• Title/Summary/Keyword: 2차원스캔

Search Result 191, Processing Time 0.03 seconds

2D Pattern Development of Body Surface from 3D Human Scan Data Using Standing and Cycling Postures (3D 스캔을 이용한 사이클 동작 전후 체표 변화 고찰 및 2D 전개 패턴의 비교)

  • Jeong, Yeonhee;Lee, Yejin
    • Korean Journal of Human Ecology
    • /
    • v.21 no.5
    • /
    • pp.975-988
    • /
    • 2012
  • Although the pattern development for tight-fitting clothing has been carried out using 3D data on humans, the pattern development using 3D scan data obtained for various postures still remains an interesting subject. In this study, we have developed the 2D pattern using the 3D human body reflecting standing and cycling postures. The 3D scan data of a subject was obtained using Cyberware. 2C-AN program(Triangle simplification and the Runge-Kutta method) was used in the system to reduce the 3D scan data points and to make segmented triangular patches in a plane from 3D data. As results, surface distance and area of each body part of standing and cycling postures were also provided for the future application of the functional clothing construction. The area of center piece on the front (c.front) decreased by $106.45cm^2$(-13.08%) and that of lateral piece(s.back) on the back increased by $144.96cm^2$(18.69%) in the patterns of cycling posture. The girth of neck and waist for the cycling posture increased by 0.88cm (3.92%) and 1.56cm(4.40%) respectively, and the that of thigh decreased by 1.01cm(-2.24%). The differences between the area in the 2D pattern obtained from the 3D scan data and that in the 3D scan surface data for standing and cycling postures were very small($-10.34cm^2$(-0.32%) and $-44.33cm^2$(-1.32%)).

Development of 2D Tight-fitting Pattern from 3D Scan Data (3D 스캔 데이터를 활용한 밀착 패턴원형 개발)

  • Jeong, Yeon-Hee;Hong, Kyung-Hi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.1 s.149
    • /
    • pp.157-166
    • /
    • 2006
  • The human body, which is composed of concave and convex curvatures, makes it difficult to transfer into 2D patterns directly from 3D data. In previous studies. Jeong, et al.(2004) suggested the block method was fester and easier when dealing with the triangular patches of male's upper dress form. Although the block method is useful to make a pattern, the information(area, length, etc.) from a 2D pattern would be different depending on the direction of the block method. As a result horizontal and diagonal block methods were suggested as optimal methods for 2D tight-fitting patterns. These block methods were closer to the original area of the 3D scan data than the vertical block method. The total area of the 2D pattern obtained by the horizontal and diagonal block methods showed little differences. In case of the horizontal and diagonal block methods, the total error of the 2D pattern area ranged from $0.01\%\~0.25\%$. In comparing the length of the 2D pattern with that of the 3D scan data, the obtained 2D pattern was $0.1\~0.2cm$ shorter than the 3D scan data, which was within the acceptable range of errors in making clothes. 3D space distribution images between the body surface and the experimental clothing were also measured and $3\%$ enlargement of the original pattern was verified as the adequate adjustment.

Subjective Wearing Assessment and Clothing Pressure depending on the Pattern Reduction Rate of Developed Cycle Pants Using the 3D Human Scan Data (3D 스캔 데이터를 이용하여 개발된 사이클 팬츠 패턴의 축소율에 따른 의복압 및 주관적 착의 평가)

  • Jeong, Yeonhee;Hong, Kyunghi
    • Korean Journal of Human Ecology
    • /
    • v.24 no.2
    • /
    • pp.255-266
    • /
    • 2015
  • In this study, we have developed the ergonomic pattern from the 3D human body reflecting cycling posture and extensibility of the stretch fabrics. Adjusting pressure level in the construction of athlete's tight-fitting stretch garments by reducing the original pattern is a challenging subject, which influence on the performance of the wearer directly. Therefore, in this study, relationships between the reduction rates of the 2D pattern obtained from the 3D human scan and resultant clothing pressure were explored to improve the fit and pressure exerted by reduced clothing pattern. Subjective wear sensations of the experimental garments were rated using a seven-point Likert scale on two consecutive days. While wearing the garments, subjects were asked to take five different postures including waist flexion, sitting and others. A Likert-type scale was used for the evaluation, with 7 points indicating the best fit in tight-fitting pants. Comparing 2/3T-pattern with T-pattern, the latter was superior to 2/3T-pattern in terms of adhere well to the waist and hip area in the 0.032 significance level. T-pattern was superior to 2/3T-pattern in terms of fitting and wear comfort. As results, the pattern obtained from the flexed body reflecting cycling posture already included the contraction and extension of the skin while cycling posture, so that the extra ease for movement and good fit was not need to be considered. The optimized reduction rates were determined with the proposed reduction rate, the resultant pressure range was within the range of $0.5{\sim}3.0gf/cm^2$ at eight locations on the body except front waist band and thigh band.

Technical Design of Tight Upper Sportswear based on 3D Scanning Technology and Stretch Property of Knitted Fabric (3차원 스캔 기술과 니트 소재의 신축성을 적용한 밀착형 스포츠웨어 상의 설계)

  • Kim, Tae-Gyou;Park, Soon-Jee;Park, Jung-Whan;Suh, Chu-Yeon;Choi, Sin-Ae
    • Fashion & Textile Research Journal
    • /
    • v.14 no.2
    • /
    • pp.277-285
    • /
    • 2012
  • This research studied how to develop tight upper sportswear from 3D scan data considering fabric stretch property. Subjects were five Korean men of average figure in their 20's. Scanning was done for ten postures via vitus smart/pro(Techmath LTD). Analyzing from 3D scan data, more than 70% of the upper body surface showed surface change rate under 20%. It was shoulder and under arm side part that showed most noticeable body surface change when moving. A parametric model with convex surface was generated and flattened onto the plane, resulting 2D pattern. The error rate occurring in the process of 3D to 2D conversion was 0.2% for outline and 0.13% for area, respectively. Thirteen kinds of stretchable fabrics in the market were collected for this study. Stretch property was in the range of 16.0~58.2% for wale direction; 23.1~78.4% for course. Based on wear trial test, four fabrics were chosen for making the 1st experimental garment and finally one fabric was chosen for the 2nd one, which was developed applying 4 kinds of crosswise reduction rate on 2D pattern: 0, 5, 10, and 15%. Through wear trial test and garment pressure measurement, experimental garment applied with 10% pattern reduction rate was evaluated as most comfortable and considerable.

From TMJ to 3D Digital Smile Design with Virtual Patient Dataset for diagnosis and treatment planning (가상환자 데이터세트를 기반으로 악관절과 심미를 고려한 진단 및 치료계획 수립)

  • Lee, Soo Young;Kang, Dong Huy;Lee, Doyun;Kim, Heechul
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.30 no.2
    • /
    • pp.71-90
    • /
    • 2021
  • The virtual patient dataset is a collection of diagnostic data from various sources acquired from a single patient into a coordinate system of three-dimensional visualization. Virtual patient dataset makes it possible to establish a treatment plan, simulate various treatment procedures, and create a treatment planning delivery device. Clinicians can design and simulate a patient's smile on the virtual patient dataset and select the optimal result from the diagnostic process. The selected treatment plan can be delivered identically to the patient using manufacturing techniques such as 3D printing, milling, and injection molding. The delivery of this treatment plan can be linked to the final prosthesis through mockup confirmation through provisional restoration fabrication and delivery in the patient's mouth. In this way, if the diagnostic data superimposition and processing accuracy during the manufacturing process are guaranteed, 3D digital smile design simulated in 3D visualization can be accurately delivered to the real patient. As a clinical application method of the virtual patient dataset, we suggest a decision-making method that can exclude occlusal adjustment treatment from the treatment plan through the digital occlusal pressure analysis. A comparative analysis of whole-body scans before and after temporomandibular joint treatment was suggested for adolescent idiopathic scoliosis patients with temporomandibular joint disease. Occlusal plane and smile aesthetic analysis based on the virtual patient dataset was presented when treating patients with complete dentures.

Fast 3D mesh generation using projection for line laser-based 3D Scanners (라인 레이저 기반 3차원 스캐너에서 투영을 이용한 고속 3D 메쉬 생성)

  • Lee, Kyungme;Yoo, Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.3
    • /
    • pp.513-518
    • /
    • 2016
  • This paper presents a fast 3D mesh generation method using projection for line laser-based 3D scanners. The well-known method for 3D mesh generation utilizes convex hulls for 4D vertices that is converted from the input 3D vertices. This 3D mesh generation for a large set of vertices requires a lot of time. To overcome this problem, the proposed method takes (${\theta}-y$) 2D depth map into account. The 2D depth map is a projection version of 3D data with a form of (${\theta}$, y, z) which are intermediately acquired by line laser-based 3D scanners. Thus, our 2D-based method is a very fast 3D mesh generation method. To evaluate our method, we conduct experiments with intermediate 3D vertex data from line-laser scanners. Experimental results show that the proposed method is superior to the existing method in terms of mesh generation speed.

A Morphometric Study of Primary Anterior Zirconia Crowns in Korean Tooth Models (한국 유치 모델에서 유전치 지르코니아 크라운의 형태계측학적 연구)

  • Park, Jungha;Lee, Sangho;Lee, Nanyoung;Jih, Myoungkwan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.1
    • /
    • pp.41-56
    • /
    • 2018
  • The purpose of this study was to provide clinical recommendations for restoration with selection of the most similar zirconia crown by 3-dimensional analysis of the shape of the maxillary primary central and lateral incisors in Korean individuals and prefabricated zirconia crowns. The average shape of the sound maxillary primary central and lateral incisors in 300 children was reproduced by 3-dimensional scanning. Zirconia crowns of 4 manufacturers (NuSmile $ZR^{(R)}$ Crown, Cheng $Crowns^{(R)}$, Kinder $Krowns^{(R)}$, and EZ $Pedo^{(R)}$ Crown) were scanned 3-dimensionally, and coordinates for comparison of the shape were measured to evaluate the similarity between the teeth and crowns. The most similar crowns were selected by comparing the mesiodistal length, crown height, crown shape ratio, distance between the same coordinates of a tooth and crown, the radius of curvature of the labial surface, and the volume. As a result of analysis, Cheng $Crowns^{(R)}$ size 3 and NuSmile $ZR^{(R)}$ Crown size 2 were the most similar crowns in the maxillary primary central and lateral incisors, respectively. Scanning the inner surface of the crowns and evaluating the amount of tooth reduction required suggested that an overall lesser amount of tooth reduction compared to that presented by the manufacturer's guidelines should be performed.

A 3D Face Modeling Method Using Region Segmentation and Multiple light beams (지역 분할과 다중 라이트 빔을 이용한 3차원 얼굴 형상 모델링 기법)

  • Lee, Yo-Han;Cho, Joo-Hyun;Song, Tai-Kyong
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.38 no.6
    • /
    • pp.70-81
    • /
    • 2001
  • This paper presents a 3D face modeling method using a CCD camera and a projector (LCD projector or Slide projector). The camera faces the human face and the projector casts white stripe patterns on the human face. The 3D shape of the face is extracted from spatial and temporal locations of the white stripe patterns on a series of image frames. The proposed method employs region segmentation and multi-beam techniques for efficient 3D modeling of hair region and faster 3D scanning respectively. In the proposed method, each image is segmented into face, hair, and shadow regions, which are independently processed to obtain the optimum results for each region. The multi-beam method, which uses a number of equally spaced stripe patterns, reduces the total number of image frames and consequently the overall data acquisition time. Light beam calibration is adopted for efficient light plane measurement, which is not influenced by the direction (vertical or horizontal) of the stripe patterns. Experimental results show that the proposed method provides a favorable 3D face modeling results, including the hair region.

  • PDF

Cancellation of MRI Artifact due to Rotational Motion in Image Plane (화상평면내 회전운동에 의한 MRI 아티팩트의 제거)

  • 김응규;이충호
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.04b
    • /
    • pp.601-603
    • /
    • 2002
  • MRI 스캔중 촬상 대상물의 화강평면내에서의 회전은 MRI 신호에 위상오차와 불균일 표본화를 일으킨다. 따라서, 아티팩트가 포함된 MR 화상의 화질열화를 개선하기 위하여 다음과 같은 방법들을 제안한다. 우선, 미리 주어진 회전파라메타써 쌍일처 보간과 중첩 특성을 이용해서 k 공간 불균일 표본화 데이터를 수정하는 알고리즘과, 2차원 회전운동의 회전각은 이미 알려져 있고, 회전중심 위치가 미지인 경우에 대해 위상보정에 기초한 아티팩트를 보정하는 알고리즘 및 회전중심과 각도가 모두 미지인 2차원 회전운동에 대해 아티팩느를 보정하는 알고리즘을 제안한다. 이 때, 미지운동 파라메타를 예측하기 위해 찰상대상물의 경계바깥쪽에서 이상적인 MR 화상의 에너지는 최소가 되고, 활상 대상물의 회전이 존재할 때 측정된 에너지가 증가한다는 성질을 이용했다. 이러만 성질을 이용해서 시뮬레이션 화상에 적용한 결과 제안한 방법에 대한 유효성을 확인하였다.

  • PDF

Comparison of the Editing Method of Missing Area in 3D Scanned Image of Men's Crotch (3차원 스캔한 인체 샅부위의 결측부위 복원 방법 비교)

  • Kim, So-Young;Hong, Kyung-Hi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.3
    • /
    • pp.401-409
    • /
    • 2009
  • The shape of crotch area is very important to develop functional clothing as well as other ergonomic goods such as chair or saddle etc. However, it is inevitable that 3D scanned image of crotch would have missing part due to its folded shape including overlapping legs nearby. Therefore, the objectives of this research was to compare reconstruction methods of missing parts at crotch using seven dummies of real men's replicas. Two reconstruction methods adopted were kinds of 'fill- hole' in Rapidform 2004, one was 'smooth' and the other was 'curvature'. Each restored image was compared with the original shape of the dummies. As results, the average distance was 0.66mm between original and 'smooth' treated images and 0.59mm between original and 'curvature' treated, which was not statistically different. Average area of restored crotch region was $8740.04cm^2$ by 'smooth' method and $8405.02cm^2$ by 'curvature' method which is close to the original area of $8413.76cm^2$. Statistical difference was found between images of original and 'smooth' ones$(p=0.04^*)$. However, there was no difference between original and 'curvature' treated images, which indicates that 'curvature' method is more useful to fill the hole compared with 'smooth' method.