.

  • PDF

The Prevalence of Obesity, Serum Lipid Levels and Age at Menarche in Adolescent Female Athletes (청소년 여자운동선수에서 비만, 혈청 지질, 초경 연령에 관한 분석)

  • Kang, Bo Young;Kim, Yang Kyong;Hong, Young Jin;Son, Byong Kwan;Chang, Kyung Ja;Kim, Soon Ki
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.1
    • /
    • pp.21-26
    • /
    • 2005
  • Purpose : The aim of this study is to find the prevalence of obesity, the serum lipid levels and the age at menarche in adolescent female athletes and to examine the effects of exercise in adolescent stage. Methods : With a questionnaire regarding their age at menarche, physical measurement, body fat, and blood samples of the serum lipid levels to evaluate the hyperlipidemia were obtained from adolescent female athletes(n=107) and general adolescent students(n=650) who didn't exercise at regular intervals, aged 12 to 18 years. Results : The mean weight in the athletes' group was $53.3{\pm}7.3kg$ which was similar with $54.3{\pm}8.0kg$ in the control group. The mean height in the athletes' group was $161.4{\pm}5.4cm$, which was taller than $158.9{\pm}5.3cm$ in the control group. The prevalence of obesity by obesity index, body fat, and BMI in the athletes' group were significantly lower than in control group. There was no significant difference in age at menarche between two groups($12.6{\pm}1.3$, $12.9{\pm}1.2$). The levels of cholesterol, LDL cholesterol, and HDL cholesterol in the athletes' group were higher than in the control group. The levels of triglyceride in the athletes' group was lower than in control group. Conclusion : These data suggest the importance of exercise in adolescents for the prevention of obesity since it may reduce body fat and increase the height. There was no negative effect of exercise on the age at menarche. We think that more controlled assessment of nutrition, diet habit, hormonal effect and height are warranted to find the correlation with hyperlipidemia and exercise at the adolescent stage.

Analysis on the Dosimetric Characteristics of Tangential Breast Intensity Modulated Radiotherapy (유방암의 접선 세기조절 방사선치료 선량 특성 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Wong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.219-228
    • /
    • 2012
  • The tangential breast intensity modulated radiotherapy (T-B IMRT) technique, which uses the same tangential fields as conventional 3-dimensional conformal radiotherapy (3D-CRT) plans with physical wedges, was analyzed in terms of the calculated dose distribution feature and dosimetric accuracy of beam delivery during treatment. T-B IMRT plans were prepared for 15 patients with breast cancer who were already treated with conventional 3D-CRT. The homogeneity of the dose distribution to the target volume was improved, and the dose delivered to the normal tissues and critical organs was reduced compared with that in 3D-CRT plans. Quality assurance (QA) plans with the appropriate phantoms were used to analyze the dosimetric accuracy of T-B IMRT. An ionization chamber placed at the hole of an acrylic cylindrical phantom was used for the point dose measurement, and the mean error from the calculated dose was $0.7{\pm}1.4%$. The accuracy of the dose distribution was verified with a 2D diode detector array, and the mean pass rate calculated from the gamma evaluation was $97.3{\pm}2.9%$. We confirmed the advantages of a T-B IMRT in the dose distribution and verified the dosimetric accuracy from the QA performance which should still be regarded as an important process even in the simple technique as T-B IMRT in order to maintain a good quality.

AN EXPERIMENTAL STUDY OF NEWLY DESIGNED IMPLANT WITH RBM SURFACE IN THE RABBIT TIBIA : RESONANCE FREQUENCY ANALYSIS AND REMOVAL TORQUE STUDY

  • Won Mi-Kyoung;Park Chan-Jin;Chang Kyoung-Soo;Kim Chang-Whe;Kim Yung-Soo;Isa Zakiahbt Mohd;Ariffin Yusnidar Tajul
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.6
    • /
    • pp.720-731
    • /
    • 2003
  • Statement of problem. The importance of fixture design and surface treatment. Purpose. The clinical success of dental in plants is affected by many factors such like as degree of osseointegration, the effective load dispersion for the prostheses, and a lot of attempts have been made to overcome the difficulties. In this study, efforts were made to find the possibility of clinical acceptance of the dental implants of newly designed surface and resorbable blast media surcace. Materials and methods. In this study, two groups of custom-made, screw-shaped implants were prepared. The first with the consisting of Branemark clone design and the other with the new design. These implants were divided into four groups according to the kinds of surface treatment. Four implants($AVANA^{(R)}$, Osstem, Busan, Korea)of each group were installed in twenty rabbits. Group A was consisted of Branemark done implant left as machined, Group B with Branemark clone implants with RBM(Resorbable blast media) surface, Group C with newly designed implants left as machined and Group D with newly designed implants with RBM surface. One of the twenty rabbits died from inflammation and the observation was made for six weeks. Specimens from four groups were observed using scanning electron microscopy with 40, 100, 1000 magnification power and microsurface structures were measured by white-light scanning interferometry for three dimensional surface roughness measurements(Accura $2000^{(R)}$, Intek-Plus, Korea.). Removal torque was measured in 17 rabbits using digital torque gauge(MGT 12R, Mark-10 corp., NY, U.S.A.) immediately after the sacrifice and two rabbits were used for the histologic preparation(EXAKT $310^{(R)}$, Heraeus Kulzer, wehrheim, Germany) of specimens and observed under light microscope. Resonance frequency measurement($Osstell^{(R)}$) was taken with the 19 rabbits at the beginning of the implant fixation and immediately after the sacrifice. Results. Following results were taken from the experiment. 1. The surface of the RBM implants as seen with SEM had rough and irregular pattern with reticular formation compared to that of fumed specimens showing different surface topographies. 2. The newly designed implant with RBM surface had high removal torque value among four groups with no statistical significance. The average removal torque was $49.95{\pm}6.70Ncm$ in Group A, $51.15{\pm}4.40Ncm$ in Group B, $50.78{\pm}9.37Ncm$ in Group C, $51.09{\pm}4.69Ncm$ in Group D. 3. The RFA values were $70.8{\pm}4.3Hz$ in Group A, $71.8{\pm}3.1Hz$ in Group B, $70.9{\pm}2.5Hz$, $72.7{\pm}2.5Hz$ in Group D. Higher values were noted in the groups which had surface treatment compared to the untreated groups with no statistical significance. 4. The results from the histomorphometric evaluation showed a mean percentage of bone-to-implant contact of $45{\pm}0.5%$ in Group A, $55{\pm}3%$ in Group B, $49.5{\pm}0.5%$ in Group C, and $55{\pm}3%$ in Group D. Quite amount of newly formed bone were observed at the surface RBM-treated implants in bone marrow space.

Quantitative Assessment Technology of Small Animal Myocardial Infarction PET Image Using Gaussian Mixture Model (다중가우시안혼합모델을 이용한 소동물 심근경색 PET 영상의 정량적 평가 기술)

  • Woo, Sang-Keun;Lee, Yong-Jin;Lee, Won-Ho;Kim, Min-Hwan;Park, Ji-Ae;Kim, Jin-Su;Kim, Jong-Guk;Kang, Joo-Hyun;Ji, Young-Hoon;Choi, Chang-Woon;Lim, Sang-Moo;Kim, Kyeong-Min
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.42-51
    • /
    • 2011
  • Nuclear medicine images (SPECT, PET) were widely used tool for assessment of myocardial viability and perfusion. However it had difficult to define accurate myocardial infarct region. The purpose of this study was to investigate methodological approach for automatic measurement of rat myocardial infarct size using polar map with adaptive threshold. Rat myocardial infarction model was induced by ligation of the left circumflex artery. PET images were obtained after intravenous injection of 37 MBq $^{18}F$-FDG. After 60 min uptake, each animal was scanned for 20 min with ECG gating. PET data were reconstructed using ordered subset expectation maximization (OSEM) 2D. To automatically make the myocardial contour and generate polar map, we used QGS software (Cedars-Sinai Medical Center). The reference infarct size was defined by infarction area percentage of the total left myocardium using TTC staining. We used three threshold methods (predefined threshold, Otsu and Multi Gaussian mixture model; MGMM). Predefined threshold method was commonly used in other studies. We applied threshold value form 10% to 90% in step of 10%. Otsu algorithm calculated threshold with the maximum between class variance. MGMM method estimated the distribution of image intensity using multiple Gaussian mixture models (MGMM2, ${\cdots}$ MGMM5) and calculated adaptive threshold. The infarct size in polar map was calculated as the percentage of lower threshold area in polar map from the total polar map area. The measured infarct size using different threshold methods was evaluated by comparison with reference infarct size. The mean difference between with polar map defect size by predefined thresholds (20%, 30%, and 40%) and reference infarct size were $7.04{\pm}3.44%$, $3.87{\pm}2.09%$ and $2.15{\pm}2.07%$, respectively. Otsu verse reference infarct size was $3.56{\pm}4.16%$. MGMM methods verse reference infarct size was $2.29{\pm}1.94%$. The predefined threshold (30%) showed the smallest mean difference with reference infarct size. However, MGMM was more accurate than predefined threshold in under 10% reference infarct size case (MGMM: 0.006%, predefined threshold: 0.59%). In this study, we was to evaluate myocardial infarct size in polar map using multiple Gaussian mixture model. MGMM method was provide adaptive threshold in each subject and will be a useful for automatic measurement of infarct size.

Clinical Usefulness and the Accuracy of Korean Reference Equation for Diffusing Capacity (한국인 폐확산능 정상예측식의 임상적 유용성과 정확성)

  • Ra, Seung Won;Park, Tai Sun;Hong, Yoonki;Hong, Sang-Bum;Shim, Tae Sun;Lim, Chae-Man;Lee, Sang-Do;Koh, Younsuck;Kim, Woo Sung;Kim, Dong-Soon;Kim, Won Dong;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.2
    • /
    • pp.80-86
    • /
    • 2008
  • Background: Park et al. developed the Korean reference equation for the measurement of diffusing capacity in 1985. However, the equation has not been widely used in Korea and foreign reference equations have been popularly used. We intended to compare the clinical usefulness and the accuracy of the the Korean reference equation (Park's equation) with that of the foreign equation (Burrows' equation) that is commonly used in Korea. Methods: 1. Evaluation of clinical usefulness; Among 1,584 patients who underwent diffusing capacity ($D_LCO$) at the Asan Medical Center from July to December 2006, group A subjects included 276 patients who had different interpretations of $D_LCO$ in trials employing Burrows' equation and Park's equation. Clinical assessment was decided by consensus of two respiratory physicians. In order to evaluate the clinical usefulness of Burrows' equation and Park's equation, agreement of clinical assessment and $D_LCO$ interpretation were measured. 2. Evaluation of accuracy; Group B subjects were 81 patients with interstitial lung disease (ILD) and 39 normal subjects. The 81 ILD patients were diagnosed following a surgical lung biopsy. The accuracy of diagnosing ILD as well as sensitivity and specificity were evaluated according to the use of the reference equations (Burrows' equation and Park's equation) for $D_LCO$. Results: Agreement between clinical assessment and interpretation of $D_LCO$ was 22% for the use of Burrows' equation and 78% for the use of Park's equation. The sensitivity and specificity of the Burrows' equation for diagnosing ILD were 64.2% and 100%. The sensitivity and specificity of the Park's equation for diagnosing ILD were 90.1% and 100%. The sensitivity of the Park's equation for diagnosing ILD was significantly higher than that of Burrows' equation (p<0.001). Conclusion: The Korean reference equation (Park's equation) was more clinically useful and had higher sensitivity for diagnosing ILD than the foreign reference equation (Burrows' equation).

A Study on the Method for Quantifying CO2 Contents in Decarbonated Slag Materials by Differential Thermal Gravimetric Analysis (DTG 분석법을 활용한 슬래그류 비탄산염 재료의 CO2 정량 측정방법 연구)

  • Jae-Won Choi;Byoung-Know You;Yong-Sik Chu;Min-Cheol Han
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.12 no.1
    • /
    • pp.8-16
    • /
    • 2024
  • Limestone (CaCO3, calcium carbonate), which is used as a raw material in the portland cement and steel industry, emits CO2 through decarbonation by high temperatures in the manufacturing process. To reduce CO2 emissions by the use of raw materials like limestone, it has been proposed to replace limestone with various industrial by-products that contain CaO but less or none of the carbonated minerals, that cause CO2 emissions. Loss of Ignition (LOI), Thermogravimetric analysis (TG), and Infrared Spectroscopy (IR) are used to quantitative the amount of CO2 emission by using these industrial by-products, but CO2 emissions can be either over or underestimated depending on the characteristics of by-product materials. In this study, we estimated CO2 contents by LOI, TG, IR and DTG(Differential Thermogravimetric analysis) of calcite(CaCO3) and samples that contain CO2 in the form of carbonate and whose weight increases by oxidation at high temperatures. The test results showed for CaCO3 samples, all test methods have a sufficient level of reliability. On the other hand, for the CO2 content of the sample whose weight increases at high temperature, LOI and TG did not properly estimate the CO2 content of the sample, and IR tended to overestimate compared to the predicted value, but the estimated result by DTG was close to the predicted valu e. From these resu lts, in the case of samples that contain less than a few percent of CO2 and whose weight increases during the temperature that carbonate minerals decompose, estimating the CO2 content using DTG is a more reasonable way than LOI, TG, and IR.

3-dimensional Coordinate Measurement by Pulse Magnetic Field Method (자기적 방법을 이용한 3차원 좌표 측정)

  • Im, Y.B.;Cho, Y.;Herr, H.B.;Son, D.
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.6
    • /
    • pp.206-211
    • /
    • 2002
  • We have constructed a new kind of magnetic motion capture sensor based on the pulse magnetic field method. 3-orthogonal magnetic pulse fields were generated in turns only one period of sinusoidal waveform using 3-orthogonal magnetic dipole coils, ring counter and analog multiplier. These pulse magnetic fields were measured with 3-orthogonal search coils, of which induced voltages by the x-, y-, and l-dipole sources using S/H amplifier at the time position of maximum induced voltage. Using the developed motion capture sensor, we can measure position of sensor with uncertainty of ${\pm}$0.5% in the measuring range from ${\pm}$0.5 m to ${\pm}$1.5 m.

Relationship between Immunoglobulin E, Eosinophil Count and Allergens in Allergic Patients (알레르기 환자에서 Immunoglobulin E와 Eosinophil count 및 Allergen과의 관련성)

  • Yoon, In-Sook;Kwon, Se-Young
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.4
    • /
    • pp.236-246
    • /
    • 2009
  • As the allergic diseases in patients are increasing, it is important to find out the allergens. A multiple antigen simultaneous test(MAST) is a simple method for in vitro measurement of allergen-specific IgE antibodies. This study was performed to evaluate the relationship between allergen-specific IgE antibodies, serum total IgE and peripheral eosinophil count in the allergic patients. According to the results of the study, the total IgE positive rate(above class 2) from the inhalent is 96.97%, and that from food panel is 98.06%. The research showed that the positive rate of the allergen-specific IgE was House dust 51.52%, D. farinae 45.46%, Cat 31.99% in inhalent panel, and 55.34%, 42.72%, 34.96% in food panel. Serum total IgE was associated with allergy, however, allergy was not always associated with eosinophilia.

The Analysis of the Airplane Flutter on Low Band Television Broadcasting Signal

  • Wonggeeratikun, A.;Noppanakeepong, S.;Leelaruji, N.;Hemmakorn, N.;Moriya, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1648-1653
    • /
    • 2003
  • The paper studies effect of quasi-periodic or airplane flutter phenomenon on television broadcasting signal. Airplane flutter is a very important problem. It causes the receiving antenna to receive both direct signal by the Tx (Transmitter antenna) and reflected signal scattered by the airplane with phase delay. The sum of two signals results in fading, sometime collapse and distortion of picture on TV screen. We performed measurement and modeling this phenomenon on TV signal when the airplane flew across and range Tx and Rx (Receiver antenna). The frequency 60.75MHz (Aural frequency of CH3) is used under tests. A single scatter multipath model is introduced. It is used to duplicate some of the measured data and show the dependence of power variation on the airplane fluttering. The fluctuation of the airplane flutter phenomenon was calculated to be around 2-4dB. The Yaki antenna is used for improving airplane flutter problem because it can make high gain and high directivity.

  • PDF