• Title/Summary/Keyword: 2 order system

Search Result 14,807, Processing Time 0.049 seconds

Development of Real Time Smart Structure Monitoring System for Bridge Safety Maintenance using Sensor Network (센서 네트워크 기반 실시간 교량 안전관리를 위한 지능형 구조 건전성 모니터링시스템 개발)

  • Jo, Byung-Wan;Kim, Heon;Lee, Yun-Sung;Kim, Do-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.2
    • /
    • pp.221-230
    • /
    • 2016
  • As structures' long term performances and users' safety have been highlighted, a new maintenance technique using IT has drawn attention around the globe. Therefore, throughout the paper, by analyzing bridge's static and dynamic data using wireless measuring sensor, a "real time smart bridge monitoring system" has developed. Smart bridge monitoring system is consists of three main parts a sensor that can measure major members' movement, a wireless system that informs the data from the sensor, and the database system that analysis the data. In order to test the performance of the system, five different were placed on the Olympic Bridge, Seoul. The power system of the sensors was replaced by self-sustain solar energy system. In order to validate data from the real time smart bridge monitoring system, the data was collected for a week from both wireless system and the wired system and the two data were compared to see the relevance.

A Study on Multi-Vehicle Control of Electro Active Polymer Actuator based on Embedded System using Adaptive Fuzzy Controller (Adaptive Fuzzy 제어기를 이용한 Embedded 시스템 기반의 기능성 고분자 구동체 다중제어에 관한 연구)

  • 김태형;김훈모
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.2
    • /
    • pp.94-103
    • /
    • 2003
  • In case of environment requiring safety such as human body and requiring flexible shape, a conventional mechanical actuator system does not satisfy requirements. Therefore, in order to solve these problems. a research of various smart material such as EAP (Electro Active Polymer), EAC (Electro Active Ceramic) and SMA (Shape Memory Alloy) is in progress. Recently, the highest preferring material among various smart material is EP (Electrostictive Polymer), because it has very fast response time, powerful force and large displacement. The previous researches have been studied properties of polymer and simple control, but present researches are studied a polymer actuator. An EP (Electostrictive Polymer) actuator has properties which change variably ils shape and environmental condition. Therefore, in order to coincide with a user's purpose, it is important not only to decide a shape of actuator and mechanical design but also to investigate a efficient controller. In this paper, we constructed the control logic with an adaptive fuzzy algorithm which depends on the physical properties of EP that has a dielectric constant depending on time. It caused for a sub-actuator to operate at the same time that a sub-actuator system operation increase with a functional improvement and control efficiency improvement in each actuator, hence it becomes very important to manage it effectively and to control the sub-system which Is operated effectively. There is a limitation on the management of Main-host system which has multiple sub-system, hence it brings out the Multi-Vehicle Control process that disperse the task efficiently. Controlling the multi-dispersion system efficiently, it needs the research of Main-host system's scheduling, data interchange between sub-actuators, data interchange between Main-host system and sub-actuator system, and data communication process. Therefore in this papers, we compared the fuzzy controller with the adaptive fuzzy controller. also, we applied the scheduling method for efficient multi-control in EP Actuator and the algorithm with interchanging data, protocol design.

A Study on System Model of Clinical Specialist in Radiologic Technology (전문방사선사 제도의 개발에 관한 연구)

  • Choi, Jong-Hak;Kim, You-Hyun;Kang, Hee-Doo;Oh, Moon-Kyu;Kim, Byung-Do;Han, Seung-Hee
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.63-76
    • /
    • 2000
  • License system of radiologic technologists has been started since 1965 in Korea. This study is to explore directions on radiotechnologists' license system classified by subspecialty. For this purpose, the authors surveyed on radiotechnologists' license system classified by subspecialty, with the subject related to radiotechnologic societies. Additionally, data on qualification and license system associated with medical and health care field were collected. The results are as follows. 1. The main body for subspecialty system for radiologic technologists should be the Korea Radiologic Technologists Association and the Association should maintain a close cooperation with radiotechnologic societies. 2. A radiologic technologist should be a basic role once they pass the license examination. In addition, they can get a special qualification by subspecialty in radiologic technology. 3. Radiotechnologists' license system classified by subspecialty will be keep priorities in order and done systematically. Execution order is as follows ; This study proposes that radiotechnologists responsible for ultrasonography, computed tomography(CT), magnetic resonance imaging(MRI) and security management be started for the first stage. For the second stage, radiotechnologists for mammography, angio-cardiography, digital imaging, maxillo-facial and dental radiography, nuclear medicine, radio-therapeutic field should be in force. 4. Professional education course(basic and intensive) and clinical training program have to be made for the eligibility of radiotechnologists' license system classified by subspecialty. 5. Eligibility system of radiotechnologists' license system classified by subspecialty(non-government or government) has to be made. Further more, inquiry commission to investigate eligibility for radiotechnologists' license system should be established.

  • PDF

The Effect of the Milk Yield and Performance Analysis of Robot Milking System (로봇 착유시스템의 착유성능 및 착유량에 미치는 영향)

  • Kim, W.;Lee, D.W.
    • Journal of Animal Environmental Science
    • /
    • v.15 no.1
    • /
    • pp.29-36
    • /
    • 2009
  • The authors of this study have developed a robot milking system composed of a multi-articular manipulator, a teat-cup attachment system, and an image processing system. In order to verify the efficacy of this system, we have conducted a performance analysis and measurement experiment of milk yield, using dairy cattle. It was concluded that teat recognition using the image processing system, teat-cup attachment, and detachment system did not binder milking. The milking yield of the robot milking system was analyzed based on a lactation curve. As a result, it was determined that the use of a robot milking system had no significant effects on milking yields. The robot milking system described in this study is designed specifically with a focus on teat-cup attachment and detachment performance, as well as the effect of these factors on milking yield. In the future, in-depth studies regarding the washing of the teats prior to milking, teat massage, pre-treatment and post-treatment processes after milking, and disinfection processes shall be conducted, in order to render this system feasible for use in an actual milking parlor.

  • PDF

A Study on Job Satisfaction by Medical Information System Accomplishment

  • Kim, Chung-Gun;Sohn, Chang-yong;Chung, Yun-kyung
    • Journal of Korean Clinical Health Science
    • /
    • v.6 no.2
    • /
    • pp.1126-1135
    • /
    • 2018
  • Purpose. The purpose of this study is to investigate the success model related to the hospital information system accomplishment. It is important to examine the success model of the hospital information system and to analyze the factors affecting the job satisfaction accomplishment. Methods. The method of this study is to 150 copies of the entire survey data were distributed and 135 copies were collected, showing a collection rate of 90%. In order to ensure the reliability of the questionnaire items, Cronbach's Alpha was used to test reliability, and exploratory factor analysis was conducted to determine the convergence of various items. In order to grasp the convergence of various items, exploratory factor analysis was performed. The results of exploratory factor analysis were used to analyze the correlations between variables that were proven to have a single dimensionality before calculating factor loadings and regression analysis by Orthogonal Rotation by Varimax method Results. The results of this study, first, the system quality of the hospital information system has a statistically significant effect on user satisfaction. Second, the information quality of hospital information system is statistically significant for user satisfaction, indicating that information quality improves user satisfaction. Third, service quality of hospital information system was statistically significant in user satisfaction. Finally, the higher the satisfaction of the users who use the hospital information system, the higher the accomplishment of the organization Conclusions. This study is based on the successful model of D & M information system. In addition, the hospital information system, the user satisfaction, and the organizational accomplishment in connection with it can be found significant.

AN EXPERIMENTAL STUDY ON THE FILM THICKNESS OF RESIN LUTING CEMENTS (치과용 레진 시멘트의 피막도에 관한 실험적 연구)

  • Cho Kook-Hyeon;Song Chang-Yong;Song Kwang-Yeob;Park Chan-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.2
    • /
    • pp.212-224
    • /
    • 1994
  • The purpose of this study was to evaluate and compare film thickness of five kinds of resin luting cements [Comspan, Panavia Ex, Maryland bridge adhesive, All-bond C & B cementation kit, and Super-bond C & B]. Zinc-phosphate cement and glass-ionomer cement were used as the control group. In order to measure the film thickness the methods used were in broad compliance with ADA Specification No. 8, a tapered-die system that simulates clinical conditions more closely, and the connected tapered-die system that simulates bridge conditions. The inorganic filler size of resin cements was also examined with scanning electron micrographs. The results were obtained as follows ; 1. The film thickness of resin cements was increased in the order of Comspan, Panavia Ex, Super-bond C & B, Maryland bridge adhesive, and All-bond C & B cementation kit. Maryland bridge adhesive and All-bond C & B cementation kit showed significantly higher film thickness than the control group(p<0.01). 2. For all resin cements, there was a significant difference of film thickness between the ADA method and the tapered-die system. Generally, the tapered-die system demonstrated lower film thickness than the ADA method(p<0.01). 3. There was no significant difference in film thickness between the tapered-die system and the tapered-die bridge system in all resin cements(p<0.01). 4. The scanning electron microscope showed that the cement with larger filler had a tendency to be higher in film thickness.

  • PDF

Development of Real-time Service Primitive in Message Handling System Supporting Desk-top Conferencing System (데스크탑 회의시스템 지원을 위한 메시지 처리 시스템의 실시간 서비스 프리미티브 개발)

  • 강승찬;김영준
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.2 no.2
    • /
    • pp.169-180
    • /
    • 1998
  • This research presents development of real-time service primitive in MHS(Message Hanling system) supporting desk-top conferencing system. Desk-top conferencing system is one of the real-time GC(Group Communication) services. The complexity of modem society has led to the consequent need for real-time GC between a number of people in order to jointly handle tasks in business, government and other forms of organization. Despite the many different form of desk-top conferencing systems developed to date, there are still few systems in widespred no. One of the biggest hurdle preventing the widespred adoption of real-time GC is the lack of agreement on user-friendly interchange environments. In distributed office environments, the MHS is one of the most widely used service for information interchange. It is a standard of electronic mail system which is concerned mostly with asynchronous exchange of short notes. It is clear that additional functions on MHS are necessary in order to allow users to properly process their real-time group messages and provide them with important facilities as a communication infrastructure for real-time GC.

  • PDF

A Design and Implementation of Wi-Fi Based Unmanned Ship Control System (무선랜 기반 무인선박 제어시스템 설계 및 구현)

  • Kim, Dong-Hyun;Lee, Chae-Seok;Kim, Jong-Deok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.2
    • /
    • pp.437-444
    • /
    • 2014
  • The unmanned ship control system controls the unmanned ship at a distance in ocean. Expecially, in order to control the unmanned ship, it needs the wireless communication networks and we use the IEEE 802.11 based WLAN. The IEEE 802.11 based WLAN technology for supporting a wide bandwidth is suitable for unmanned ship control system which has to transmit the multimedia data. First, we design the system structure for controlling the unmanned ship. Then, in order to overcome the limited communication area, we design the network structure for the unmanned ship communication network which can use a various communication network. we implemented and evaluated the unmanned ship system based on WLAN. We controlled the unmanned ship by use the WLAN and confirmed the signal feature of WLAN in the ocean.

The Study on Impact of Introduction Characteristics Factor of EMR System on Perceived Usefulness and Ease of Use and Behavioral Intention to Use (EMR시스템의 도입 특성요인이 지각된 유용성, 편이성 및 사용의도에 미치는 영향에 관한 연구)

  • Im, Hyung-Joo;Shim, Jeong-Taek;Lee, Sang-Shik
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.2
    • /
    • pp.32-50
    • /
    • 2009
  • Since 1990 when order communication system(OCS) was first introduced, the use of information technology in medical service has been widely accepted in order to enhance quality and customer relationship as well as to increase managerial efficiency. Medical information system is rapidly increasing and is trying to make ubiquitous healthcare environment through telemedicine system. Especially, medical profession and government have taken interest in electronic medical record (EMR) system which can digitalize and manage all medical records in hospitals. By recording patient's medical information in real time, EMR system can improve service efficiency and customer service quality including short waiting time, various utilization of clinic information, and reduced cost.

Thermodynamic Analyses of the Constitutive Splicing Pathway for Ovomucoid Pre-mRNA

  • Ro-Choi, Tae Suk;Choi, Yong Chun
    • Molecules and Cells
    • /
    • v.27 no.6
    • /
    • pp.657-665
    • /
    • 2009
  • The ovomucoid pre-mRNA has been folded into mini-hairpins adaptable for the RNA recognition motif (RRM) protein binding. The number of mini-hairpins were 372 for pre-mRNA and 83-86 for mature mRNA. The spatial arrangements are, in average, 16 nucleotides per mini-hairpin which includes 7 nt in the stem, 5.6 nt in the loop and 3.7 nt in the inter-hairpin spacer. The constitutive splicing system of ovomucoid-pre-mRNA is characterized by preferred order of intron removal of 5/6 > 7/4 > 2/1 > 3. The 5' splice sites (5'SS), branch point sequences (BPS) and 3' splice sites (3'SS) were identified and free energies involved have been estimated in 7 splice sites. Thermodynamic barriers for splice sites from the least (|lowest| -Kcal) were 5, 4, 7, 6, 2, 1, and 3; i.e., -18.7 Kcal, -20.2 Kcal, -21.0 Kcal, -24.0 Kcal, - 25.4 Kcal, -26.4 Kcal and -28.2 Kcal respectively. These are parallel to the kinetic data of splicing order reported in the literature. As a result, the preferred order of intron removals can be described by a consideration of free energy changes involved in the spliceosomal assembly pathway. This finding is consistent with the validity of hnRNP formation mechanisms in previous reports.