• Title/Summary/Keyword: 2-D measurement

Search Result 3,175, Processing Time 0.03 seconds

The Motion Analysis of the Scaphoid, Capitate and Lunate During Dart-Throwing Motion Using 3D Images (3차원 영상을 이용한 다트 던지기 운동에서의 주상골, 유두골, 월상골의 움직임 분석)

  • Park, Chan-Soo;Kim, Kwang-Gi;Kim, Yu-Shin;Jeong, Chang-Bu;Jang, Ik-Gyu;Lee, Sang-Lim;Oh, Su-Chan;Yu, Do-Hyun;Baek, Goo-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.144-150
    • /
    • 2011
  • The primary purpose of this study was to analyze the motion of the scaphoid, capitate, and lunate during dart-throwing motion by three-dimensional modeling. Five series of CT images of five normal right wrists were acquired from five motion steps from radial extension to ulnar flexion in the dart-throwing motion plane. Segmentation and three-dimensional modeling of bones from CT images was performed using Analyze. Distances among centroids of the scaphoid, capitate and lunate and angles between principal axes of three carpal bones were calculated to analyze the motion by using MATLAB. As the wrist motion changed from radial extension to ulnar flexion, the distance between two adjacent bones decreased. The scaphoid and lunate rotated less than the capitates during dart-throwing motion. This study reports the Three-dimensional in vivo measurement of carpal motion using CT images.

Assessment technology for spatial interaction of Artificial Monitoring System through 3-dimensional Simulation (3차원 시뮬레이션을 이용한 인위감시체계의 공간대응성능 평가기술)

  • Kim, Suk-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1426-1433
    • /
    • 2015
  • CCTV-applied monitoring is an effective measure to suppress potential crimes and record objective relationship; however, there is no methodology that can quantitatively compare and assess the afore-mentioned effects. Thus, this study intended to construct the methodology and analysis application that can measure the changes in the space-corresponding performance of CCTVs depending on installation measures by using 3-dimenstional virtual simulation technology. For analysis, the raster-based Isovist theory was 3-dimensionally expanded and the amount of incident sight line to each point was accumulated. At the same time, the amount of overlapped monitoring in the CCTV cameras that were connected to each measurement node was accumulated for cross-analysis. By applying the examples and analyzing the results, it was possible to construct an analysis application in use of collision detection model and quantify the changes of monitoring performance depending on positioning alternative of the cameras. Moreover, it enabled intuitive review and supplementation by reproducing visible shadow areas in a graph.

A Study of Weldability for Pure Titanium by Nd:YAG Laser(III) - Weld Properties of Edge Welding - (순티타늄판의 Nd:YAG 레이저 용접성에 관한 연구(III) - 에지 용접 특성 -)

  • Kim, Jong-Do;Kil, Byung-Lea;Kwak, Myung-Sub;Song, Moo-Keun
    • Journal of Welding and Joining
    • /
    • v.27 no.6
    • /
    • pp.74-79
    • /
    • 2009
  • Titanium and titanium alloy can be reproduced immediately even if oxide films($TiO_2$) break apart in sea water. Therefore, since titanium demonstrates large specific strength and outstanding resistance to stress corrosion cracking, crevice corrosion, pitting and microbiologically influenced corrosion in sea water environment, it has been widely applied to heat exchanger for ships. In particular, with excellent elongation, pure titanium may be deemed as optimal material for production of heat exchanger plate which is used with wrinkles formed for efficient heat exchange. Conventional plate type heat exchanger prevented leakage of liquid through insertion of gasket between plates and mechanical tightening by bolts and nuts, but in high temperature and high pressure environment, gasket deterioration and leakage occur, so heat exchanger for LPG re-liquefaction device etc do not use gasket but weld heat exchanger plate for use. On the other hand, since welded plate cannot be separated, it is important to obtain high quality reliable welds. In addition, for better workability and production performance, lasers that can obtain weldment with large aspect ratio and demonstrate fast welding speed even in atmospheric condition not in vacuum condition are used in producing products. So far, 1st report and 2nd report compared and analyzed embrittlement degrees by bead colors of weldment through quantitative analysis of oxygen and nitrogen and measurement of hardness as fundamental experiment for the evaluation of titanium laser welding, and evaluated the welding performance and mechanical properties of butt welding. This study welded specimens in various conditions by using laser and GTA welding machine to apply edge welding to heat exchanger, and evaluated the mechanical strength through tensile stress test. As a result of tensile test, laser weldment demonstrated tensile strength 4 times higher than GTA welds, and porosity could be controlled by increasing and decreasing slope of laser power at overlap area.

Study to Propose the Suitable Reproducing Sound Level of SAFRS (능동형 음장조성시스템 연출음의 적정 소리레벨 제시를 위한 연구)

  • Jeon, Ji-Hyeon;Shin, Yong-Gyu;Kook, Chan;Jang, Gil-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.6 s.123
    • /
    • pp.547-552
    • /
    • 2007
  • SAFRS(spontaneous acoustic field reproduction system) is a system to sense changes of surroundings and produce sounds which can go well with environment elements sensed by the system in to the space. The sounds were judged by individual evaluation and, the classification of the preferred sounds according to the mood of the space was suggested in the former study. Effectiveness of SAFRS with field application was validated by prior studies which dealt with researching acoustic environment, evaluating images of sounds, and rating environment with existence and nonexistence of sound resources such as fountains and the system after applied in D university. In this study, for more effective field application of SAFRS, research for the acoustic environment around sound resources and subjective evaluation of the preference of the sounds from the resources were made and it was considered that the results of the experiments should be primary information to propose proper sound level to be offered by the system. The results of the study are as follows; 1) It was considered that the ambience of the center road was dependent upon produced sounds by the system and water sounds of the fountain and that of walk way was mostly dependent upon produced sounds. 2) The results of the subjective evaluation showed that the distance from sound resources was suggestive; the more distant from produced sounds the less full and clear the sounds, the less distant from the sounds of water the more delight and idyllic ambience, and the less distant from the forest the more idyllic ambient and diversity. 3) The results upwards were telling that an average value of six elements for the evaluation was even at the place set back 10.2m from center road and walk way. And harmony of all sounds of the place should be considered to propose suitable sound level of SAFRS.

Volumetric Blood Velocity Measurement on Multigate Pulsed Doppler System based on the Single Channel RF Sampling using the Optimized Sampling Factor (최적화된 샘플링 인수를 갖는 단일 채널 RF 샘플링 방식의 다중점 펄스 도플러 시스템을 사용한 혈류 속도분포 측정)

  • 임춘성;민경선
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.143-152
    • /
    • 1998
  • In this paper, we present the performances of a Doppler system using single channel RF(Radio Frequency) sampling. This technique consists of undersampling the ultrasonic blood backscattered RF signal on a single channel. Conventional undersampling method in Doppler imaging system have to use a minimum of two identical parallel demodulation channels to reconstruct the multigate analytic Doppler signal. However, this system suffers from hardware complexity and problem of unbalance(gain and phase) between the channels. In order to reduce these problems, we have realized a multigate pulsed Doppler system using undersampling on a single channel, It requires sampling frequency at $4f_o$(where $f_o$ is the center frequency of the transducer) and 12bits A/D converter. The proposed " single-Channel RF Sampling" method aims to decrease the required sampling frequency proportionally to $4f_o$/(2k+1). To show the influence of the factor k on the measurements, we have compared the velocity profiles obtained in vitro and in vivo for different intersequence delays time (k=0 to 10). We have used a 4MHz center frequency transducer and a Phantom Doppler system with a laminar stationary flow. The axial and volumetric velocity profiles in the vessel have been computed according to factor k and have been compared. The influence of the angle between the ultrasonic beam and the flow axis direction, and the fluid viscosity on the velocity profiles obtained for different values of k factor is presented. For experiment in vivo on the carotid, we have used a data acquisition system with a sampling frequency of 20MHz and a dynamic range of 12bits. We have compared the axial velocity profiles in systole and diastole phase obtained for single channel RF sampling factor.ng factor.

  • PDF

An Assessment of Vertebral Left Atrial Size in Relation to the Progress of Myxomatous Mitral Valve Disease in Dogs

  • Kim, Sun Hwa;Seo, Kyoung Won;Song, Kun Ho
    • Journal of Veterinary Clinics
    • /
    • v.37 no.1
    • /
    • pp.9-14
    • /
    • 2020
  • Left atrial enlargement (LAE) is an important diagnostic factor in dogs with myxomatous mitral valve disease (MMVD). It is associated with the onset of congestive heart failure (CHF). Recently, a new radiographic left atrial measurement called vertebral left atrial size (VLAS) was introduced. This can be considered as a left atrial enlargement above 2.3. It appears to be related to the severity of MMVD. However, serial changes in VLAS in relation to disease progression and improvement in patients have yet to be studied. This study aims to assess the value of VLAS as a left atrial size monitoring indicator by examining correlations with VHS, LA/Ao ratio and LVIDDN, and comparing serial changes in dogs. A total of 126 dogs were studied with their owners' consent. The dogs were classified into four MMVD groups (Control, B1, B2, C-D) following the ACVIM Guideline by performing a physical examination, radiography and echocardiography. Besides, 24 and 17 dogs were reevaluated to compare values in relation to the progression and improvement of MMVD. VLAS showed significant increase according to the progress of the MMVD stage. This was the same in the Maltese breed group. A strong positive correlation was found between LVIDDN, VHS, LA/Ao ratio, and VLAS. The results of this study found VLAS to be significantly different according to left atrium size, and there was a correlation between disease progression and VLAS levels in each dog. Therefore, VLAS may be used to detect changes in left atrium size as an additional monitoring index of MMVD.

The Development of a beam measurement system for improving the beam output characteristics. (빔 출력 특성 개선을 위한 빔 측정 시스템 개발)

  • Kim, Dong-Myung;Moon, Ha-jung;Hur, Min-Gu;Yang, Seung-Dae;Lee, Dong-hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.693-695
    • /
    • 2014
  • Radioactive isotopes for radiation diagnosis is production by using Cyclotron like a PET. Radioactive isotopes is influenced product yield according to shape and size of the proton beam and target irradiation position by cyclotron. And to develop a device for measuring the distribution of the beam to increase the loss of the beam. Beam measuring device is measured vertically beam current according move the two wires. In this way, by using the beam current value in each position you are able to know the cross section and location information of the beam. By scanning cross-section for X-axis Y-axis of beam acquires data of beam. Print this into 2D graph, and analyze the result. You can save this result by documentation process.

  • PDF

Reliability of cone-beam computed tomography for temporomandibular joint analysis

  • Gorucu-Coskuner, Hande;Atik, Ezgi;El, Hakan
    • The korean journal of orthodontics
    • /
    • v.49 no.2
    • /
    • pp.81-88
    • /
    • 2019
  • Objective: The aim was to assess the intraobserver and interobserver reliabilities of temporomandibular joint linear measurements and condylar shape classifications performed with cone-beam computed tomography (CBCT). Methods: CBCT images of 30 patients were measured at two different time points by two orthodontists using the Dolphin 3D program (n = 60). Anterior, posterior, and superior joint space measurements and sagittal joint morphology classification in the sagittal view and medial and lateral joint space and mediolateral width measurements and coronal joint morphology classification in the coronal view were recorded. Intraclass-interclass correlation coefficients (ICC) and kappa statistics were used to assess intraobserver and interobserver reliability for the measurements and morphology classifications, respectively. Results: The ICC values were good for measurements of the posterior joint space by observer I and for measurements of the posterior, medial, and lateral joint spaces by observer II, while the other intraobserver measurements were excellent. Only the mediolateral width measurements showed excellent interobserver ICC values, while the other measurements showed good interobserver ICC values. Intraobserver agreement for the sagittal morphology classifications was moderate (${\kappa}=0.479$) and almost perfect (${\kappa}=0.858$) for observers I and II, respectively, while the corresponding agreement for the coronal morphology classifications was substantial for both observers. The interobserver agreement values for sagittal and coronal morphology classifications were slight (${\kappa}=0.181$) and fair (${\kappa}=0.265$), respectively. Conclusions: Linear temporomandibular joint measurements were reproducible and reliable in both intraobserver and interobserver evaluations. However, interobserver agreement for assessments of condylar shape was low.

Analysis of the whole body shape of old-old aged males -focused on 70-85 aged males-

  • Cha, Su-Joung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.5
    • /
    • pp.81-91
    • /
    • 2019
  • In this study, 3D measurement data of 70 to 85 years old men were analyzed to investigate the body shape characteristics. and the type of the whole body of older men. Through this study, we aimed to provide basic data necessary for making good clothes for elderly men. We analyzed the body shape of elderly males using Korea 's 2015 elderly anthropometric data by SPSS Ver. 24.0. The body shape of older males was classified into four types: 'thin & long inverted triangle with thick legs', 'thick & short inverted triangle with bird legs', 'thick & long triangle with thick legs', 'thick & short triangle with thick legs'. As the age increases, the shoulders are sagging, the progressive reduction of the spine leads to a decrease in height, and the backbone refraction causes a decrease in the anterior center length and an increase in the back length. In addition, as the age increases, the chest circumference decreases and the abdomen and waist circumference increase. Considering these physical changes, it is necessary to set the length of the garment to 2-3cm shorter in the case of the aged layer. Waist and abdomen area are increased, it is considered that it will be necessary to add more margin of 2cm than general silver clothing when setting the margin amount. When setting the length of the upper body, it is considered that the front center length should be reduced and the back length should be increased to keep the bottom level. In this study, only the elderly males aged 70-85 years were included in the analysis of the whole body type. It is significant that the studies so far have been extended to those older than 70 years. Future research will need to be applied to the development of silver clothing through comparison of older men 's body shape in their 60s and 70s.

The Standard Processing of a Time Series of Imaging Spectral Data Taken by the Fast Imaging Solar Spectrograph on the Goode Solar Telescope

  • Chae, Jongchul;Kang, Juhyeong;Cho, Kyuhyoun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.46.1-46.1
    • /
    • 2018
  • The Fast Imaging Solar Spectrograph (FISS) on the Goode Solar Telescope (GST) at Big Bear Solar Observatory is the imaging Echelle spectrograph developed by the Solar Astronomy Group of Seoul National University and the Solar and Space Weather Group of Korea Astronomy and Space Science Institute. The instrument takes spectral data from a region on the Sun in two spectral bands simultaneously. The imaging is done by the organization of intensity data obtained from the fast raster scan of the slit over the field of view. Since the scan repeats many times, the whole set of data can be used to construct the movies of monochromatic intensity at arbitrary wavelengths within the spectral bands, and those of line-of-sight velocity inferred from different spectral lines. So far there are two standard observing configurations: one recording the $H{\alpha}$ line and the Ca II 8542 line simultaneously, and the other recording the Na I D2 line and Fe I 5435 line simultaneously. We have developed the procedures to produce the standard data for each observing configuration. The procedures include the spatial alignment, the correction of spectral shift of instrumental origin, and the lambdameter measurement of the line wavelength. The standard data include the movie of continuum intensity, the movies of intensity and velocity inferred from a chromospheric spectral line, the movies of intensity and velocity inferred from a photospheric line. The processed standard data will be freely available online (fiss.snu.ac.kr) to be used for research and public outreach. Moreover, the IDL procedures will be provided on request as well so that each researcher can adapt the programs for their own research.

  • PDF