• 제목/요약/키워드: 2-D duct

검색결과 156건 처리시간 0.025초

Characteristics of Heat Transfer in the Channel with Twisted Tape

  • Ahn, Soo-Whan;Kang, Ho-Keun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권3호
    • /
    • pp.122-128
    • /
    • 2007
  • Heat transfer distributions and friction factors in square channels (3.0 ${\times}$ 3.0 cm) with twisted tape inserts and with twisted tape inserts plus interrupted ribs are respectively investigated. The rib height-to-channel hydraulic diameter ratio, $e/D_h$, is kept at 0.067 and test section length-to-hydraulic diameter ratio, $L/D_h$ is 30. The square ribs are arranged to follow the trace of the twisted tape and along the flow direction defined as axial interrupted ribs. The twisted tape is 0.1 mm thick carbon steel sheet with diameter of 2.8 cm, length of 90 cm, and 2.5 turns. Two heating conditions are investigated for test channels with twisted tape inserts and rib turbulators: (1) electric heat uniformly applied to four side walls of the square duct, and (2) electric heat uniformly applied to two opposite ribbed walls of the square channel. Results show that the twisted tape with interrupted ribs provides a higher overall heat transfer performance over the twisted tape with no ribs.

채널유동에서 거친벽면이 열전달에 미치는 효과 (Effects of Rough Surfaces on Heat Transfer in Channel Flow)

  • 안수환
    • 동력기계공학회지
    • /
    • 제5권2호
    • /
    • pp.30-35
    • /
    • 2001
  • A comparison of fully developed heat transfer and friction factor characteristics has been made in rectangular ducts with one wall roughened by five different shapes. The effects of rib shape geometries and Reynolds number are examined. The rib height-to-duct hydraulic diameter, pitch-to-height ratio, and aspect ratio of channel width to height are fixed at $e/D_e=0.0476$, P/e=8, and W/H=2.33, respectively. To understand the mechanisms of the heat transfer enhancements, the measurements of the friction factors are also conducted in the smooth and rough channels. The data indicate that the triangular type rib has a substantially higher efficiency index than any other ones in the range we studied.

  • PDF

곡관부를 가지는 내부 냉각유로에서 회전수 변화에 따른 열전달 및 유동 특성 (II) - 평행한 요철배열 덕트 - (Effects of Rotation Speed on Heat Transfer and Flow in a Coolant Passage with Turning Region (II) - Parallel Ribbed Duct -)

  • 김경민;김윤영;이동현;조형희
    • 대한기계학회논문집B
    • /
    • 제29권8호
    • /
    • pp.911-920
    • /
    • 2005
  • The present study investigates heat/mass transfer and flow characteristics in a ribbed rotating passage with turning region. The duct has an aspect ratio (W/H) of 0.5 and a hydraulic diameter ($D_h$) of 26.67 mm. Rib turbulators are attached in the parallel arrangement on the leading and trailing surfaces of the passage. The ribs have a rectangular cross section of 2 m (e) $\times$ 3 m (w) and an attack angle of $70^{\circ}$. The pitch-to-rib height ratio (p/e) is 7.5, and the rib height-to-hydraulic diameter ratio (e/$D_h$) is 0.075. The rotation number ranges from 0.0 to 0.20 while the Reynolds number is constant at 10,000. To verify the heat/mass transfer augmentation, internal flow structures are calculated for the same conditions using a commercial code FLUENT 6.1. The results show that a pair of vortex cells are generated due to the symmetric geometry of the rib arrangement, and heat/mass transfer is augmented up to $Sh/Sh_0=2.9$ averagely, which is higher than that of the cross-ribbed case presented in the previous study for the stationary case. With the passage rotation, the main flow in the first-pass deflects toward the trailing surface and the heat transfer is enhanced on the trailing surface. In the second-pass, the flow enlarges the vortex cell close to the leading surface, and the small vortex cell on the trailing surface side contracts to disappear as the passage rotates faster. At the highest rotation number ($R_O=0.20$), the turn-induced single vortex cell becomes identical regardless of the rib configuration so that similar local heat/mass transfer distributions are observed in the fuming region for the cross- and parallel-ribbed case.

꼬임식 테이프가 설치된 사각 덕트에서 스월유동이 미치는 열전달과 마찰계수 (Effects of Swirl Flow Generated by Twisted Tape on Heat Transfer and Friction Factor in a Square Duct)

  • 강호근;아리바시아크리시나 부트라;안수환
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.117-120
    • /
    • 2008
  • Numerical simulations and experiment of a hydrodynamic and thermally developed turbulent flow through square ducts (3.0 ${\times}$ 3.0 cm) with twisted tape inserts and with twisted tape inserts plus interrupted ribs are conducted to investigate regionally averaged heat transfer and friction factors. Turbulent swirl flows having Reynolds numbers ranging from 8,900 to 29,000, a rib height-to-channel hydraulic diameter(e/D$_h$) of 0.067, and a length-to-hydraulic diameter(L/D$_h$) of 30, are considered. The square ribs are arranged to follow the trace of the twisted tape and along the flow direction defined as axial interrupted ribs. The twisted tape has 0.1 mm thick carbon steel sheet with diameter of 2.8 cm, length of 90 cm, and 2.5 turns. Each wall is composed of isolated aluminum sections, and two cases of surface heating are set. The results show that uneven surface heating enhances the heat transfer coefficient over uniform heating conditions, and square ducts with twisted tape inserts plus interrupted ribs produces the best overall transfer performance.

  • PDF

3D Numerical Investigation on Reservoir System for an Overtopping Wave Energy Convertor

  • Jin, Jiyuan;Liu, Zhen;Hong, Key-Yong;Hyun, Beom-Soo
    • 한국항해항만학회지
    • /
    • 제36권2호
    • /
    • pp.97-103
    • /
    • 2012
  • Overtopping Wave Energy Convertor (OWEC) is an offshore wave energy convertor, which comprises the circular ramp and reservoir. It collects the overtopped waves and converting water pressure head into electric power through the hydro-turbines installed in the vertical duct, which is fixed in the sea bed. The performance of OWEC can be represented by the operating water heads of the device, which depends on the amount of the wave water overtopping into the reservoir. In the present paper, the reservoir with the duct connecting to the sea water are studied in the 3D numerical wave tank, which has been developed based on the computational fluid dynamics software Fluent 6.3. Both the overtopping motion and the discharges of the reservoir are investigated together, and several shape parameters and incident wave conditions are varied to demonstrate their effects on the performance of OWEC.

The Qualitative Analysis of Single Shot Fast Spin Echo (SSFSE) and Maximum Intensity Projection (MIP) on Magnetic Resonance Cholangiopancreatography

  • Park, Cheol-Soo;Cho, Jae-Hwan;Lee, Hae-Kag;Dong, Kyung-Rae;Chung, Woon-Kwan;Seok, Jong-Min;Han, Man-Seok;Lee, Sun-Yeob;Goo, Eun-Hoe;Kim, Eng-Chan
    • Journal of Magnetics
    • /
    • 제17권2호
    • /
    • pp.138-144
    • /
    • 2012
  • 3-dimensional magnetic resonance cholangiopancreatography (MRCP) images reconstructed using the maximum intensity projection technique were analyzed qualitatively in patients diagnosed with pancreatobiliary diseases to determine their diagnostic utility. Single shot fast spin echo (SSFSE), fast spin echo (FSE) and 3-dimensional reconstructive images were acquired from 20 patients diagnosed histologically with pancreatobiliary diseases using a 3.0T MR scanner. According to qualitative analysis, the fast spin echo images and 3-dimensional reconstructed images of the hepatic duct, gall bladder and common bile duct had a higher signal to noise ratio (SNR) than the single shot fast spin echo images. Fast spin echo images and 3-dimensional reconstructed images did not show any differences. The contrast to noise ratio of the hepatic duct, gallbladder and common bile duct on the fast spin echo images and 3-dimensional reconstructed images was higher than that of the single shot fast spin echo images. The fast spin echo images and 3-dimensional reconstructed images showed similar quality.

곡관 연결 조건에 따른 디젤엔진 매연여과장치 입구 유속 분포의 CFD 해석 (A CFD Analysis of Flow Velocity at Inlet of a Diesel Particulate Filter according to the Curved Duct Connection Conditions)

  • 이수룡;고영남;이충훈
    • 한국철도학회논문집
    • /
    • 제12권4호
    • /
    • pp.457-464
    • /
    • 2009
  • 디젤 엔진 매연 필터의 입구부와 배출 가스 배출을 위한 배기관 연결을 직선 또는 곡선으로 형태로 연결하였을 때의 DPF 입구 유속 분포를 $STAR-CD^{(R)}$ 전산해석 프로그램을 사용하여 시뮬레이션하였다. 곡관의 형상을 나타내는 3 종류의 수치해석 용 격자 모델을 사용하여 DPF 입구에서의 유속 분포를 시뮬레이션 하였다. 피토관을 2차원 이송장치에 탑재하고 위치를 이동시키며 측정한 유속 분포와 동일한 조건에서 시뮬레이션한 결과와 비교하였다. DPF 입구와 $90^{\circ}$의 곡관이 연결된 조건에서 CFD 해석을 수행한 결과 입구 단면에서의 유속 분포가 말발굽 형태를 나타내었으며 최대 유속값이 DPF 중심축에서 약간 벗어난 위치에서 나타나고 있다. 이러한 CFD 해석결과는 실험 결과와 비교적 잘 일치하였다.

PIV 기법을 이용한 모형철도터널 직관덕트에서 유동 분포 계측 및 수치해석 결과와의 비교분석 (MEASUREMENT OF FLOW DISTRIBUTION IN A STRAIGHT DUCT OF RAILWAY TUNNEL MOCK-UP USING PIV AND COMPARISON WITH NUMERICAL SIMULATION)

  • 장용준;정우성;박일순
    • 한국전산유체공학회지
    • /
    • 제15권3호
    • /
    • pp.39-45
    • /
    • 2010
  • The turbulent flows in a tunnel mock-up($10L{\times}0.5W{\times}0.25H$ m3 : scale reduction 1/20) with rectangular cross section were investigated. The instantaneous velocity fields of Re = 49,029, 89,571 were measured by the 2-D PIV system which is consisted of double pulsed Nd:Yag laser and the tracer particles in the straight-duct mock-up where the flows were fully developed. The mean velocity profiles were taken from the ensemble averages of 1,000 instantaneous velocity fields. Simultaneously, numerical simulations(RANS) were performed to compare with experimental data using STREAM code. Non-linear eddy viscosity model (NLEVM : Abe-Jang-Leschziner Eddy Viscosity Model) was employed to resolve the turbulent flows in the duct. The calculated mean velocity profiles were well compared with PIV results. In the log-law profiles, the experimental data were in good agreement with numerical simulations all the way to the wake region except the viscous sub-layer (near wall region).

PIV 계측을 이용한 가정용 냉장고의 냉기 유동특성 파악과 고효율 냉기 유로 설계 (PIV Analysis of the Flow Inside a Home Refrigerator and the Design of a Higher Efficiency Cooling Duct)

  • 최제호;조성호;남영석;이인섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.405-409
    • /
    • 2001
  • An experimental analysis of the flow inside the refrigeration compartment of a home refrigerator was conducted in order to achieve better performances in terms of uniform temperature distribution and cooling speed. 2D PIV and stereoscopic PIV were used for the experiments on an actual-size refrigerator at operating conditions. Two CCD cameras were employed for a wider field of view in the measurement of the shelf, and stereoscopic PIV was used to measure the three velocity components at the various cooling duct outlets and the mean velocity fields were area-integrated to calculate the flow-rates. 50 to 100 instantaneous velocity fields were time averaged for the mean velocity fields. With the result of this analysis, a new cooling duct system was developed, with the refrigerator's cooling performance increasing 11% in terms of cooling speed, and 25% in temperature uniformity.

  • PDF

고분보존용 덕트형 공조시스템의 운전 특성 (Performance of an Duct-type HVAC System for Conservation of Ancient Tombs)

  • 전용두;이금배;박진양;고석보;전희호;윤영묵
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.29-34
    • /
    • 2006
  • Although the importance of good conservation of historic sites including ancient royal tombs is well aware, still not much attention has been paid for the facilities and systems to preserve those historic sites, which includes precious artifacts as wall paints and carved works, etc. Even the level of general understanding about the environment of the underground space of tombs is not satisfactory. In Korea, researchers have recently begun addressing the importance of maintaining proper environment for underground space as of ancient tombs and are making efforts to develop suitable HVAC(heating, ventilating and air-conditioning) systems for them. In this study, an HVAC system for a tomb ($D{\times}W{\times}H=1.3m{\times}3.0m{\times}1.2m$) was installed to maintain suitable indoor conditions for conservation of tomb. The temperature and humidity inside the tomb were measured to represent the performance of the installed duct-type HVAC system. Vibration levels due to the installed an HVAC system are alive investigated experimentally. According to the measured data, the level of vibration inside the present model tomb with the duct-type unit showed significantly lower values than the case with the indoor unit inside.

  • PDF