• Title/Summary/Keyword: 2상 유동 마찰손실배수

Search Result 3, Processing Time 0.017 seconds

An Experimental Study on Pressure Drop of Boiling Flow within Horizontal Rectangular Channels with Small Heights (미세 수평 사각 유로 내에서의 비등 유동 압력강하에 관한 실험적 연구)

  • Lee, Sang-Yong;Lee, Han-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.9
    • /
    • pp.1219-1226
    • /
    • 2001
  • Pressure drops were measured for the flow boiling process within horizontal rectangular channels. The gap between the upper and the lower plates of each channel ranges from 0.4 to 2mm while the channel width being fixed to 20mm. Refrigerant 113 was used as the test fluid. The mass flux ranges from 50 to 200kg/㎡s and the channel walls were uniformly heated up to 15kW/㎡. The quality range covers from 0.15 to 0.75. The present experimental conditions coincide with the operating conditions of compact heat exchangers in which the liquid and gas flows are laminar and turbulent. The measured results were well represented by the two-phase frictional multiplier of Lee (2001) which has been developed for air-water two-phase flows within the deviation of $\pm$20%.

An Experimental Study on the Two-Phase Flow Pressure Drop Within Horizontal Rectangular Channels with Small Gap Heights (미세 수평 사각유로에서의 2상 유동 압력강하에 관한 실험적 연구)

  • Lee, Han Ju;Lee, Sang Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.5
    • /
    • pp.637-645
    • /
    • 1999
  • Horizontal two-phase flow pressure drop within rectangular channels with small gap heights have been examined experimentally. The gap heights range from 0.4mm to 4mm corresponding to aspect ratios(the channel height divided by the width) from 0.02 to 0.2. Water and air were used as the test fluids with the superficial velocity ranges being 0.03-2.39m/s and 0.05-18.7m/s, respectively. The experimental results In rectangular channels were compared with the Lockhart-Martinelli correlation, which are widely used for conventional round tube. The Lockhart-Martinelli correlation turned out to be Inappropriate to represent the present experimental data. In this respect, considering the aspect ratio and gap-height effects, an empirical correlation on two-phase flow pressure drop was proposed. The proposed correlation successfully covers the bubbly, plug, slug and annular flow regimes.

Pressure Drop in Microtubes and Correlation Development (마이크로관 내 압력강하 특성 및 상관식에 관한 연구)

  • Hwang, Yun-Wook;Kim, Ju-Hyok;Kim, Min-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.1
    • /
    • pp.38-46
    • /
    • 2006
  • The characteristics about the pressure drop in microtubes have been investigated. The test tubes are the circular, seamless, stainless steel tubes with an inner diameter of 0.244, 0.430, and 0.792 mm, respectively. R-l34a was used as a test fluid. Early flow transition which has been reported in some previous studies is not found in single-phase flow pressure drop tests. The conventional theory between friction factor and Reynolds number predicted the experimental friction factors within an absolute average deviation of $8.9\%$. The two-phase flow pressure drop increases for higher quality and mass flux, and for reduced inner diameter. The existing correlations fail to predict the experimental data. A new correlation to predict the two-phase flow pressure drop is developed in the form of the Lockhart-Martinelli correlation. The effects of the tube diameter and the surface tension were considered, and the correlation predicted the experimental data within an average absolute deviation of $8.1\%$.