• Title/Summary/Keyword: 2 order system

Search Result 14,811, Processing Time 0.058 seconds

Scalp Dose Evaluation According Radiation Therapy Technique of Whole Brain Radiation Therapy (전뇌 방사선치료 시 치료방법에 따른 두피선량평가)

  • Jang, Joon-Yung;Park, Soo-Yun;Kim, Jong-Sik;Choi, Byeong-Gi;Song, Gi-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.2
    • /
    • pp.103-108
    • /
    • 2011
  • Purpose: Opposing portal irradiation with helmet field shape that has been given to a patient with brain metastasis can cause excess dose in patient's scalp, resulting in hair loss. For this reason, this study is to quantitatively analyze scalp dose for effective prevention of hair loss by comparing opposing portal irradiation with scalp-shielding shape and tomotherapy designed to protect patient's scalp with conventional radiation therapy. Materials and Methods: Scalp dose was measured by using three therapies (HELMET, MLC, TOMO) after five thermo-luminescence dosimeters were positioned along center line of frontal lobe by using RANDO Phantom. Scalp dose and change in dose distribution were compared and analyzed with DVH after radiation therapy plan was made by using Radiation Treatment Planning System (Pinnacle3, Philips Medical System, USA) and 6 MV X-ray (Clinac 6EX, VARIAN, USA). Results: When surface dose of scalp by using thermo-luminescence dosimeters was measured, it was revealed that scalp dose decreased by average 87.44% at each point in MLC technique and that scalp dose decreased by average 88.03% at each point in TOMO compared with HELMET field therapy. In addition, when percentage of volume (V95%, V100%, V105% of prescribed dose) was calculated by using Dose Volume Histogram (DVH) in order to evaluate the existence or nonexistence of hotspot in scalp as to three therapies (HELMET, MLC, TOMO), it was revealed that MLC technique and TOMO plan had good dose coverage and did not have hot spot. Conclusion: Reducing hair loss of a patient who receives whole brain radiotherapy treatment can make a contribution to improve life quality of the patient. It is expected that making good use of opposing portal irradiation with scalp-shielding shape and tomotherapy to protect scalp of a patient based on this study will reduce hair loss of a patient.

  • PDF

Evaluation of Fabricated Semiconductor Sensor for Verification of γ-ray Distribution in Brachytherapy (근접치료용 방사성 동위원소의 선량분포 확인을 위한 디지털 반도체 센서의 제작 및 평가)

  • Park, Jeong-Eun;Kim, Kyo-Tae;Choi, Won-Hoon;Lee, Ho;Cho, Sam-Joo;Ahn, So-Hyun;Kim, Jin-Young;Song, Yong-Keun;Kim, Keum-bae;Huh, Hyun-Do;Park, Sung-Kwang
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.280-285
    • /
    • 2015
  • In radiation therapy fields, a brachytherapy is a treatment that kills lesion of cells by inserting a radioisotope that keeps emitting radiation into the body. We currently verify the consistency of radiation treatment plan and dose distribution through film/screen system (F/S system), provide therapy after checking dose. When we check dose distribution, F/S systems have radiation signal distortion because there is low resolution by penumbra depending on the condition of film developed. In this study, We fabricated a $HgI_2$ Semiconductor radiation sensor for base study in order that we verify the real dose distribution weather it's same as plans or not in brachytherapy. Also, we attempt to evaluate the feasibility of QA system by utilizing and evaluating the sensor to brachytherapy source. As shown in the result of detected signal with various source-to-detector distance (SDD), we quantitatively verified the real range of treatment which is also equivalent to treatment plans because only the low signal estimated as scatters was measured beyond the range of treatment. And the result of experiment that we access reproducibility on the same condition of ${\gamma}$-ray, we have made sure that the CV (coefficient of variation) is within 1.5 percent so we consider that the $HgI_2$ sensor is available at QA of brachytherapy based on the result.

Perception and Utilization of Food Labeling System of Middle School Students in Gwangju (광주지역 중학생의 식품표시에 대한 인식 및 이용실태)

  • Kim, Yun-Ji;Jeon, Eun-Raye;Yoo, Maeng-Ja;Jung, Lan-Hee
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.6
    • /
    • pp.796-806
    • /
    • 2012
  • This study was conducted to investigate dietary attitude, and nutritional knowledge of middle school students in Gwangju and examine their perception and utilization of food labeling systems. The total and mean dietary attitude scores were 75 and 49.47, respectively. The total and mean nutrition knowledge scores were 15 and 10.88, respectively. Girls showed significantly higher nutrition knowledge than boys (p<0.01). Overall, 62.9% of respondents checked food labeling, and there were significant differences in dietary attitudes among groups that did and did not checking labeling (p<0.001), with higher dietary attitude being associated with checking the label. Moreover, higher nutritional knowledge was associated with checking the food label. Individuals who checked the food label considered the expiration date (54.9%), product name (14.4%) and price (10.2%). The main reasons for checking food labeling were (in descending order) to confirm the expiration date (61.6%), determine the ingredients and nutritional information, learn how to store the product, and compare the price and weight with other products. The overall satisfaction with the food labeling system was 16.20 out of 30, and significant differences (p<0.001) were observed among individuals with high, moderate and low dietary attitudes, as indicated by satisfaction scores of 17.54, 16.32 and 14.86, respectively. Individuals with high, moderate and low dietary attitudes had nutritional knowledge scores of 15.79, 16.08, and 17.08 respectively. The overall score for understanding nutrition labeling was 4.71 out of 7, and the understanding differed significantly among groups (p<0.01), with those with moderate food attitudes having the highest score.

Evaluation of the usefulness of Bolus, which combines Step Bolus and 3D Bolus (Step Bolus와 3D Bolus를 combine 한 Bolus의 유용성 평가)

  • Lee, Chang-Suk;Chae, Moon-Ki;Park, Byung-Suk;Kim, Sung-Jin;Joo, Kyoo-Sang;Park, Chul-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.79-88
    • /
    • 2021
  • Objectives: Bolus, which combines 3D-bolus and Step-bolus, was produced and its usefulness is evaluated. Materials and Methods: A Bolus was manufactured with a thickness of 10mm and 5mm using a 3D printer (3D printer, USA), and a Step Bolus of 5mm was bonded to a 5mm thick bolus. In order to understand the characteristics of Step bolus and 3D bolus, the differences in relative electron density, HU value, and mass density of the two bolus were investigated. These two Bolus were applied to anthropomorpic phantom to confirm its effectiveness. After all contouring of the phantom, a treatment plan was established using the computed treatment planning system (Eclipse 16.1, Varian medical system, USA). Treatment plan was performed using electron beam 6MeV, nine dose measurement points were designated on the phantom chest, air-gap was measured at that point, and dose evaluation was performed at the same point for each bolus applied using a glass dosimeter (PLD). Results: Bolus, which combines 3D-bolus 5mm and Step-bolus 5mm, was manufactured and evaluated compared with 3D-bolus 1cm. The relative electron density of 3D Bolus was 1.0559 g/cm2 and the step Bolus was 1.0590 g/cm2, which was different by 0.01%, so the relative electron density was almost the same. In the lightweight measurement of air-gap, the combined bolus was reduced to 54.32% for all designated points compared to 3D-bolus. In the dose measurement using a glass dose meter (PLD), the consistency was high in phantom using combined bolus at most points except the slope point. Conclusion: Combined bolus made by combining 3D-bolus and Step-bolus has all the advantages of 3D-bolus and Step-bolus. In addition, by dose inaccuracy due to Air-gap, more improved dose distribution can be shown, and effective radiation therapy can be performed.

Effect of Non-perforated Breathable Films on the Shelf Life and Quality of Ferulae Mushroom (Pleurotus ferulae) during MA Storage at Different Temperatures (몇가지 저장온도와 비천공 Breathable 필름이 아위버섯(Pleurotus ferulae) 저장수명과 품질에 미치는 영향)

  • Choi, In-Lee;Son, Jin Sung;Kim, Young Jae;Kwon, Tae Ho;Kang, Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.21 no.3
    • /
    • pp.261-266
    • /
    • 2012
  • This study was carried out in order to investigate the effect of MA packaging material on quality and shelf life of ferulae mushroom (Pleurotus ferulae) at 1, 8, and $24^{\circ}C$ storage temperatures. We found that the fresh weight loss was less than 1.5% in all temperatures (1, 8, and $24^{\circ}C$) and non-perforated breathable films (1,300 cc, 3,000 cc, 5,000 cc, 7,000 cc, 10,000 cc, 15,000 cc, 20,000 cc, and $40,000cc/m^2{\cdot}day{\cdot}atm$ oxygen transmission rate) treatments. The proper MA packaging material of ferulae mushroom was 1,300 cc and 3,000 cc films at $1^{\circ}C$ storage. Because 1,300 cc and 3,000 cc films showed proper level, 15% carbon dioxide and 5% oxygen concentration for MA storage, although the shelf life was higher in 1,300 cc (42 days) than 3,000 cc (38 days), and the ethylene concentration as well as off-order showed lower in 3,000 cc than 1,300 cc film. The 3,000 cc film was the most suitable for ferulae mushroom storage at $8^{\circ}C$, because atmosphere composition in package was not statistically significantly different among the film treatments. In addition, 3,000 cc film showed the second low ethylene concentration and the longest shelf-life of 19 days. The ferulae mushroom stored at $25^{\circ}C$ showed a vigorous respiration and resulted in an extreme CA condition in package at $5^{th}$ day after storage, and showed the highest visual quality in 1,300 cc film. As the shelf life of ferulae mushroom at $1^{\circ}C$ and $8^{\circ}C$ storage were 8 times and 4 times longer than at $25^{\circ}C$ storage respectively, so the ferulae mushroom should be stored and distributed in cold chain system.

The assessment and political subject of Revised Security Industry Law (개정 경비업법의 평가와 정책과제)

  • Lee, Sang-Hun
    • Korean Security Journal
    • /
    • no.36
    • /
    • pp.349-386
    • /
    • 2013
  • This research analyzes and evaluates The Korean Security Industry Law(TKSIL) putting the regulation of the present government about the private security industry. It nowadays becomes the important axis of the police services offered in the aspect of 'the national life safety' in connection with 'the materialization of society which is safe from the crime'. TKSIL is one of the national administration strategies which Park Gun-hye government aims on supervision policy. After seeking out the core values of the private security industrial policy which sets up in order to approach the national life safety which Park Gun-hye government aims, we make some assessments of this revised security industry law systematically. Particularly all keynote of policy about the private security of the police tried to be confirmed and the desirable direction of policy tries to be presented as to the security industry law application and real operation. In the site of organized civil complaint, the revised security industry law was revised as the direction which intensifies the administrative regulation as to the partial regulation such as it established the reason of the introduction of the arrangement license system. And grounds for disqualification of security instructor and guard, and rules of punishment is intensified order to intercept previously illegal and violent act of the security company etc. However it has the feature that it accomplishes 'the law principle(principle of statute)' the substantial portion through the effort of them changing a lot the content for the form of the law when being the clauses of the fundamental human rights limit, although it has been prescribed in "the security industry law enforcement ordinance" or "the security industry law enforced regulation". The security industry law revised this time brought from the change of the sharp policy through the revision of 17 clauses or new establishment. It can divide into 4 categorizes. (1) strictness of punishment in the site of organized civil complaint (2) Intensification of throwing out for the violation person in the private security business market time-limitedly (3) Intensification of the legal guide supervision power of police (4) upstream of the capital, name tag attachment under compulsion and the limit about other equipment use etc. Essentially "the security industry law" cannot help regulating the national interference of the private security and regulation with this content. However as to this interference and regulation, the limit has to be possible within reasonable range. As the history proved, excessive regulation by the country is not only due to bring the distortion of the security system of nation but also provoke national social cost. It can't be disregards ever that it premises the harmony which appropriate as well as reasonable in the socio-economic dimension for drawing the best combination that all things which get the compulsory education, it limits the person providing the private security service to the corporation, or it limits to the certificate of qualification holder are the ultimate for 'the safety of the national life'.

  • PDF

The Empirical Study on the Effects of the Team Empowerment caused by the Team-Based Organizational Structure in KBS (팀제가 팀 임파워먼트에 미치는 영향에 관한 연구;KBS 팀제를 중심으로)

  • Ahn, Dong-Su;Kim, Hong
    • 한국벤처창업학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.167-201
    • /
    • 2006
  • Korean corporations are transforming their vertical operational structure to a team-based structure to compete in the rapidly changing environment and for improved performance. However, a high percentage of the respondents in KBS said that despite the appearance of the present team structure, the organization operates much like a vertically-structured organization. This result can be attributed to the lack of study and implementation toward the goal of empowerment, the key variable for the success of the team-based structure. This study aims to provide policy suggestions on how to implement the process of empowerment, by investigating the conditions that hinder the process and the attitude of the KBS employees. For the cross-sectional study, this thesis examined the domestic and international references, conducted a survey of KBS employees, personal interviews and made direct observations. Approximately 1,200 copies of the Questionnaire were distributed and 474 were completed and returned. The analysis used SPSS 12.0 software to process the data collected from 460 respondents. For the longitudinal-study, six categories that were common to this study and "The Report of the Findings of KBS Employees' View of the Team Structure" were selected. The comparative study analyzed the changes in a ten-month period. The survey findings showed a decrease of 24.2%p in the number of responses expressing negative views of the team structure and a decrease of 1.29%p in the number of positive responses. The findings indicated a positive transformation illustrating employees' improved understanding and approval of the team structure. However, KBS must address the issue on an ongoing basis. It has been proven that the employee empowerment increases the productivity of the individual and the group. In order to boost the level of empowerment, the management must exercise new, innovative leadership and build trust between the managers and the employees first. Additional workload as a result of shirking at work places was prevalent throughout all divisions and ranks, according to the survey data. This outcome leads to the conclusion that the workload is not evenly distributed or shared. And the data also showed the employees do not trust the assessment and rewards system. More attention and consideration must be paid to the team size and job allocation in order to address this matter; the present assessment and rewards system need to be complemented. The type of leadership varies depending on the characteristics of the organization's structure and employees' disposition. KBS must develop and reform its own management, leadership style to suit the characteristics of individual teams. Finally, for a soft-landing of KBS team structure, in-house training and education are necessary.

  • PDF

Establishment of Miniaturized Cultivation Method for Large and Rapid Screening of High-yielding Monascus Mutants, and Enhanced Production of Monacolin-K through Statistical Optimization of Production Medium (Monascus 균사체의 소규모 배양을 통한 고생산성 균주의 대규모 선별방법 확립과 통계적 생산배지 최적화를 통한 Monacolin-K 생산성 향상)

  • Lee, Mi-Jin;Jeong, Yong-Seob;Kim, Pyeung-Hyeun;Chun, Gie-Taek
    • KSBB Journal
    • /
    • v.22 no.5
    • /
    • pp.305-312
    • /
    • 2007
  • It is crucial to develop a miniaturized cultivation method for large and rapid screening of high-yielding mutants of monacolin-K, a powerful anti-hypercholesterolemic secondary metabolite biosynthesized by the fungal cells of Monascus ruber. In order to investigate as many strains as possible in a short time, a miniaturized fermentation method especially suitable for the cultivation of the filamentous Monascus mutants was developed using $50m{\ell}$ culture-tube ($7m{\ell}$ of working volume) instead of the traditional $250m{\ell}$ flask ($50m{\ell}$ of working volume). Generally, in filamentous fungal cell fermentations, morphologies in growth and production cultures should be maintained as thick filamentous and compact-pelleted (usually less than 1 mm in diameter) forms, respectively, for enhanced production of secondary metabolites in final production cultures. In this study, we intended to induce the respective optimal morphologies in the miniaturized culture system for the purpose of rapid screening of overproducers. Miniaturized growth culture system was successfully developed due to the mass production of spores in the statistically optimized solid medium. When large amounts of spores were inoculated into the growth cultures, and brown rice flour (20 g/L) was also supplemented to the growth medium, dense filamentous morphologies were successfully induced in the growth cultures performed with the 50 ml culture tubes. It was implied that the amounts of spores inoculated into the growth tube-cultures and the growth medium components should be the key factors for the induction of the filamentous forms in the growth fermentations. Furthermore, in order to statistically optimize production medium, multiple experiments based on Plackett-Burman design and response surface method (RSM) were carried out, resulting in more than 2 fold enhanced production of monacolin-K in the final production cultures with the optimized production medium. Notably, under the production culture conditions with the statistically optimized medium, optimal pellet sizes below 1 mm in diameter were reproducibly induced, in contrast to the thick and viscous filamentous morphologies observed in the previous production cultures.

A study on the effect of air velocity through a damper on smoke extraction performance in case of fire in road tunnels (도로터널 화재 시 집중배기방식의 배기포트 통과풍속이 배연성능에 미치는 영향에 관한 연구)

  • Ryu, Ji-Oh;Na, Kwang-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.4
    • /
    • pp.347-365
    • /
    • 2020
  • In order to resolve traffic problems in urban areas and to increase the area of green spaces, tunnels in downtown areas are being increased. Additionally, the application of large port smoke extraction ventilation systems is increasing as a countermeasure to smoke extraction ventilation for tunnels with high potential for traffic congestion. It is known that the smoke extraction performance of the large port smoke extraction system is influenced not only by the amount of the extraction flow rate, but also by various factors such as the shape of the extraction port (damper) and the extraction air velocity through a damper. Therefore, in this study, the design standards and installation status of each country were investigated. When the extraction air flow rate was the same, the smoke extraction performance according to the size of the damper was numerically simulated in terms of smoke propagation distance, compared and evaluated, and the following results were obtained. As the cross-sectional area of the smoke damper increases, the extraction flow rate is concentrated in the damper close to the extraction fan, and the smoke extraction rate of the damper in downstream decreases, thereby increasing the smoke propagation distance on the downstream side. In order to prevent such a phenomenon, it is necessary to reduce the cross-sectional area of the smoke damper and increase the velocity of passing air through the damper so that the pressure loss passing through the damper increases, thereby reducing the non-uniformity of smoke extraction flow rate in the extraction section. In this analysis, it was found that when the interval distance of the extraction damper was 50 m, the air velocity passing through damper was 4.4 m/s or more, and when the interval distance of the extraction dampers was 100 m, the air velocity passing through damper was greater than 4.84 m/s, it was found to be advantageous to ensure smoke extraction performance.

The Study of Affecting Image Quality according to forward Scattering Dose used Additional Filter in Diagnostic Imaging System (부가필터 사용 시 전방 산란선량에 따른 화질 영향에 대한 연구)

  • Choi, Il-Hong;Kim, Kyo-Tae;Heo, Ye-Ji;Park, Hyong-Hu;Kang, Sang-Sik;Noh, Si-Cheol;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.597-602
    • /
    • 2016
  • Recent clinical field utilizes the aluminium filter in order to reduce the low-energy photons. However, the usage of the filter can cause adverse effect on the image quality because of the scattered dose that is generated by X-ray hardening phenomenon. Further, usage of filter with improper thickness can be a reason of dose creep phenomenon where unnecessary exposure is generated towards the patient. In this study, the author evaluated the RMS and the RSD analysis in order to have a quantitative evaluation for the effect of forward scattering dose by the filter on the image. as a result of the study, the FSR and the RSD was increased together with the increasing of thickness of the filter. In this study the RSD means the standard deviation of the mean value is relatively size. It can be understood that the signal-to-noise ratio decreases when the average value is taken as a signal and the standard deviation is judged as a noise. The signal-to-noise ratio can understanding as index of resolution at image. Based on these findings, it was quantitatively verified that there is a correlation of the image quality with the FSR by using an additional filter. The results, a 2.5 mmAl which is as recommended by NCRP in the tube voltage of 70 kVp or more showed the 14.6% on the RSD when the filter was not in used. these results are considered able to be utilized as basic data for the study about the filter to improve the quality of the image.