• Title/Summary/Keyword: 1Cr-1Mo-0.25V 강

Search Result 24, Processing Time 0.019 seconds

Spherical Indentation Testing to Evaluate Mechanical Properties In 1Cr-1Mo-0.25V Steel (Spherical Indentation Testing에 의한 1Cr-1Mo-0.25V 강의 기계적 물성 평가)

  • Lee, J.M.;Nam, Y.H.;Nham, S.H.;Lee, S.S.;Lee, O.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.266-271
    • /
    • 2001
  • Spherical indentation technique was developed to evaluate the flow properties of metallic materials in carbon steel, stainless steel and alloys, etc. Through the spherical indentation test, differently degraded 1Cr-1Mo-0.25V steel's mechanical properties were observed and compared with conventional standard test data. The flow properties of 1Cr-1Mo-0.25V steels were estimated by analyzing the indentation load-depth curve. To characterize the flow property, we used material yield slope and constraint factor index rather than strain-hardening exponent because the variation of strain-hardening exponent was very little and the data showed irregularly. And the constraint factor's effect was small when the material yield slope was taken into account.

  • PDF

Normalization of DBTT Size Effect far Aged 1Cr-lMo-0.25V Steel (열화된 1Cr-1Mo-0.25V강의 DBTT 크기효과 보정에 관한 연구)

  • Nam, Seung-Hun;Kim, Eom-Gi;Lee, Dae-Yeol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.12
    • /
    • pp.2109-2115
    • /
    • 2001
  • Miniaturized specimen technology is useful to characterize the mechanical behavior when it is difficult to sample the material enough for the test. In this study, two kinds of miniaturized Charpy impact specimens(i.e., miniaturized specimen with side groove and without side groove) of aged 1Cr- lMo-0.25V steel were prepared and tested. The relationship between the extent of degradation in terms of ductile brittle transition temperature(DBTT) and the fracture stress of 1Cr-1Mo-0.25V steel was established. The fracture stress obtained from miniaturized specimen without side groove turned out to be linearly related with the DBTT of standard specimen. Therefore the fracture toughness of aged turbine rotor steel might be evaluated by the fracture stress. In addition, the correlation between DBTT of standard specimen and that of miniaturized specimen was investigated. As the results of normalizing DBTT by maximum elastic tensile stress, the normalized DBTT of miniaturized specimen without side groove allows one to estimate that of standard specimen.

Degradation Evaluation of 1Cr-lMo-0.25V Steel by Measuring Reversible Magnetic Permeability (가역 투자율 측정에 의한 1Cr-1Mo-0.25V 강의 열화도 평가)

  • Ryu, Kwon-Sang;Kim, Yong-Il;Nahm, Seung-Hoon;Yu, Kwang-Min;Cho, Youk;Son, De-Rac
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.5
    • /
    • pp.445-450
    • /
    • 2000
  • The integrity of the turbine rotors can be assessed by measuring reversible permeability and Vickers hardness of the aged rotors at service temperature. The measurement system of reversible permeability, which measured by applied alternating perturbing magnetic field, was constructed in order to evaluate material degradation, nondestructively. The test specimen was 1Cr-1Mo-0.25V steel used widely for turbine rotor material, and the specimens were prepared by the isothermal heat treatment at $630\;^{\circ}C$. The reversible permeability of the test materials were measured at room temperature. The peak interval of reversible permeability and Vickers hardness decreased with the increase of degradation. The degradation of test material may be determined nondestructively by the lineality of Vickers hardness and the peak interval of reversible permeability.

  • PDF

A Study on the Evaluation of Material Degradation of 1Cr-lMo-0.25V Steel using Ultrasonic Techniques (초음파법을 이용한 1Cr-lMo-0.25V강의 열화도 평가에 관한 연구)

  • Kim, Jeong-Pyo;Seok, Chang-Seong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.12
    • /
    • pp.2116-2124
    • /
    • 2001
  • It's required mechanical properties of in-service facilities to maintain safety operation in power plants as well as chemical plants. In this studdy the four classes of the thermally aged 1Cr-lMo-0.25V specimens were prepared using an artificially accelerated aging method at 630$\^{C}$. Ultrasonic tests, tensile tests, K$\_$IC/ tests and hardness tests were performed in order to evaluate the degree of degradation of the material. The mechanical properties were decreased as degraded, but the attenuation coefficient and the harmonic generation level of a ultrasonic signal were increased. Expecially the nonlinear parameter derived from the harmonic generation level is sensitive and will be a good parameter to evaluate the material degradation.

Degradation Evaluation of Aged 1Cr-1Mo-0.25V Steel Using Coercive Force (보자력을 이용한 1Cr-1Mo-0.25V강 인공시효재의 열화도 평가)

  • Ryu, K.S.;Nahm, S.H.;Kim, Y.I.;Yu, K.M.;Son, D.R.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.4
    • /
    • pp.288-293
    • /
    • 1999
  • The integrity of the turbine rotors can be assessed by the coercive force and Vickers hardness of the aged rotors at service temperature. The coercive force measurement system was constructed in order to evaluate material degradation nondestructively. The test specimen was 1Cr-1Mo-0.25V steel used widely for turbine rotor material, and then the seven kinds of specimens with different degradation levels were prepared by the isothermal heat treatment at $630^{\circ}C$. The coercive force of the test materials was measured at room temperature. Vickers hardness and coercive force decreased with the increase of degradation. The relationship between Vickers hardness and coercive force was investigated. The degradation of test material may be determined nondestructively by the relationship between Vickers hardness and coercive force.

  • PDF

Evaluation of J$_lc$ and T$_mat$ of aged 1Cr-1Mo-0.25V steel at elevated temperature (시효열화시킨 1Cr-1Mo-0.25V 강의 고온에서의 J$_lc$ 및 T$_mat$ 의 평가)

  • 윤기봉;윤석호;서창민;남승훈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.11
    • /
    • pp.2860-2870
    • /
    • 1994
  • When crack are detected in aged turbine rotors of power plants, information on fracture resistance of the aged material at operating temperature is needed for determination of critical loading condition and residual life of the turbine. In this study, fracture toughness (J$_lc$) and tearing modulus(T$_mat$) of virgin and thermally degraded 1Cr-1Mo-0.25V steel, which is one of the most widely used rotor steels, were measured at 538.deg. C according to ASTM E813 and ASTM E1152, respectively. Five kinds of specimen with different degradation levels were prepared by isothermal aging heat treatment at $630^{\circ}C.$ It was observed that J$_lc$ and T$_mat$ value decreased as the degradation level increased. Analysis of microstructures using a scanning electron microscope showed that the decrement of J$_lc$ is related to segregation of impurities at grain boundaries. It was also verified that the DC electric potential drop method is accurate and reliable for crack length monitoring at elevated temperature.

Spherical Indentation Testing to Evaluate Mechanical Properties in 1Cr-1Mo-0.25V Steel (구형압입시험에 의한 1Cr-1Mo-O.25V강의 기계적 물성 평가)

  • Lee, Jong-Min;Lee, Seung-Seok;Lee, Ouk-Sub;Nam, Young-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.516-522
    • /
    • 2002
  • For the experimental study of rotor steel, seven kind of specimens with different degradation levels were prepared by isothermal heat treatment at $630^{\circ}C$. Spherical indentation technique was developed to evaluate the flow properties of metallic materials in carbon steel, stainless steel, and alloys, etc. Through the spherical indentation test, differently degraded 1Cr-1Mo-0.25V steel's mechanical properties were observed and compared with conventional standard test data. The flow properties of 1Cr-1Mo-0.25V steel's were estimated by analyzing the indentation load-depth curve. To characterize the flow property, we used material yield slope and constraint factor index rather than strain-hardening exponent because the variation of strain-hardening exponent was very little and the data showed irregularly. And the constraint factor's effect was small when the material yield slope was taken into account.

Evaluation of Material Degradation of 1Cr-1Mo-0.25V Turbine Casing Steel Aged Artificially by Isothermal Heat Treatment (등온열처리법에 의해 모의 열화된 1Cr-1Mo-0.25V 터빈케이싱 강의 재질열화 평가)

  • Ma, Young-Wha;Kim, Do-Hyung;Yoon, Kee-Bong
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.1
    • /
    • pp.22-26
    • /
    • 2010
  • Material degradation should be considered to assess integrity and residual life of high temperature equipments. However, the property data reflecting degradation are not sufficient for practical use. In this study, mechanical properties of 1Cr-1Mo-0.25V casting steel generally used for turbine casing were measured and variation of microstructure was observed. Degradation was simulated by isothermal heat treatment.

Evaluation Technology of Degradation of Metallic Alloy using Electrical Resistivity (전기비저항을 이용한 금속합금 열화도 평가기술)

  • Nahm, Seung-Hoon;Yu, Kwang-Min;Ryu, Jae-Cheon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.532-541
    • /
    • 2001
  • Developments of nondestructive evaluation techniques for reduction of strength or toughness by aging of material have been carried out, and the method using electrical resistivity is one of them. In this study, to examine the application of electrical resistivity to the evaluation of degradation of metallic alloy, ten different non-magnetic materials were selected as test materials. Electrical resistivities measured by DC two-point probe method and those measured by non-contact type eddy current method were compared with each other. In addition, to examine the application possibility of four-point probe technology in field, the electrical resistivities for 1Cr-lMo-0.25V steel measured by DC two-point probe method and four-point probe method were compared with each other Differences between two measured values for the 1Cr-1Mo-0.25V steel were 0.6%. Therefore, the four-point probe method can be applied to the estimation of the degradation of metallic alloy. ect.

  • PDF

Fatigue Strength Characteristics of 1Cr-1Mo-0.25V Steel by Improved TiN Coated Processes (TiN코팅 공정 개선에 의한 1Cr-1Mo-0.25V 강재의 피로강도 특성)

  • 서창민;김경렬
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.49-60
    • /
    • 1997
  • This paper deals with the effect of coating layer on the fatigue strength of TiN coated 1Cr-1Mo-0.25V steel prepared by using the arc ion plating (AIP) process, in which it was characterized by the presence of extractor grid (ion filter). The rotary bending fatigue tests were carried out under room air conditions, and the fatigue crack initiation and growth bwhavior were observed by using plastic replica method. As experimental results, it was found that the obvious improvement of fatigue life at lower stress region was confirmed in TiN coated specimen processed with ion filter. It was also exlained that the increase of fatigue life in the case of an improved AIP process with ion filter was attributed to the retardation of crack initiation of the substrate surface due to hard coating layer, more densly formed with the reduced size and density of droplets.

  • PDF