• Title/Summary/Keyword: 2 order system

Search Result 14,807, Processing Time 0.045 seconds

The Current Status of Use and the Difference of Awareness by User Groups in the Cheongryongsan Vegetable Garden Park (청룡산 텃밭공원의 이용실태와 이용주체간 의식 차이)

  • Son, Yong-Hoon;Lim, Jung-Eon
    • Journal of Korean Society of Rural Planning
    • /
    • v.20 no.2
    • /
    • pp.71-80
    • /
    • 2014
  • This study intended for Cheongryongsan Community Garden in Gwanak-gu, one of the demonstration places for 'Community Garden' Project recently implemented by the Seoul Government. This study had two major purposes: investigating the current status of the management and usage and identifying its characteristics; investigating users' awareness to consider the construction and operation directions of sustainable community gardens. This study was conducted based on several surveys such as an investigation into the spatial configuration and the management system of parks through a field study, a use survey through a questionnaire survey for vegetable garden users and an awareness survey about the construction direction of gardens direction preferred by users through the analytical hierarchy process (AHP). As a result of a questionnaire survey for vegetable garden users, the usage status was summarized as follows: Considering the common trends in the 2012 and the 2013 user survey, women used Cheongryongsan Vegetable Garden more than men. Over fifties used it most of all users. Users were mostly neighborhood residents. They used to visit there three to five times a week and stayed for about 30 minutes to one hour. Users differently responded to the question related to the order of priority for the use of the garden in the 2012 and the 2013 survey. They had increasingly used it for individuals' production activities more than social exchanges. As a result of making an AHP analysis for general park users, vegetable garden users there were clear differences in the targets which each subject put emphasis on in relation to the construction and operation of vegetable gardens. General park users recognized a vegetable garden as a park where park functions and the functions of the vegetable garden coexisted. On the other hand, vegetable garden users viewed it as a space where they attached importance to the functions of the vegetable garden like an allotment. Last, this study contemplated subjects related to the construction and operation of vegetable gardens which had to be considered in the future. Vegetable gardens tended to be biased as personal hobby places. It was viewed that the main reason was insufficient support activities for vegetable garden education and exchange programs originally planned when vegetable gardens had been constructed. Vegetable garden users recognized vegetable gardens as places for individuals' farming activities like allotments. For the desirable operation of vegetable gardens, it would be necessary to give priority to the park management before the production activities in individuals' vegetable gardens. The important role of the government would be to build the base through the provision of education and opportunities so that a local resident organization could actively participate in the management of a vegetable garden after a vegetable garden was constructed. It would be necessary to make a use survey and an awareness survey for users conducted in this study on a regular basis because the surveys could be important basic data in the decision-making process for the sustainable operations of the vegetable garden.

Effects of Seed Pre-treatment and Germination Environments on Germination Characteristics of Ligularia fischeri Seeds (종자 전처리 및 발아환경에 따른 곰취 종자의 발아특성)

  • Jeon, Kwon Seok;Song, Ki Seon;Kim, Chang Hwan;Yoon, Jun Hyuck;Kim, Jong Jin
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.262-269
    • /
    • 2013
  • This study was carried out in order to examine the germination characteristics of Ligularia fischeri seeds, and it was to develop the more efficient pre-treatment and production system of the seeds. It was performed by two ways - temperature control (10, 15, 20 and $25^{\circ}C$) and shading treatment (Full sunlight, 35%, 50%, 75% and 95% of full sunlight). Seed pre-treatment before the each experiment was carried out by temperature (with low temperature and wetting treatment (LTW) for 0, 15, 30, 45 and 60days) and shading treatment (with drying at room temperature (DRT), drying at low temperature (DLT) and water soaking (WS) for 2 days). Seeds of L. fischeri were, regardless of seed pre-treatment, germinated well at $10^{\circ}C$ and the more temperature went up, the more germination rate went down. As a result of surveying shading treatment, 75% shading with DRT was the highest germination rate (68.1%) and 95% shading with WS was the lowest germination rate (48.6%). It was showed over-growth under 95% shading treatment experiment and withered in the full sunlight. As a result of surveying the whole experiment, L. fischeri seeds pre-treated with LTW for 15 days germinated well at $10^{\circ}C$ and under 50~75% shading treatment.

Development of Device Measuring Real-time Air Flow in Greenhouse (온실 공기유동 계측 시스템 개발)

  • Noh, Jae Seung;Kwon, Jinkyoung;Kim, Yu Yong
    • Journal of Bio-Environment Control
    • /
    • v.27 no.1
    • /
    • pp.20-26
    • /
    • 2018
  • This study was conducted to develop a device for measuring the air flow by space variation through monitoring program, which acquires data by each point from each environmental sensor located in the greenhouse. The distribution of environmental factors(air temperature, humidity, wind speed, etc.) in the greenhouse is arranged at 12 points according to the spatial variation and a large number of measurement points (36 points in total) on the X, Y and Z axes were selected. Considering data loss and various greenhouse conditions, a bit rate was at 125kbit/s at low speed, so that the number of sensors can be expanded to 90 within greenhouse with dimensions of 100m by 100m. Those system programmed using MATLAB and LabVIEW was conducted to measure distributions of the air flow along the greenhouse in real time. It was also visualized interpolated the spatial distribution in the greenhouse. In order to verify the accuracy of CFD modeling and to improve the accuracy, it will compare the environmental variation such as air temperature, humidity, wind speed and $CO_2$ concentration in the greenhouse.

A Study on the Effect of Engineering Computer Programming Instruction Using Project Learning (프로젝트 학습을 적용한 공학컴퓨터프로그래밍 수업 효과 연구)

  • Chae Su-Jin;Hwang Sung-Ho
    • Journal of Engineering Education Research
    • /
    • v.8 no.3
    • /
    • pp.57-68
    • /
    • 2005
  • The purpose of this study was to analyze the effect of Engineering computer programming instruction using project learning, to find out the ways to solve some revealed problems, and to improve the instruction. Unlike traditional lecture courses, students are encouraged to cultivate problem solving and teamwork skills through the programming project. In order to examine the effect of project learning, a survey was conducted with 49 students. The questionnaire consisted of 20 items with 5-grade scale each, the contents of which included learning value, workload, skills acquirement, assignment and comment. The SPSS, statistical analysis software was used to get statistics such as ANOVA, correlation and mean, etc. The results of this study showed (1) project learning was more efficient to acquire problem solving and teamwork skills compared with lecture learning, (2) there was significant correlation between self directed learning skill and information collecting skill, (3) cyber education system(i-campus) was helpful for students' self learning. But the results also showed that (4) students did not give high scores on items of the workload or difficulty of assignments. So we can conclude that it is necessary to develop the suitable projects for the capability of students to make the better project learning.

Improvement Manual for Waterworks Facilities to Reduce the Damage of Volcanic Ash (화산재 피해 저감을 위한 상수도시설 대응매뉴얼 개선방안)

  • Yoon, Hyoung-Uk;La, Da-Hye;Lee, Gyeng-Bin;Kim, Min Gyu;Chung, Il-Moon
    • The Journal of Engineering Geology
    • /
    • v.28 no.2
    • /
    • pp.267-276
    • /
    • 2018
  • Volcanic ash from volcanic eruptions spreads to vast areas hundreds of kilometers away, and when volcanic ash flows into surface waters, it will be damaged by water supply. In case of water supply facilities, it provides to people drinking water and domestic water, be consumed by the people cause social disorder when water supply is cut off due to damage such as water pollution caused by harmful materials of volcanic ash. However, when we looked at the disaster management manual, the establishment of a water supply facility manual to deal with the damage of volcanic ash was found to be insufficient. Therefore, in this study, the existing volcanic and water pollution related manuals were analyzed and problems were derived. In order to make quick situation judgment and response activities, we have suggested the scope of the water supply facility manual, disaster type, major missions and system of related organizations, and scenario of crisis situation by disaster type.

Performance Evaluation of Water Circulation Facilities with Infiltration and Retention Functions (침투 및 저류 기능을 가진 물 순환 시설의 효과 평가)

  • Hong, Jung Sun;Maniquiz-Redillas, Marla C.;Kim, Ree Ho;Lee, Seon Ha;Kim, Lee-Hyung
    • Ecology and Resilient Infrastructure
    • /
    • v.2 no.4
    • /
    • pp.305-310
    • /
    • 2015
  • In 2014, the city of Seoul revised the ordinance regarding water-cycle restoration in the Seoul Metropolitan areas by incorporating the 'Low Impact Development (LID)' policy. The new ordinance plan will utilize 630 mm or almost 45 to 50% of annual rainfall until 2050 by means of providing a rainwater management system consisting of infiltration, retention and vegetation. The LID is believed to be the key to achieving the target requirements, specifically in development projects. This research was performed to evaluate the stormwater runoff and pollutant reduction performance of three different LID facilities (water circulation facilities) including an infiltration inlet, bioretention swale, and permeable pavement constructed in Seoul City. Results show that among the water circulation facilities, the permeable pavement achieved the highest runoff reduction as it was able to entirely capture and infiltrate the runoff to the ground. However, in order to attain a long-term performance it is necessary to manage the accumulated sediment and trapped pollutants in the landscape areas through other water circulation techniques such as through soil erosion control. In terms of pollutant reduction capability, the infiltration inlet performed well since it was applied in highly polluted areas. The bioretention facility integrating the physico-chemical and biological mechanisms of soil, microorganisms and plants were able to also achieve a high runoff and pollutant reduction. The water circulation facilities provided not only benefits for water circulation but also various other benefits such as pollutant reduction, ecological restoration, and aesthetic functions.

Service Quality Assessment of University Libraries in Korea using LibQUAL+ : A Case Study (LibQUAL+를 활용한 국내 대학도서관 서비스 품질 측정 사례 조사)

  • Shim, Wonsik;Lee, Eun-Chul
    • Journal of the Korean Society for information Management
    • /
    • v.30 no.2
    • /
    • pp.245-268
    • /
    • 2013
  • The paper describes a case study in which Sungkyunkwan University Library participated in the official ARL(Assoication of Research Libraries) LibQUAL+ evaluation program. LibQUAL+ model is based on the SERVQUAL service quality evaluation model originally developed in the marketing area. It details a number of processes including translation of the LibQUAL+ survey instrument into Korean, selection of study sample and choice of survey versions. In addition, it offers a number of strategies that can be adopted in order to analyze the survey data for various comparisons among different user groups and institutions. LibQUAL+ is more that a survey instrument; it a holistic system for assessing library service quality. Despite criticisms on LibQUAL+, we expect that university libraries in Korean will benefit from participating in the program. It is preferable that a group of libraries form a consortium to participate in the LibQUAL+ program as opposed to individual participation. The consortium can function as a learning community through various workshops and sharing activities, thus elevate the overall evaluation efforts in Korean libraries to a higher level.

Studies on the Trial Manufacture of Telesounder and its Application (2) - Remote Observations of Fishes Entering in the Gape Nets With Wings - (원격어군탐지기의 시작 및 그 응용에 관한 연구 -II -낭장망 입망어군의 원격관측-)

  • 이원우
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.1
    • /
    • pp.54-62
    • /
    • 1995
  • In order to telemeter the behavior and distribution of fishes. the telesounder was manufactured and it was examined to verify its performance and effects in the gape nets with wings located around Gokunsan islands. Yellow Sea. on August 8. 18~19 and September 8~9, 1994. The behavior of fish entering the net was observed with the buoy station at sea which was installed at the entrance of the gape nets with wing and its echosignal was transmitted remotely to the base station on ship at distance of about 1 km away from the buoy station at sea. The fishes catched by the gape nets with wings were 12 species and Anchovy(Engraulis japonica), Beka squid(Loligo beka), Herring(Harengula zunasi) was 95% of total catches. The images of color display monitor at the base station on ship were very well coincident with the records of fish finder from the buoy station located at sea. When the current velocity was less than 0.6 kt and slight fluctuation, the fishes entered into the gape net were much more in comparision with over 1.0kt and heavy fluctuation, and then the average swimming depth was about 4 m. The catches per one hauling was about 10~30 kg and when the current velocity was too weak and the current direction did not coincident with the direction of net or the current velocity was too strong, the catches was a few. It is concluded that telesounder system is very useful for investigating the distribution and the swimming behavior of fishes entering in the gape nets with wings.

  • PDF

A Study on the Accelerated Life Test of BLDC Motor in Ceiling Mounted Digital Signage Rotating System (천정 거치형 디지털 사이니지 회전 시스템의 BLDC모터 가속수명시험에 관한 연구)

  • Kim, Ki-Hong;Kwon, Soon-Hong;Kwon, Soon-Gu;Park, Jong-Min;Kim, Jong-Soon;Jung, Sung-Won;Choi, Won-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.3
    • /
    • pp.141-147
    • /
    • 2018
  • In a time when product development cycles are getting shorter and shorter, many companies are making efforts to develop products with high reliability in a short period of time, accelerated life test is widely used as a method to quickly evaluate reliability. Accelerated life test reduces the test life or the life of the product from the observed data by shortening the lifetime of the product or abruptly lowering the performance under the worse condition than the actual condition in order to shorten the test cost or the test time. In this paper, BL3640A-06P+RB35, DC12V model, which is used in the support device of an automatic rotation type digital signage, which display various information such as textures and images on a display screen in a public place or a commercial space, BLDC motors were subjected to a constant stress test and at the rotational speed of 1rpm, $180^{\circ}$ rotation and reverse rotation under actual use conditions, the stress was imposed on the rotating speed of 2rpm and the weight of the actual installed product from 22.2kgf to 10kgf were installed. The lifetime of the actual use environment condition is 23,545 hours and the rotation speed is accelerated. The life time of the acceleration condition with the additional weight is 1,380 hours. The acceleration factor is calculated as 17.06, the one year guarantee test day is 235 days to 14 days, of the period from 470 days to 28 days, and the third year from 704 days to 42 days. The test date of the BLDC motor was tested on the shortened test date, and the rotational speed and the current value were measured. It is found that there is no defect even if it operates as the test date corresponding to the specified one year warranty period and the 3 year accelerated life test which is experimented. Using the statistical technique of the regression analysis the expected time for the motor to defect to #4 samples was 20 years.

A Study on the Thermal Characteristics of Jeju type Ground Heat Exchanger for Ground Source Heat Pump System applied to Jeju Island (제주도에 설치된 지열 열펌프 시스템용 제주형 지중열교환기의 열특성 연구)

  • Kim, Min-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.32-38
    • /
    • 2020
  • This study summarizes test methods and evaluation methods for examining the thermal characteristics of Jeju-type ground heat exchangers (GHXs) installed on Jeju Island, and analyzes the ground temperature and thermal characteristics of ground heat exchangers installed in various regions by using thermal response tests (TRT). Jeju Island is composed of volcanic rock layers, and the groundwater flow is well developed. A Jeju-type GHX can be installed up to 30 m from groundwater level after drilling a borehole. The ground heat exchanger has a structure in which several pipes are inserted into the borehole. In order to examine the characteristics of the Jeju-type GHX, tests were conducted on ground heat exchangers installed in four places on Jeju Island (Pyoseon, Jeju, Namwon, and Hallym). As a result of the analysis of the Jeju-type ground heat exchanger, the ground circulating water temperature stabilized according to the heat injection, depending on the installed location, and was formed within one to three hours. The ground heat exchanger capacity in Hallym was highest at 73.4 kW (cooling) and 82.8 kW (heating), and the Jeju-type calculation was lowest at 34.1 kW (cooling) and 23.3 kW (heating).