• Title/Summary/Keyword: 2차 발생원

Search Result 708, Processing Time 0.027 seconds

Survey of Secondary Infections within the Households of Newly Diagnosed Tuberculosis Patients (새로 진단된 결핵 환자의 가족 내 2차 감염 양상 조사)

  • Lee, Min Hyun;Sung, Jae Jin;Eun, Byung Wook;Cho, Hye-Kyung
    • Pediatric Infection and Vaccine
    • /
    • v.22 no.1
    • /
    • pp.7-15
    • /
    • 2015
  • Purpose: The purpose of this study is to investigate secondary infections within the households of newly diagnosed tuberculosis patients. Methods: We collected data on household infections of tuberculosis patients by retrospective review of medical records and telephone surveys. Results: Out of 321 newly diagnosed tuberculosis cases, a total of 253 patients who received telephone surveys were enrolled in this study. Less than 50% of the patients had household contacts screened for tuberculosis infection, and most of the patients were not aware of the necessity of testing. Out of 562 household contacts, there were 8 cases of secondary tuberculosis (1.4%, 8/562) in 7 households. There were 15 cases of latent infection (2.7%, 15/562) in 13 households. Out of 110 child and adolescent household contacts, there were no cases of secondary tuberculosis, and there were 8 cases of latent infection (7.3%) in 7 households, which was 20.5% among child and adolescent contacts screened for tuberculosis infection. In 3 of the cases (13.0%) that had secondary tuberculosis or latent infection in their households, the source of infection was extrapulmonary tuberculosis. There was no correlation between the frequency of household infections and the presence of pulmonary cavities, sputum AFB smear results, and microbiologically confirmed results. Conclusions: For effective investigation of tuberculosis contacts, it is necessary to raise general awareness on the necessity of investigating household contacts, and there should also be a continued assessment on tuberculosis contact investigation since government-supported programs.

PRIMARY MALIGNANT MELANOMA OF THE NOSE AND PARANASAL SINUSES ; REPORT OF A CASE (비강과 부비동에 발생된 원발성 악성 흑색종의 1예)

  • KOWN Ki Jeong;LEE Joo Hyun;HWANG Eui Hwan;LEE Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.23 no.2
    • /
    • pp.347-355
    • /
    • 1993
  • In the pigmented tumors, the diagnosis of malignant melanoma is not alway easy. Primary mucosal melanoma arising in the nose and paranasal sinuses is a rare disease with a generally poor prognosis. Melanoma in these area is frequently silent at the onset and produces insufficient symptoms to force the patient to the physician in the early stages of the disease. The importance of early recognition of melanoma by the physician is emphasized. We have an experience a case of primary malignant melanoma of the nose and paranasal sinuses in a 36-year-old female and present this case with a brief review of literatures.

  • PDF

Problem Analysis and Repair Techniques of Underground Concrete Box Structures (지하 박스 콘크리트 구조물(지하철)의 결함 원인 및 대책)

  • 변근주;오병환;신용석;송하원;원대연;남진원
    • Magazine of the Korea Concrete Institute
    • /
    • v.14 no.2
    • /
    • pp.70-76
    • /
    • 2002
  • 지하철, 고속철도, 신공항, 공동구, 지하보도, 지하차도, 하수도, 도로 및 철도 등 의 지하구조에는 일반적으로 박스형태의 콘크리트 구조물이 건설되고 있다. 1990년 대 중반 이후 시공 및 사용중인 지하 박스 콘크리트 구조물의 균열 및 누수 등의 문제점이 사회적인 문제로 부각되기 시작하였다. 이러한 지하 박스 콘크리트 구조물에 발생할 수 있는 문제점은 크게 결함(defect), 손상(damage), 열화(deterioration)의 3가지로 구분될 수 있으며, 이들 원인은 구조물에 균열(cracking), 누수(leakage), 처짐(deflection), 부동침하(settlement) 재료분리(segregation) , 박리(delamination), 부식(corrosion), 박락(spalling)등의 현상으로 나타난다.(중략)

New Double-Connected Multi-Step Inverter for High Power Motor Drive Applications (대용량 모터드라이브 적용을 위한 새로운 이중접속방식의 멀티스뎁 인버터)

  • Yang S.U.;Mok H.S.;Choe G.H.;Choi S.W.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.598-601
    • /
    • 2003
  • 본 논문에서는 전압원 인버터의 출력전압 파형을 개선하여 중 $\cdot$ 대용량급 모터드라이버 및 UPS, STATCOM, SVC등에 적용하기 위한 새로운 3상 전압원 인버터를 제안한다. 보조회로로서 사용한 컨버터로 리플전압을 발생시키고 이를 기존의 12-스텝 인버터에 주입하는데 한대의 링크를 사용하면 12-스텝 동작이 24-스텝으로 전환되며 보조 변압기의 1차 권선을 2N(N=1,2,3...)으로 늘리면 24N-스텝으로 전환된다. 본 방식의 타당성을 실험 및 시뮬레이션을 통하여 입증하였다.

  • PDF

Norovirus Food Poisoning and Laboratory Surveillance for Viral Gastroenteritis (바이러스성 식중독의 특성 및 예방법)

  • Jee, Young-Mee
    • Food Industry And Nutrition
    • /
    • v.11 no.3
    • /
    • pp.6-11
    • /
    • 2006
  • 바이러스성 식중독은 장염을 일으키는 원인 병원체 중 노로바이러스에 의해 흔히 발생하며 이외에도 아스트로바이러스나 로타바이러스에 의한 집단 설사 사례가 국내에서 보고된 바 있다. 노로바이러스는 식중독과 관련하여 특히 오염된 식수와 굴 등 어패류의 생식을 통한 감염 사례가 많이 보고되어 있으나 사람 간 전파도 흔히 일어나는 전염력이 매우 높은 바이러스이다. 국내에서는 1999년 이후 보고가 되고 있으며 최근 집단 급식과 관련된 대형 식중독 사례들이 보고되면서 학교급식이 사회적인 이슈로 대두되고 있다. 2000년 이후 질병관리본부는 바이러스성 설사의 국내 발생현황을 파악하기 위하여 전국의 17개 시도보건환경 연구원과 노로바이러스를 포함한 4종의 바이러스성 장염원인 병원체에 대한 전국적인 실험실 감시체계를 운영한 결과 바이러스성 병원체가 확인된 사례의 약 18%에서 노로바이러스가 검출되었고, 집단설사 사례에서는 대부분 노로바이러스가 원인병원체로 확인되었다. 또한 노로바이러스의 조기 검출을 위해 질병관리본부는 2004년 중 노로바이러스 유전자 검출 kit를 자체적으로 제작하여 이를 전국의 시도 보건환경연구원을 연계한 감시체계에서 적극 활용함으로써 노로바이러스 집단설사사례의 조기 검출이 가능하게 되었고 지역내 노로바이러스 검출율을 높이는데 기여하였다. 국립보건연구원은 2003년과 2006년에 발생한 대규모 노로바이러스 식중독 사례 이외에도 산발적으로 지속적으로 발생하는 사례들을 조기에 탐지하고 국내에서 검출되는 설사바이러스 유전형 분포양상과 새로운 유전자형이나 변이주를 조기에 검출하고자 전국적인 노로바이러스 실험실 감시망을 강화하여 운영하고 있으며, 집단설사 발생시 각 사례의 연관성을 신속하게 분석할 수 있는 실시간 분자역학적 유전자 분석체계를 단계적으로 도입하고 있다. 실험실 감시체계 운영과 함께 집단 식중독 유발 병원체의 효율적인 관리를 위해 질병관리본부는 노로바이러스를 포함한 설사 유발 병원체를 신고대상 병원체로 지정(2006.06.12)하여 병원체 검출시 보고하도록 하고 관련 지침을 마련하였다. 노로바이러스가 지정전염병 병원체로 추가로 지정됨에 따라 집단 사례 및 실험실 감시사업을 통해 검출되는 병원체에 대한 보고가 강화되고 전파 방지와 2차 감염 사례 감소에도 기여할 수 있을 것으로 사료되며 전국의 실험실 감시망을 연결하는 국가 차원의 노로바이러스 실시간 분자역학적 분석체계 도입을 통해 노로바이러스 2차 감염을 줄이고 대규모 집단발병 및 유행의 조기 차단 효과를 가져올 수 있을 것이다.

  • PDF

Direct Comparison of Two Mislocalization Phenomena: The Pulfrich Phenomenon and Flash Lag Effect (두 위치 오류 현상의 직접적인 비교: Pulfrich 현상과 명멸 지체 효과)

  • Kham, Kee-Taek
    • Korean Journal of Cognitive Science
    • /
    • v.18 no.3
    • /
    • pp.223-244
    • /
    • 2007
  • Two well known mis-localization effects, flash-lag effect (FLE) and the Pulfrich effect, have similar phenomena and theoretical explanations. In order to directly compare two phenomena, thereby examining the possibility that two phenomena have a common mechanism, the magnitudes of two effects were measured under the same experimental settings and stimuli. The Pulfrich depth was measured from each of four different brightness ratios of two moving stimuli, each of which was projected to each eye. The magnitude of FLE was measured from each of five different brightness levels, which were the same levels used in the Pulfrich experiment. The Pulfrich depth was increased with the increase of brightness ratio, whereas similar pattern was not found in the magnitude of FLE. Furthermore, actual Pulfrich depths were greatly different from those predicted from the difference of two FLEs. These results suggest that two phenomena may not have a common mechanism.

  • PDF

Delayless MDCT for Scalable Speech Codec (계층구조 음성 부호화기를 위한 지연 없는 MDCT 구조)

  • Sung, Ho-Sang;Park, Ho-Chong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.3
    • /
    • pp.102-108
    • /
    • 2007
  • A high-Performance scalable speech codec generally requires a very low-rate first layer and a fine granule second layer, and this codec can be implemented with the harmonic codec and the MDCT-based transform codec for each layer. In this structure, however. each codec requires independent frequency transform and the time delay of each codec is accumulated. resulting in long time delay for the overall codec. In this paper, new MDCT structure in the second layer is Proposed. where MDCT is forced to share the look-ahead region of the first layer in order to prevent the time delay accumulation and the resulting functional error of MDCT is analyzed and removed after IMDCT The Proposed delayless MDCT requires no additional bits and Provides the equivalent coding performance with the reduced time delay, yielding a meaningful enhancement of the overall codec.

A study on the parameters for biodegradable characteristics of sewage discharged intermittently (부정기적 발생 오수의 유기물 생분해도 특성 parameter 산정에 관한 연구)

  • Han, Gee-Bong;Lee, Young-Sin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.3
    • /
    • pp.41-52
    • /
    • 2014
  • In this study, to estimate the biodegradability of sewage discharged intermittently, field scale sampling and analysis was conducted and the results were obtained as follows. According to results of the biodegradability of sewage discharged intermittently, average concentration of TCODcr is 325.5mg/L and ratio of TCOD fraction resulted 100%. Also, average concentration of SCODcr resulted 135.9mg/L and ratio of TCOD fraction resulted 41.8%. Average concentration of Ss showed 74.1mg/L and ratio of TCOD fraction resulted 22.8%. Average concentration of $S_I$ was analyzed to be 61.8mg/L and ratio of TCOD fraction was calculated to 19.0%. Xs which is particulate matter was analyzed to show 27.8mg/L and ratio of TCOD fraction also showed 8.5%. Average concentration of $X_H$ is 103.4mg/L and ratio of TCOD fraction resulted 31.8%. Inert particulate matter showed that average concentration of $X_I$ is 58.5mg/L and ratio of TCOD fraction resulted 18.0%. Accordingly, dissolved biodegradable organic matter showed the ratio of 41.8%, and readily biodegradable matter among this showed 22.8%. Thus intermittent inflow is expected to have less effect with regards equalization by organic loading rate of influent.

Two-dimensional Flow Analysis Model Incorporating Secondary Current Effects in Meandering Channels (사행수로에서의 이차류 영향을 반영한 이차원 흐름 해석 모델)

  • Shin, Jaehyun;Seo, Il Won;Noh, Hyoseob
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.140-140
    • /
    • 2018
  • 다수의 자연 하천은 사행의 형태를 가지고 있으며 자연 상태에서의 직선 하천 형태는 비율이 20% 이하이다. 이러한 하천의 사행 형상으로 인하여 편수위 발달, 횡방향 압력의 불균형, 그리고 수심차에 의한 원심력이 발생하여 이차류 흐름이 발생된다. 정확한 이차류 구현을 위해서는 3차원 모형을 사용하는 것이 바람직하나, 3차원 모형의 격자 구성과 사용에서는 상당한 시간 및 노력이 요구되기 때문에 수심적분 2차원 모형을 사용하면서도 이차류의 영향을 구현하기 위한 연구들이 이루어졌다. 본 연구에서는 이러한 이차류의 영향을 2차원 모형으로 구현하고자 하였으며 이를 위해 이차류 연직 분포에 대한 기존 연구를 검토하여 새로운 이차류 공식을 개발하였다. 그리고 한국건설기술연구원 하천실험센터의 실규모 실험을 통해서 이차류 공식에 사용되는 계수를 보정하였다. 이처럼 개발된 식은 이차원 수리해석 모형인 HDM-2D에 적용되었다. HDM-2D는 수심 적분된 2차원 운동량 방정식을 지배방정식으로 사용하는 수리해석모형으로서, 이차류의 영향을 반영하기 위하여 개발한 황방향 유속의 연직분포식을 분산 응력항에 대입하여 이차류에 의한 전단 효과를 구현하였다. HDM-2D 흐름 모의 수행 결과와 하천실험센터 실험결과와 비교하여 이차류 효과가 주 흐름 유속의 분포에 미치는 영향을 확인하였다. 분석 결과, 모의 결과는 실험에서 발생하는 유속의 주 흐름 분포가 바깥쪽으로 편중되는 현상을 적절하게 재현함을 알 수 있었다. 모의 결과를 통해 HDM-2D 모형이 이러한 이차류 영향을 구현할 수 있음을 확인하였으며, 사행수로에서 주 흐름분포의 재분배는 하천 환경에서 유사 이동 및 오염물 이동에 큰 영향을 미칠 것으로 판단된다.

  • PDF

A case of discharge estimation for unmeasured operation period by real-time discharge measurement (자동유량측정시설 미계측 운영기간에 대한 유량산정 적용사례)

  • Cho, Sang Uk;Oh, Dong Heon;Baek, Jong Seok;Kim, Chi Young;Cha, Jun Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.320-320
    • /
    • 2020
  • 하천이용을 위한 다양한 개발사업이 이루어지고 있고 대규모 보가 설치되면서 과거와는 다른 변화된 수리조건에서 기존의 방법으로는 유량자료 생산이 더욱 어려워졌기 때문에 자동유량측정시설의 필요성이 증대되어 조위나 배수 영향을 받는 지점에서 기존 방식을 대체하거나 보완할 수 있는 새로운 유량측정방법으로 자리매김하게 되었다. 자동유량측정시설은 2020년 4월 현재 기준으로 한강 19개소, 낙동강 23개소, 금강 10개소, 영산간 10개소 총 62개소가 운영 중이다. 하지만 4대강 사업 이후, 수질 문제 등의 이유로 2017년 6월부터 순차적으로 4대강 보를 개방하여 보 운영수위에 따라 유속측정이 곤란한 관측소가 증가하고 있으며 이로 인해 환경부 수자원정보센터에서는 보 운영 별 최저수위에서도 자동유량측정시설 운영이 가능하도록 시설물을 개선하는 사업을 실시하고 있다. 개선사업 기간 동안 자료생산의 공백이 발생하지 않도록 인력에 의한 유량측정성과를 확보하여 관측소별 대안유량 산정방법을 개발하였다. 개발된 대안유량은 관측소 개선공사 기간뿐만 아니라 보 운영에 따른 수위저하로 인한 미계측 기간에도 적용하여 유량자료의 손실을 최소화 하도록 하였다. 2019년 운영현황을 범위로 전체 관측소 62개 중 4대강 보 구간에서 관측소 개선공사 8개소와 수위 저하로 유속측정이 불가능한 12개소 중 수위-유량관계곡선식 적용이 가능한 2개소를 제외한 10개소를 대상으로 평균 76일 결측이 발생한 것에 대해 대안유량 산정방법을 적용하여 전 기간 유량자료를 보완하였다. 그 결과 전체 2019년 자동유량측정시설 유량산정률은 99.8%로 자료생산의 공백을 최소화 할 수 있었으며 향후, 보 구간 자동유량측정시설 개선이 완료된 후에도 장비 이상 또는 이상치 발생 시에도 대안유량 산정방법을 활용하여 자료생산의 공백을 최소화 할 수 있을 것으로 기대하고 있다.

  • PDF