• Title/Summary/Keyword: 2-온도 모델

Search Result 1,548, Processing Time 0.034 seconds

Absorption Characteristics of Green Tea Powder as Influenced by Particle Size (입자크기에 따른 분말 녹차의 흡습특성)

  • Youn, Kwang-Sup
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.10
    • /
    • pp.1720-1725
    • /
    • 2004
  • Absorption characteristics of green tea powder were investigated. The monolayer moisture content determined by GAB equation was 0.024~0.052 g $H_2O$/g dry solid. The absorption enthalpy was calculated with different particle size and various water activities. It showed that the absorption energy was decreased with increasing water activity but no difference was found on particle size increasement. Among models applied for predicting equilibrium moisture content, Halsey model was the best fit model for green tea powders, showing the lowest prediction deviation of 2.1~4.0%. The prediction model equations for the water activity was established as function of relative humidity, time and temperature. The model equation will be helpful for future work on drying and storage of green tea powder.

Physical Properties of Acetylated Sweet Potato Starches as Affected by Degree of Substitution (치환도가 초산 고구마전분의 물리적 특성에 미치는 영향)

  • Yoo, Byoung-Seung;Lee, Hye-Lin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.7
    • /
    • pp.1048-1052
    • /
    • 2011
  • This study examined the flow properties, paste clarity, freeze-thaw stability and gel strength of acetylated sweet potato starch (ASPS) pastes and gels as a function of degree of substitution (DS). ASPS showed high shear-thinning flow behaviors with high Casson yield stress ($\sigma_{oc}$). Consistency index (K), apparent viscosity ($\eta_{a,100}$) and $\sigma_{oc}$ values of ASPS increased with an increase in DS. In the temperature range of $25{\sim}70^{\circ}C$, ASPS followed an Arrhenius temperature relationship. The activation energies (Ea=13.2~14.3 kJ/mol) of the ASPS samples were much lower than that (18.1 kJ/mol) of the native sweet potato starch (SPS). ASPS gels showed better freeze-thaw stability with a significant decrease in syneresis (%) compared to SPS gel. The gel strength values of ASPS were much lower than that of SPS, and significantly decreased with an increase in DS. The clarity of native SPS paste increased after acetylation.

Plant Performance Analysis for IGCC Employing HGCU(I) (고온정제를 적용한 IGCC 플랜트 성능 해석에 관한 연구(I))

  • 이윤경;서석빈;김종진
    • Journal of Energy Engineering
    • /
    • v.9 no.3
    • /
    • pp.157-162
    • /
    • 2000
  • 기존의 IGCC의 장점인 고효율 플랜트의 특성을 살리기 위해 고온정제를 적용하는 경우 조건변화에 따른 플랜트 성능의 영향을 관찰하고자 본 연구를 수행하였다. IGCC에 고온정제 공정을 적용하여 구성한 모델은 연구 목적에 알맞은 범위의 건전성을 가진 것으로 나타났으며 기타 조건을 동일하게 설정한 경우 저온 정제 공정(MDEA amine) 적용에 비해 플랜트 효율이 약 2.7% 가량 상승하였다. 한편 동일한 고온정제 공정이라도 적용하는 흡수제를 zinc titanate에서 zinc ferrite로 달리 하는 경우 탈황제의 화학 반응상 특성 및 차이점으로 인해 연료가스의 발열량 변화를 유발하므로 결과적으로 약 0.5%의 플랜트 효율 손실이 발생함을 알 수 있었다. 또한 탈황 온도 350~$650^{\circ}C$ 사이의 온도범위에 대해 민감도 분석을 실행하였으며 민감도 분석 결과 전제 온도의 증가와 플랜트 효율은 정비례하지 않으며 50$0^{\circ}C$ 이상의 정제 온도를 적용한 경우는 거의 비슷한 효율을 나타내었다. 이와 같은 결과는 정제 온도를 증가시킴으로 인해 가스터빈에 공급되는 연료가스의 온도는 높아지지만 적용한 가스터빈의 출력 및 연소 온도가 제한되어 있어 고온정제를 적용함으로써 얻어지는 이득을 가스터빈에서 충분히 보상하지 못하고 한편으로 고온정제를 채택함으로써 저온정제 적용시 보다 syngas cooler에서 회수할 수 있는 헌열이 줄어듦으로 인한 증기 터빈 출력의 감소가 커지기 때문으로 분석되었다.

  • PDF

Thermal Model Correlation and Heater Design Verification for LEO Satellite Optical Payload's Thermal Analysis Model Verification (저궤도 위성 광학탑재체의 열해석 모델 검증을 위한 열모델 보정 및 히터 설계)

  • Kim, Min-Jae;Huh, Hwan-Il;Kim, Sang-Ho;Chang, Su-Young;Lee, Deog-Gyu;Lee, Seung-Hoon;Choi, Hae-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.11
    • /
    • pp.1069-1076
    • /
    • 2011
  • All of the satellite components must be operated within the permissible temperature range during the mission in orbit. Therefore, thermal design is performed to develop verified thermal model and to secure thermal stability on the ground. In this study, thermal model correlation was performed to satisfy the criteria of correlation using ground thermal vacuum/thermal balance test results of LEO satellite optical payload. We also secured verified thermal model by controlling operating cycle of flight heaters. In addition, it was confirmed that all components are within the permissible temperature range through conducting orbit environment thermal analysis. We also secured thermal stability of the satellite.

Prediction of Seedling Emergence and Early Growth of Eleocharis kuroguwai Ohwi under Evaluated Temperature (상승된 온도 조건에서 올방개(Eleocharis kuroguwai)의 출아 및 초기생장 예측)

  • Kim, Jin-Won;Moon, Byeong-Chul;Lim, Soo-Hyun;Chung, Ji-Hoon;Kim, Do-Soon
    • Korean Journal of Weed Science
    • /
    • v.30 no.2
    • /
    • pp.94-102
    • /
    • 2010
  • Field and pot experiments were conducted to investigate seedling emergence and early growth of Eleocharis kuroguwai panted on different dates. Non-linear regression analyses of observed data against effective accumulated temperature (EAT) with the Gompertz model showed that the Gompertz model works well in describing seedling emergence and early growth of E. kuroguwai regardless of planting date and soil burial depth. EATs required for 50% of the maximum seedling emergence of E. kuroguwai planted at 1, 3 and 5 cm soil burial depth in the pot experiment were estimated to be 54.5, 84.0 and $118.0^{\circ}C$, respectively, and $56.7^{\circ}C$ when planted at 1 cm in the field experiment. EATs required for 50% of the maximum leaf number of E. kuroguwai planted at 1, 3 and 5 cm soil burial depth in the pot experiment were estimated to be 213.3, 249.0 and $291.6^{\circ}C$, respectively, and $239.5^{\circ}C$ when planted at 1 cm in the field experiment. Therefore, models developed in this study thus predicted that if rotary tillage with water is made on 27 May under $+2^{\circ}C$ elevated temperature condition, dates for 50% of the maximum seedling emergence, 5 leaf stage and 5 cm plant height of E. kuroguwai buried at 3 cm soil depth were predicted to be 2 June, 10 June and 12 June. These dates are 1 day earlier for the seedling emergence and 3 days earlier for the early growth as compared with current temperature condition, suggesting that earlier application of herbicides is required for effective control of E. kuroguwai.

Shape optimal design of a 2-D heat transfer system with the isoparametric finite element (等係數 유한요소를 사용한 2차원 열전달시스템의 형상 최적설계)

  • 유영면;박찬우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.1
    • /
    • pp.82-87
    • /
    • 1987
  • In this study a method of shape optimization is applied to two dimensional heat transfer system. For this the optimization problem is defined in a functional form including cost, constraints and the system governing equation. Then the material derivative concept in continuum mechanics and the adjoint variable method are employed for the shape design sensitivity analysis. With the sensitivity analysis results, an optimum is sought with the gradient projection optimization algorithm. The two dimensional isoparametric finite elements are used for accurate analysis and sensitivity calculations. The above method is employed to find the boundary shape to achieve a desired temperature distribution along a segment of the boundary subject to the maximum area constraint.

Analysis of electrical characteristics for p-type silicon germanium metal-oxide semiconductor field-effect transistors (SiGe pMOSFET의 전기적 특성 분석)

  • Ko Suk-woong;Jung Hak-kee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.2
    • /
    • pp.303-307
    • /
    • 2006
  • In this paper, we have designed the p-type metal-oxide semiconductor field-effect transistor(pMOSFET) for SiGe devices with gate lengths of $0.9{\mu}m$ and $0.1{\mu}m$using the TCAD simulators. The electrical characteristics of devices have been investigated over the temperatures of 300 and 77K. We have used the two carrier transfer models(hydrodynamic model and drift-diffusion model). We how that the drain current is higher in the hydrodynamic model than the drift-diffusion model. When the gate length is $0.9{\mu}m$, the threshold voltage shows -0.97V and -1.15V for 300K and 77K, respectively. The threshold voltage is, however, nearly same at $0.1{\mu}m$ for 300K and 77K.

Development of Asphalt Concrete Rutting Model by Triaxial Compression Test (삼축압축시험을 이용한 아스팔트 혼합물의 소성변형 파손모형 개발)

  • Lee, Kwan-Ho;Hyun, Seong-Cheol
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.1
    • /
    • pp.57-64
    • /
    • 2009
  • This study intends to evaluate of the characteristics of pavement deformation and develop the model for prediction model in the asphalt layer using a regression analysis. In test, there are two different asphalt binders and 5 different aggregate types. The air voids of hot mix asphalt are 6% and 10% for target value. Repeated triaxial compression test with 3 different confining pressures was used for test at 3 different test temperatures. It is going to verify the main parameters for permanent deformation of HMA and to develop the distress model. This paper is to figure out the factor affecting the pavement deformation, and then to develop model the pavement deformation for asphalt mixture. Also, the reliability of prediction model has been studied. The permanent deformation prediction model for asphalt mixtures with temperature, loading time, and air voids has been developed and the proposed permanent deformation prediction model has been validated by using the multiple regression approach which is called Statistical Package for the Social Sciences(SPSS).

Flow Characteristics of R600a in an Adiabatic Capillary Tube (단열 모세관내 R600a의 유동 특성)

  • Ku, Hak-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.449-454
    • /
    • 2010
  • In this paper, flow characteristics of R600a in an adiabatic capillary tube were investigated employing the homogeneous flow model. The model is based on fundamental equations of mass, energy and momentum which are solved simultaneously. Two friction factors(Churchill) and viscosity(McAdams) are comparatively used to investigate the flow characteristics. Thermodynamic and transport properties of R600a are calculated employing EES property code. Flow characteristics analysis of R600a in an adiabatic capillary tube is presented to offer the basic design data for the operating parameters. The operating parameters considered in this study include condensation temperature, evaporation temperature, subcooling degree and inner diameter tube of the adiabatic capillary tube. The main results were summarized as follows: condensation and evaporation temperature, inlet subcooling degree and inner diameter tube of an adiabatic capillary tube using R600a have an effect on length of an adiabatic capillary tube. The length of an adiabatic capillary tube using R600a is expressed to the correlation shown in Eq. (15).

Development of Predictive Growth Model of Listeria monocytogenes Using Mathematical Quantitative Assessment Model (수학적 정량평가모델을 이용한 Listeria monocytogenes의 성장 예측모델의 개발)

  • Moon, Sung-Yang;Woo, Gun-Jo;Shin, Il-Shik
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.194-198
    • /
    • 2005
  • Growth curves of Listeria monocytogenes in modified surimi-based imitation crab (MIC) broth were obtained by measuring cell concentration in MIC broth at different culture conditions [initial cell numbers, $1.0{\times}10^{2},\;1.0{\times}10^{3}\;and\;1.0{\times}10^{4}$, colony forming unit (CFU)/mL; temperature, 15, 20, 25, 37, and $40^{\circ}C$] and applied to Gompertz model to determine microbial growth indicators, maximum specific growth rate constant (k), lag time (LT), and generation time (GT). Maximum specific growth rate of L. monocytogenes increased rapidly with increasing temperature and reached maximum at $37^{\circ}C$, whereas LT and GT decreased with increasing temperature and reached minimum at $37^{\circ}C$. Initial cell number had no effect on k, LT, and GT (p > 0.05). Polynomial and square root models were developed to express combined effects of temperature and initial cell number using Gauss-Newton Algorism. Relative coefficients of experimental k and predicted k of polynomial and square root models were 0.92 and 0.95, respectively, based on response surface model. Results indicate L. monocytogenes growth was mainly affected by temperature and square root model was more effective than polynomial model for growth prediction.