• Title/Summary/Keyword: 2차원 영상

Search Result 2,393, Processing Time 0.031 seconds

Optical implementation of unidirectional integral imaging based on pinhole model (핀홀 모델 기반의 1차원 집적 영상 기법의 광학적 구현)

  • Shin, Dong-Hak;Kim, Nam-Woo;Lee, Joon-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.2
    • /
    • pp.337-343
    • /
    • 2007
  • Since three-dimensional (3D) images reconstructed in interval imaging technique are related to the resolution of elemental images, there has been a problem that ray information of elemental images increases largely in order to obtain high-resolution 3D images. In this paper, to overcome this problem, a new unidirectional integral imaging based on pinhole model is proposed. Proposed method provides a new type of unidirectional elemental images, which are simply obtained by magnifying single horizontal pixel line of each elemental image to the vertical size of lenslet using ray analysis based on pinhole model and used to display 3D images. In proposed method, reduction effect of the ray information of elemental images can be obtained by scarifying vortical parallax. Feasibility of the proposed scheme is experimentally demonstrated and its results are presented.

Visualization of Brain Vessel for MRA Image (MRA영상에서 뇌혈관의 가시화)

  • 김영철;김령주;남상희;문치웅;최흥국
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2002.05c
    • /
    • pp.286-289
    • /
    • 2002
  • 뇌 혈관 영상은 2D로 되어있어 임상에서 뇌의 이상 유무와 질병의 진행 정도를 판별하는데 어려움이 있다. Volume Rendering은 2차원 데이터를 3차원 영상으로 재구성하여 오브젝트의 내부 모습을 3차원으로 볼 수 있게 해주는 장점이 있어 진단에 도움을 줄 수가 있다. MRA(Magnetic Resonance Angiography) 는 MRI(Magnetic Resonance Imaging)을 이용하여 Vascular Imaging 하는 기법이다. MRA 혈관 영상을 가시화하는 방법으로 MIP(Maximum Intensity Projection)를 이용하였다. 본 논문에서는 256×256 크기의 MRA영상 48장을 MIP 로 볼륨 랜더링하여 뇌 혈관 영상을 3차원으로 가시화 하였다.

  • PDF

A Study on registration using homography for 3D modeling (호모그래피를 이용한 3D 모델링을 위한 데이터 정합에 관한 연구)

  • Kim, Sang-Hoon
    • Journal of Digital Contents Society
    • /
    • v.15 no.4
    • /
    • pp.521-526
    • /
    • 2014
  • The purpose of this study is to propose the efficient method of 3D data registration. Three-dimensional data including the two-dimensional image acquisition apparatus and the position information are acquired at an arbitrary angle with each other. This paper proposes the more accurate and faster matching method by using this information. Four image points founded from 2D images match the volumetric size of the model and compute the homography of the axis for registration between two 3D data sets. The advantages of the proposed algorithm are the repeating process is unnecessary and the process time is faster than prvious method.

Stereo Sequence Transmission using Concealment of Disparity Information on Color Channels (변이 정보의 칼라채널별 은닉을 통한 스테레오 동영상 전송 기법)

  • 이호근;하영호
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.40 no.2
    • /
    • pp.29-36
    • /
    • 2003
  • This paper proposes a new 3D image transmission technique using digital watermarking for compatibility with conventional 2D digital TV. To transmit 3D images effectively, generally, we use image sequence transmission using temporal-spatial redundancy between stereo images. It is difficult for users with conventional digital TV to watch the transmitted 3D image sequence because of effectivity of 3D image compression. To improve such problem, in this paper, we perceive the concealment of new information of digital watermarking and conceal information of the other stereo image into three channels of the reference image. So we can watch the image with 3D TV as well as conventional digital TV when it is decoded.

Robust Watermarking Algorithm for 3D Mesh Models (3차원 메쉬 모델을 위한 강인한 워터마킹 기법)

  • 송한새;조남익;김종원
    • Journal of Broadcast Engineering
    • /
    • v.9 no.1
    • /
    • pp.64-73
    • /
    • 2004
  • A robust watermarking algorithm is proposed for 3D mesh models. Watermark is inserted into the 2D image which is extracted from the target 3D model. Each Pixel value of the extracted 2D image represents a distance from the predefined reference points to the face of the given 3D model. This extracted image is defined as “range image” in this paper. Watermark is embedded into the range image. Then, watermarked 3D mesh is obtained by modifying vertices using the watermarked range Image. In extraction procedure, the original model is needed. After registration between the original and the watermarked models, two range images are extracted from each 3D model. From these images. embedded watermark is extracted. Experimental results show that the proposed algorithm is robust against the attacks such as rotation, translation, uniform scaling, mesh simplification, AWGN and quantization of vertex coordinates.

A Correction of the Keystone Distortion Using the Bilinear Interpolation Method in 3D Stereoscopic images (3차원 입체영상에서 양선형 보간법을 이용한 키스톤 왜곡 보정)

  • Lee, Seung-Woo;Song, Young-Jun;Kim, Nam
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2006.11a
    • /
    • pp.524-527
    • /
    • 2006
  • This paper discusses a method to efficiently remove the keystone distortion in images. The keystone distortion which generated during 2D image aquisition to realize 3D stereoscopic images is removed by the bilinear interpolation method. Usually, the keystone distortion in 2D images can remove by the optical equipment but the image processing is more effective than the optical equipment in consideration of efficiency or simplicity of the works. This method can be realized 3D stereoscopic image without the distortion.

  • PDF

A Implementation of 3D Virtual Face using two 2D photographs (두 장의 2D 사진을 이용한 3D 가상 얼굴 구현)

  • 임낙현;서경호;김태효
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.12a
    • /
    • pp.117-120
    • /
    • 2000
  • 본 논문에서는 2매의 2차원 얼굴영상으로부터 이들을 합성하여 3차원 얼굴의 가상형상을 복원한다. 여기서 2매의 2차원 얼굴영상은 정면과 측면 영상을 사용한다. 우선 임의의 일반 얼굴에 대한 기준모델을 설정하고, 이 모델에서, 얼굴형상의 특징을 표현하는 귀, 2개의 눈, 코 및 입 부분에 집중적으로 특징점을 규정하고, 그 외에 이마 및 턱 부분에도 특징 점을 규정하여 그 위치좌표를 저장해 둔다. 그 후 정면영상의 좌 우측에 측면영상을 대칭적으로 접속하고 영상의 기하변환 방법을 적용하여 점차적으로 합성한다. 이때 나타나는 합성부분에 색상 및 명도의 차를 제거하기 위해 선형보간법을 적용하여 자연스런 3차원 가상얼굴을 구현하게 된다. 그 결과 불특정 얼굴형상도 3차원으로 구현할 수 있음을 확인하였다.

  • PDF

A Study on Virtual Reality Management of 3D Image Information using High-Speed Information Network (초고속 정보통신망을 통한 3차원 영상 정보의 가상현실 관리에 관한 연구)

  • Kim, Jin-Ho;Kim, Jee-In;Chang, Chun-Hyon;Song, Sang-Hoon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.12
    • /
    • pp.3275-3284
    • /
    • 1998
  • In this paper, we deseribe a Medical Image Information System. Our system stores and manages 5 dimensional medical image data and provides the 3 dimensional medical data via the Internet. The Internet standard VR format. VRML(Virtual Reality Modeling Language) is used to represent the 3I) medical image data. The 3D images are reconstructed from medical image data which are enerated by medical imaging systems such ans CT(Computerized Tomography). MRI(Magnetic Resonance Imaging). PET(Positron Emission Tomograph), SPECT(Single Photon Emission Compated Tomography). We implemented the medical image information system shich rses a surface-based rendering method for the econstruction of 3D images from 2D medical image data. In order to reduce the size of image files to be transfered via the Internet. The system can reduce more than 50% for the triangles which represent the surfaces of the generated 3D medical images. When we compress the 3D image file, the size of the file can be redued more than 80%. The users can promptly retrieve 3D medical image data through the Internet and view the 3D medical images without a graphical acceleration card, because the images are represented in VRML. The image data are generated by various types of medical imaging systems such as CT, MRI, PET, and SPECT. Our system can display those different types of medical images in the 2D and the 3D formats. The patient information and the diagnostic information are also provided by the system. The system can be used to implement the "Tele medicaine" systems.

  • PDF

A study on three-dimensional image formation theory by using scatterers (산란체를 이용한 3차원 영상 구현 이론의 연구)

  • Chae Sung-Ouk;Jun Kye-suk
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.397-400
    • /
    • 2000
  • 초음파 영상의 3차원 구성은 기존의 2차원 영상에서는 얻을 수 없었던 결함의 깊이, 방향성 등의 정보를 획득할 수 있기 때문에 최근에 이에 대한 관심이 고조되고 있다. 본 연구에서는 SAM(Scanning Acoustic Micro-scope)의 각 스펙트럼(angular spectrum) 접근법을 사용하여 물체에서의 3차원 영상 구현 이론에 대해서 연구하였다. 이러한 방법은 초음파 트랜스듀서를 디포커싱 시키면서 얻어진 2차원영상 정보를 이용하여 3차원으로 구성하는 방법이다. 실험에서는 알루미늄 원형 시료를 사용하였고, V(z)이론을 이용하여 산란된 신호에서의 영상을 구현하는 데 초점을 두었다. 모의 실험을 통하여 피사체 중심에 대해서 $70^\circ$ 범위 내에서 반사형 초음파 현미경으로 영상을 얻어낼 수 있음을 확인하였다. 중심주파수가 5MHz이고 대역폭이 $35\%$인 트랜스듀서를 사용하여 원형 시료의 중심부에서의 영상을 얻어내었다

  • PDF

Development of 3D Projection Reconstruction MR Angiography

  • 김대흥;김은주;정은기
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.148-148
    • /
    • 2001
  • 목적: 자기 공명 혈관 영상(MR Angiography)법으로 혈관 촬영시, 혈관 협착으로 인하여 난류 현상이 발생되는 곳에서는 영상 자체가 얻어지지 않는다. 기존에 TE를 줄이거나 또는 projection reconstruction 방법은 2차원 TOF(Time of Flight)에 적용이 되어서 좋은 결과를 얻었다. 그런데, 2차원 TOF보다는 3차원 TOF으로 보다 좋은 혈관 영상을 얻을 수가 있다. 하지만, 3차원 TOF 방법에 projection reconstruction 방법을 적용하는 데는 여러 가지 문제점이 있어서 개발되어 있는 것이 거의 없다. 본 연구에서는 3차원 TOF 방법에 projection reconstruction 방법을 적용하여서 혈관내의 난류 현상에 의한 영상의 왜곡을 극복하는 방법을 개발한다. 대상 및 방법: 3차원 projection reconstruction을 위한 pulse sequence를 실제 진단에 사용하는 GE사의 자기공명영상장치(1.5T)에 맞게 독자적으로 개발한다. GE사의 장비에서 자료를 얻어서 일반 컴퓨터에서 영상을 재구성하는 알고리즘을 자체 개발한다. 혈관에서와 비슷한 형태의 난류를 발생시킬 수 있는 기구를 만들어서 실제 혈관영상에 사용하는 방법과 개발한 방법으로 영상을 비교한다.

  • PDF