• Title/Summary/Keyword: 2 order system

Search Result 14,811, Processing Time 0.051 seconds

Capacity Variation of a Microcell due to Power Control Error in and Overlaid Macrocell/Microcell CDMA System (매크로셀내에 마이크로셀이 중첩된 CDMA 시스템에서 전력제어오차로 의한 마이크로셀의 용량 변화)

  • 강희곡;김영철;노재성;조성준
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.1
    • /
    • pp.8-17
    • /
    • 2000
  • The BER performance and the capacity variation of a microcell due to power control error(PCE) is analyzed on service types(data and voice, respectively) for the reverse link of an overlaid cell CDMA system. The procedure of analysis is followed as: First, we calculate BER performance according to PCE. Next, we find the minimum SNR for voice service, BER=TEX>$10^{-3}$, and data service, BER=TEX>$10^{-5}$. Then, according to the calculated SNR, we find the maximum capacity of a microcell and macrocell and the capacity of a microcell where interference is considered is found and analyzed with that in perfect power control. We get to the results as follows. The BER performance in 1 dB PCE is similar to that in perfect power control, however, with a increase in PCE, the BER performance is largely degraded. In terms of capacity, it is shown that if the PCE is equal or less than 2 dB, the effect of the PCE on voice service is more than that on data service, but if the PCE is equal or more than 3 dB, effect of the PCE on data service is more than that on voice. Besides, if the PCE is equal or less than 2 dB, both PCE and interference should be considered to calculate the capacity of a microcell, but if the PCE is equal or more than 3 dB, interference can be negligible since the effect of PCE is much stronger than that of interference. Therefore, the microcell should be located where $R_d$, the ratio of a microcell to a macrocell radius, is equal to 0.1, and d, the ratio of the distance between a microcell and a macrocell to the macrocell radius, is equal or more than 0.5, in order to obtain a appropriate microcell capacity against interference. If $\sigma$ is adjusted to less than 2 dB, we may get equal or more than 70% of the maximum microcell capacity.

  • PDF

Effect of thread design on the marginal bone stresses around dental implant (임플란트 나사산 디자인이 변연골 응력에 미치는 영향)

  • Lee, Sang-Hyun;Jo, Kwang-Heon;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.316-323
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the effect of different thread designs on the marginal bone stresses around dental implant. Materials and methods: Standard ITI implant(ITI Dental Implant System; Straumann AG, Waldenburg, Switzerland), 4.1 mm in diameter and 10 mm in length, was selected as control. Test implants of four different thread patterns were created based on control implant, i.e. maintaining all geometrical design of control implant except thread pattern. Four thread designs used in test implants include (1) small V-shape screw (model A), (2) large V-shape screw (model B), (3) buttress screw (model C), and (4) trapezoid screw (model D). Surface area for unit length of implant was 14.4 $mm^2$ (control), 21.7 (small V-shape screw), 20.6 (large V-shape screw), 17.0 (buttress screw) and 28.7 $mm^2$ (trapezoid screw). Finite element models of implant/bone complex were created using an axisymmetric scheme with the use of NISA II/DISPLAY III (Engineering Mechanics Research Corporation, Troy, MI, USA). A load of 100 N applied to the central node on the crown top either in parallel direction or at 30 degree to the implant axis (in order to apply non-axial load to the implant NKTP type 34 element was employed). Quantification and comparison of the peak stress in the marginal bone of each implant model was made using a series of regression analyses based on the stress data calculated at the 5 reference points which were set at 0.2, 0.4, 0.6, 0.8 and 1.0 mm from implant wall on the marginal bone surface. Results: Results showed that although severe stress concentration on the marginal bone cannot be avoided a substantial reduction in the peak stress is achievable using different thread design. The peak marginal bone stresses under vertical loading condition were 7.84, 6.45, 5.96, 6.85, 5.39 MPa for control and model A, B, C and D, respectively. And 29.18, 26.45, 25.12, 27.37, 23.58 MPa when subject to inclined loading. Conclusion: It was concluded that the thread design is an important influential factor to the marginal bone stresses.

Effect of Nitrogen Impurity on Process Design of $CO_2$ Marine Geological Storage: Evaluation of Equation of State and Optimization of Binary Parameter (질소 불순물이 이산화탄소 해양 지중저장 공정설계에 미치는 영향 평가: 상태방정식의 비교 분석 및 이성분 매개변수 최적화)

  • Huh, Cheol;Kang, Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.3
    • /
    • pp.217-226
    • /
    • 2009
  • Marine geological storage of $CO_2$ is regarded as one of the most promising options to response climate change. Marine geological storage of $CO_2$ is to capture $CO_2$ from major point sources, to transport to the storage sites and to store $CO_2$ into the marine geological structure such as deep sea saline aquifer. Up to now, process design for this $CO_2$ marine geological storage has been carried out mainly on pure $CO_2$. Unfortunately the captured $CO_2$ mixture contains many impurities such as $N_2$, $O_2$, Ar, $H_2O$, $SO_x$, $H_2S$. A small amount of impurities can change the thermodynamic properties and then significantly affect the compression, purification and transport processes. In order to design a reliable $CO_2$ marine geological storage system, it is necessary to perform numerical process simulation using thermodynamic equation of state. The purpose of the present paper is to compare and analyse the relevant equations of state including PR, PRBM, RKS and SRK equation of state for $CO_2-N_2$ mixture. To evaluate the predictive accuracy of the equation of the state, we compared numerical calculation results with reference experimental data. In addition, optimum binary parameter to consider the interaction of $CO_2$ and $N_2$ molecules was suggested based on the mean absolute percent error. In conclusion, we suggest the most reliable equation of state and relevant binary parameter in designing the $CO_2-N_2$ mixture marine geological storage process.

  • PDF

Optimum Design of Soil Nailing Excavation Wall System Using Genetic Algorithm and Neural Network Theory (유전자 알고리즘 및 인공신경망 이론을 이용한 쏘일네일링 굴착벽체 시스템의 최적설계)

  • 김홍택;황정순;박성원;유한규
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.4
    • /
    • pp.113-132
    • /
    • 1999
  • Recently in Korea, application of the soil nailing is gradually extended to the sites of excavations and slopes having various ground conditions and field characteristics. Design of the soil nailing is generally carried out in two steps, The First step is to examine the minimum safety factor against a sliding of the reinforced nailed-soil mass based on the limit equilibrium approach, and the second step is to check the maximum displacement expected to occur at facing using the numerical analysis technique. However, design parameters related to the soil nailing system are so various that a reliable design method considering interrelationships between these design parameters is continuously necessary. Additionally, taking into account the anisotropic characteristics of in-situ grounds, disturbances in collecting the soil samples and errors in measurements, a systematic analysis of the field measurement data as well as a rational technique of the optimum design is required to improve with respect to economical efficiency. As a part of these purposes, in the present study, a procedure for the optimum design of a soil nailing excavation wall system is proposed. Focusing on a minimization of the expenses in construction, the optimum design procedure is formulated based on the genetic algorithm. Neural network theory is further adopted in predicting the maximum horizontal displacement at a shotcrete facing. Using the proposed procedure, various effects of relevant design parameters are also analyzed. Finally, an optimized design section is compared with the existing design section at the excavation site being constructed, in order to verify a validity of the proposed procedure.

  • PDF

Development of Systematic Process for Estimating Commercialization Duration and Cost of R&D Performance (기술가치 평가를 위한 기술사업화 기간 및 비용 추정체계 개발)

  • Jun, Seoung-Pyo;Choi, Daeheon;Park, Hyun-Woo;Seo, Bong-Goon;Park, Do-Hyung
    • Journal of Intelligence and Information Systems
    • /
    • v.23 no.2
    • /
    • pp.139-160
    • /
    • 2017
  • Technology commercialization creates effective economic value by linking the company's R & D processes and outputs to the market. This technology commercialization is important in that a company can retain and maintain a sustained competitive advantage. In order for a specific technology to be commercialized, it goes through the stage of technical planning, technology research and development, and commercialization. This process involves a lot of time and money. Therefore, the duration and cost of technology commercialization are important decision information for determining the market entry strategy. In addition, it is more important information for a technology investor to rationally evaluate the technology value. In this way, it is very important to scientifically estimate the duration and cost of the technology commercialization. However, research on technology commercialization is insufficient and related methodology are lacking. In this study, we propose an evaluation model that can estimate the duration and cost of R & D technology commercialization for small and medium-sized enterprises. To accomplish this, this study collected the public data of the National Science & Technology Information Service (NTIS) and the survey data provided by the Small and Medium Business Administration. Also this study will develop the estimation model of commercialization duration and cost of R&D performance on using these data based on the market approach, one of the technology valuation methods. Specifically, this study defined the process of commercialization as consisting of development planning, development progress, and commercialization. We collected the data from the NTIS database and the survey of SMEs technical statistics of the Small and Medium Business Administration. We derived the key variables such as stage-wise R&D costs and duration, the factors of the technology itself, the factors of the technology development, and the environmental factors. At first, given data, we estimates the costs and duration in each technology readiness level (basic research, applied research, development research, prototype production, commercialization), for each industry classification. Then, we developed and verified the research model of each industry classification. The results of this study can be summarized as follows. Firstly, it is reflected in the technology valuation model and can be used to estimate the objective economic value of technology. The duration and the cost from the technology development stage to the commercialization stage is a critical factor that has a great influence on the amount of money to discount the future sales from the technology. The results of this study can contribute to more reliable technology valuation because it estimates the commercialization duration and cost scientifically based on past data. Secondly, we have verified models of various fields such as statistical model and data mining model. The statistical model helps us to find the important factors to estimate the duration and cost of technology Commercialization, and the data mining model gives us the rules or algorithms to be applied to an advanced technology valuation system. Finally, this study reaffirms the importance of commercialization costs and durations, which has not been actively studied in previous studies. The results confirm the significant factors to affect the commercialization costs and duration, furthermore the factors are different depending on industry classification. Practically, the results of this study can be reflected in the technology valuation system, which can be provided by national research institutes and R & D staff to provide sophisticated technology valuation. The relevant logic or algorithm of the research result can be implemented independently so that it can be directly reflected in the system, so researchers can use it practically immediately. In conclusion, the results of this study can be a great contribution not only to the theoretical contributions but also to the practical ones.

Educational Needs Analysis on NCS-based Intellectual Property Education (국가직무능력표준(NCS) 기반 지식재산교육을 위한 교육요구 분석)

  • Park, Ki-Moon
    • 대한공업교육학회지
    • /
    • v.43 no.1
    • /
    • pp.134-157
    • /
    • 2018
  • This study surveyed and analyzed satisfaction and issues about an intellectual property education system, and educational needs for intellectual property NCS (intellectual property management, intellectual property information survey analysis, intellectual property assessment trade), in order to introduce and operate NCS-based education system that trains practical manpower in the field. The results of this study are as follows. First, satisfaction for intellectual property education system showed education contents (M=3.86), followed by lecture (M=3.79), teaching method and environment (M=3.66) and education assessment (M=3.50). The issues to be improved are low application in the current occupation due to no reflection of demands of industrial fields, as well as insufficient education contents system, lectures who fall short of education capability and interactions with students tend to stress theoretical knowledge more than practical ability, teaching method lacks application of educational medium, insufficient interest and motivation, assessment methods that fall short of theoretical knowledge and practical ability achievement, and that is theory-centered. Second, educational needs for intellectual property NCS showed intellectual property assessment trade (4.33), followed by intellectual property management (3.68), and intellectual property information survey analysis (2.99), which should be reviewed to reform or newly develop NCS-based education course. Conclusively, intellectual property education showed satisfaction above the average, but a job-centered education is demanded to elevate application in the industrial field, which puts emphasis more on practical ability than theory. For this, it is necessary to introduce intellectual property NCS reflecting demands of industrial field, and to reform or newly develop into NCS-based education course. In addition, intellectual property education needs to be operated by changed education paradigm, such as user-centered teaching method, not provided-centered, and performance and course-centered assessment method, not theoretical knowledge-centered.

The Evaluation of Disinfection and Operation of Large Scale Anoxic Chamber System for Museum Insects (대용량 저산소 농도 살충 챔버 시스템을 이용한 박물관 해충의 살충력 및 운용성 평가)

  • Oh, Joon Suk;Choi, Jung Eun
    • Journal of Conservation Science
    • /
    • v.30 no.2
    • /
    • pp.137-148
    • /
    • 2014
  • Large scale anoxic chamber system(volume $28m^3$) was developed and installed at The National Folk Museum of Korea for the first time in Korea. In order to get optimal anoxic treatment condition, we compared the disinfection of adults, larvae and eggs of cigarette beetles using nitrogen and argon. The time for complete disinfection of cigarette beetles in pine wooden blocks exposed to nitrogen at oxygen concentration 0.01% and 50% in relative humidity were 15 days at $20^{\circ}C$, 10 days at $25^{\circ}C$, and 7 days $30^{\circ}C$. Time were 10 days at $20^{\circ}C$, 7 days at $25^{\circ}C$, and 5 days $30^{\circ}C$ in argon anoxic atmosphere. From the mortality of cigarette beetles, optimal disinfection condition was oxygen concentration 0.01%, $25^{\circ}C$ in temperature, 50% in relative humidity and exposure time 21 days at nitrogen atmosphere. And when large scale anoxic chamber system was supplied nitrogen by nitrogen generator for anoxic treatment of many collections or large collections, it could be operated stably. To verify optimal disinfection condition, museum insects(adults, larvae, pupae and eggs of cigarette beetles in pine wooden blocks, cotton fabrics and Korean paper book, adults and larvae of drugstore beetles in pine wooden blocks, cotton fabrics and Korean paper book, larvae of varied carpet beetles in pine wooden block and silk fabrics, adults and larvae of hide beetles and adults of rice weevils in breeding boxes) which exposed at optimal disinfection condition, were completely killed.

Analysis of the Thermal and Structural Stability for the CANDU Spent Fuel Disposal Canister (CANDU 처분용기의 열적-구조적 안정성 평가)

  • Lee, Jong-Youl;Cho, Dong-Geun;Kim, Seong-Gi;Choi, Heui-Joo;Lee, Yang
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.217-224
    • /
    • 2008
  • In deep geological disposal system, the integrity of a disposal canister having spent fuels is very important factor to assure the safety of the repository system. This disposal canister is one element of the engineered barriers to isolate and to delay the radioactivity release from human beings and the environment for a long time so that the toxicity does not affect the environment. The main requirement in designing the deep geological disposal system is to keep the buffer temperature below 100$^{\circ}C$ by the decay heat from the spent fuels in the canister in order to maintain the integrity of the buffer material. Also, the disposal canister can endure the hydraulic pressure in the depth of 500 m and the swelling pressure of the bentonite as a buffer. In this study, new concept of the disposal canister for the CANDU spent fuels which were considered to be disposed without any treatment was developed and the thermal stability and the structural integrity of the canister were analysed. The result of the thermal analysis showed that the temperature of the buffer was 88.9$^{\circ}C$ when 37 years have passed after emplacement of the canister and the spacings of the disposal tunnel and the deposition holes were 40 m and 3 m, respectively. In the case of structural analysis, the result showed that the safety factors of the normal and the extreme environment were 2.9 and 1.33, respectively. So, these results reveal that the canister meets the thermal and the structural requirements in the deep geological disposal system.

  • PDF

Functional Disturbances Through the Retinal Pigment Reaction of the Automatic Nervous System of Tadpoles Developed under Various Visible Rays (망막반응으로 본 각종파장가시광선조사하에서 발육한 과두(올챙이)의 식물신경계기능변조에 관하여)

  • 주인호
    • The Korean Journal of Zoology
    • /
    • v.1 no.2
    • /
    • pp.17-24
    • /
    • 1958
  • Since Kesser first described in 1934 the functional change of the autonomic nervous system caused by certain visible rays many researchers have unanimously approved that animals flashed with a red visible ray develop parasympathicotony while those flashed with a blue visible ray develop sympathicotony. On the other hand through studies made by our colleagues it is now well known that the inner-movement of the retinal pigments of frogs is stimulated in sympathicotony and is in reverse inhibited in parasimpathicotony. It is almost evident that the mechanism by which the inner-movement of the retinal pigments is due to sympathicotony derived from the excessive secretion of adrenalin. In addition , through may recent experiments on the pharmacological action of various medicines on the retinal pigments reaction of tadpoles , ranging from the excessive secretion of adrenalin. In addition , through my recent experiments on the pharmacologtical action of various medicines on the retinal pigments reaction of tadploes, raging from every developmental stage , Ifound that the movement of the retinal pigments by adrenalin is predominant in the earlier developmental stages of taopoles around 11 mm of body length, whereas other medicines fail to give any responce to the retinal pigments in such an earlier stage. When tadpoles grown to body length of 15-16m the retinal pigments move to the complete light position while kept in adrenalin solution. Based on these facts it might be well to consider that if tadpoles were grown under the visible rays for a given period, they might show a functional change of the autonomic nervous system and thereby cause of certain change in the physciological phases of the retinal reaction. Experiments were undertaken to find this matter and also to discover the simultaneous effects of the visible radiations on the developmental process of tadpoles. The results summarized as follows ; 1. The longest wave of visible rav has an effective reaction on the growth of body length of taopoles, while the shortest wave of visible ray causes the same for the metamorphoric differentiation of tadpoles. 2. When keeping two groups of tadpoles the first group of 15 mm body length grown for the period of one week and the latter group of 20 mm body length grown for two weeks under the various visible rays. swimming in adrenalin solution, the inner-movement of the retinal pigment occurs in both groups. The movement of pigments of the first group is accelerated in a sequence of blue ray \ulcorner green ray > brown ray> red ray, and that of the latter group is also accelerated in a sequence of blue ray>green ray > brown ray and red ray. 3. When keeping tow groups of tadpoles, the first group of 20 mm body length grown for the period of two weeks, the latter group of 25 m body length grown for three wheeks, under the various visible rays in sunlight, the inner-movement of the retinal pigments occurs in both groups. The movement of pigments of the first group is accelerated in a sequence of blue ray> green ray>brown ray and red ray, and that of the latter group is also accelerated in a sequence of blue ray > brow ray>red ray. 4. In order words, there facts manifest that tadpoles grown under the various visible rays reveal functional disturbances of the autonomic nervous system, at the time of 15 mm body length by adrenalin solution, which is a unique indicator illustrating the status of sympathicotony, and at the time of 20 mm body length by sunlight. This means that the longest visible ray cause sympathicotony, while the shortest visible ray causes parasympathicotony.

  • PDF

Efficacy of a Respiratory Training System on the Regularity of Breathing (호흡연습장치를 적용한 호흡교정법의 영향 평가)

  • Shin, Eun-Hyuk;Park, Hee-Chul;Han, Young-YIh;Ju, Sang-Gyu;Shin, Jung-Suk;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.26 no.3
    • /
    • pp.181-188
    • /
    • 2008
  • Purpose: In order to enhance the efficiency of respiratory gated 4-dimensional radiation therapy for more regular and stable respiratory period and amplitude, a respiration training system was designed, and its efficacy was evaluated. Materials and Methods: The experiment was designed to measure the difference in respiration regularity following the use of a training system. A total of 11 subjects (9 volunteers and 2 patients) were included in the experiments. Three different breathing signals, including free breathing (free-breathing), guided breathing that followed training software (guided-breathing), and free breathing after the guided-breathing (post guided-breathing), were consecutively recorded in each subject. The peak-to-peak (PTP) period of the breathing signal, standard deviation (SD), peak-amplitude and its SD, area of the one cycle of the breathing wave form, and its root mean square (RMS) were measured and computed. Results: The temporal regularity was significantly improved in guided-breathing since the SD of breathing period reduced (free-breathing 0.568 vs guided-breathing 0.344, p=0.0013). The SD of the breathing period representing the post guided-breathing was also reduced, but the difference was not statistically significant (free-breathing 0.568 vs. guided-breathing 0.512, p=ns). Also the SD of measured amplitude was reduced in guided-breathing (free-breathing 1.317 vs. guided-breathing 1.068, p=0.187), although not significant. This indicated that the tidal volume for each breath was kept more even in guided-breathing compared to free-breathing. There was no change in breathing pattern between free-breathing and guided-breathing. The average area of breathing wave form and its RMS in postguided-breathing, however, was reduced by 7% and 5.9%, respectively. Conclusion: The guided-breathing was more stable and regular than the other forms of breathing data. Therefore, the developed respiratory training system was effective in improving the temporal regularity and maintaining a more even tidal volume.