• Title/Summary/Keyword: 2유체 노즐

Search Result 142, Processing Time 0.019 seconds

Spray characteristics of twin-fluid atomization using external-mixing sonic nozzles (외부혼합형 음속노즐을 사용한 2유체 미립화의 분무특성)

  • Park, Byeong-Gyu;Lee, Jun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.1
    • /
    • pp.132-139
    • /
    • 1997
  • Spray characteristics of external mixing sonic twin-fluid atomization nozzles are investigated experimentally. Particle sizes are measured by the Fraunhofer diffraction method using the Malvern particle analyzer, and their radial distributions are obtained using the tomographical transformation technique. The spatial distribution of SMD shows that the drop size increases in the radial direction at a fixed liquid flow rate, and the distribution is getting uniform rapidly as the atomizing gas pressure increases. The SMD decreases as the liquid flow rate increases at a fixed GLR. It is found that the atomization efficiency of the flush type sonic nozzle is superior to that of protrusion type. The effect of laser beam diameter of the particle analyzer on the spatial SMD distribution is minor at present experimental conditions.

Spray Flow Characteristics of Twin-fluid Water Mist Nozzle for Fire Suppression (2유체 미세 물분무 소화노즐의 분무유동 특성)

  • Kim, Bong-Hwan;Choi, Hyo-Sung;Kim, Dong-Keon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.60-66
    • /
    • 2011
  • In the present investigation, experimental studies were conducted on the fire suppression performance of twin-fluid water mist spray which is subjected to thermal radiation in a closed space. Downward-directed water-mist sprays, interacting with an under kerosene pool fire, were investigated in a test facility. The mass mean diameter of water-mist droplets were measured by PMAS under various flow conditions. The developed twin-fluid water mit spray nozzle satisfied the criteria of NFPA 750, Class 1. The mechanism of fire suppression by fine water mist was concluded to be the cooling of the fire surface which leads to the suppression of fuel evaporation. It was proved that the automatic twin-fluid water mist spray system under lower pressures could be applied to an industrial facilities.

Prediction of Mean Diameters Based on the Instability Theory for Twin Fluid Nozzle (불안정 이론을 이용한 2유체 노즐에서의 분무입경예측)

  • Kim, Kwan-Tae;Ahn, Kook-Young;Kim, Han-Seok;Ryu, Jeong-In
    • Journal of the Korean Society of Combustion
    • /
    • v.1 no.1
    • /
    • pp.57-64
    • /
    • 1996
  • The atomizing characteristics in a spray injected from a twin fluid atomization nozzle have been investigated. The Sauter mean diameters as mean diameter are compared with wavelength calculated from the instability theory. The Sauter mean diameter are measured by the Fraunhofer diffraction theory using the Malvern particle sizer. The wavelength is calculated using the mean relative velocity instead of the exit relative velocity of nozzle. Also shadowgraphy technique is used to visualize atomization phenomena. This paper gives a possibility that the mean diameter can be predicted with the wavelength obtained by the simple instability theory.

  • PDF

Performance Evaluation of Automatic Self-Cleaning Filter System using Twin-Fluid Nozzles for Air Cleaning in the Subway Stations (지하철 공기청정을 위한 2유체노즐형 자동세정 공기청정 시스템 개발에 관한 연구)

  • Ahn, Y.C.;Lee, J.K.
    • Journal of ILASS-Korea
    • /
    • v.9 no.3
    • /
    • pp.15-21
    • /
    • 2004
  • The removal of the dusts in the subway stations, tunnels, factories and buildings becomes issue for comfortable indoor and outdoor conditions. There has been used an automatic self-cleaning filter system to collect the dusts. In general, the collected particles are removed by water spray nozzles. The new design for improving the cleaning efficiency of collected dusts and reducing the supplied water is the concept of the plane array of demister filters and the twin-fluid nozzle for mixing compressed air and water in the automatic self-cleaning filter system. Results show that the cleaning efficiency of twin-nozzle filter systems is 99.1%, compared to 47% in the conventional filter system. Therefore the automatic self-cleaning filter system using twin-fluid nozzle filter systems reduces water supplied in the filter system, and increases cleaning efficiency and drying efficiency.

  • PDF

Modeling of Nozzle Flow Inside a Y-JET Twin-Fluid Atomizer (Y-JET 2-유체 분무노즐 내부유동의 모델링)

  • In, Wang-Kee;Lee, Sang-Yong;Song, Si-Hong
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.7 s.94
    • /
    • pp.1841-1850
    • /
    • 1993
  • A simplified one-dimensional analysis has been performed to predict the local pressure distributions in Y-Jet twin-fluid atomizers. Fluid compressibility was considered both in the gas(air) and two-phase(mixing) ports. The annular-mist flow model was adopted to analyze the flow in the mixing port. A series of experiments also has been performed; the results show that the air flow rate increases and the liquid flow rate decreases with the increase of the air injection pressure and/or with the decrease of the liquid injection pressure. From the measured injection pressures and flow rates, the appropriate constants for the correlations of the pressure loss coefficients and the rate of drop entrainment were decided. The local pressures inside the nozzle by prediction reasonably agree with those by the experiments.

Analysis of the Flow of a Circular Nozzle using a slant Hot-Wire (단일 경사열선을 이용한 원형노즐의 유동해석)

  • Chung, Wui-Jun;Oh, Sang-Han
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.2
    • /
    • pp.17-23
    • /
    • 2009
  • The program using $C/C^{++}$ which could calculate 3-D velocities from data of the flowfield obtained by a slant hot-wire has been developed. The characteristic of the exit flowfield of a circular nozzle with a curved surface was investigated. From the result, the inward-flow was verified at adjacent layers near the boundary of the exit flowfield of a circular nozzle in Id and outward-flow was sensed gradually from down-flow of Id. Similarity of the nondimensional velocity profile properlly could be obtained except near Id and the virtual origin reasonably could be obtained.

Numerical Investigation of 2DCD Nozzle Flow Having a Secondary Jet Injection for Thrust Vector Control (추력벡터제어를 위한 이차 분사유동이 있는 2DCD 노즐 내부의 수치적 연구)

  • Lee JinGyu;Chang KeunShik
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.17-22
    • /
    • 2002
  • A numerical solution procedure has been developed to analyze the flow field resulted from the injection of a transverse jet through the divergent flap of a 2DCD nozzle for thrust vector control. The formulation employs the compressible Navier-Stokes equations in conservation law form and a two equation $\kappa-\omega$ turbulence model. Detailed numerical results are presented in this paper for the 2DCD nozzle over a range of secondary to primary injection mass flow ratios and nozzle pressure ratios.

  • PDF

De-Laval 노즐의 경계층 배제두께의 음수현상

  • 장태호
    • Journal of the KSME
    • /
    • v.26 no.5
    • /
    • pp.375-381
    • /
    • 1986
  • De-Laval 노즐에서 경계층 배제두께의 음수현상에 대하여 수학적 모델을 통한 수치 고찰 한 결과 배제두께 뿐만 아니라 다음과 같은 경계층의 특성을 알 수 있었다. (1)온도비($T_w/T_0$)가 작아질수록 경계층 두께가 상대적으로 커진다. (2)운동량두께의 변화도 단열 벽면이 아닌 경우에는, 비압축성(${\rho}=const$) 유체 보다. 온도비가 작을수록 항상 커진다. (3) 경계층 배제두께는 온도비가 작은 경우 음(―)의 값을 나타내고 있어, 유효유동 단면적의 확대 현상을 보이고 있다.

  • PDF

An Experimental Study on the Discharge Coefficients of Small Sonic Nozzles (소형 소닉 노즐의 유출계수에 관한 실험적 연구)

  • Cha, Tsi-Sun;Park, Kyung-Am;Choi, Yong-Moon;Choi, Hae-Man;Yoon, Bok-Hyun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.2 s.7
    • /
    • pp.44-49
    • /
    • 2000
  • Small sonic nozzles (throat diameter $0.28{\~}4.48mm$) were tested in the gas flow standard system. This standard system is composed of two bell provers and 5 column piston provers, compressor, filters, and dehumidifier. The discharge coefficients of small some nozzles are obtained and correlated as a function of throat Reynolds numbers with $0.316\%$ uncertainty at a confidence level $95\%$. The tested high Reynolds number was the lower limit of ISO 9300 specifications. The data are useful as data base for revision of ISO 9300.

  • PDF

Effects of Nozzle Diameter on Performance Characteristics for a Tangential Impeller-type Water Meter (접선류 임펠러형 수도미터의 노즐직경이 성능특성에 미치는 영향)

  • Suh, Sang-Ho;Lee, Byung-Ho;Cho, Min-Tae;Roh, Hyung-Woon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.3 s.4
    • /
    • pp.59-66
    • /
    • 1999
  • In this study the effects of nozzle diameter on the performance characteristics for the tangential impeller-type water meter are studied experimentally. The nozzle is cut along the tangential direction of the inner case in the water meter. The nozzle shape is round and the number of nozzles used for the experimental study are 8. The performance characteristics are discussed for various nozzle diameters such as 3.1, 3.3, 3.5, 4.0, 4.5 and 5.0 mm. Among the tangential impeller-type water meters, the water meter with the nozzle diameter of 5.0 mm shows the least pressure loss and the instrumental error compared to the Korean Standards.

  • PDF