• 제목/요약/키워드: 1D column test

검색결과 154건 처리시간 0.029초

고강도 철근 및 고강도 콘크리트를 사용한 보-기둥 접합의 비선형 거동 (Inelastic Behavior of High Strength Reinforced Concrete Beam-Column Joint)

  • 이정한;조중현;유영찬;이원호;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.547-552
    • /
    • 1999
  • The purpose of this study is to make a contribution to the construction of 40∼60 story R/C high rise building by developing the reinforcing details which can improve the seismic performance of high-strength (f'c=700㎏/㎠, fy=4000, 8000㎏/㎠) R/C beam-column joints. The reinforcing details which can make beam plastic hinging zones moved and spreaded from the column face is proposed to insure the ductile behavior of high-strength RC beam-column joints. The intermediate reinforcement which is vertically anchored by interlinking each intermediate reinforcements is proposed and tested to examine the mechanical performance of proposed details. Main variables are the shape of the intermediate reinforcements and yield strength of rebars. From the test results, the newly proposed intermediate reinforcement details can move and spread the beam plastic hinging zone about 1.0d from the column face.

  • PDF

2차원 여분 메모리를 이용한 내장메모리의 자가치유회로 설계 (Design of Built-In-Self-Repair Circuit for Embedded Memory Using 2-D Spare Memory)

  • 최호용;서정일;차상록
    • 대한전자공학회논문지SD
    • /
    • 제44권12호
    • /
    • pp.54-60
    • /
    • 2007
  • 본 논문에서는 내장메모리의 고장을 효율적으로 치유하기 위해 2차원의 여분 메모리를 이용한 내장메모리의 자가치유회로를 제안한다. 내장메모리에 같은 행(열)에 다수의 고장이 발생할 경우에 기존의 1차원의 여분 열(행) 메모리를 이용할 경우에는 고장 수만큼의 여분 메모리 열(행)이 필요하나. 2차원의 메모리를 사용하는 본 방법에서는 하나의 여분 메모리 행(열)으로 치유가 가능하다. 또한, 가상분할 메모리방식을 이용함으로써 여분 메모리 열 전체가 아니라 부분 열을 이용하여 치유가 가능하다. 본 구조를 이용하여, $64\times1$ bit의 코어메모리와 $2\times8$의 2차원 여분 메모리로 구성된 자가치유회로를 설계한다. 그리고, 고장검출을 위해서 13N March 알고리즘을 가진 자가테스트회로를 내장한다. 매그너칩 $0.25{\mu}m$ CMOS공정을 이용하여 Full-Custom으로 설계한 결과, 10,658개의 Tr.수에 코어면적은 $1.1\times0.7mm^2$이 소요되었다.

세립분의 함유량이 Sand Column의 투수성에 미치는 영향 (The Effects of Fines on the Permeability in Sand Column)

  • 이진수;장용채
    • 한국항해항만학회지
    • /
    • 제29권3호
    • /
    • pp.263-268
    • /
    • 2005
  • 세립분의 함유량, 구속압력과 건조밀도에 따른 Sand Column의 투수성에 대한 시험을 실시하였다. 삼축투수시험은 세립분의 함유량 (5, 15, 25, $35{\%}$), 구속압력($\sigma_3^'=0.5,\;1.0,\;2.0,\;3.0{\cal}kg/{\cal}cm^2$)과 건조밀도($\gamma_d=1.50,\;1.55,\;1.60,\;1.65 {\cal}g/{\cal}cm^3$)를 달리한 여러 종류의 시료에 대하여 수행되었다. 삼축투수시험 결과 세립분 함유량, 구속압력 및 건조밀도가 커질수록 투수계수는 작아지는 것을 알 수 있었다. 특히, 세립분의 함유량에서는 $0.01{\cal}mm$ 입경 이하의 세립분이 증가할수록 투수성이 매우 크게 감소하고, 구속압력과 건조밀도에서는 낮은 구속압력수준 ($\sigma_3^'=0.5{\~}1.0{\cal}kg/{\cal}cm^2$)과 낮은 수준의 밀도($\gamma_d=1.50{\~}1.55{\cal}g/{\cal}cm^3$) 변화에서 투수성의 감소가 매우 크게 일어남을 알 수 있었다.

래티스형 철근을 이용한 무량판 구조의 접합부 전단보강 (Shear Reinforcement for Flat Plate-Column Connections using Lattice Bars)

  • 안경수;박홍근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.587-590
    • /
    • 2003
  • In flat-plate floors, slab-column connections are broken down with a brittle shear failure. And it can cause the collapse of the whole structures. Thus, the proper method of shear reinforcement in flat plate-column connections must be required. The objective of this study is to compare shear reinforcement specimens using lattice bars to no shear reinforcement specimens in view of shear strength and ductility of the flat plate-column connections. The test results have shown that shear reinforcement specimens varying $\rho$, $b_0$/d and $C_1$/$C_2$ increase in shear strength by 36.85% and in ductility by 9.16 for no shear reinforcement specimens on the average. This results confirm the effectiveness of this type of shear reinforcement in improving shear strength and ductility.

  • PDF

Experimental study on seismic behavior of frame structures composed of concrete encased columns with L-shaped steel section and steel beams

  • Zeng, Lei;Ren, Wenting;Zou, Zhengtao;Chen, Yiguang;Xie, Wei;Li, Xianjie
    • Earthquakes and Structures
    • /
    • 제16권1호
    • /
    • pp.97-107
    • /
    • 2019
  • The frame structures investigated in this paper is composed of Concrete encased columns with L-shaped steel section and steel beams. The seismic behavior of this structural system is studied through experimental and numerical studies. A 2-bay, 3-story and 1/3 scaled frame specimen is tested under constant axial loading and cyclic lateral loading applied on the column top. The load-displacement hysteretic loops, ductility, energy dissipation, stiffness and strength degradation are investigated. A typical failure mode is observed in the test, and the experimental results show that this type of framed structure exhibit a high strength with good ductility and energy dissipation capacity. Furthermore, finite element analysis software Perform-3D was conducted to simulate the behavior of the frame. The calculating results agreed with the test ones well. Further analysis is conducted to investigate the effects of parameters including concrete strength, column axial compressive force and steel ratio on the seismic performance indexes, such as the elastic stiffness, the maximum strength, the ductility coefficient, the strength and stiffness degradation, and the equivalent viscous damping ratio. It can be concluded that with the axial compression ratio increasing, the load carrying capacity and ductility decreased. The load carrying capacity and ductility increased when increasing the steel ratio. Increasing the concrete grade can improve the ultimate bearing capacity of the structure, but the ductility of structure decreases slightly.

비내진 상세를 가진 1/3 축소 R.C. 외부 접합부의 반복 횡하중 실험 (Cyclic-loading Tests of 113-Scale R.C. Exterior Beam-column Joints With Non-Seismic Detailing)

  • 이한선;차병기;고동우;임동운
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.179-184
    • /
    • 2001
  • The objective of this study is to clarify the seismic capacity and the characteristics in the hysteretic behavior of RC structures with nonseismic detailing. To do this, an exterior beam-column subassemblage was selected from a 10-story RC building and 6 1/3-scale specimens were manufactured with 3 variables; ⑴ with and without slab, ⑵ upward and downward direction of anchorage for the bottom bar in beams, and ⑶ with and without hoop bars in the joint region. The test results have shown that ⑴ the existence of slab increased the strength in positive and negative moment, 25% and 62%, respectively; ⑵ the Korean practice of anchorage (downward and 25 $d_{b}$ anchorage length) caused the 8% reduction of strength and the early strength degradation when compared with the case of seismic details; and ⑶ the existence of hoop bars in the joint region does not show significant difference because the size of column is much larger than that of beam.m.

  • PDF

고강도 콘크리트를 사용한 보-기둥 접합부의 비 선형 거동에 관한 기초적 연구 (A Fundmental Study of the Inlastic Behavior of High Strength Concrete Beam-Column Joints.)

  • 민정규;박현수;정란
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1990년도 가을 학술발표회 논문집
    • /
    • pp.51-56
    • /
    • 1990
  • Six small-scale reinforced concrete beam-column joint specimens subjected to monotonic and cyclic loading were tested to investigate the effects of strength of concrete. Variables are 1)compressive strength of concrete(f' c=300, 700kg/㎠), 2)shear span to depth ratio (a/d=4.7, 2.0). The major results of this test were: 1)flexural strength of high strength concrete beam-column joint was not affected too much by the compressive strength of concrete, 2) flexural cracks emerge to inside of beam deeply for high strength concrete member.

  • PDF

인증표준물질(Certified reference materials, CRM)을 이용한 이옥신류(PCDDs/PCDFs) 측정의 정확도 평가 (Evaluation of accuracy for measurement of Dioxins (PCDDs/PCDFs) by using certified reference material (CRM))

  • 윤여영;박덕희;임영희;조혜성
    • 분석과학
    • /
    • 제22권5호
    • /
    • pp.376-385
    • /
    • 2009
  • 본 연구에서는 고농도 PCBs (Polychlorinated biphenyls)로 오염된 토양류 인증표준물질(Certified reference materials, CRM) 내에 존재하는 17종의 PCDDs/PCDFs를 분석하여 측정의 정확도를 평가하였다. 분석 방법은 2007년 환경부에서 고시한 비의도적 잔류성유기오염물질 공정시험방법을 토대로 하였으나 다층 실리카겔 컬럼과 알루미나 컬럼으로만 정제 시 방해 물질들이 충분히 제거되지 않아 활성탄 컬럼을 추가하여 정제하였다. 정확도의 평가 지표로서는 한국표준과학연구원(KRISS)에서 제시한 |En| 값을 사용하였으며 |En|값이 1이하인 경우 정량 결과를 '만족'으로 판정한다. 본 실험에서 DB-5MS컬럼과 SP-2331 컬럼을 병용하여 CRM을 분석한 결과 17종 2,3,7,8-치환이성체 모두 1 이하의 |En| 값을 얻었다. 또한 DB-5MS 컬럼에서 분리되지 않는 1,2,3,7,8-PeCDD와 3,3',4,4',5,5'-HxCB는 선택 이온비를 EPA1613 방법에서 제시한 M+2/M+4 대신 M/M+2로 변경하여 HRGC/HRMS 분석에서 구분이 가능하도록 하였다.

20db 정착길이를 가지는 SD700 갈고리철근과 확대머리철근의 정착성능 실험 (Anchorage performance tests of SD700 hooked bar and headed bar with a anchorage length of 20db)

  • 김호영;심혜정
    • 도시과학
    • /
    • 제7권2호
    • /
    • pp.21-27
    • /
    • 2018
  • With the increase of the skyscraper center, the development of large-diameter and high-strength reinforcing bars is being carried out to solve the dense reinforcement. In case of the steel reinforced concrete with a small cross section such as beam-column joints, the development length becomes short when straight bars are used. Therefore, it is possible to solve the problem that the development length becomes short by using the bearing strength of the hooked bar and headed bar. In this study, the exterior beam-column joint test of SD700 hooked bar and headed bar with anchorage length of 20db was conducted to extend the development length limitation of hooked bar and headed bar. As a result of the evaluation of the anchorage strength using the design equation by KCI, the average of the [measured value]/[predicted value] ratio was 1.31 for the hooked reinforcing bars. In the case of headed bars, the average of the [measured value]/[predicted value] ratio was 1.12. In addition, in order to compare the anchorage performance of the hooked bar and the headed bar, the measured values were divided by the square root of the compressive strength of the concrete to compare the anchorage strength. Under the same conditions, the anchorage strength of headed bars was 8.5% higher than the hooked bars.

생물활성탄을 이용한 Linear Alkyl Sulfate함유 원수에서의 질산화에 관한 연구 (A Study on Nitrification of Raw Waters Containing Linear Alkyl Sulfate in Biological Activated Carbon)

  • 박성순;장지수;유명진
    • 상하수도학회지
    • /
    • 제9권3호
    • /
    • pp.116-126
    • /
    • 1995
  • The purpose of this study was to investigate the removal of ammonium nitrogen by biological nitrification in raw water containing LAS using BAC. At batch teats, LAS removal by ozone followed the first order reaction, and the rate constants(k) by ozone dose 1, 3mg/min.L were $0.040min^{-1}$, $0.062min^{-1}$ respectively. Therefore, the more ozone was dosed, the higher LAS was removed The reaction between ozone and ammonium nitrogen also followed the first order, and rate constants(k) at pH7,8 and 9 were $8.9{\times}10^{-4}min-1$, $3.8{\times}10^{-3}min^{-1}$, and $2.9{\times}10^{-2}min^{-1}$ respectively at ozone dose of 3mg/min.L . Therefore, ammonium nitrogen was little removed by ozone under neutral pH of 7. The continuous flow apparatus had four sets composed of a ozone contacter and a GAC column. Through continuous filtration test for 50days, the following conclusions were derived; (1) LAS was removed 23%, 30% respectively by ozone dose 1, 3mg/L, and was not detected in all column effluents during the period of experiment. Therefore, it appeared that adsorption capacities of each column still remained. (2) Ammonium nitrogen concentration after ozone contact varied little in raw Water because pH of raw water was from 6 to 7, and was transfered to nitrite and nitrate within GAC columns as the result of staged nitrification. After 30days, nitrite was not detected in all column effluents due to biological equilbrium between nitro semonas and nitrobacter Average removals of ammonium nitrogen in each column after the lapse of 30days were the following; ${\cdot}$ column A (ozone dose 3mg/L, EBCT 9.5min): about 100% ${\cdot}$ column B (ozone dose 1mg/L, EBCT 9.5min): 91% ${\cdot}$ column C (ozone dose 3mg/L, EBCT 14.2min): about 100% ${\cdot}$ column D (ozone dose 0mg/L, EBCT 9.5min): 53% Though column A and C reached nitrification of about 100%, column C (longer EBCT than column A) was more stable than column A. (3) After backwash, nitrification reached steady state within 5 to 8 hours. Therefore, nitrification was not greatly affected by backwash. (4) According to the nitrification capacity in depth of column A, C, where 100% nitrification occured. LAS was removed within 20cm, while ammonium nitrogen required more depth to be removed by nitrification.

  • PDF