• Title/Summary/Keyword: 2-D analysis

Search Result 15,568, Processing Time 0.06 seconds

Applying QFD in the Development of Sensible Brassiere for Middle Aged Women (QFD(품질 기능 전개도)를 이용한 중년 여성의 감성 Brassiere 개발)

  • Kim Jeong-hwa;Hong Kyung-hi;Scheurell Diane M.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.12 s.138
    • /
    • pp.1596-1604
    • /
    • 2004
  • Quality Function Deployment(QFD) is a product development tool which ensures that the voice of the customer needs is heard and translated into products. To develop a sensible brassiere for middle-aged women QFD was adopted. In this study the applicability and usefulness of QFD was examined through the engineering design process for a sensible brassiere for middle-aged women. The customer needs for the wear comfort of brassiere was made by one-on-one survey of 100 women who aged 30-40. The customer competitive assessment was generated by wearing tests of 10 commercial brassieres. The subjective assessment was conducted in the enviornmental chamber that was controlled at $28{\pm}1^{\circ}C,\;65{\pm}3\%RH.$ As a results, we developed twenty-one customer needs and corresponding HOWs for the wear comfort of brassiere. The Customer Competitive Assessment was generated by wearing tests of commercial brassiere. The subjective measurement scale and dimension for the evaluation of sensible brassiere were extracted from factor analysis. Four factors were fitting, aesthetic property, pressure sensation, displacement of brassiere due to movement. The most critical design parameter was wire-related property and second one was stretchability of main material of brassiere. Also, wearing comfort of brassiere was affected by the interaction of initial stretchability of wing and support of strap. Engineering design process, QFD was applicable to the development of technical and aesthetic brassieres.

Resilience and Characteristics of Sleep and Defense among Shift Work Nurses (교대근무자의 회복력과 수면 및 방어 특성)

  • Lee, So-Jin;Park, Chul-Soo;Kim, Bong-Jo;Lee, Cheol-Soon;Cha, Boseok;Lee, Dongyun;Seo, Ji-Yeong
    • Sleep Medicine and Psychophysiology
    • /
    • v.21 no.2
    • /
    • pp.74-79
    • /
    • 2014
  • Objectives: Shift work is a stressful situation. It is important to know the factors associated with the ability to adapt to a shift work schedule. The aim of the present study was to investigate the association between sleep, as well as personality variables, and the resilience of shift work nurses. Method: Self-report questionnaires were administered to 95 nurses who worked in one national university hospital. Connor-Davidson resilience scale, hospital anxiety and depression scale, morningness-eveningness scale, Pittsburgh sleep quality index, other sleep-related questionnaires, and Korean defense style questionnaires were used. Results: Age, shift work duration, off-day oversleep, depression, anxiety, adaptive defense style, and self-suppressive defense style were significantly associated with resilience (p < 0.05). Multiple regression analysis showed that age (${\beta}=0.34$, p < 0.05), depression (${\beta}=-0.25$, p < 0.05), adaptive defense style (${\beta}=0.45$, p < 0.001), and self-suppressive defense style (${\beta}=-0.19$, p < 0.05) significantly predicted the resilience of shift work nurses. Concerning individual defense mechanisms, resignation (${\beta}=-0.20$, p < 0.05), sublimation (${\beta}=0.19$, p < 0.05), omnipotence (${\beta}=0.19$, p < 0.05), and humor (${\beta}=0.20$, p < 0.05) significantly predicted the resiliency. Conclusion: The findings indicate that a specific defense style and other mechanisms were associated with the resilience of shift work nurses. A future prospective study with more participants could further clarify the relationship between sleep-related variables, as well as personality factors, and resilience of shift work nurses.

A Comparative Analysis between Photogrammetric and Auto Tracking Total Station Techniques for Determining UAV Positions (무인항공기의 위치 결정을 위한 사진 측량 기법과 오토 트래킹 토탈스테이션 기법의 비교 분석)

  • Kim, Won Jin;Kim, Chang Jae;Cho, Yeon Ju;Kim, Ji Sun;Kim, Hee Jeong;Lee, Dong Hoon;Lee, On Yu;Meng, Ju Pil
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.35 no.6
    • /
    • pp.553-562
    • /
    • 2017
  • GPS (Global Positioning System) receiver among various sensors mounted on UAV (Unmanned Aerial Vehicle) helps to perform various functions such as hovering flight and waypoint flight based on GPS signals. GPS receiver can be used in an environment where GPS signals are smoothly received. However, recently, the use of UAV has been diversifying into various fields such as facility monitoring, delivery service and leisure as UAV's application field has been expended. For this reason, GPS signals may be interrupted by UAV's flight in a shadow area where the GPS signal is limited. Multipath can also include various noises in the signal, while flying in dense areas such as high-rise buildings. In this study, we used analytical photogrammetry and auto tracking total station technique for 3D positioning of UAV. The analytical photogrammetry is based on the bundle adjustment using the collinearity equations, which is the geometric principle of the center projection. The auto tracking total station technique is based on the principle of tracking the 360 degree prism target in units of seconds or less. In both techniques, the target used for positioning the UAV is mounted on top of the UAV and there is a geometric separation in the x, y and z directions between the targets. Data were acquired at different speeds of 0.86m/s, 1.5m/s and 2.4m/s to verify the flight speed of the UAV. Accuracy was evaluated by geometric separation of the target. As a result, there was an error from 1mm to 12.9cm in the x and y directions of the UAV flight. In the z direction with relatively small movement, approximately 7cm error occurred regardless of the flight speed.

평행식 진동탄환 암거 천공기의 연구 (IV)(V)-실기 설계 제작 및 보장실험-Development of Balanced-Type Oscillating Mole Drainer(IV)(V)

  • 김용환;이승규;서상용
    • Journal of Biosystems Engineering
    • /
    • v.2 no.1
    • /
    • pp.7-24
    • /
    • 1977
  • This paper is the forth and fifth one of the study on balanced type oscillating mole drainer. In the light of the results from previous reports about the model tests, some design criteria were established and a prototype machine was set up for experimental purpose. Motion characteristics and functionof the each parts of the machine were checked and analyzed. After that, performance tests of the prototype machine were carried out in thefield. Obtained results are summarized as follows ; 1. Ten centimeter of the bullet diameter was determined so as to be able to attach it to the tractors with capacity of 30 PS to 40 PS. 2. To maintain the balance between the moments of the front shank and rear shank, the oscillating amplitude of the rear bullet was determined to be larger than that of the front bullet. At the same time , the oscillating direction of the rear bullet was designed with the inclines of ten to thirty degrees. 3. An octagonal dynamo transduced was developed for measuring the compressive force of the upper link is measuring the draft force of the machine. Acceptable linear relationship between forces and strain responses from O.D.T. was obtained. 4. Analysing the balancing mechanism of the acting part of the machine , it was found that the total draft force of the machine was equal to the difference between the sum of the draft force produced from the right and left side bending moments of the lower drawber and the compressive force on the upper link. 5. There are acceptable linear relationship between the strain and twisting moment by driving shaft, and between strain and shank moment. Above results enable us to carry out the field experiment with prototype machine. 6. When the test machine was used in the field, it was possible to reduce the oscillating acceleration by forty percent in average as compared it with the single bullet mole drainer. 7. When the test machine was used under the oscillating condition, the dratt torce was reduced by 27 percent to 59 percent as compared it with the test machine under non-oscillating condition, while the draft force was increased by 7 percent to 20 percent as compared it with the mole drainer having oscillating single bullet. The reasoning behind this fact was considered as the resistance force due to the rear shank and bullet. 8. As the amplitude and frequency of the bullet were increased, the torque was increased accordingly. This tendency could be varied with the various characteristics of the given soils. And the larger frequency and amplitute, the more increasing oscil\ulcornerlating power but decreasing draft brce were needed, and draft force was increased as the velocity was increased.9. When the amplitude of the rear bullet was designed to be larger than that of the front bullet, the minimum value of the moment was lowered and oscillating acceleration was reduced. And when the oscillating direction of the rear bullet was declined back\ulcornerwards, oscillating acceleration was increased along with the increasing angle of decli\ulcornernation. When the test machine was operated in high speed, the difference between maximum moments and minimum ones became narrow. This varying magnitude of moments appeared on the moment oscillogram seems to be correlated to the oscillating acceleration and draft force. 10. From the analysis of variance, it was found that those factors such as frequency, amplitude, and operating velocity significantly affected in the oscillating acceleration, the draft resistance, the torque, the moment, and the total power required. And interaction between frequency and amplitude affected in the oscillating acceleration. 11. Within the given situation of this study, the most preferable operating conditions of the test machine were 7 Hz in oscillating frequency, 0.54 m/sec in operating velocity, and 39.1 mm in oscillating amplitude of front and rear bullets. However, it is necessary to select the proper frequency and magnitude of oscillation depending on the soil properties of the field in which the mole drainer is practiced by use of a bal1nced type oscillating mole drainer. 12. It is recommended that a comparative study of the mole drainers would be performed in the near future using two separate balanced oscillating bullet with the one which is operated by oscillating the movable bullet in a single cylinder or other balanced type which may be single oscillating bullet with spring, damper or balancing weight, and that of thing. To expand the applicability of the balanced type oscillating mole drainer in practical use, it is suggested to develop a new mechanism which perform mole drain with vinyl pipe or filling material such as rice hull.

  • PDF

Improvement of Total Chrolophill Analytical Methods for the Chlorella Products with Extended Products Types (신 제형 클로렐라제품의 총 엽록소 시혐법 개선)

  • Kim, Yoo-Kyung;Lee, Eun-Suk;Han, Jae-Gab;No, Gi-Me;Lim, Dong-Gil;Jung, Ja-Young;Park, Young-Sig
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.1
    • /
    • pp.70-75
    • /
    • 2011
  • A new and improved analytical method involving alkaline pyridine extraction was proposed to quantity chlorophyll contents in syrup and candy type chlorella products. The performance of analytical method was compared with the conventional Korea food standard method which involves acetone extraction. The application of sonication chlorophyll extraction form alkaline pyridine sample was also explored. The analytical procedure was validated by evaluating accuracy, precision and reproducibility. For liquid samples, the pyridine extraction method showed higher accuracy and precision compared to acetone extraction method. The CV values of pyridine extract method and the acetone extraction method were 18.82 and 40.0, and the accuracy to theoretical values were 106.3% and 78.1%, respectively. When sonication extraction method was applied to the pyridine extraction, the precision was improved as indicated by reduced CV values from 18.82 to 11.36. The improved performance of pyridine-sonication extraction was also validated by recovery test of chlorophyll that was previously spiked into the sample matrix. For solid matrix, the pyridine extraction method showed better performance in analysis of chlorophyll in solid food matrix (CV = 7.05) compared to conventional acetone extraction method (CV = 30.0). However, the accuracy to theoretical values of pyridine and acetone extraction methods only showed only 62.7% an 40%, respectively. The relatively low accuracy of pyridine extraction method (62.7%) was improved to 99.4% by applying additional sonication extraction method. The improved performance of applying additional sonication extraction was validated by standard deviation, CV values and accuracy to theoretical values.

Viability Assessment of Fresh and Frozen-thawed Dog Spermatozoa by Flow Cytometry (Flow Cytometry에 의한 개 신선정액과 동결정액의 생존성 분석)

  • Hong Y. M.;Kim Y. J.;Yu I.;Ji D. B.;Kim M. S.
    • Reproductive and Developmental Biology
    • /
    • v.28 no.3
    • /
    • pp.167-172
    • /
    • 2004
  • This study was performed to examine the correlations among dog sperm viabilities evaluated by flow cytometry, by microscopic evaluation (ME), by carbo-xifluorescein diacetate and propidium iodide (CFDA/PI) and by hypoosmotic swelling (HOS) test. Semen were collected from 5 dogs ranging in age from 2 to 4 years. Each ejaculate was divided into 3 aliquots and different proportions of freeze-killed cells were added to each aliquot (1:0, 1:1 and 1:3). In the other experiment, semen was extended with Sweden extender containing 5% glycerol and equex STM paste, and frozen using liquid nitrogen vapor. Fresh and frozen-thawed dog sperm viability were assessed by flow cytometry using PI staining method. The accuracy of flow cytometry was evaluated by comparing with other classic assessments, microscopic evaluation, epifluorescence microscopic analysis using CFDA/PI, and HOS test. High correlations of sperm viabilities were found among flow cytometry, epifluorescence evaluation, HOS test (p<0.01) in fresh semen. Especially, sperm viability assessed by HOS test was highly correlated with viability by flow cytometry in all the ratios of live and dead spermatozoa, 1:0, 1:1 and 1:3 (p<0.01). The viability evaluated by ME were significantly correlated with that by flow cytometry in ratios of 1:0 and 1:3 (p<0.05) however, there was no significance in ratio of 1:1. The viability evaluated by C/p were highly correlated with that by flow cytometry in ratio of 1:0 and 1:1 (p<0.01) and significantly correlated in ratio of 1:3 (p<0.05). In frozen-thawed spermatozoa, the viability determined by HOS test was considerably correlated with that by flow cytometry (p<0.01). There was significant correlation between the viabilities by ME and by flow cytometry (p<0.05). But the viability evaluated by CFDA/PI was not correlated with viability by flow cytometry. The result from this study validate the use of flow cytometry as a precise method for assessing the viability of fresh and frozen-thawed dog spermatozoa.

Summer Hydrographic Features of the East Sea Analyzed by the Optimum Multiparameter Method (OMP 방법으로 분석한 하계 동해의 수계 특성)

  • Kim, Il-Nam;Lee, Tong-Sup
    • Ocean and Polar Research
    • /
    • v.26 no.4
    • /
    • pp.581-594
    • /
    • 2004
  • CREAHS II carried out an intensive hydrographic survey covering almost entire East Sea in 1999. Hydrographic data from total 203 stations were released to public on the internee. This paper summarized the results of water mass analysis by OHP (Optimum Multiparameter) method that utilizes temperature, salinity, dissolved oxygen, pH, alkalinity, silicate, nitrate, phosphate and location data as an input data-matrix. A total of eight source water types are identified in the East Sea: four in surface waters(North Korea Surface Water, Tatar Surface Cold Water, East Korean Coastal Water, Modified Tsushima Surface Water), two intermediate water types (Tsushima Middle Water, Liman Cold Water), two deep water types (East Sea Intermediate Water, East Sea Proper Water). Of these NKSW, MTSW and TSCW are the newly reported as the source water type. Distribution of each water types reveals several few interesting hydrographic features. A few noteworthy are summarized as follows: The Tsushima Warm Current enter the East Sea as three branches; East Korea Coastal Water propagates north along the coast around $38^{\circ}N$ then turns to northeastward to $42^{\circ}N$ and moves eastward. Cold waters of northern origin move southward along the coast at the subsurface, which existence the existence of a circulation cell at the intermediate depth of the East Sea. The estimated volume of each water types inferred from the OMP results show that the deep waters (ESIW + ESPW) fill up ca. 90% of the East Sea basins. Consequently the formation and circulation of deep waters are the key factors controlling environmental condition of the East Sea.

Polymorphisms of the Exons 13, 15 and 16 of Transferrin Gene in Cheju Horses (제주마 Transferrin Gene Exon 13, 15 및 16의 다형현상)

  • Kim, N.Y.;Lee, S.S.;Yang, Y.H.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.4
    • /
    • pp.391-398
    • /
    • 2002
  • This study was conducted to determine the polymorphism of transferrin exons 13, 15 and 16 by Single-Strand Conformation Polymorphism(SSCP) analysis and to compare their genotypes of Cheju horse Group I (Cheju Institute), Cheju horse Group II (farms), and Thoroughbred (KRA). SSCP of transferrin exon 13, 15, and 16 showed two (A, B), three (A, B, C) and three (A, B, C) codominant alleles, respectively. The Group I and Thoroughbred showed the similar frequencies of allele A and B in transferrin exon 13, but only allele A was observed in Group Ⅱ. In transferrin exons 15 and 16, the frequencies of each allele were different in each Groups. The multiple allele frequencies in exons 15 and 16 suggested that the genotyping of this locus could be used to identify an individual and to test the parentage of offspring. The probability for parentage exclusion were 0.46 and 0.374 for exons 15 and 16 for Cheju horse Group I. Among the 13 combined genotypes of exons 13, 15 and 16, the genotype AA-AB-AB (0.372) is the most common in Cheju horse Group I, but genotype AA-AA-AA is common in the Cheju horse Group II (0.366) and Thoroughbred (0.767). The present study showed two new SNP, which was at the cDNA position 1626 (A/G) in B allele of the exon 13 and 2075 (C/T) in C allele of the exon 16 resulting in amino acid change (Threonine $\longrightarrow$ Methionine). Result showed that polymorphism of exons 13, 15 and 16 in Cheju horses was as high as in Thoroughbred and there was a differences of transferrin allele frequencies in Cheju horses.

Mechanism and Spray Characteristics of a Mini-Sprinkler with Downward Spray for Prevention of Drop Water (하향 분사식 미니스프링클러의 낙수방지 메카니즘과 살수 특성)

  • Kim, Hong-Gyoo;Chung, Sung-Won
    • Journal of Bio-Environment Control
    • /
    • v.16 no.3
    • /
    • pp.210-216
    • /
    • 2007
  • A study was conducted to find mechanism and spray characteristics of a mini-sprinkler with downward spray to develop a new design type to be able to prevent drop water. The experiments were executed in a plastic greenhouse to minimize the effect of the wind. Data was collected at five different operation pressures and at 4 different raiser heights. Spray characteristics of the sprinkler such as effective radius, effective area, mean application depth, absolute maximum application depth, effective maximum application depth and coefficient of variation were determined. In order to analyze the mechanism and packing supporter of sprinkler, the numerical simulation using ABAQUS was performed. The optimum pressure for preventing drop water was determined.

Makeup Cleansing Formulation with Lamellar Liquid Crystal Phase (라멜라 액정상 메이크업 클렌징 제형)

  • Yeo, Hye Lim;Lee, Ji Hyun;Kim, Su Ji;Noh, Minjoo;Jang, Ji Hui;Kim, Youn Joon;Yoon, Moung Seok;Yoo, Kweon Jong;Lee, Jun Bae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.43 no.1
    • /
    • pp.79-86
    • /
    • 2017
  • This study is related to a lamellar liquid crystal make-up cleansing formulation with a hologram-like unique appearance between two polarizing plates. Make-up cleansing formulations with a lamellar liquid crystal phase have been extensively studied for a long time, but there have been limitations in practical commercialization because of increasing turbidity and viscosity. In this study, to solve this problem, alkyl chains of surfactants were modified to increase the fluidity of the liquid crystal phase, and electrostatic repulsion force was increased by introducing anionic surfactant. The lamellar liquid crystal make-up cleansing formulation which introduced anionic surfactants can easily inhibit crystallization through electrostatic repulsion force, thereby showing excellent stability overtime, maintaining transparent appearance and viscosity. In addition, we have newly introduced an in vitro cleansing evaluation method using fluorescent material and in vivo imaging system (IVIS) for objective and quantitative cleansing ability evaluation. The excellent cleansing ability of lamellar liquid crystal cleansing formulation has been confirmed by newly developed evaluation method. On the other hand, when lamellar liquid crystal make-up cleansing formulation was placed between orthogonally arranged two polarizing plates, a specific pattern like a hologram can be observed. This phenomenon is presumably interpreted as the interference between the visible light passing through the liquid crystal formulation and the lamellar structure. The lamellar structure of cleansing formulation was confirmed by SAXS analysis, exhibiting Bragg spacing ratio of 1 : 2. The lamellar liquid crystal make-up cleansing formulation prepared in this study would be useful for future application in make-up cleansing due to its excellent stability, cleansing ability, and unique hologram-like pattern placed between two polarizing plates.