The endodontically treated tooth is generally restored with post & core, owing to the brittleness and the loss of large amount of tooth structure. Although there have been lots of studies about the endodontically treated teeth, the three-dimensional quantitative studies about the strees distribution of them are in rare cases. In this study, it was assumed that the coronal portion of the upper incisou had severely damaged. After the root canal therapy it was post cored, and restored with PFM crown, for this experiment nine types of model were constructed : 1); long, 2); medium, 3); short gold post for the roots supported with a narmal alveolar bone, 4); long, 5); medium, 6); short gold post for the roots supported with an alveolar bone resorbed to its 1/3 of root length, 7); long, 8); medium, 9); short base metal post for the roots supported with an alveolar bone resorbed to its 1/3 of root length. Force was applied from two directions. One was functional maximum bite force(300N) applied to the spot just lingual to the incisal edge with the angle of 45 degrees to the long axis of the tooth, and the other one was horizontal force(300N) applied to the labial surface. The results analyzed with three-dimensional finite element method were as follows : 1. Stress was concentrated on the middle portion of the labial side dentin of the root and the lingual portion of the apical dentin of the root. Stress in the post showed maximum value at 2 mm above the post apex. 2. In case of the long post and base metal post, strees was concentrated on the apex of the root and the post. 3. In case of the longer post, the displacement on the post-cement interface was lessened. The gold post was more displaceable than the base metal post. 4. In case of the alveolar bone resorption, stress concentrated on the root and the post and displacement on the post-cement interface were increased.
The extent and direction of movement of removable partial dentures during function are influenced by the nature of the supporting structures and and the design of the prosthesis. Since forces are transmitted to the abutment teeth through occlusal rests, guide planes and direct retainers during functional movements, proper design based on the avaialble research data will maintain the health of abutment teeth and their supporting structures. The purpose of this in vitro study is evaluating stress distribution clinically around the abutment teeth prepared following 4-type clasping systems for unilateral free-end removable partial dentures. Three-Dimensional Photoelastic Stress Analysis method was used because it shows a visual display of stresses of the simulated abutment teeth and residual ridges and reveals stress concentration that can be read at any given points in terms of direction and magnitude. For this study, the author fabricated 4 mandibular photoelastic epoxy models missing left 1st and End molar. Epoxy models were duplicated and 4 unilateral removable partial dentures were construe- ted in accordance with 4-type direct retainers. Unilateral free-end removable partial dentures were positioned on their own models. 6kg force was loaded on the every removable partial dentures of the epoxy model on the central fossa of mandibular left 1st molar vertically by the loading device. After the stress was frozen in a stress freezing furnace, 6 specimens of 6-mm thickness were made from every epoxy model and examined with the circular polariscope. The results were as follows : 1. Generally I-bar clasp revealed the most favorable stress distribution around the abutment teeth. 2. At the end portion of the free-end ridge, Back action clasp showed the highest stress concentration at the bucco-lingual and top portions of the residual alveolar ridge. 3. At the distal area of the abutment teeth, Akers clasp and Roach clasp showed higher stress concentration bucco-lingually and apically than the others. 4. To the abutment tooth, I-bar clasp showed the least stress distribution bucco-lingually but the others showed irregular stress distribution. 5. At the mesial area of the abutment teeth, the order of effective stress distribution was I-bar clasp, Back-action clasp, Akers clasp and Roach clasp. There was big difference of stress distribution between them. 6. At the right 2nd premolar and 1st molar, the stress concentration of Akers clasp was a little high but that of I-bar clasp was low.
본 고에서는 한반도 동남권에 분포하는 주요 단층대에 대한 장기 거동 및 미소진동 관찰을 목적으로 하는 시추공 기반 심부 복합지구물리 모니터링 시스템 구축의 일환으로 수행된 대구경 시추공 굴착 현장에서 이루어진 Extended Leak-Off Test (XLOT)에 대한 내용 및 결과를 보고한다. 다양한 시추공 센서 설치를 위한 모니터링공의 굴착은 ~1 km 깊이에서 최종 구경 200 mm 이상을 확보하는 것을 목표로 하여, 중간 깊이까지 12" 구경의 시추공 굴진 및 케이싱 설치, 이후 최종 심도까지 7-7/8" 구경의 시추공을 굴진하는 것으로 설계되었다. 현장 여건에 맞추어 약 504 m 깊이까지 12" 구경의 시추공이 굴착되었으며, API 규격의 8-5/8" 케이싱을 설치하고 배면과 암반 간의 틈새(annulus)에 대한 세멘팅 작업을 수행하였다. 이후 하부 구간 굴진(7-7/8")에 앞서 세멘팅 건정성 확인 및 암반 응력 측정 등을 목적으로 XLOT를 수행하였다. 약 4 m 길이의 나공 구간(open hole)을 확보하고, 상부에 설치된 케이싱을 이용해 물을 주입하여 시험 심도의 암반을 가압하였다. XLOT 수행 과정에서 주입 유량에 따른 시험 구간 내 압력 변화 양상을 실시간 모니터링 하였으며, 이 자료들을 일부 활용하여 현장 시추공 조건에서의 암반 투수율을 해석하였다.
마찰교반접합법은 특정한 회전수로 회전하는 용접 툴을 이용하여 접합하고자 하는 피접합재의 맞댄면에 삽입시킨 후 툴을 이동시키거나 혹은 시편을 견고하게 고정시킨 장치(backing plate)가 움직여 고상 상태에서 접합이 이루어진다. 알루미늄, 마그네슘 등 비교적 융점이 낮은 저융점 재료의 재료에 처음 적용이 되어 많은 연구가 활발히 진행되었고 타 용접방법에 비해 우수한 접합특성을 나타내었다. 최근 이러한 마찰교반접합은 이러한 저융점 재료를 넘어서 스틸, 타이타늄, 니켈 등과 같은 고융점 재료 등에 대한 적용이 늘어나고 있다. 마찰교반접합을 이용하여 이러한 고융점 재료의 접합 경우 내마모성 및 내열성 등의 내구성이 갖추어진 툴과 이러한 툴을 냉각시킬 수 있는 냉각 장치 등이 필요로 하나 경제적 측면이나 접합부의 우수한 특성 등을 고려 할 때 그 적용 및 발전 가능성이 매우 높다고 볼 수 있다. 2상 스테인레스 강은 금속 조직적으로 페라이트와 오스테나이트 상이 거의 1:1의 동등한 비율로 매우 미세하게 결합된 구조를 가지고 있다. 또한 이상 스테인레스 강은 각상의 개개의 특성에 기인하여 염소 분위기에서 응력부식 저항성이 우수하고, 공식과 틈부식에 대한 저항성이 매우 뛰어나다. 그리고 이상 스테인레스 강은 비교적 고가인 Ni이 일반 오스테나이트 스테인리스 강의 약 1/2의 수준으로 적게 포함이 되어 경제적인 이점을 지니고 있으며 또한 용접성이 좋아 산업계의 수요는 현재 점차 증가하고 있는 상황이다. 하지만 이러한 이상 스테인리스 강은 용접 후 페라이트 상의 조대화, 그리고 페라이트 상의 분율이 오스테나이트 상의 분율보다 높아지게 되어 용접부에서의 저온 인성 감소 및 내식성 저하 등의 문제가 발생하게 된다. 그리하여 용접 시 이러한 문제점을 해결하기 위해서는 입열량의 조절이 가장 필요로 하는 것으로 알려져 있다. 본 연구에서는 마찰교반용접을 이용하여 두께 3mm의 대표적인 이상 스테인리스 강인 SAF2205 스테인리스 강에 대해 맞대기 마찰교반접합을 실시하였다. 툴 회전속도를 변수로 하여 접합을 실시하였으며 접합 시 툴은 $Si_3N_4$ 툴을 사용하였다. 접합 후 외관상태 점검, 미세조직 관찰, 경도 및 인장강도 측정 등의 실험을 실시하였고, 이러한 결과를 이용하여 미세조직과 기계적 특성과의 관련성을 조사하였다.
원가 측면에서 유리한 저항점용접(Resistance Spot Welding)이 차체 용접에 80%이상으로 가장 많이 적용되고 있다. 첨단고강도강(Advanced High Strength Steel)의 저항점용접성 및 용접부 특성에 미치는 공정 변수의 영향에 대한 연구결과는 많으나, 합금원소의 영향에 대해서는 전무하다. 특히, Si는 DP(Dual Phase)강에 첨가 시 균일한 마르텐사이트의 분포를 촉진하는 원소로 저항 점용접성 및 용접부 특성에 영향을 미칠 것으로 예상되며, 이에 대한 연구는 보고된바 없다. 본 연구에서는 냉연 DP강의 저항 점용접시 중요한 인자 중 하나인 너깃경과 전단인장강도에 미치는 Si함유량의 영향을 검토하였다. 사용된 강재 및 용접기는 1.2mm 두께의 Si함유량(0, 0.5, 1.0, 1.5wt%)이 다른 인장강도 780~1000MPa급 냉연 DP강과 단상 AC용접기를 사용하였다. 용접조건은 ISO 18278-2규격에 따라 가압력 4kA, 초기가압시간 40cycle, 유지시간 17cycle로 고정하고, 용접전류만 변화하여 용접을 실시하였다. 너깃경은 용접부 단면을 컷팅 후 폴리싱 하여, 광학현미경과 Image Pro plus를 이용하여 측정했으며, 인장시편규격은 JIS Z 3137를 이용하였다. Si함유량이 증가에 따라 스패터 발생 전류는 감소했고, 너깃경은 직선적으로 증가했다. Si함유량 증가에 따른 너깃경 증가 이유는 저항(R) 측정결과, Si함유량 증가에 따라 모재의 저항이 높아져, 따라서 입열량($Q=I^2Rt$)이 많아지기 때문으로 판단되었다. 인정전단강도는 Si함유량 증가에 따라 직선적으로 증가했다. 이러한 이유는 Si함유량 증가에 따라 너깃경이 증가되기 때문으로 판단되었고, 너깃경과 인장전단강도 사이에 직선적 관계(PL(kN)=$3.2N_{dia.}$-0.81, $R^2$=0.93)를 가지고 있었다. 파단양상은 Si함유량에 상관없이 5.4kA이하에서는 계면파단이 일어났고, 6.0kA이상에서는 풀 아웃 파단이 일어났다. 계면파단주원인은 용접부 가장자리에 지름이 약 $5{\mu}m$이하의 예리한 노치가 존재하여 노치응력집중과 HAZ계면 근처에 미접합부가 존재하기 때문으로 판단되었다. 6.0kA이상에서는 예리한 노치가 없었고, HAZ부가 완전히 접합되어 있기 때문에 풀 아웃 파단이 일어난 것으로 판단되었다. 따라서, Si함유량 증가에 따라 적정용접전류 구간은 감소했고, 너깃경은 직선적으로 증가했다. 또한, Si함유량 증가에 따라 인장전간강도는 증가 했으며, 너깃경과 인장전단강도 사이에 직선적 관계를 가지고 있었다. 파단 양상은 Si함유량에 상관없이 5.2kA이하에서는 계면파단이, 6.0kA이상에서는 풀 아웃 파단이 일어났다.
Statement of problem. The implant prosthesis has been utilized in various clinical cases thanks to its increase in scientific effective application. The relevant implant therapy should have the high success rate in osseointegration, and the implant prosthesis should last for a long period of time without failure. Resorption of the peri-implant alveolar bone is the most frequent and serious problem in implant prosthesis. Excessive concentration of stress from the occlusal force and biopressure around the implant has been known to be the main cause of the bone destruction. Therefore, to decide the location and angulation of the implant is one of the major considering factors for the stress around the implant fixture to be dispersed in the limit of bio-capacity of load support for the successful and long-lasting clinical result. Yet, the detailed mechanism of this phenomenon is not well understood. To some extent, this is related to the paucity of basic science research. Purpose. The purpose of this study is to perform the stress analysis of the implant prosthesis in the partially edentulous mandible according to the different nature locations and angulations using three dimensional finite element method. Material and methods, Three 3.75mm standard implants were placed in the area of first and second bicuspids, and first molar in the mandible Thereafter, implant prostheses were fabricated using UCLA abutments. Five experimental groups were designed as follows : 1) straight placement of three implants, 2) 5$^{\circ}$ buccal and lingual angulation of straightly aligned three implants, 3) 10$^{\circ}$ buccal and lingual angulation of straightly aligned three implants. 4) lingual offset placement of three implants, and 5) buccal offset placement of three implants. Average occlusal force with a variation of perpendicular and 30$^{\circ}$ angulation was applied on the buccal cusp of each implant prosthesis, followed by the measurement of alteration and amount of stress on each configurational implant part and peri-implant bio-structures. The results of this study are extracted from the comparison between the distribution of Von mises stress and the maximum Von mises stress using three dimensional finite element stress analysis for each experimental group. Conclusion. The conclusions were as follows : 1. Providing angulations of the fixture did not help in stress dispersion in the restoration of partially edentulous mandible. 2. It is beneficial to place the fixture in a straight vertical direction, since bio-pressure in the peri-implant bone increases when the fixture is implanted in an angle. 3. It is important to select an appropriate prosthodontic material that prevents fractures, since the bio-pressure is concentrated on the prosthodontic structures when the fixture is implanted in an angle. 4. Offset placement of the fixtures is effective in stress dispersion in the restoration of partially edentulous mandible.
본 연구는 열적 및 기계적 피로응력이 교정용 브라켓의 전단결합강도, 인장결합강도, 전단-인장 복합 결합강도에 미치는 영향과 결합상태에 미치는 영향, 그리고 접착파절 양상을 비교하는데 목적이 있다. 이를 위하여 기저부 형태가 다른 5종의 금속 브라켓을 교정치료를 목적으로 발거한 상$\cdot$하악 소구치에 부착하여, 계면에 200g의 전단-인장 복합 하중을 4주간 가한 기계적 피로시험과, 5,000회의 thermocycling을 시행한 열적 피로시험 후, 전단결합강도, 인장결합강도, 및 전단-인장 복합 결합강도를 측정하고, 파절양상을 분석하여 다음과 같은 결과를 얻었다. 1. 정적시험에서 얻은 브라켓 접착부의 결합강도는 Photoetched base가 가장 크고, Integral base가 가장 작았다(p<0.05). 모든 종류의 브라켓에서 전단결합강도가 가장 컸으며, 전단-인장 복합 결합강도는 전단결합강도의 1/3 수준으로 가장 작았다. 2. 4주간 200g의 전단-인장 복합 하중을 가한 후의 결합강도는 Photoetched base가 가장 크고, Integral base가 가장 작았으며 (p<0.05), 기계적 피로시험 후 Photoetched base와 Micro-Etched Foil Mesh base의 전단, 인장, 전단-인장 복합 결합강도가 감소하였고, Chessboard base의 전단결합강도가 감소하였다(p<0.05). 3. 5,000회의 thermocycling 후의 결합강도는 Photoetched base가 가장 컸고, integral base가 가장 작았으며(p<0.05), 열적 피로시험 후 Photoetched base와 Chessboard base, Micro-Etched Foil Mesh base의 결합강도가 모두 감소하였다(p<0.05). 4. 정적시험의 결합강도 측정 후 접착파절은 브라켓/레진 계면에서 일어났으며, thermocycling 후에는 브라켓/레진 계면과, 법랑질/레진 계면, 레진내 파절이 혼합되어 나타나 ARI 점수가 높아졌다. 기계적 피로시험 후에는 정적시험 때와 비슷한 ARI 점수를 보였다. 5. 모든 브라켓에서 thermocycling 후 브라켓/레진 계면과 법랑질/레진 계면에서 미세 균열이 관찰되었다.
이 논문은 현재에 통용되고 있는 동합금판 C2200, C5210, C7701, C8113 등의 특징 및 용도와 소재의 재질적 특성을 data화하였고, 그 표현의 가능성을 조사하여 수치화하였고, 그 기법실험의 1단계로서 일반접합과 TIG 접합에 대하여, 2단계 실험으로서 망상조직기법과 전해주조기법에 대하여 농하였으며, 이 기법을 응용한, 연구작품의 3가지 사례를 다루었다. 이 때 사용한 동합금은 (주)풍산금속 소재기술연구소 이동우 박사가 지원한 4가지 동합금, 즉 단동, 스프링용 인청동, 스프링용 양백, 백동을 사용하여, 적층기법, 망상조직기법, 융합기법, 전해주조기법을 작품에 따라서 통합 또는 부분적으로 적용시켰다. C2200 의 경우, 황동은 2mm이하의 박판(薄板)에서는 교류 TIG 용접법이 좋으며 그 이상에서는 직류 정극성 TIG 용접법으로, 용접에 의한 잔류 응력부식을 열처리를 250~300도에서 행한다. C5210 의 경우는 고온의 환원성기(還元性氣)중에서도 수소(水素) 취성이 없고 고온에서 O를 흡수하지 않으며, 경화(輕化) 온도도 약간 높아, 용접용으로 매우 적합하다. 일반적으로 Sn을 2-9% P를 0.03-0.4%정도 포함하고 있는데, Sn의 함유량이 증가함에 따라 응고 온도 범위가 광범위해졌으며 용접후의 냉각 시, 열분열 방지에는 TIG용접의 용접속도를 빠르게, 용융지(溶融池)를 작게, 예열 온도는 200도로 하는 것이 좋다. C7701의 경우는 조성범위가 10-20% Ni, 15-30% Zn의 것이 많이 사용된다. 약 30% Zn 이상이 되면(${\alpha}+{\beta}$) 조직이 되어 점성이 낮아지고 냉간 가공성은 저하하나 열간 가공성은 좋다. 양백은 또한 전기저항이 높고 내열, 내식성이 좋다. C8113의 경우는 내해수성, 내마모성이 우수하며 고온 강도가 높고 백동은 10-30% 니켈을 포함하며 완전히 고용(固溶)해서 단상(單相)이 된다. 이 때문에 결정입(結晶粒)도 크게 되기 쉬우며, 구속이 강한 경우 미량의 Pb, P, S라는 분열 감수성이 높아진다.
엔진 설계시 실린더 주요 부품의 온도 분포 계산은 엔진 전체 구조안정성 평가시 열응력에 의한 변형을 고려하기 위해 필수적으로 수행된다. 최근 박용 및 발전용 중속엔진은 압축비 및 출력이 증대 되어 설계되고 있는 추세여서 증가된 연소실 열부하에 의한 영향을 고려하기 위해 열전달 해석의 높은 정확도가 요구되고 있다. 본 연구에서는 엔진 설계시 실린더 주요 부품의 온도 분포를 계산하고 계산된 온도 수준이 설계기준에 만족하는지를 정확히 평가 하기 위한 열전달 해석 프로세스를 정립하였다. 각 주요 열부하 영역의 경계조건 설정 과정을 1 차원 엔진 성능해석 및 3 차원 열유동 해석을 통하여 산출하여 적용하였으며 해석 결과는 해당엔진 모델의 프로토 타입엔진 주요 부품 온도를 계측하여 검증하였다.
분무주조법으로 제조된 Al-25Si-(Fe,V) 합금빌렛의 미세조직을 광학현미경, 주사전자현미경, 투과전자현미경으로 분석하였으며, 빌렛내에서 관찰되는 2차상의 형성거동을 정확히 분석하기 위해 over-sprayed 분말의 미세조직을 분무주조 빌렛과 함께 관찰하였다. 먼저 분무주조 빌렛을 표면으로부터 중심부까지 관찰한 결과, 분무주조 빌렛의 미세조직은 표면부 10mm 가량을 제외하고는 매우 균일한 미세조직을 보여주었다. 이에 본 연구에서는 분무주조 빌렛의 표면부와 중심부, 그리고 over-sprayed 분말조직으로 구분하여 각각에서 관찰되는 2차상을 관찰하였으며, 이를 바탕으로 분무주조 빌렛내에 형성된 2차상의 형성기구를 규명하고자 하였다. Over-sprayed 분말의 미세조직은 기지조직내에 균일하게 분포된 침상의 $\delta$-AlFeSi 상과 각형의 Si 입자로 구성되어 있었다. 반면, 분무주조 빌렛의 경우, 그 중심부에서는 기자조직내에 균일하게 분포된 막대형의 $\beta$-AlFeSi과 부정형의 조대한 Si입자가 관찰되었으며, 표면부에서는 부정형의 Si 입자와 함께 막대형의 $\beta$-AlFeSi/$\delta$-AlFeSi 복합상이 관찰되었다. 특히, 빌렛 표면부의 $\beta$-AlFeSi 상과 $\delta$-AlFeSi 상간에는 일정한 방위관계가 존재하였으며, 이러한 결과는 분무주조 빌렛내에 분포된 $\beta$-AlFeSi상들이 분무액적내에 형성된 준안정 $\delta$-AlFeSi 상으로부터 상분해되어 형성되었음을 제시한다. 이상의 분무주조 조직과 over-sprayed 분말의 미세조직으로부터 분무주조 빌렛의 최종 주조조직은 반응고상태의 분무액적 조직에 의해 지배됨을 알 수 있다.r plate)의 단면 미세조직 사진으로써 모재부와 오버레이충을 함께 보여주고 있다. 모재와 오버레이 충간의 경계면은 모재 일부가 용융된 후 웅고하면서 형성됨으로 인해서 도금이나 용사층과는 달리 매우 견고하게 결합되어 있다. 따라서 계면부의 탈락이라는 문 제점은 거의 없어 심한 응력을 받는 기계구조물 및 부품에도 본 기술은 널리 적용되고 있다. 그리고 사진 1에서 알 수 있는 바와 같이 모재와는 전혀 상이한 재료를 자유로이 선택하여 표면 유효층 일부만 오버레이시키며I 주조 및 단조가 불가능한 재료까지도 표면부에 오버레이 시킴으로 서 부품 및 설비의 제조에 있어 재료비의 절감과 제품의 수명이 획기적으로 개선될 수 있다. 그리고 최근에는 도금 빛 용사 둥과 같은 표면처리를 할 경우임의 소재 표면에 도금 및 용 사에 용이한 재료를 오버레이용접시킨 후 표면처리를 함으로써 보다 고품질의 표면층을 얻기위한 시도가 이루어지고 있다. 따라서 국내, 외의 오버레이 용접기술의 적용현황 및 대표적인 적용사례, 오버레이 용접기술 및 용접재료의 개발현황 둥을 중심으로 살펴봄으로서 아직 국내에서는 널리 알려지지 않은 본 기 술의 활용을 넓이고자 한다. within minimum time from beginning of the shutdown.및 12.36%, $101{\sim}200$일의 경우 12.78% 및 12.44%, 201일 이상의 경우 13.17% 및 11.30%로 201일 이상의 유기의 경우에만 대조구와 삭제 구간에 유의적인(p<0.05) 차이를 나타내었다.는 담수(淡水)에서 10%o의 해수(海水)로 이주된지 14일(日) 이후에 신장(腎臟)에서 수축된 것으로 나타났다. 30%o의 해수(海水)에 적응(適應)된 틸라피아의 평균 신사구체(腎絲球體)의 면적은 담수(淡水)에 적응된 개체의 면적보다 유의성있게 나타났다. 해수(海水)에 적응(適應)된 틸라피아의 신단위(腎單位)의 사
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.